Ruud heat pump initial startup,both guages shoot to over 300 lbs

\015 Comp.shuts down on overload if you don't pull disconnect. new install with spacepak\015

Answers :

Brand new install...did you open the refrigerant lines to release the refrigerant?

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Ruud heat pump initial startup,both guages shoot to over 300 lbs


Brand new install...did you open the refrigerant lines to release the refrigerant? ... Air Conditioners

I am trouble shooting a Bryant Hi-bred system that uses an air cooled heat pump with high efficiency gas furnace for backup and low ambient operation. How does the system decide whether to use the air cooled heat pump or the gas fired high efficiency furnace. It appears to be outdoor air temperature related, but I can't find the setpoint for it. The main zone Bryant thermostat appears to control the system, but it doesn't always bring the backup heat if the heat pump doesn't function.


If you are using honeywell vision pro 8000 t-stat you need an outdoor sensor program on t-stat would have to look up ... Bryant Air Conditioners

I have a Lennox model CB19-51-1P air handling unit with HP19-511-1P compressor heat pump unit. I just turned the heat on for the first time this season. And I am getting low heat volume. The heat pump unit is running for long periods. I am getting enough heat to maintain the 70 degrees setting with constant cycles, shutting off for short periods, running long periods. When the thermostat is turned to a cooler temperature, the unit shuts off as it should. Could you please help trouble shoot po


First thing you need to check is if the reversing valve is working you maybe running your A/C with the heat strips on depends on the t-stat your using some heat pumps will bring the strips on with a high d ... Air Conditioners

Heat pump goes str8 to heating strips compressor does not run in heat mode pump was manufactured in 03 installed in 07 and has sat dormant till now could it be wired wrong it is a ruud split unit with digital non-programable 2-stage heat and cool t-stat


I think that you have the right idea. The wiring is probably wrong. If you can trace the low voltage wires to the air handler. make sure that the Y1 wire on the t-stat is going to Y1 on the hair handler and then to the condenser. The Y2 wire should b ... Air Conditioners

Aux heat always comes on in heating (Ruud heat pump)


What type of system is it, if it's it Rheem the o/b needs to be set for B, if not check the freon charge, or thermostat, there will be a point where the aux. heat comes on when you turn it up, poss. only 4 degrees, is it a mercury stat or digital ? ... Ruud UAMB Air Conditioner

Ruud Heat Pump blows room temp on Heat and AC setting


A "Heat-Pump" is also known as a reverse cycle air conditioner, this means on heat the outdoor unit acts like the indoor section and vice versa. So in all probability you need to have it leak checked and recharged. ... Ruud UBHC Air Conditioner

I have a Carrier Weathermaker Infinity furnace model 58MVP100-F-1-20 with 3 zones and Carrier Comfort Zone II programable thermostat. I recently installed ageothermal heat pump system which includes a hot water coil in the furnace plennum. The heat pump is sized to meet loads except for the coldest days of winter - (below 0 F) - when the gas furnace is expected to kick in. My problem appears to be the Weathermaker's characteristics don't accommodate the low heat /slow response provided by


Http://www.hvac-talk.com/vbb/archive/index.php?t-85094.html here is a site i found very useful ... Carrier Air Conditioners

Problems with a new Ruud heat pump "wiring"


Hello and welcome to FixYa!,It sounds to me like there may be a fault with the Furnace or that the Furnace is not compatible with the Heat Pump.It may also be a faulty Heat Pump.Hope This Helps, --P3NGYJ03 ... Ruud UBHC Air Conditioner

I have a ruud heat pump that tries to run aux heat


Hi, This sounds like it is cold enough, the ambient temperature outdoors and is bringing on the aux heat to help even at 1 degree. Nothing to be concerned about the energy you may use will be next to nothing.In the program of the stat as ... Ruud UBHC Air Conditioner

Rudd upmc024jaz I have Ruud heat pump model UPMC 024JAZ, the air condition works great but the heat pump comes on runs for a minute or so and the compressor goes off. you hear a hissing sound from the compressor like pressure being released.


... Air Conditioners

My sister has a Ruud Achiever High efficency heat pump Model UPLA-049JAZ Serial #6408-M389910353 they just moved into this house in ND and have no information on this system..Over the winter it was very loud outside and they discovered alot of ice frozen on the fan blades and under but inside the unit. Where can they info for this unit and any suggestions on the freezup problem. Owning a heat pump is entirely new to them


There are 3 possiblites \012\0121. you have a bad defrost board or defrost sensor. \012\0122. Your low on Freon.\012\0123. Your coils and/or your Filter is dirty. ... Air Conditioners

Ruud 300 thermostat in heat pump mode and I don't have the manual to get it out of that mode. It was working fine then switched to this mode. No more cold air. I live in Florida so I don't have a heat pump installed. I remember I had to switch to Electric mode but its a buncha codes. How do I switch it? Thanks


