Rudd Furnace under-achiever 90 no lights nothing power going to unit and 3 amp fuse check out OK! I had the board, and blower replaced today ran for about two hours and now nothing again!Same problem! Help.


Answers :

You say you have power but what is the voltage? You said that that you are using a 3 amp fuse so you are referring to a gas unit. Ok, have you checked the safty switch that is located on the blower cabinet, the one that the door sits against to make sure that you have power leaving the switch? Also, on some units, there is a limit switch that come directly off of the above mentioned blower cut off switch that when tripped, will cut main power to the board. Its located on the inducer or on the flu pipe, but mostly on the inducer houseing. Make sure that all your manual reset limits are reset. But check the switch first and then work your way to the limits. This is the only thing left and was probably the probablem before you replaced the board. If you have any more questions, please respond to the thread.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Rudd Furnace under-achiever 90 no lights nothing power going to unit and 3 amp fuse check out OK! I had the board, and blower replaced today ran for about two hours and now nothing again!Same problem! Help.


You say you have power but what is the voltage? You said that that you are using a 3 amp fuse so you are referring to a gas unit. Ok, have you checked the safty switch that is located on the blower cabinet, the one that the door sits against to mak ... Ruud UBHC Air Conditioner

Just cut on 8 year old Goodman CPLE24-1 AC for the summer. Ran 8 hours fine, Next morning noticed outside unit running, very little cool air blowing out of inside floor vents (like the blower fan was broken). Outside unit frozen. Capicitor replaced last July. (2) separate filters inside house returns clean. Whatz the problem? Help? Advice? Gotta fix it fast! By myself hopefully. Thanks!!!!


Due to the many different questions I see about Air Conditioning, I am including this overview to help us better understand each other for trouble shooting. A basic air conditioning system has a Thermostat, Air Handler or Furnace Fan and a Condensin ... Goodman CPLE24-1 Air Conditioner

I''ve been working on this thing for three weeks now. It is a Dometic Duo Therm model 57915.531 roof top ac on my rv. It will not run. This is what i have done so far: replaced the thermostat, there is voltage to the thermostat; there is voltage to the unit. I replaced the circuit board today (took two weeks to get it from Dometic)but nothing. I don''t know what else to do. It has a new thermostat and a new circuit board. Other than the two capacitors on top at the compressor there is nothing el


Check the compressor winding resistance from common to start \015\012start to run\015\012run to common \015\012the two lowest should equil the highest\015\012also check shorted to ground \015\01 ... Dometic Rooftop RV Air Conditioner

I've had to replace the blower motor on an old GE electric furnace three times in the past year. The first time the motor just stopped working. So I replaced it with an A.O. Smith motor for the summer. It worked just fine during the summer. Winter comes along, switch the thermostat to heat and the house fills up with light smoke with a smell of burning plastic. I replace it again with the same brand and model # along with a new capacitor. It ran fine for about an hour or two, then it began to bl


This is definately not a good thing. This unit is a safety hazard to say the least. Check for recalls by reporting it to the consumer product safety. ... Air Conditioners

I have a Goodman Model number AR24-1 unit and the blower moter will not start with it turned on to fan or cool or heat. I have checked the thermostat and the unit runs outside. Just no blower. Can I jump the blower motor as I replaced the capacitor today. Hear are some numbers that may help. Part Number #15212-50 Volt 208/240 Amp 1.5 HP 1/5 No heat Kit It has a Goodman switch board # B1370735 that I can check with my meter if needed. I have checked the thermostat in the attic also. Seems like


... Air Conditioners

Ok so I have know replaced the control board air handler board today the unit also has a new transformer and a new blower motor and the heating elements test good not burned at all and it still continues to burn the 5amp fuse out worked for about 30mins now blows fuse out as soon as new one is inserted and breaker turned on....I'm lost and have no other ideas with all new parts this should not be happening, Can anyone Help!!!!!


... Carrier Bryant Control Board Air Handler HK61EA006

I have a 13500 Dometic roof mounted ducted AC on my motorhome. I have changed the Board twice and the thermostat once and the same problem occures. When you first put the AC on it works fine until it goes to recycle and it kicks off and will not come back on until it deceides to. It might be a hour or several hours. Then when it kicks off it does the same thing. We have checked everything and nothing on the unit is getting hot or is burned. Please help.


May need start capacitor and relay (called start kit) or some of the compressors have a thermal overload under the compressor cap. If it's a thermal overload, it has a bimetal disc and when it reaches a set temperature (hot) the disc will warp openin ... Air Conditioners

I have a Coleman Presidential 7670 furnace in a mobile home. customer said it came on a couple of times by itself. I ran new wire, fan won,t shut off. Replaced fan switch, fan still won't shut off. Replaced t-stat, same problem. This is an older unit and has no board it has a fan switch a low limit switch, i,m guessing the other is a high limit and a fan relay. I have no schematic and am very frustrated can anyone help me please. Thanks. Brian from california


Brian, it sounds as if possibly the fan relay is stuck however, if the fan will not shut off I would suggest the following, Follow the wires from the fan to the relay on the relay disconnect the fan wire there and see if the fan shuts down if so t ... Air Conditioners

Haier Portable CPRB08XCJ 8000 BTU A/c just installed today. Not even a really hot day. Ran it for 5 hours and temp went form 82 to 77, which was fine. However, there is a puddle of water under the machine and the rug is soaked. It is supposed to have self evaporating and not need to be emptied. this is brand new, so I don't think dirty filters, coils etc are a problem. What do I do now? Plese help!


