\015 My contacts on my outside a/c unit are not working!! it wont work until i push it in myself!! do i need to replace it and how???\015

Answers :

Do You have a volt meter? You might not be getting low voltage to the coil. Make sure your two wire coming out of the house is not broke and connected to the coil on the contactor.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have central air ( Dimond 80 York Heating Air conditoning Unit ) My air conditoning unit has stopped working. The board has checked out ok.but there seems to be a voltage problem some where from inside to the the air conditoning unit outside, the voltage reading is 26 inside and only 10 outside not enough to start the unit . Do You have any idea as what the problem might be? Thank you, drewskie


Try the following step.....On a call for heat, the 24 volt thermostat sends a signal to the\015\012control module. The control module will indicate a call for heat with a\015\012light on the control either blinking or remain solid d ... Air Conditioners

Rv air conditoner turns on but will not cool air. the themostate works good when heat is turn on no problems. the air conditioner acts as if there is no coolant, or maybe not enough. if it were an automoble I would just have to add freon or some type of coolant for rv's. there does not seem to be a way to recharge it.


RV air conditioners are a closed system. A Refrigeration mechanic can install valves and re-charge it, but by the time you pay for that, it may be smarter to just replace the unit.You say it's turning on, but do you actually hear the "hum" or "moan" ... Air Conditioners

Rheem air conditoner problems


It might have leak and low on gas or the main PCB board is defective. try switching off and on circuit breaker ti might reset the system ... Air Conditioners

Air conditoner problems


Do You have a volt meter? You might not be getting low voltage to the coil. Make sure your two wire coming out of the house is not broke and connected to the coil on the contactor. ... Goodman CKL24AR24 Air Conditioner

I need to find a through the wall air conditoner of 12,000 BTU's with 110/115 voltsthat will fit a wall opening only 22 1/2 inches wide. Height is 16" and depth is not a problem. I'd even take a 10,000 BTU unit if it would fit. Can you help?


Most of the 12,000 BTU's Unit dimensions are 18.9 x 14.4 x 22.6.\015\012click the link directly to check out.\015\012 ... Amana AC123E Thru-Wall/Window Air Conditioner

Compressor I have a air condition unit that blows out cold air for a little while and then the air in neither cold nor hot. I had someone come and check it out and they said the compressor was bad. Is that really the problem or could it be something else? The model I have is Intertherm T3RC-042K. I just don't want to have to spend that much money on fixing the compressor and that is not the problem. If it is the problem, is it something that can be done yourself or does a professional need to do


If the unit does blow out cold air for a few minuets then quits it could be a low pressure cut out that will turn off the compressor because the unit is low charged mening there is a leak in the sealed system i would get a second opinion and show th ... Intertherm P3RA-042K Air Conditioner

Have an amana central air duelfuel heat system.when aux heat[gas] heats the house and shuts off the fans still blow for 3 to 5 minutes with the last couple of minutes being cold air which cools the air it just heated. also heatpump will start heating when it comes on then after 3 or 4 minutes it starts blowing cold air like when the air conditioner is running.i have had problems from day of install 4 mounths ago with problems that keep coming up. please i need help fast i do not think comp


Change your heating delay to shut off sooner, you can find this in the installation manual. Also the Thermostat may have delay after heat as well. It is true there could be many variables, but it also sounds like the Heatpump is not charged properl ... Amana Air Conditioners

Sharp Air Conditioner AC09RLCSYS isnt cooling properly. Very moderate to low cold air from unit. At one point small bits of ice came out of indoor unit when on auto cool. Unit was switched off immediately and then turned back on after a few minutes with no additional problems, however still is not cooling properly. Unit is only eight months old. First used for cooling with no problems and great cold air, then for heating during winter. Now back to cooling and not getting the cold air like p


Unit may be freezing up if blowing ice crystals. Let thaw 24hrs try again. Make sure condensation drain line is cleaned out. ... Air Conditioners

