Having problems with your Air Conditioners ?

I just bought a house and don't know how to use the honeywell AC,it's a central AC,has a manual control,when I turned on , I don't feel any cold air,I notice the fan inside the house is working, but the device outside the house is not. The thing is I don't Know if I'm seeting up correctly or not or the AC is broken


Answers :

Do you have the system on A/C and it's calling for it to come on? If so, go to your breaker box and see if the unit is getting power. Also, you will need to check if the unit is being told to come on by the tstat. If you don't know how to check voltages then leave it to a professional but you first check should at least be the breaker. There is also another devise on the wall outside near the unit called a disconnect and it might have a breaker in it as well. Not all disconnects are the breaker type and not all units have them. Hope this helps.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I just bought a house and don't know how to use the honeywell AC,it's a central AC,has a manual control,when I turned on , I don't feel any cold air,I notice the fan inside the house is working, but the device outside the house is not. The thing is I don't Know if I'm seeting up correctly or not or the AC is broken


Do you have the system on A/C and it's calling for it to come on? If so, go to your breaker box and see if the unit is getting power. Also, you will need to check if the unit is being told to come on by the tstat. If you don't know how to check v ... Air Conditioners

Model UAKA 030JAZ was working fine. Now, the compressor fan does not come on and neither does the compressor. I don't know how the contactor works but it is not engaging (the spring loaded contacts are not closing) and there is 120 volts on each side. Blower inside house comes on.


HelloYou need to complete the 24 volt circut from the themostat to the transformer to get the contactor to pull in.Check for voltage at the transformer,should be 120 v in 24 volts out.Also there may be a small reset button on the tr ... Ruud UAKA030 Air Conditioner

My unit is 4 years old. I always turn it off when I leave for work in the am and turn it back on when I get home in the pm. Last night I turned it on at 7:30pm. When I went to the front of the house about 45 minutes later, I noticed the unit outside was trying to turn on but would immediately turn off. I checked the breakers in the garage, turned them off and back on but still had the same problem. The fan inside the house is running but unit outside will not kick on. I looked for a magic


It could be a few things.. It could be the capacitor - which the most economical to replace first..\015\012\015\012If you are not really very mechanically inclined - get a trained pro to come out.. It is very dag ... Air Conditioners

B & D company air conditioner(model# 566DJ024-C) makes buzzing noise. I just bought a house and when I turned on the air...the unit outside makes a buzzing noise. The fans seems to work and cooler air is coming out of the vents(only ran it for a few min,didn't want further damage). I had the home inspected and the inspector said that the inside breaker is 30amps and the actual max for this particular unit is 25 amps. I don't know if that is the problem or something else...just thought I'd mentio


The circuit breakers Ampere rating has nothing to do with the buzzing noise. If you use a lesser Ampere Circuit Breaker it will trip every time the Air Con: starts, and if you use a very high Ampere Circuit Breaker it won't trip and give you the need ... Air Conditioners

About two years ago, I purchased a: Hunter 56 In. Brushed Nickel Ergonomic™ Remote Control Ceiling Fan Model 21871 A few months ago, a bolt of lightning struck through my house and my fan stopped working ever since then. The remote works fine since I can see the senson light up. And I know the electrical wiring is fine too because it was tested. However, I don't believe my fan is under warranty and I sm trying to find someone who could look at it and let me know if it's worth the mone


To have a contractor in your area look at this unit, try using the contractor search on the home page of fixYa, or simply use the yellow pages for your area.My guess is that the lighting burnt or damaged the motor windings in the fan. I a ... Hunter Air Conditioners

Contactor not engaging to start condenser unit . When setting the thermnostat, i hear the click from the unit starting inside the house. Fans start and air starts blowing inside the house, but the condenser unit never starts. I tryed pushing the contactor by hand and then everything works find (cool house) as long as i keep the contactor pushed manually. Seems alike the 24 V (coil) bobine in the contactor is not been energize. When I tried the 24 V outside with a 24 V surce it worked fine. Thank


I would replace the contactor if you are getting 24 volts to the contactor and it isn't engaging therefore the magneto on the contactor is out and the contactor will need replacement. If you don't have 24 volts at the contactor then the transformer ... Air Conditioners

My AC unit ouside the house works,but the fan inside the house does not work. It does not come on any more, not even when I change the fan setting from Auto to On.


