I can't change the fan mode to cool mode.

\015 I have a Peikard split unit air conditioner. I need the user manual to understand the remote control.\015

Answers :

Go to the manufacturer website and try and find their download page for the manuals or literature. If they don't have a download, you will have to contact them either by phone or email. They should be able to mail or fax you one.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have new Samsung 1.5 Ton Window AC ( around one month old). Whenever AC is switched on in FAN or Cool mode the AC (probably FAn motor) make irritating Humming Noise. The noise slightly reduces after awhile. The noise level reduces when lower Fan speed is selected. This problem was not present in first few days of operation. Whether Compressor is on or off does not make any change in noise level. Noise level is same when AC is run in fan mode as well. We have contacted the manufacturer


It is possible that your AC is not getting the right voltage or frequency and hence is trying to scavenge in gettting the current. It will be good if you can check on the mains voltage or on the wiring for a good 15 amp supply line. If there is any r ... Maytag M6Q10F2A Air Conditioner

Amana PTAC Unit is not producing heat. Fan works fine. can not locate manual reset for heat although a label on the unit says there is one. I have an Amana pth153b35ae ptac unit that the heat will not come on. The compressor will run in the cooling mode but not in heat mode. I verified the switching valve is working and the capacitor seems to be fine as the compressor will run in cooling mode. The thermostats seem to be functional because relays can be heard clearly when changing temperature se


I know this is late but I had to add a solution to this problem since I had the exact same problem and was able to solve it. The probelm is not your control board. On these units, the heat pump compressor will not kick in unless the temperature you ... Amana PTH123B25AJ Heat Pump Air Conditioner

I have a sunbeam 12000 btu window unit air conditioner. I can't seem to change the fan speed when it is in cool mode. When I put it on fan only it blows extremely cold air and i can change the fan speed. When i press the power button it stops blowing but it sounds like the motor is still running and I must unplug it to get it to stop.


Sounds like the switch is wired wrong.\015\012When you put the switch on fan only the compressor should not run at all, therefore their shouldn't be any cold air.\015\012Check the switch to see if it's wired right. ... GE Profile ASM10AA Air Conditioner

Fan runs on fan mode then shuts down when changing to cool no start up of compreesor or fan duo-therm


If it is analog, it should have fuse behind front cover. ... Dometic Rooftop RV Air Conditioner

I can't change the fan mode to cool mode.


Go to the manufacturer website and try and find their download page for the manuals or literature. If they don't have a download, you will have to contact them either by phone or email. They should be able to mail or fax you one. ... Sanyo 24KS72 Split System Air Conditioner

New kenmore air conditioner 76081. All of a sudden there is no cooling, only warm air. ice forming behind the filter, which is clean. Fan mode will defrost the ice quickly, but when change back to cool, its warm air and ice begins immediately again. Any suggestions?


Try running the fan on high speed , but the unit probably needs some freon ... Air Conditioners

Hi Guys, I work on a mine site and the temperature on my Mitsubishi model MSZ - 25GEVA split air con has been set and I cannot change it via the remote control. In any mode i.e. cool/ heat if you push the temperature buttons nothing happens. The remote works fine ON/ Off/ Fan etc but they've locked the temperature so it can't be changed. Even if I push the reset button the temperature still remains pre set. I'm of the thought that I might need to remove the batteries and hold done specific bu


... Mitsubishi MSZ09UN Air Conditioner

Bradway/temperzone reverse cycle air con is turned onto cooling, after a few hours the cooling stops and the fan mode kicks in. The han-l-62 controller shows that the unit is working on cooling but on


... Air Conditioners

Lg Neo plasma inverter split model s18ahn isn't heating or cooling properly. When in heating mode air con will go into defrost/preheat mode for 5 minutes and then air con will blow out air for 5 seconds and then go back into defrost/preheat mode. When in cooling mode indoor fan will pump out air but will not get cold. In both heating and cooling modes the outdoor unit will not start up and the outdoor fan will not spin. I have just replaced the main pcb board and that hasnt made a difference. Bo