Fails to ignite,sparks but pilot will not ignite. have had problems with pilot going our for about three months. Thought attic air flow was the problem. closed off air vents in area of heater. problem ceased for about three weeks. now pilot will not ignite when attempts are made. Rudd water heater, model PH2 40S 40F


Sometimes the pilot orrifice get plugged up and need to be taken apart and cleanned,,,,,, adjust the pilot flame on the gas valve, or check gas going to the unit to see if the in-line gas valve is opening and closing. ... Ruud Air Conditioners

My Carrier 52CE Unit has a problem not accurately producing either heat or air conditioning. It will send chilled air for an hour and then frost over. It sends warm air in the winter but not consistant. Could this be a thermostat problem. Or is it something else I should look at?


... Carrier 52CE-309 Cool Electric Heat Air Conditioner

Heating problem hello! My air conditioner stopped to heat. (there is a around 8 degrees C, outside and 16 degrees inside). It worked just fine, and now, when I switched to heating mode, there was nothing. the defrost LED ond the inside unit is switched on, but air is not comming from the unit. Cooling mode works fine. If you could please help me finding the solution for my problem. Thanks in advance. RAdan GE AIR CONDITIONER SPLIT SYSTEM WON'T WORK ON HEAT CYCLE Seems to work ok doing eve


Hi Radan, Did you get this problem solved? We have an Electrolux Kelvinator Split System and ours is doing exactly the same thing. I am struggling to find a solulution. Would be great if you can offer any advice.\015\012\015\012Thanks Nic ... Air Conditioners

I have two indoor condensores, one with both lights on, but not blowing cold air, and the other with only one light flashing, but blowing cold air. History; 5yr system, did blow 100amp breaker during storms, just usually reset and no problems, initial problem one light flashing and no cold air, and other unit with both lights on and blew cold. Any help, thanks Darrick


You need a new pc board. You can buy one from http://paylessminisplit.com ... Mitsubishi MSH09TW Air Conditioner

We have central heat an air , the heat is up in the attic and the air is outside, our problem is that the air is blowing in the house but th unit outside doesn't come on , what could be the problem. Thanks


Check your breaker or fuses. for the outside unit. It may be getting the "Signal" to come on but there is no power. Start there and let me know. ... Air Conditioners

My frigidaire air conditioners spit dirt all over the floor. My window unit and my through the wall unit in a sleeve both do the same thing. I called Frigidaire two years ago and they told me there were no reported problems. I keep the filters clean and don't know what is causing this. My rugs and furniture are full of dirt particles when I use these units. I have had air conditioners for many, many years and have never experienced a problem like this. Please advise me if this is a problem with


1. Turn units off\0122. Remove Filter\0123. Spray a foaming cleaner on the coils (Dow Bathroom Cleaner)\0124. Use a spray bottle filled with plain water\0125. Replace Filter and Grill ... Frigidaire FAC124 wall/Window Air Conditioner

Delonghi Pinguino Classic Portable Air Conditoner Works for 30 min then red light comes on


Have it serviced. It cost me $250 to have a pro do it. Also, check the timer (the dial is hidden by a sliding cover on my unit). My husband cleaned it himself a year later and he took it apart to do it and it works much better now. When he opened it ... DeLonghi PAC85 Portable Air Conditioner

My ac will blow cooled air, but then the ac unit will stop cooling and just blow hot air for a while. It'll switch back and forth instead of just blowing cool air. An ideas on what the problem i


... LG LXA1230ACL Air Conditioner

Central air conditoner outside unit


Well, the answer is yes. I have seen a bad capacitor cause a fan motor to run backwards. BUT..... After replacing the capacitor and WIRING it up the right way, everything should be fine. A lot of aftermarket condenser fan motors are reversible, so it ... Air Conditioners

