Having problems with your Air Conditioners ?

I have a thru the wall fedders ac unit. The heat stopped working when you turn it on it just hums.


Answers :

No blower !!! or heating element is bad or switch try putting the fan on only if it works than it is probaly the switch not letting the blower on only heat

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a thru the wall fedders ac unit. The heat stopped working when you turn it on it just hums.


No blower !!! or heating element is bad or switch try putting the fan on only if it works than it is probaly the switch not letting the blower on only heat ... Fedders Y Chassis AEY12F7E Air Conditioner

I have a Daikin 4mxs32 with 4 indoor 9K wall mount units. About 3 months old. All of a sudden it stopped heating or cooling in all rooms. It works in the closest room to outdoor unit. Not at all in furthest room but does work somewhat on unit directly on other side of the wall and also somewhat on unit directly on other side of wall behind closest unit. Then I also noticed that when I turn the furthest unit that somewhat works off the close unit that somewhat works goes up in discharge temp in A


... Cfm Daikin R410a Split System Air Conditioner

I have a thru the wall heat pump; arc124xxo. when i turn the thermo to cool it works, when i turn it to heat the comp will not come on.


The heating control (defrost thermostat) is locatedbehind the decorative front cover, and isfound on the right side panel of the chassis. Itsfunction is to allow the temperature range inwhich the heat pump operates to be manua ... Whirlpool Air Conditioners

One of our Fedders AEY12F7F through-wall AC/heater units has stopped heating (AC still works fine). Unit is about 4 years old. I know it has a separate heating coil (it's not a heat pump). Is there a fuse I should check first? (where?). If there isn't, or if that isn't the problem, do I assume the heater component needs replacement? If so, is this something that a skilled handyman could do? Is a manual available? If we need professional help, is someone recommended for the Portland,


Hi - there is a fuse inside the unit and if replacing it does not solve the problem, it could be a problem with the heating element itself. The heater looks like this: ... Fedders AEY12F7F Wall/Window Air Conditioner

I have a Fedders A1A10W2B in wall Air Conditioner. Was working fine last year. Turn unit on last night and ran the fan for a few then when I put in cool no cold air will come out. It will make this humming sound like it wanted to, but the air was just regular air. Any suggestions? Does it need freon?


... Fedders A1A10W2B Air Conditioner

My fedders a/c will turn on fine but after some minutes the fan will stop but the compresor will still work. i will haveto turn it off and turn it on again after 10 minutes and it will work fine again. but it will stop again.


You need to replace you fan motor. It is going bad and the amount of amps to keep it going is causing it to over heat. The next time you try it and the motor kicks off see if the motor frame is hot. Be careful I have seen the hot enough to cook eggs. ... Fedders A6X05F2D Air Conditioner

American standard thru-wall heater air conditioner (PTEC1501GAA) will not heat. When wall mounted thermostat is turned up for heat, the fan turns on but no heat comes out. I opened it up and checked the fuse which was okay. I suspect the unit is of mid-1960s vintage. I tried to locate a manual on the American Standard website but it was no help and mostly focuses on plumbing products. Ron


Sounds as if the heater coil itself is burnt out. These coils may be repaired if you can get an universial coil repair kit and rewire the heater coil yourself. Since the age of the unit is in question I don't know if it is possible to get a kit fo ... Carrier 52PQ307 Wall/Window Air Conditioner

Sharp AF-R1108X Thru-Wall/Window Air Conditioner was working fine all summer. The past 2 days were extremely hot out. the unit was working around the clock. the unit was in low cool and keeping up fine. Then it started making beeping noises and going into energy saving mode and cycling the unit on and off constantly and would not allow me to turn it off by using the selector button. I had to unplug the unit to turn it off. I left it off for about ten min. hoping it would reset it self. I turned


... Sharp AF-R1108X Air Conditioner

I have a dometic dual-therm rooftop RV air with analog thermostat. When I set the thermostat to heat, the unit will hum but the fan does not turn and no air is coming thru vents in the floor. Then unit will blow cold air (hums and fan turns) when thermostat is on cool, but it won't turn off unless I shut it off at the breaker. What could be wrong?


... Dometic Rooftop RV Air Conditioner

Have a Amana a/c heater central furnace. Model number PGA30R0452A. The a/c part works fine. The heater part does not turn on sometimes. We have to keep turning it on and off to get to work. No matter what you hear a slight humming when we turn it on just it doesn't always blow air out of the vents. It also does not always kick back on once the temp. has dropped and should start heating the house again. We have programmable thermostat. Any suggestions to whats broken or breaking. My husband woul


When you change from cooling to heating the fan will not come on immediately. A solenoid valve is energized (check that it is working) and operates a reverse valve, changing the gas flow in the system. It takes a few minutes for the system to build u ... Air Conditioners

The fan is working but the air blowing is not cool. Sounds like the Compressor tries to turn on I hear buzzing or humming for about 3 seconds then it stops. I was near the fuse box and I think some noise was coming from it when it tried to turn on - but i think most of the humming it by the outdoor unit itself. It tries to to turn on every 15-minutes or so.