... Air Conditioners

I have a split system sanyo heat pump model # kmh0922. The evap. fan will not come on when called for in fan mode. When i put it to heat the indoor fan will also not come on. The compressor runs but the reversing valve seems to stay in the cooling mode. When it is put into cooling the indoor fan goes off after 15 seconds and will not come back on. (The condenser fan and compressor seem to act normal in cooling.) Any ideas as to what the problem could be? Thank you, Mike


Sounds like the blowers capacitor has gone bad ... Sanyo Air Conditioners

Gold Star mini split heat pump 24,000 btu. Changed indooe as we as outdoor boards and still goes in cooling mode only. Reset button on outdoor board calls in heat but not by inside hand set. Len Cabana Techno Refrig. Inc. PS: Sometimes indoor green light flashes five times. Close power breaker and try again with inside hand set. Still no heat or fan on.


On a heat pump the difference from heat to cool is the reversing valve.\015\012In cooling or heating the Y1 terminal will always be energized, this is the contactor.\015\012Depending on brand the reversing valve will either be energized i ... LG LS-K2430HL Heat Cool Mini Split Air Conditioner

I have a Sanyo khs1271 that is about three years old. For the last six months it has been making a high pitch chirping sound in both heating and cooling modes. I suspect the problem is the fan on the indoor unit as the chirping only occurs when the fan speed is on high. So far, the only solution to the problem has been to turn it on quiet mode, which reduces the fan speed and thus makes the unit's ability to heat or cool less effective. Does anyone know how to access the fan on the indoor unit


Hi You can try to check this link it has the user manual.Thankshttp://www.sanyohvac.com/assets/documents/user/Use ... Sanyo Air Conditioners

I have a carrier Modle No. 38YXA042300. I am getting an H5 error message on my Thermistat Control. I have run the Fan only mode and the fan in the air handler unit works fine. On the unit when I ingage the manual override, the condener unit and fan motor runs and cools. The unit will not run when I put the Thermidistat on Cool mode. Can you help me. Andrew Construction Mangement Speicalthes, Inc.


On some carriers they have a lock out feature outside to reset shut down power to furnace for 90secs. and then restart ... Air Conditioners

Air conditioner runs for a few hours and it works - it cools the house. Then it stops cooling - the fan still runs but it doesn't blow out cool air any more. It seems like it's overheating or something. It will blow out cool air if it has not been turned on in a while but once it's on too long it stops. I was told it could be the fan motor and the a/c guy changed the fan motor today but that didn't fix the problem. Now he says it might be the compressor or that I need a new system. I'm jus


The things I would check:\015\012Is the system properly charged with freon? Sytem may be overcharged.\015\012Is the compressor out on internal overload at the point of failure? If the overload isnt tripped and the compressor is having tro ... Air Conditioners

Friedrich YM18 230 volt heat pump. The unit has heated and cooled well for about 5 years. Just started heating mode recently and the unit no longer heats. Fan runs OK. Was able to get the heat strip to run for a few minutes (smelled the dust accumulated over the summer burning off). Now, no heating whatsoever. When in the "Money Saver" mode, nothing happens. Fan will not come on and unit will not heat. With "Money Saver" mode off, the fan runs.


... Friedrich Air Conditioners

I have a kenmore air conditioner given to me and it has push button display and with 3 modes, cool, engery, and fan, but when i push the button past fan mode it seems that the air gets cooler but none of the 3 modes are lit up????