I have a fujitsu reverse cycle air conditioner,it wasnt working(not blowing cold air only room temp air like a fan).air con tech came over,re-gassed it,tried air con that day,worked fine.didnt need to use it for a few months,re-tried it,no cool air again,i am thinking of a leak.My question is the air con is about 10 years old,if cause of problem is a leak,is it worthwhile fixing it(i would need to pay someone parts and labour,could not do this job myself),or to just bite the bullet and get a rep


Hi,\015\012\015\012The A.C is 10 years old which is a ideal shelf life for the A.C. If there are any leaks I would never ever try repairing it at home becuase if there is a leak then that means that the entire GAS which helps in the cooli ... Air Conditioners

Central air My central air unit continues to freeze up on the outside, as well as on the inside on top of the furnace. I had it checked and was told the return flow was the problem and to take the fliter off and make the return flow larger. This has done nothing!!! It continues to ice over. Any ideas? Please..it is sooooooo hot here right now. Have never had a problem with this and all of a sudden it is freezing up. Thank you


HEY_ 2 viable options suggests them self to me, 1 - low airflow ----------2 low on freon charge! Thank-you-very-much! ... Whirlwind FH-778 Air Conditioner

I have a coleman air conditioner 6799A800 series- super mach. On very hot days it starts and cools very good, but then the compressor kicks out. We think it might be becasue so many people are using power for their air conditions that it's drawing the power down. My friend had the same problem he changed the capasitor in his unit and now it is working properly, could this be my problem? If so do you stock the capasitor I would need?


... Coleman Mach III Air Conditioner

Have a problem with my Intertherm air conditioner not coming on so I put a new thermostat on it. Nothing comes on fan nor heat nor air. I reset the breaker but still nothing and the unit model is a E1eb015ha? Anyone know if there is a reset button on the unit or where I can start looking to see if there is a problem.


Turn the thermostat off and check for 24vac between R and C on the thermostat. If there is no C then to G or W. If you don't have 24vac go the transformer and check for 24vac on the secondary. If it isn't there then check for 120vac on the transforme ... Intertherm P3RA-048K Air Conditioner

I have a mitsubishi air conditioning unit model MUH-12v. The fan on the machine outside has stopped and of course inside the air is not cold. Could this be a problem with replacing the gas or could it be a technical problem with the outdoor unit. Also I have noticed when I switch on the unit on the inside with the remote control that instead of two green lights comimg on I only have one green light flashing. Does that mean anything?


Hi,Here is a tip about Mitsubishi Air Conditioners and how to get the manuals for all of the mitsubishi line. The manual include both troubleshooting and installation. ... Air Conditioners

In hottest part of day it starts blowing hot air. We turn it off for 2-3 hours and comes back on anabnd blows cold air again. Technician unable to determine problem. Says we should buy all new unit. Current unit 10 years old. Coolent level ok. Coils clean. This is a 2 ton small unit cools our master suite only. Our other unit is 4 tons and cools rest of house with no problem.


For this case, either the AC needs cleaning or the compressor may be week.  You may want to check on the thermostat, it may send signal to the unit to stop cooling.  If it is a split type AC, you may want to check for leaks in the tubes tha ... Air Conditioners

My hvac duct work on one of my central air units has a lot of condensation and causing puddles of water throughout my basement. Do you know what the problem is? The drain lines don't seem to have any leaks. There is condensation at the main supply unit of the HVAC system (gas forced air system). Can anyone help understand what the problem is and how to fix it?


Could be just not insulated enough is this a new instalation? the humidity is too high around the ducts is their a return air vant close by that you can open? you need to lower the humidity or seal the ducts so it cant get to them dan ... Air Conditioners

I'm having a problem with my heating and air system, my heat only works on emergency heat ( and run 24/7) if i turn it to regular heat it only blows cold air. i dont think my outside unit fan is turning( i could be wrong about this one) how can i fix this problem so i dont have to run my emergency heat all the time


If your Heatpump's fan isn't running but your compressor is, your fan motor is out. If nothings happening at all ensure your getting power to heatpump (ex: breaker tripped, fuses blown on outside power switch, or fuses blown in breaker box?) ... Air Conditioners