Check the breakers first they are probly on seperate breakers if thats not the problem your fam motor may have over heated and need to be reset or replaced after being tested ... Hitachi RAS-09UH Air Conditioner

We have recently purchased an older home, built in 1931. There is a whole house fan in the attic that we would like to get working again. We do not know when the fan was installed or who made it - however, it is a very large whole house fan - 42" blades with 46" frame. Our home is only 1200 sq ft and from what we have found on the internet - a 42" fan is made for 3000 sq ft homes. The motor was made by Leeland Motors - 1/2 HP - 1725 RPM. However, we cannot find anything about this company or how


What and interesting situation. I have seen installations like what you describe, but not in a residential application. Industrial applications that had very high ceilings and in very old apartment buildings, But not in single family resident. I susp ... Air Conditioners

Hi, just replaced the capacitor thinking that would solve the problem but it appears it did not. The motor outside would kick on the unit inside would kick on but the blower motor inside works sometimes and wont other times. Basically, the unit will work just fine all day then we notice the house is getting warm, check the inside unit and everything is running fine but the blower motor is not circulating the air. I have a goodman a30-10 unit. I read where some people said the relay could be bad


Turn off the power to the air handler(indoor unit). Remove the access panel. From the motor,trace the wires back to the fan relay. One wire will probably trace back to the incoming power terminal. The other is the fan relay. It could be intermittent ... Air Conditioners

Have a whole house fan which has a 2 speed motor. Stopped working. I know there is power to the fan. checked with a voltmeter. Have taken off the 2 speed switch and connected the two black wires together, did not work. connected the two black wires and a red wire together, did not work. Is there a way to test the motor?


Test Motor: Gain access into the motor area then smell the motor. If you detect a strong odor (the shellac that coats the copper coil windings when the motor is burning or burnt out) then the motor is bad and needs to be replaced.\015\012Second ... Air Conditioners

AC, Fan-Auto, Fan-On... nothing works. the request from the Thermostat doesn't engage anything. Thermostat Dispay works. How do I know if it is getting the 24volts from the relay? I presume the display wouldn't work if the 24v from relay wasn't there. I have two separate systems in the house. So therefore, I pulled the thermostat off the base and tried it on the faulty system. No luck. Still same issue. Perhaps it's the Honeywell base itself? what electronics are in there that could fail? How ca


Open the air handler. Locate the low voltage transformer. One side is 220 volts input. The other is 24 volts output. Take your VOM and touch the test leads to the input to verify 220v in. Then touch the other 2 leads to verify 24v out.If you ha ... Honeywell Air Conditioners

Hello, We bought a Perry Home in Georgetown TX last March and it is still under its two year warranty. Our air conditioner stopped cooling today. It has been working well for over 1 year. We came home from work and the temperature is 86F inside and climbing. My wife left the house at noon and the temp was 76F (where we keep the thermostat in the summer). The Air conditioner outside unit's fan is operating and no noise. The inside blower is running normal - no problem. The model number on the o


You have a 10 year warranty on your AC. Call a Goodman rep and have it serviced. It will probably be a bad compressor capacitor. Bad wire or no refrigerant. ... Goodman Air Conditioners

I have an XB10 Trane AC unit that was installed when my house was built in 2003. After running it for a while, the compressor either seems to shut down and I notice no cold air as though its just the fan. Sometimes when I start it back up my thermostat says ''wait''. Or it just blows the fan, even though its set for cold. I've had the capacitor replaced, a start up capacitor bridged to it. I've changed the filter and had the coils cleaned with a brush and garden house from the inside. I'v


... Air Conditioners

I transfered my hitachi AC split type model RAS25RC to my new house but when the technician re-intalled the unit, the fan inside working but the compressor and fan outside was not working. what seems to be the problem?


... Hitachi RAS-09UH Air Conditioner

I bought a used furnace and when i hooked it all up the green light that says working is flashing instead of staying on constantly. dont know if that is good or bad. but the automatic pilot will not light and i am not getting the fan to turn on or anything. the draft induce motor is warm to the touch after a few minutes so i know that it is trying to work. not sure if that is the correct name of the motor exactly.


Something is not right here. Turn it off and check the power connections to the unit.. something is hooked up incorrectly. If you can send me a photo of the schematic I can tell you how it should be connected. ... Air Conditioners

My fan and heater work fine, but today I turned on my air conditioner for the first time this year. It did not feel like it was getting cooler so I went outside and noticed that my outside unit was not working. I went and checked the breaker and noticed it was tripped, so I turned it off and turned it back on (the breaker). Then all orf the power went off to my house. I then reset my whole breaker box and I heard what sounded like my outside unit explode. I ren over to it and it sounded lik


You had a refrigerant release. Probably two lines rubbing together in the outside unit. I have repaired several of these with this problem. It involves repairing the lines by silver solderingthen pulling a vacuum/ purging with nitrogen an ... Carrier 36KCARMS Air Conditioner

Coleman eb12b will not cool. Fan are all working inside and out. When I turn the unit off and to auto. The fan sound inside house get lower, but don't go off. After unit runs awhile coil are wet.