Mcdevito75 here Thje bulb to light up the display could have burned out. You can always check with your local A/C repair shop for service. ... Kenmore 75085 Air Conditioner

Hi, I have a wall mount midea split a/c model- MSG-36HR that will only heat. when put in cool mode it only blow's room temp air and the outdoor unit won't run. On heat mode it works normally. I have cycled power a couple of times, changed modes on the remote numerous times and just in case, changed the batteries in the remote. The unit is about 3 yrs old. Do you have any pointers. Cheers Tom


Most heat pumps are 'fail-safe to heat'. That is: the normal position of the valve which reverses the function is in the position which provides heat. The reversing valve must be powered to switch to the cooling position.Although the ... Midea Air Conditioners

Everstar mpk10cr grinding compressor I think.... Fan works fine, will kick into cool mode (elevated fan level) for a few seconds then it sounds like the compressor has a loose mount or something... sometimes it rattles for a few minutes (and cools) but sometimes it shuts the rattling off as fast as it starts and doesnt really ''cool'' or dehumidify.... Some days its works fine all day, others it just never really gets its ''**** together'' so to speak... Can users recharge the coolant themselve


Hi, I hear you , you have to keep her happy and cool!! First of all, no you can't buy R-22 unless you are a contractor and you have a certification card showing you are qualified to use freon. This is not your problem from what you are saying. If thi ... Air Conditioners

The Cool mode wont cool. It's just like fan mode. I cleaned all the dust off the panels and still wont blow cool air.


First the weather is extremely hot mid 90's and humid.I have a Trane combination a/c heat pump system. The A/C was pumping out warm air.I called for a technician and the problem was the compressor was not working.The solution/fix was to replace comp ... Haier HWR06XC6 Wall/Window Air Conditioner

Hi i have a hitachi RA-3186CHA room air-conditioner heat/cool if u turn it on fan works fine but when put on HEAT OR COOL makes a loud errrrrr noise then just blows fan then 30sec or so later makes the same noise like its trying to kick into heat or cool but cant


Hi,Is the air conditioner completely dead? See \015\012section 1. Is the thermostat knob turned to the proper setting? Is the \015\012compressor motor running? The compressor is a football-sized case with \015\012no apparent moving parts. ... Hitachi Air Conditioners

My bonaire evaporative cooler cycles from high to low fan speeds when set in the cool mode. It works fine at the required speed setting when just the fan (no water) is selected. It also dumps water immediatly the cooling cycle is turned off rather than holding it for about 40Min as it should. Sounds like a controller problem, but I'm not sure if it would be the touch pad or the board up on the roof mounted unit.


... Air Conditioners

Hi, I have a samsung aqv18ja series split type air conditioner (cooling and heating) wall unit. the unit was install in 02/12/2009. By "one hour heating and air conditioning". In this short time service the outside compressor has been replace, the system has check and recheck,for cooling leak. the inside unit fan motor has been change. but the problem still exists. The inside unit fan continues to run when the unit is "off" and with the remote off.


Simple, check in your remote. There is an option button "Blow". Just press it. Your unit gets completely off. Please write back if helpful? ... Samsung Air Conditioners

Its a trane unit model# TUE060A936K3 in cooling mode condensor comes on the indoor fan does not in heating mode every thing comes on but the blower fan does not there is not a led light blinking code lable on the unit i it looks like its giving 4 blinks pause and repeat 4 blinks etc. what does this mean


Hi,\012Either the vent is blocked or the pressure switch that tells it that the purge blower is running is not working right...for some reason that switch is not making contact and so it will not let it light..\012\012heatman101 ... Air Conditioners

I have an American Standard Heat pump. The unit is one piece is is outside. The problem that I have is that sometimes when the unit kicks on cool, the fan motor will not start. The compressor will run, but quickly freezes up. I can put unit in off and wait for thaw and then put back in cool mode and fan will start. Any ideas?


Definitely a low voltage problem then i would look for the obvious like loose connections good luck you might have to call a tech ... Goodman CLQ36AR49 Air Conditioner

Window Unit - Fan does not come on in high & medium cool modes, works fine in low cool, fan also works


Fan motor speed control on the motor itself is out.. Replacement is only option. Good Luck\015\012\015\012Dave ... Air Conditioners