Intertherm propane furnace makes popping sound when running

\015 Furnace is in a mobile home and has not been run for over a year. it lights off ok , but starts popping after 2 to 3 minutes. the fuel company filled the propane tank and replaced two gas regulators that were external to the furnace. the furnace continues to run and makes the popping sound every couple of minutes. the main burner flame appears to be yellow in color.can anyone give us advice on this problem? thanks jim\015

Answers :

It sounds like you have a possible hole in the heat exchanger. Turn the heat off and turn the fan on. If you feel any air coming back out of the heat exchanger, you have a hole. A yellow flame is not a good sign. I would even consider having a service professional come out and take a look.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Intertherm propane furnace makes popping sound when running


It sounds like you have a possible hole in the heat exchanger. Turn the heat off and turn the fan on. If you feel any air coming back out of the heat exchanger, you have a hole. A yellow flame is not a good sign. I would even consider having a se ... Intertherm P3RA-048K Air Conditioner

It sounds like the Furnace is making my mobile home knock in different places throughout my home. It is not the furnace itself, but the ducting coming off the furnace I believe. It only does it in a few different places. It happens while the furnace is running and sometimes will continue to knock after the furnace has shut down. It is loud and wakes my GF and I up at night. What can i do to stop this completely?


If you are continuing to hear the sounds after the system has shut down completely, you might want to consider a pest control problem. Unless your ductwork is sheetmetal throughout it's entire length, Vermin can (and will) cut their way through ductb ... Intertherm P3RA-048K Air Conditioner

Lennox Furnace I have a lennox furnace the bracket on the blower motor broke. I fixed this but now when it gets ready to turn on the blower it blows a fuse. It was still running just before i fixed the bracket. Motor work just fine it only was making a rubbing sound on the cage. everything spins fine by hand. Please help


Make sure to check and see if you do not have any bare wires touch ground or if you have any wires pinched causing a short to ground. Safety first so turn of power before checking. Also check to see if any wires on unit are touching one another. Hope ... Air Conditioners

Intertherm feh-015ha electric furnace blower makes a loud noise when kicks on and runs heats just fine but all of a sudden it starts making this horrib;e noise help


... Air Conditioners

My intertherm electric furnace for mobile home make that makes a cracking and popping and whitling soutnd a 10


... Intertherm P3RA-048K Air Conditioner

My Goodman GMS 90703BXA gas furnace started making higher then normal pitch sounds yesterday. The noise seems to come from the forced draft fan and it only happens in say 3 out of 10 starts so far. The fan vibration does not seem excessive. Is this a sign of an upcoming problem? I've had this furnace running without problems since mid 2004.


The fan in my gas furnace is making a loud screeching noise! Is it going to blow up or is the motor/fan broken? ... Air Conditioners

Intertherm furnace model m3rl060abw blower makes high pitched whine when running. why? how can i fix it?


Not familiar with that specific model, but if it's high pitched, it is likely the induced air blower causing it. sometimes it is possible to disassemble the motor and clean and lubricate it, but the repair that most service personell will do is to re ... Air Conditioners

My 5000 BTU GE window AC is making sporatic loud popping or cracking sounds when the compressor is on and running. It has stopped blowing air! When I put my hand in front of the air vent I can feel cold air but it is not being projected out like it normally is. Do these units freeze up? What causes it, if so? And how can I check? What can I do to get it working right again? We are burning up! Thank you so very much!


Fan inside blower unit stuck or seized. The compressor noises are because liquid refrigerant is coming back because it's not picking up heat from the room. Check/ clean the filters and spin the motor of the fan WHILE SWITCHED OFF. If it spins, it's p ... Air Conditioners

I have an intertherm feh-017ha electric furnace and it's blowing warm air, but the force behind the air coming out seems weak and motor doesn't sound like it's running to it's full potential as it did last winter....


First, check your air filters and change if necessary. Next, if the motor doesn't seem to be running at full speed, the capacitor may be weak. This will cause it to run slower than normal. If you have a multimeter with the capacitor test function you ... Intertherm P3RA-048K Air Conditioner

I have a Goodman split unit installed. The inside furnace works fine. When the system is turned on the outside unit makes a slight "popping" sound like the current is getting there but the fan will not start. I have replaced the capacitor but it is still doing the same thing. Please advise. Thank You, Dan Clevenger. [email protected]


Hi,\015\012 Change the circuit board of the system... no other option.. and also check the electric contactor switch... Have any other queries, please let me know..\015\012Thank you..... ... Goodman Air Conditioners

My Furnace is making a clicking noise only when on heat, and during the initial start up after that it is silent and runs good


Sounds to me like it is a spark ignition which clicks to light the gas and then drops out. This would be normal. If it is hot surface ignition, then the only thing I can think of that would make a noise on a call for heating would be the inducer m ... Bryant 95 Afue Gas Furnace Evolution355cav Plus 95 Multipoise

Have a Payne pg8uaa furnace. Furnace only works when I run a jumper between R and W. Replace wiring to furnace. I suspect that the outside blower motor is the problem. When furnace is running the blower motor has a humming sound but does not blow air. At this point, I would like to know how you would diagnose a Tjernlund HSUL-J blower motor. Should the motor itself be replaced or should the fan prover be replaced?