... Coleman Mobile Modular Home Electric Furnace Eb10 Eb10c

I have a goodman spliit system clj42-1c. Outside fan does not run. I removed it and gave it power and it came on. Then with fan removed I powered up the unit the compressor hums for a minuite then cuts off but it never seemed that it was realy working. Thear is freon in the system. I need to know if the capasitor is at fault or if the compressor is bad. I am an air craft tech so I have a multimeter and enough know how to find the problem. I just dont want to purchase the wrong part. Can u tell m


If your multimeter has a Capacitance Meteryou can test the capacitor. There are ways to broadly test a ca ... Goodman CLQ36AR49 Air Conditioner

Fan runs but blowing hot air. Thunderstorm reset some breakers. I did reset the two breakers inside the house and one unit working fine, upstairs unit fan running but blowing warm air only. Box out


Sounds like your Capacitor is bad, or you had a wire burn off compressor terminal or capacitor. Way you can check capacitor is take cover off and see if looks swollen. Make sure to turn off power before taking panel off. ... Air Conditioners

I have a fujitsu halcyon inverter evaporator that isnt working. The indoor wall mount is blowing air, but the evap outside isnt working. The fan doesnt seem to be working. I have another 2 piece fujitsu, same exact model that is working fine, drawing air into the evap. Dont know much about trouble shooting, any tips would be appreciated because its hard to find info on these things.


... Fujitsu Air Conditioners

I have a split system air conditioner. the inside fan turns on fine but the out door will not. i pushed the contactor in (located at the outdoor fan)that seems to turn on the fan. i measured the voltage with multimeter across the contact 24 volt side and got low voltage reading. then i disconnected the wires to the 24 volt side of the contactor and measured the wires, the wires read 24-27 volts. i dont know why when i connect it the readings are low. i even got a new contactor and still the same


Contactor working means fan might be bad can you feel any resistance from fan or bad capacitor. ... LG LSC091PMA Split System Air Conditioner

I noticed some straining noise coming from my a/c unit today. The fan on top of the condenser runs fine but as soon as the compressor tries to kick on the fan stops for a split second and you get a kind of surging noise from the condenser unit. Then the fans kicks back on, the the process repeats itself every couple of minutes. Meanwhile no cold air is being produced inside the house. Any ideas?


You amy ahave a bvad capacitor on the outside unit. It starts the fan and the compressor. You can change this yourself. Open the outside panel and you will see a silver canister with terminals out the top. Replace this and I think your problem will g ... Goodman CKL24AR24 Air Conditioner

My unit is running but not blowing cool air. I went outside and the condenor fan was not moving. Took a stick and shoved a blade and the fan started moving but the air is still not cool inside. I did notice the air coming through the unit outside after fan was blowing was cooler than my 2nd a/c unit that was working fine. I wondered if the entire unit was frozen. I turned off unit at thermostat and figured I would see what happens tomorrow


Sometimes on new units it is common for the fan to not start until you give it a push. Did you happen to hear if the compressor was operating? If the unit was froze-up the Insulated Suction line would also be iced over as well. If it wasn`t it is mor ... Carrier 38CKC024 Air Conditioner

Amana air command 80 SSE started makeing humming sound id shut it off and wait a few minutes and it would work again been doing this for about a week and now its not working what so ever it was blowing cold air but when humming it wasnt blowing anything at all i checked to see if the fans were binding up but their spining freely any ideas i see a sensor light but i dont know how that works either. please help im melting thanks


Sounds as if the motor is heating up and shorting.Call a pro to find out for sure. ... Air Conditioners

Earlier this week, I noticed that the house felt "stuffy" but the thermostat showed everything to be cooling as expected. Last night, the house was definitely warmer than expected when we got home. My husband did some checking and found that the outside unit was running as normal, but there was no cool air coming through the vents inside the house. turning the a/c unit off at the thermostat did NOT turn off the outside unit...was only able to do this at the circuit breaker. It seems that the fan


If both fans runs (inside and outside), check if the compresor runs , if does probably the unit is low in freon and needs to be recharged after the freon leak has been fixed (remember this is a seal system and it shouldn't leak), but if the compresso ... Ruud UBHC Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific