How do you take out the fan blade? - GE Zoneline AZ28E12DAB Heat Cool Air Conditioner


Answers :

Because of the various different configurations and brands, its virtually impossible to tell you how to remove your particular fan blade. I will tell you that on these types of units and being so compact they are hard to work on. But I have included the care and maintenance of the unit. You might find this helpful.
\015\012http://products.geappliances.com/MarketingObjectRetrieval/Dispatcher?RequestType=PDF&Name=49-7559-1.pdf
\015\012
\015\012The fan shouldn't be hard to replace once you slide the unit out of the framing. I wish I had more info for you. If I had some pictures of the unit, it would be easier. Good luck to you.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

How do you take out the fan blade? - GE Zoneline AZ28E12DAB Heat Cool Air Conditioner


Because of the various different configurations and brands, its virtually impossible to tell you how to remove your particular fan blade. I will tell you that on these types of units and being so compact they are hard to work on. But I have include ... GE Zoneline AZ28E12DAB Heat Cool Air Conditioner

Fan does not work,power board gets power ok - GE Zoneline AZ28E12DAB Heat Cool Air Conditioner


GE Zone have two boards Drive board and control board. Sounds like bad fan motor. I work on Zonelines and the motors go out more than anything else. Rusty ... GE Zoneline AZ28E12DAB Heat Cool Air Conditioner

Fan starts when unit is off - GE Zoneline AZ28E12DAB Heat Cool Air Conditioner


It has an unoccupied set point. ... GE Zoneline AZ28E12DAB Heat Cool Air Conditioner

Hi, I have a samsung aqv18ja series split type air conditioner (cooling and heating) wall unit. the unit was install in 02/12/2009. By "one hour heating and air conditioning". In this short time service the outside compressor has been replace, the system has check and recheck,for cooling leak. the inside unit fan motor has been change. but the problem still exists. The inside unit fan continues to run when the unit is "off" and with the remote off.


Simple, check in your remote. There is an option button "Blow". Just press it. Your unit gets completely off. Please write back if helpful? ... Samsung Air Conditioners

Have an amana central air duelfuel heat system.when aux heat[gas] heats the house and shuts off the fans still blow for 3 to 5 minutes with the last couple of minutes being cold air which cools the air it just heated. also heatpump will start heating when it comes on then after 3 or 4 minutes it starts blowing cold air like when the air conditioner is running.i have had problems from day of install 4 mounths ago with problems that keep coming up. please i need help fast i do not think comp


Change your heating delay to shut off sooner, you can find this in the installation manual. Also the Thermostat may have delay after heat as well. It is true there could be many variables, but it also sounds like the Heatpump is not charged properl ... Amana Air Conditioners

We have a Goodman Furnace and Air Conditioner approx 7 years old. When I put the Cool on thermostat and lowered the temperature for the air conditioner to come on the furnace fan started but the outside air conditioner only made a humminging sound. How long does it take for the air conditioner to start? I thought in previous years it came on quickly. I changed batteries in thermostat and reset the brakers on the main electrical panel. Could you please give me some advice. Thank you.


Hi, You are right. The outside unit starts quickly. The humming will either be the evaporator fan or the AC compressor itself. If you can reach into the evaporater fan with something narrow and stiff you may be able to see if the fan turns. Sor ... Air Conditioners

After a cooling cycle, when the thermostat call for more cooling, it take up to 5 minutes after the air handler starts for the compressor motor to restart. The top fan operates on the outside unit, but since the house is not circulating cold air, only the room tep air the house heats up about 3 degrees before the compressor comes back on and cool air begins to come from the ducts. Yes. I know there is a safety feature to protect the compressor, but can the cycle be shortened?


No, this cycle cannot be shortened due to the simple fact that this feature is in place to protect your system. Even if it could be, I wouldn't recommend it.Mat ... Coleman Air Conditioners

Hi i have a hitachi RA-3186CHA room air-conditioner heat/cool if u turn it on fan works fine but when put on HEAT OR COOL makes a loud errrrrr noise then just blows fan then 30sec or so later makes the same noise like its trying to kick into heat or cool but cant


Hi,Is the air conditioner completely dead? See \015\012section 1. Is the thermostat knob turned to the proper setting? Is the \015\012compressor motor running? The compressor is a football-sized case with \015\012no apparent moving parts. ... Hitachi Air Conditioners

My LG 7000 BTU Heat / Cool Window Air Conditioner does not cool and the fan speed F1 will not work. Fan runs on F2. The heat works fine. Any suggestions?


You have a control board issue. You can get a new control board by Google searching the make and the model of the unit. There are several sites that sell them ... LG Heat cool Window Air Conditioner

Cools for few minutes then stop cooling....Hi my unit GE (APH10AA) Air Conditioner, only cools for 10 minutes and then stops then is the fan that runs forever , with out getting to cool again,plus the back of the unit ,the vent takes out lots of VERY HOT AIR, my room will get so hot ,what I can do to fix it? please help


... GE APH10AA Air Conditioner

My Fujitsu Converter Air conditioner is not working... The Green light is flashing 13 times - the red light flashes continuously very quickly. The fan does not commence at all and therefore no heat or cool air comes from the conditioner at present. Also, once I press the start button on the remote control unit and the light being to flash, I am then unable to stop the unit - even after pushing the start/stop button - the lights continue to flash. Is there something I can do to make the air c


... Fujitsu Air Conditioners

I have a Ruud heat pump/air conditioner. The out side fan and unit works fine and cools fine but now the inside fan that blows the cool air in will not turn on. We can turn the fan with our hand so I don't think it is locked up. Please help!