You would have to test the motor as well as the capacitor on the motor capacitor goes for alot less then the motor though.here is the pdf manual on your blower h ... Air Conditioners

The Coleman Mach thermostat in my 5th wheel blows its 2 A fuse a couple of times today and am trying to figure out what is causing this. Please help. I am unable to get the furnace to run even with a good fuse in the thermoatat. When I bypass the thermostat to run the Atwood furnace (red tied to white wire). THe furnace blower comes on and the burner sounds it lights for 5 seconds and then goes out. 15-20 seconds later it reignites and goes out and continues to cycle -- the blower motor


Hi\015\012\015\012Its blowing fuses because of short circuit inside the coleman mach or due to two wires being shorted with each other. You'll need to open up your thermostat system to look for the short circuit and also shorted wires.Ple ... Air Conditioners

Air conditioning unit Amana Asx130361AA comes on, unit fan runs, house fan runs, then after a minute or so makes a briefly makes a buzzlike sound (compressor trying?) and then continues to run but no cold air.


You have probably a compressor start capacitor or relay damage and you have to replace first capacitor and if problem insist then go to the relay. If the problem insist then you have a complete compressor failure. Often when this happens ... Amana Air Conditioners

Turned on AC was running fine. 30 minutes later began to hear a strange noise. Opened AC/Furnance closet & heard a sound best described as air letting out of a tire. It seemed to be coming from copper pipe. Minute later sound stopped & air was suddenly hot. As if AC was turned on fan not cold. Went outside & neither fan nor motor was running. Turned fan manually. Ran for about a minute then stopped. Outside unit was making what could best be described as a buzzing sound.


Hi!!\015\012\015\012This means that the condenser fan motor (outside unit) failed, this caused to build hi pressure and either activated a safety valve to release the extra pressure or blew a line and R22 Refrigerant escaped from system. ... Goodman CKL42AR42 Air Conditioner

I have a Intertherm propane furnace I ran out of propane I got it filled and went through the steps to restart the furnace it went through all the steps but the light up and then the red light flshes four times which tells me lockout do to failed Ignition what can I do it like it not getting the propane


... Air Conditioners

Intertherm Electric Furnace in mobile home Model# MRAC 2317 SN - 79JE0501 Question: The blower stays running all the time. I have to turn the main breaker off to turn the blower off. The unit is heating when it is running. I have replaced the thermostat about 3 years ago in the summer when I had a AC problem. Would the fan switch on the furnace possibly be the problem? It has an auto & on position on the switch. It clicks when you switch to the on position but does not click when you put i


... Intertherm Air Conditioners

I have a 2005 Pilgram 27 foot 5th wheel. My Duo Therm AC unit makes a ticking sound from the ac unit itself when it's not running. Shutting off the Duo Therm analog thermostat does not stop the ticking sound coming from the AC unit, nor does cutting the AC breaker (20 amp), nor cutting the ac power to the entire RV. I had to cut disconnect the rv battery AND cut the ac power to the RV before it'd stop ticking. When running however, the ac works beautifully. When it reaches it's intended temp


It's obviously on the 12voltDC circuit of the AC unit. Sounds like thermostat, or a relay in control box is faulty or bad connection. If you remove cover on ceiling assy., you should be able to hear it in the control box. There should be a model numb ... Dometic Rooftop RV Air Conditioner

How do I stop my intertherm furnace model # MGH065ab fan from making so much noise?


... Air Conditioners

Gas valve on my furnace makes a buzzing sound when lit


... Air Conditioners

I have a new furnace with a humidifier. Both work fine. The trouble is, the water running through the hose to the drain makes a LOUD dripping noise when it runs into the drain. Is there some way to stop the noise besides turning everything off..I have of tying a string to the hose and then the water will run down the string, but I am afraid the string might break and help clog the drain. any suggestions


Not seeing exactly what you have. I am guessing...does the humidifier have a trap on it coming out of the furnace?. Is this some type of over flow from the humidifier? If so...\015\012\015\012 I would suggest run ... Air Conditioners

Intertherm furnace circulating air doesnot get very warm furnace butas soon as air getswarm it shuts off . house does n ot get very warm even if furnace runs all day.


That is a stack limit switch. You are not venting properly. Is your unit power ventilated or gravity fed? ... Air Conditioners

I have a Goodman 3.5 ton, CKL42-1 outside unit. It was not cooling properly so I cleaned the fins because the were quite dirty. When I turn the system on it will run fine for about 20 minutes and then the fan will stop running but the consenser continues to run and it makes a horrible loud sound. Any ideas?


How did you clean the fins if you powerwashed the chances are you bent all the fins over so the fan cannot pull in air and is shutting of on overload when it cools down it will come back on then heat up and shutoff again ... Air Conditioners

Amana air command 90 model ghn90a35 once in a while on ignition the furnace is makeing a rumbing sound. most of the time when it happens is in the morning after the furnace has been off for a while. flame sensor has been cleaned other than that the furnace works great but i cant figure out what the intermitant noise is. any suggestions would greatly be appreciated. Thanks Johnny


It may be a delayed ignition.Try removing and washing the burners. ... Amana Air Conditioners

Ruud air to air heatpump intertherm propane furnace honeywell th5220d non programable thermostate.fan on furnace will not turn off in aux.mode even though the furnace heat kicks on and off. thank you for any info.Ray


Make sure fan relay is wired correctly (G) wire. Ensure the fan on therm is not on, it should be on Auto or off. \015\012\015\012If your furnace is short cycling because it has to keep heating your home, the delay in the control board m ... Intertherm Air Conditioners