Pan missing when RUUD unit was installed causing problems with AC

\015 Need to know the part so that I may order and have installed not sure exactly what it may be called. It is causing condensation build up and the a/c does not work as well.\015

Answers :

I think your talking about an emergency drain pan. Is condensation building up on the outside of the unit? If it is, it means that the unit is not draining properly and the is too much water sitting in the main condensate pan. If you don't have the emergency pan, then the condensate drips from the unit onto the ceiling in your attic. I'm assuming a lot of things but this is what I think you are asking. You will have to find an ac supply company that will sell you an emergency pan and then it must be piped to the outside of the home or it can be plugged but with the use of a float switch. This switch will shut the unit off if the main condensate drain becomes clogged. You should have a professional come and wire a float switch unless you are knowledgeable about a/c equipment. I hope this answers your question.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Pan missing when RUUD unit was installed causing problems with AC


I think your talking about an emergency drain pan. Is condensation building up on the outside of the unit? If it is, it means that the unit is not draining properly and the is too much water sitting in the main condensate pan. If you don't have th ... Air Conditioners

My 6 year old Heat pump RHE 60 on days when temp. gets up to 85F the Compressor struggles to come on some times up to 10-15 minutes.A hard start kit was installed when unit was 5 months old for similar problem but later they (service people) found it was caused by a burnt wire. I dont know if they left the hard-start kit on unit or removed it. I cant get installing dealer to find me a fix for this problem .


Hi,One of the methods to curb if the compressor is not working is " Installing Start Kit".There might be many reasons.Let me write main reasons :-\015\012\015\012\015\012Compressor will not start some or m ... Air Conditioners

I have a unit in the attic that is installed in the attic horizontally. The condensation leaks out the unit into the overflow pan. I have had the drip pan replaced as it was cracked, the overflow line adjusted to insure positive drainage and no sags and raised the unit so it maintained positive slope towards the drain pan. I also made sure the drain line is not plugged by pouring bleach water down it and after a period of time, blew compressed air through it. What else could be the problem.


It sounds like to me that the leak is coming from inside the unit(air handler) possibly your evaporator coil is icing up and causing a build up of water just below where the 3/4" P.V.C. drain line connects. Instead of draining out the line, it is fin ... Air Conditioners

I had a rheem r-22 old system that has been replace by a Ruud R-410A. This unit is always wet outside.The company that installed the unit, according to them they have move the bold inside of the unit, then they raised the pressures to 150[?], then they sealed the unit in the inside with some grey paint. Im still having the same problem with the unit sweeting alot. How can this problem be solve.


Is the unit outside the one sweating ? If it is that means it is working really well. Pressure should only be set by maximum efficiency and nit to change condensation. ... Rheem Air Conditioners

Have a Ruud AC unit the problem I have after installing a new condenser fan motor when I throw the circuit breaker the unit will not turn on but when I push the contacts on the contactor in manualy the fan will come on but the compressor will not.what do I need to do or order to make this unit work ? I did turn it down to 74.Can you help ? THANKS


The contactor engages from low voltage power from the thermostat as does the outside condensing unit. You may have blown the low voltage transformer or have a loose thermostat wire. Check line voltage(220 volts) to the transformer. Check load voltage ... Ruud Central System Air Conditioner

We've had problems with a Laars Neotherm NTH105 since it was installed. The flame sensor seems to be not sensitive enough and unit shuts down. When the sensor is cleaned it runs for a while, but the same problem comes back. I was told that there was a retrofit kit because they had this problem occasionally. Is this true and are there any other probable causes for shut down with the Neotherms?


Yes there is an upgrade kit for the NeoTherm which allows the control to read a lower flame threshold signal even if the flame rod becomes a little dirty. Please contact our technical support department at Laars Heating Systems 1-800-900-9276 ext 4 f ... Air Conditioners

Have two new 5 ton Infinity air conditioning units with gas furnace in residential installation. Repeatedly getting "change filter" warning. Indicated CFM is 1400 on high cool. This seems low to me. Shouldnt the CFM be closer to 400 to 450 CFM per ton? Could the problem be caused by undersizing the ducts? What CFM is recommended for the 5 ton unit on high? Hank Haeseker, PE


Hi,\015\012Yes, you are correct... the air flow should be at least 400 CFM/Ton for good efficiency. 350/ton if you have a dehumidification mode....\015\012But under 300 is totally unacceptable...\015\012The problem probably is the d ... Carrier Air Conditioners

We just installed a Samsung AQ12ABMCF heat pump/ air conditioner. Cooler setting works fine but when switched to heat mode nothing happens (outside unit runs, but inside unit does nothing). Anyone had this problem, or is there something that we are missing? Thank you!