You didn't mention if you checked for 115 volts at the power supply to the air handler. The unit outside has its own power supply. A lot of times the switch that is on the wall doesn't like to work after its been turned off and back on for service, ... Ruud UBHC Air Conditioner

Hello, I have two Yokohama Split type air conditioners that work fine for cooling, but when switched to heat they just blow air at room temperature and then after about 1 minute go into a standby mode indefinately. They work perfectly for cooling. All fans work perfectly and the compressor works perfectly for cooling. Thanks...


... Air Conditioners

I have a honeywell pro 2000 programmable thermostat which controls an enerzone ahc 31-18 series water source air handler with heating and cooling coils built in. This therostat and heater worked fine all winter. Last week i had a air conditioner stalled and connected to the air handler and the AC worked for one day. When i tried to turn on the AC yesterday, the fan would not come on for either AC or heat. any troubleshooting suggestions? thanks ... Donald


... Air Conditioners

I have a Quasar Model HQ2082KH window air conditioner. It's been running perfectly until yesterday; the fan is making a terrific noise (on any fan or cooling setting) as if the blades were rubb


... Quasar Air Conditioners

I have a ruud achiever 10 model UPKA-018JAZ with air handler in attic. Was wondering if this is a single stage heat pump or a multi stage? trying to connect new thermostat, air conditioner is working but when turn on heat only the fan comes on and the compressor outside never comes on to warm..but compressor does come on when switch to cool..


This may be as simple switching the thermostat to electric, under the cover is a gas/electric dip switch. Hope that helps. ... Ruud Matching Split Air Conditioner

Ge heat and cool fan problems - GE 12,000 BTU Heat And Cool Air Conditioner - AEE12DQ


... GE 12,000 BTU Heat And Cool Air Conditioner - AEE12DQ

We have a dual therm dometic air conditioner on top of a livestock trailer. Air only no heat. It has been cleaned and very clean filters. Always has worked great this year got ready to start up and will not cool. Compressor seems to be coming on but never cooling and there is no condensation like always before....do these take freon and how do you go about adding if they do? What is your suggestions


Unfortunately this will require some specialty tools and most people don't just have them in the garage. The unit definitely has freon in it or used to. These types of unit never tend to have valve you can add refrigerant through so someone must add ... Air Conditioners

The central air in my house is running and cooling pretty good, but after working for a while, the fan starts to make a noise. Do you think it might be the bearings or something. I tried to take of the fan blade to check the bearings but it difficult to take off. I will be happy if someone can advice me on how to solve this problem.


Hi,\012You are correct... it probably is the bearings.\012Sometimes you can get oil into them, but often that is a very temporary fix..\012I would replace the motor , they often do fail...\012\012Here is a tip about trou ... Air Conditioners

Lg Neo plasma inverter split model s18ahn isn't heating or cooling properly. When in heating mode air con will go into defrost/preheat mode for 5 minutes and then air con will blow out air for 5 seconds and then go back into defrost/preheat mode. When in cooling mode indoor fan will pump out air but will not get cold. In both heating and cooling modes the outdoor unit will not start up and the outdoor fan will not spin. I have just replaced the main pcb board and that hasnt made a difference. Bo


... Air Conditioners

We have a slim heater/ air conditioner on our wall. It's been in airconditioning mode for the summer. I'm having trouble 1 . it shuts off within seconds of turning it on. I've tried to cancle the timer. Lost the manual. 2. I cant get the fan to blow warm air, the blade to even rotate but it works with cold air!!!ouff... ....the remote is on heat ....temp says 74 on both wall and remote mdl # LMN120HE suggestions?!? We're cold.....


This is a tippical heatpump problem. get the revers valve unstuck. energise the coil to the valve, on and off. make sure the power is on to the coil.(HEATING MODE AT FULL TEMP). if you are not electrical minded leave it be. get someone with electrica ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

This is a heating and cooling through the wall heat pump. It works normally when heating is selected - the heat pump runs and both speeds of the fan blow warm air. But nothing runs when cooling is selected. In other words the unit works normally when "High Heat" or "Low Heat" is selected but nothing runs when "High Cool", "Low Cool" or "Fan Only" is selected. The position of the Fan Cycle Switch has no effect - behavior of the unit is the same in both positions of the Fan Cycle Switch.


You have a bad board or bad switch. I would say board. You can have service tech check this out. There is only so far you can go without knowledge of Controls ad electricity. Russ ... Air Conditioners

I have a TCL 2.5hp split system air conditioner (model TAC24chs/g) that wont cool or heat...only blows room temp air. The outside fan is working and i have cleaned the filters.No water is dripping from drain pipe.


I will star checking freon pressure but you going to call an HVAC company to do that. Please turn it off or you will damage the compressor, if is not already. ... Air Conditioners

I purchased a AMCOR portable air conditioner Model ALD12000E/EH on Mar 30 2009. This unit does not heat or cool only the fan works. When the unit was first received the heater worked fine although there was a strong odor associated with the heat cycle. I am not sure if this unit is worth the cost of repair. Can you make a recommendation?


Hi path531,Do you have any further inquiry about the system? Hope it helps.Thank you for using FixYa. ... Amcor Air Conditioners

The fan on my Carrier central air conditioner a/c model 38ER036300 does not move when the compressor kicks on. The unit will heat up and then will start. It also will start when I give it a small push. The 30 amp circuit breaker will also vibrate for about 4 seconds and then will be fine. Should the fan blade move freely when the unit is off? It seems to have resistance. Does it need lubrcation or is it a sealed bearing?


Hello YES the blades have to move freely.If it has oil ports look on the side of the motor for a YELLOW plastic plug/cap there are 2 one at the top & one at the bottom.Pry them off/loosen with a small screwdriver & squirt #20 oil in the holes ... Carrier 38BRC060 Air Conditioner

A detailed question is important to get you a relevant answers