You may have a bad start capacitor or windings. You really need to call for a service technician in your area to diagnose the problem. Doing it your self can lead to personal injury or cost you a lot more money to fix. ... Air Conditioners

I have an XQ08 model - thru the wall When turned on it provide cooling for approx 10 minutes (sometimes longer) and then it stops blowing cool air. My repair man came and adjusted the sensors which he said might solve the problem. It did not. the thermostat is set to 69, I have it set on 'cool', not money saver. When it stops cooling, and I turn it down to 60, it makes no difference and no sound indicating the compressor clicks on. Any suggestions would be helpful. thank you Ms Hill


Hi\015\012\015\012To fix a cooling problem in AC you must know the cooling process that the condenser (outside unit) pulls in the house's warm air and cools it with Freon. The cold air is then forced back into your home through the duct s ... Friedrich Air Conditioners

Hello :) We have a frigidaire 12000 btu in wall unit. It was working fine lastnight but when we got up this morning (we had it set to heat -on 69 degrees) it was making a buzzing sound. I have tried turning it off for a few then turning it back on. It seems as though the fan will blow slightly but the heat ,compressor nor the air will kick on. what do I need to do?? Thanks for your help !!


1. Switch off the AC first for a few hours2. Remove the power connector 3. See that the Compressor is cool first4. check the air tube and the blowers5. Reconnect the same and connect the power cables6 ... Air Conditioners

We have model # 58SXA080-JG Gas Furnace-the fan is not turning on-heat is not coming thru the vents. We had the control unit/circuit board replaced yesterday. The fan, pilot light and heat came thru the vents for a few minutes-then stopped. Can't get it to come back on..Trying to find what else it could be


Blower Control Circuit Board (Carrier, Payne, Bryant) is the faulty partInput Control Voltage: 18-30 VAC.\015\012Frequency: 50/60 Hz.\015\012Power Consumption: 5 watts max.\015\012Output Ratings:-on high contact: 20 amps resistive @ ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

The fan on the condensing unit isnt working it works for awhile and then shuts off,then the compressor starts to work by itself really hard and the whole condenser heats up really fast so I turn off the breaker and start it again but the fan makes and electric humm and I have to push start the blades to get it to spin and then it will work for awhile and then the fan will stop again after about an hour and then same thing happens


Does the fan turn freely or is it hard to turn by hand? If it is hard to turn the fan motor may need to be replaced. If it isn't hard to turn then check the fan capacitor. You can test it with a multimeter or take it to a heating and air supply and g ... Goodman CLT36AER36 Air Conditioner

My ac unit is not working properly. It stoped working the other day and we called a HVAC out. He said it was the transformer. Replaced that and put a new stat on. Then in less than 24 hours the thing stops again. Replaced the transformer again. The unit will not work right. The fan blows on the (on) position and the heater part works but everytime we turn on AC it makes a buzzing or humming sound and does not come on. If we leave it like that it will burn out the transformer. We replaced the rel


You are going to have to eplace the contactor inside of the outdoor unit, the coil is weak ... Air Conditioners

Fujitsu inverter hello my name is jim. my fujitsu works on all areas except heating. when turned on the it makes all the moves as it is about to work but stops as it is frozen with very little air coming out.it also has the timer light flashig constently and the operation light flashes 5 times every 10 seconds. on cooling , dry , fan it seems to power on and all levels of speed work ok.


... Air Conditioners

Hi my name is Tony and i attended a site with a sharp wall mount split, don't have indoor details but the condenser is a AE-X099E R22 unit. the problem is that on heating the system works fine for about an hour then the indoor fan stops and the yellow light flashes on and off at the same time the compressor stops and the outdoor runs for a while before it stops. any ideas.


... Sharp Air Conditioners

My whirlpool ac/heat window unit,cools the right way. When i turn on the heat it works for 30 min/1hr then the heat stops and blows cold air. Is that the therastat,heating coil or what?


Thet have thermostat discs in them that fail. probably need a tech ... Air Conditioners

Honeywell central heat & air unit--wall thermostat not controlling it--will not work--thermostat only lights up -aux- and screen goes blank...worked previously...replaced relay and thermostat---still same thing. Why would the thermostat just stop working?


... Honeywell ER150B Air Conditioner

Hi, I have a Halstead combi boiler. The Central Heating works OK, but we are not getting any hot water. It cycles between luke warm for a bit and then goes cold. Not sure if it's related but occasionally the heating also stops and this is due to the water pressure having dropped. Turning the pressure back up to 1.5 bar starts the central heating again, but does still not give us any hot water.


... Air Conditioners

Carrier Thru-Wall Heater and Air Conditioner won't heat


Http://www.residential.carrier.com/support/troubleshooting.shtmlHere is some troubleshooting tips.Also service available. ... Carrier 52PQ307 Wall/Window Air Conditioner

I have a problem with my central heat / air unit. As it is getting cold now, I am using the heat. My problem is that I must turn the thermostat to the on position to get the unit to come on. In the auto mode, nothing happens. I can get very cold but not ever kick on until I move the switch to the on position. In the on position it works fine. Thinking that my problem was with the wall thermostat, I replaced that. I do not remember having this problem with the A/C. What should I look for to fix t


Look on your thermostat one switch (for the fan) will say off/on/auto. The other switch (for operation mode) will say off/ac/heat. The switches should be set at fan auto and mode heat. Some have an auto for the heat/ac if that is the case your thermo ... Air Conditioners

I havent got a clue how to work the new central heating with a Altech thermostat on the wall. Dont want to turn off the heating incase I cant put it back on ...Bloody roasting


... Air Conditioners

The outside compressor and fan will not shut off. I have turned the thermostat system to Off and even to heat, but it will not stop. I went on a trip, increased the room temp to 80 on the thermostat and left. When we returned 2 1/2 days later, the coils were frozen and no air was comiing through the vents, even with the blower motor working. So I turned the unit to furnace and melted the ice on the coils, but had to pull the fuses on the outside box to get the compressor to shut off. Is there a


Sounds like the contactor is stuck. That's why nothing will stop the fan and compressor except killing the power to it. You should be able to get one fairly cheap. ... Ruud UAKA037 Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1151 seconds