I am having the same problem with my unit. it was working for a few years but this season it stopped ... Air Conditioners

I have a trane unit in the attic that is for the second floor and it is installed on i guess its side has to be that way water is comming out of this hole and into this pan that is connected but the pan keeps getting full of water what is the problem


The water is condensate, which is produced by the air conditioner (this normal), The hole you are refering to shoule be connected to a drain, and should have a "p" trap installed to allow proper drainage and prevent sewer smells from backing up into ... Whirlwind FH-778 Air Conditioner

My AC unit is installed today,but right from starting its suction grill i.e the middle portion is not providing any air/coolling effect. Only the side vertical deflectors are blowing air. What could be the possible cause?Is there any problem with installation or with the settings. I am running AC in powerful mode for quick cooling .


If it has quick cool on the ceiling assembly, one side slides open & closed, and the larger area is (where your filter is) is for intake air ( return air).If it is quick cool ceiling assy, try closing off ends by rotating them, then slide g ... Air Conditioners

I have a Intertherm split a/c heat unit. I have water leaking out of the indoor coils into the blower compartment which cause me to replace the blower unit and cap. After cleaning the coils, drain lines and verifying the pan is not cracked or broken it still is leaking into the blower compartment. Almost like it is sucking the water right off the coils. What could be the problem????


Drain could be clogged not letting the water run out did you clean both under the coil and the top of the coil if you did all this I would turn system off lift coil slightly and fill pan with water afer i got it completely dry this will show you wher ... Intertherm P3RA-060K Air Conditioner

Hi there, I have two Fujitsu DC Inverter split units to heat my flat (england). The temperatures have dropped significantly -2 and below. This causes the outlet pipes to freeze up and when the units are on defrost the excess water gushes out of all other joints in the units. This causes two problems - the units are wall mounted one on top of the other, so the top unit freezes the bottom unit. The second problem is the bottom unit 'dumps' in on the floor of the area which when defrosted s


Normal cool temp 23 to 25 and heat mode 29 to 31. And regrading defrosting your pipelines no need any tray. You can insulate with Armaflex tube which is mostly used for best insulation. Hope there won't be further water leak. ... Air Conditioners

Electrical Schematic?? Hi, Here is our problem:  We have this unit installed in our desert vacation home in the wine "cellar" room, at times when we are not here, the electricity has gone out (even just for a second) and this unit shuts down and doesn't come back on until we come here and physically turn it on again. We are looking to bypass this so we don't have wine ruined while we are away.  How can we get this unit to come back on by itself?   Another problem is: this unit is installed in su


An easier solution would be to connect it to an UPS. May not be the cheapest though. ... Hitachi RAS-09UH Air Conditioner

I have a Bryant split unit. After incurring some water damage that I assumed was from the overflow pan (the damage came from a poorly insulated elbow in the duct that was sweating) I opened the unit and found the condesate pan dry but the interior was completly saturated. I watched as condesate dripped off the coil and the supply fan would pull the drop and miss the pan entirely. Now I have mold/mildew forming in the unit and the insullation inside the unit is wet. I turned off the ac and left t


Most all brands of air conditioners are built along the same lines, and for the most part are equally well designed/constructed. Bryant AC's in my opinion are as good as any - and - although - I don't know all the facts about your problem - I do kno ... Bryant 463AAC008BA Air Conditioner

Furnace shuts down before heat temp meets thermostat. Furnace unit starts frequently. Service installed new limit switch and a new circuit board but furnace unit continues to malfunction. Same problems after service as before limit switch and new circuit problem installed.


Has any one checked your thermostat. as soon as the furnace shuts down then turn up the stat and see if it starts right up. i would think the stat function should have been checked also. ... Air Conditioners

My frigidaire air conditioners spit dirt all over the floor. My window unit and my through the wall unit in a sleeve both do the same thing. I called Frigidaire two years ago and they told me there were no reported problems. I keep the filters clean and don't know what is causing this. My rugs and furniture are full of dirt particles when I use these units. I have had air conditioners for many, many years and have never experienced a problem like this. Please advise me if this is a problem with


1. Turn units off\0122. Remove Filter\0123. Spray a foaming cleaner on the coils (Dow Bathroom Cleaner)\0124. Use a spray bottle filled with plain water\0125. Replace Filter and Grill ... Frigidaire FAC124 wall/Window Air Conditioner

My parents had a frigidaire eletric heat pump installed 2 years ago. almost right away a soured water smell came out of the vents. service tech sprayed the coils and installed a black light. did not help. service tech said frigidaire did have this problem with some of its units. so the unit was replaced. new unit done fine for about 6 months. now the smell has came back mainly when the cooling is on. any suggestions. i dont believe it is the unit. they had a gas it pump before.