Hi,\015\012Here is the complete manual for your thermostat...\015\012\015\012Click here\015\012\015\012 ... Air Conditioners

Just had new ruud heat pump installed 5 days ago, it blows cold for the first few minutes and then warm but not warm enough, called installer he said thats the way heat pumps work and he will stop out when he can, can u shed some light on this problem. thanks


In most newer operations, the indoor fan motor will come on first before the actual heat comes on.\015\012However if you shut off the power and Remove usually\015\012the upper panel. Located on the inside on the right hand side there is i ... Ruud UBHC Air Conditioner

Ruud heat pump outside unit not starting. Open and found contactor disengaged even though I have system on from inside. Low voltage wires come out of a circuit board checked for 24v, none. Then bypassed board by unplugging same yellow and brown wires plugged into the board and exiting but now I have 24v getting to contactor but it does not engage contactor. What could the problem be. I know a little a/c but these heat pumps are very complicated. Help please, I want to learn.


If you are getting the low voltage to the relay and it is not closing, then the relay may be either bad or stuck. Disconnect the 220v and see if the contacts can be manually closed. I always use a piece of wood or something non-conductive. If the ... Air Conditioners

I have a RUUD 13pja42a01 heat pump. The main breaker in the house was turned off about a week ago. We have not tried to turn on the AC until today and the outside unit will not come on. The main breaker in the house is on as well as the heat pump breaker. I was looking for a reset button but cannot find one. Also in the box outside connected to the unit it does not appear that there is a breaker in there.


Check the small wires going outside to the contactor for 24 volts. If you have 24 volts then mayb ... Air Conditioners

Heat pump trouble shooting fema trailor i have a az75h18dacm1 self contained air cooled heat pump that wont work. cant find any info on this unit. have replaced the stat,the fan comes on only if it want's to


Normally the Fan only comes on when it is called for by the compressor, here is their web page that you can go to and pick your model and get their trouble shooting guide to repair your system, they also have a 800 phone number to help you. I am fami ... Air Conditioners

Ruud heat pump model series pca high pressure cut out


... Air Conditioners

Ruud heat pump high pressure cut off problem


... Air Conditioners

I am thinking about purchasing a Ruud UANL -024JAZ Condencing unit, Ruud UPNL-024JAZ Heat Pump Condencing unit and Ruud UHSL - HM2417JA AC condenser for use in my house. Is Ruud a reliable/dependable product line?? Is Ruud's reputation for quality as good as Trane and Goodman units??


All brands have issues at some point. You should be satisfied with RUUD. ... Ruud UBHC Air Conditioner

Hi: Last week, a contractor installed the above-mentioned new 16 seer heat pump, an air handler and a heat kit. Our house has 3 levels, each about 800 square fit. Initially the house would not heat above 56 degrees. Therefore the contractor drained 2 oz of Puron gas from the line, then decided to put 0.5 oz of Puron gas back in. The temperature is now rising to the desired temperature. However, it seems to be rising rather slowly, i.e. 1 degree per hour while utilizing the auxiliary heat (w


That is worrysome about putting refrigerant in hap hazzardly... There is a math style process involving pressures and temperatures in two locations that dictate how much ref. goes in. Anything else shows clueless installer. Too much or too little ref ... Air Conditioners

RUUD 13 SEER HEAT PUMP MALFUNCTION 2009 MODEL


Unsure how long ago you purchased this unit, I can only respond to what I have read. I, as a homeowner, would not PAY a contractor until such contractor has properly INSTALLED and successfully TEST-OPERATED said unit/system in ALL MODES to the comp ... Air Conditioners

Ruud heat pump question


Does the air handler take a minute or two to start, this would be normal so that it doesn't blow cool air into the house before the unit is warmed up. If not could be the fan relay is weak and needs replacing. As far as the outside unit it sounds lik ... Ruud Air Conditioners

RUUD 14 seer heat pump makes loud squeeking noise after cycling.


Your problem is the TXV. I just had person with the same problem. Replace TXV no problem Rusty ... Ruud UAMB Air Conditioner

2 month long issue...RUUD Achiever 1.5 Ton 10 Seer Heat Pump


Rather than have him replace the control board first, ask him to remove all the freon and weigh it. He then can reuse the Freon that came out of your system put back in at the exact charge that the rating plate calls for. He will add a bit more to co ... Ruud Matching Split Air Conditioner

New Ruud 16 seer central air and heat pump - very noisy


A few things to check\015\0121) Is the unit mounted on metal brackets attatched to\015\012the house, is so I would probably put rubber pads\015\012between the unit and the brackets to absorb the\015\012vibration.\015\012 ... Ruud Matching Split Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0855 seconds