I feel that the gas lis leaking from a very minute hole which gets enlarged when the unit is cooling (it gets hot and enlarges). And it could be leaking from anywhere. A quick temporary remedy is to seal the possible leaking points with super glue or ... Frigidaire Air Conditioners

Hi, we have a problem with our Weatherking heating unit/ air conditioner. We had it installed 07/20/06. It really never has worked properly. For the last 2 summers in run's constantly. Which of course makes our electric bills outragous. Our house is around about 2200 square feet. This unit is a 4 ton unit. What could be the problem. Please help. Thank you. The model # is 13AJA48A01


Lets look at the whole problem. Did you have a new unit inside. Is the charge correct for unit. 1 lb of refrigerant makes difference. Four tons should be big enough if you have proper insulation. I have three tons in a 2100 square foot house. Its ple ... Weather King 12AJA4801AH Air Conditioner

Hello all I am about at my wits end....We had a 2 ton 14 seer Ruud heat pump installed at the end of last year. The biggest problem I am having is in heat mode when it goes into defrost it makes a loud almost helicoper sound for about 20-60 seconds, wakes you up that's for sure. When I have had the company that installed it come out I can never get it to do it for them and I even tried recording it. We have had a multitude of problems I believe mostly stemming from the company that installed it.


It is most likely due to a scroll compressor. these are very noisy and hard to get used to. if it does not have a compressor jacket it would be worth installing. a hvac company would have to get it for you and it put it on. labor should be minimal si ... Air Conditioners

I recently had a new outdoor unit installed on my central heat and air conditioning sytem. I have had the installer out 3 times and the system still does not operate correctly. Sometimes when it cycles (every other time or every third time) the unit does not blow cold air. Sometimes the unit comes on not blowing cold air and the compressor fan is running but not the compressor. Sometimes after 15 minutes of this the compressor will come on. What is the problem.


It sounds like the compressor needs starting components installed on it. All a/c units have a run capacitor for the compressor and another one for the condenser fan motor. These motors use these capacitors all the time when the motor is running. H ... Air Conditioners

My air conditioner evaporator housing appears to be clogged. The normal drain line goes to the sewer. When it is not draining properly, a back-up drain line coming from the same evaporator housing, drains to the pan (below the unit). Then the pan drains to a visible outlet on the roof (which signals the home owner that there is a problem). We noticed the roof drain line was draining last weekend, so we checked the pan under the evaporator unit, and it had water in it (which is not normal


If you are sure that it's not the line, you are going to need to get to the drain pan to clean it. Take the cover off (with power off) to access it. It's not that muchto get to it. Use a drill and a socket. Once you get in there you will ... Air Conditioners

I have had a mitsubishi split system HVAC installed in my 150m apartment. It is installed inside the apartment in a small space with one window for inflow a second window for out flow. As we test the unit, 3 problems have come to our attention. (1) When it was really cold outside last Janaury the unit itself was leaking something that turned into ice. There was a pool of about 2 inches of ice on the floor and the wall had a covering and the hoses were encased in ice. The installer maint


The problem is in your Ac's compressor .It is wasting all the cooling gases and chemicals1)the ice you are seeing is the mixture of chemical & gases when get in contact with atmospheric air it converts into ice and pls dont touch that ice a ... Mitsubishi MS-A09WA Split System Air Conditioner

What causes the drip pan under the furnace in the attic to keep getting fill with water? Once I get all the water out of the drip pan the air starts to work but in a couple of days it fills back up. Should I try to clear the PVC pipe at the bottom of the unit connected to the drip pan or the PVC pipe running out of the middle of the unit?


Yes the drain needs to be cleared,use air pressure if you can,and hot water afterwards,this will do the trick,I hope this was helpful,thank you. ... Air Conditioners

Details I have a problem with a Goodman Model GSH130601AA, ( 5 Ton, 13 Seer heat pump) central air unit, installed 06/15/2006. (I know, I saw online reviews but unit was put in before I saw negative e


The fan motor is bad and needs replaced. Depending on how mechanically inclined you are, you can replace it yourself fairly easy, the hardest part being the fan blade without a hub puller. Just take your old one in with you to a local A/C supply stor ... Air Conditioners

Locating Ruud Central Air drain pan?? Water has started dripping through the ceiling from the Ruud Central Air Unit...can't find drain pan?


The drain pan is physically inside the indoor unit.\015\012\015\012grab a 1/4" nutdriver and open the bottom service panel your coil and drain pan is there, you won't be able to remove the coil properly but you could see if the system is ... Air Conditioners