You're right - this unit has 'self-evaporation' of it's 'condensation water.'\015\012\015\012Problem is - the water is 'not draining correctly into the pan.' If you turn off all power to the machine and look into it - you will find a pla ... Haier Air Conditioners

Blower fan stays running. Fan relay attached to small circuit board (coil tabs [timer?]). Capacitor on small circuit board had ''fallen out'' of ic board. Tried to get replacement board, and was sold just a standard relay - told that relay alone replaced the previous relay -and- circuit board configuration (?). Problem still exists (no change). Also changed thermostat just to eliminate as a possible cause, but seems like problem must be in the fan relay area. Question about the wires attache


... Carrier Air Conditioners

I have a daikin split air conditioner after been on for 10mins it flashes L1 and cuts off,we have been waiting 4 weeks for Blueline to replace the boards as they said that was the problem since they replaced the boards the L1 still flashes and it cuts out nothings fixed hmmm frustrating and hot we were told by Blueline to think ourselves lucky because frogs have caused the problem and that doesnt cover the warrenty please do you have advice on a L1 and is it true that frogs can get in and caus


Very simple. Please follow these steps.1. Power off. 2. In three phase compressor terminal or in terminal block-interchange any two wires.Now power on and start. Hope, you will be happy. ... Cfm Daikin R410a Split System Air Conditioner

Coleman mach fan runs fine but A/C hums intermittently like it wants to start but won't. I'm running it with a Honda 2000 generator. Generator ran out of gas, when I restarted the generator the A/C would not run - stalls out the generator. I replaced the start and run capacitors on the A/C, hook up the generator and it ran fine until the generator ran out of gas. The A/C would not start up only hum intermittently - same problem as before replacing capacitors. Waited several hours with the fan on


The issue with the generator that gets low and high when it start running out of gas that effect the A/C and result of high voltage getting to the unit and burn the capacitors and it should by saved by the fuse make sure that the gen not run out of g ... Coleman Mach III Air Conditioner

I have an Amcoraire model AOS091HX that also displays an F1 error code. Fuses were blown on the outside unit. I read about the fix by replacing the capacitors in the middle of the circuit board. I contacted Pridium and was told the circuit boards from China have been on order for six months, so I have nothing to lose by replacing a capacitor or two. Any other advise would be greatly appreciated.


... Air Conditioners

I don't know what model my fan is, but it's only 3 years old and suddenly two days ago the light and fan quit working. We replaced the light switch on the wall-nothing. Took apart whatwe could of the fan to look at the wiring-all intact. We then replaced the battery in the remote and it instantly worked fine again. After putting it all back together it stayed lit with the fan working for about two hours at which time I turned it off using the wall switch. I immediately tried turning it back on a


That may be, because you were using the Remote Control to operate it, but then turned off the wall switch instead of turning it off using the Remote Control.Turn the wall switch back On and try to get the Remote Control to take back over ... Hampton Bay Air Conditioners

My goodman cental air system is having problems. First, the blower inside (furnace) keeps running for hrs after the outside condensor shuts down. Now, the condenser blower motor wont operate at full speed. I have replaced the motor and capasitor with no changes. Can anyone help with these problems???


The cause of your indoor fan running all the time or for long time after your heat pump has stopped heating is the fan delay relay. It has welded its internal contacts together. If you take off the side below the control panel, the fan delay relay ... Goodman CLQ36AR49 Air Conditioner

Dometic Duo therm RV a/c rooftop unit. 15,000 btu with heat pump. model 620515. age 5 years. Problem- will not always stay ON. Starts and cools fine. but shuts off within 5 mminutes sometimes.. or will run for hours and hours with no problems. when it stops, I can sometimes restart it by cycling thermostat.. if that does not work I can unplug thermostat from 12v power and then it starts when asked to. Have replaced computer circuit board and wall thermostat.. no change.


... Air Conditioners

Have 20 year old split carrier system, tried to turn a/c on today nothing, no fan, blower, do have power to a/c both in and out. Any help


I assumed that when you say AC power is both in and out, you mean both the indoor and condensing unit has AC power. Check if the unit is equipped with in-line fuse. If not, and you have a rotary switch, try to check the terminal continuities. If it i ... Carrier Air Conditioners

Blower fan runs continually with the thermostat removed or installed. This is a older carrier combined unit with a furnace. Control board installed is a HH84AA 011. Replaced the board with a new board and problem continues. Tried to find a fusible link, with no luck. No power to R and C. 120 v on PR-1 to PR-2 and 27 v at SEC-1 to SEC-2. Any suggestions? Bill


Your sensor to the fan is stuck in the closed position. This sensor kicks the fan on when a certain temp is reached in the heat chamber. It opens after cool down and apparently is stuck closed. ... Air Conditioners

Two out of four elermants not working Dimplex XLSN? Dimplex XLSN storage Heater Hi Can anyone help please? The storage heater has four elements, I noticed only two were working, they where the two starting from the control panel end. I removed one of the elements that wasn?t working and replaced it with a new one the new element didn?t heat up when the power was switched on, anyone know what the problem may be. Thanks Tony


Hi,If you know that the element is not working and the element is new then you need to use an electrical meter to trace down the power and see where it is stopping at...My feeling is that you have a bad relay and that is your problem. ... Air Conditioners

Have six year old Bryant electric furnace with heat pump, no gas. Old blower motor was going out and replaced with another generic blower motor. Wired the new just like the old and changed capacitor. There are some differences between old and new. Old says "Volts 208-230" and new says "Volts 115." Problem is blower turns on and of, over and over again. Help?!?


Hi,\015\012You totally have the wrong motor....you need to get a 208-230 motoro on there for it to work... in fact you probably already have ruined the 115volt motor...the voltage for that motor is to be 115v and you are probably running 130 vo ... Air Conditioners

HAVE A COLEMAN MODEL DRHSO601CB --- THE UNIT WILL RUN FINE FOR SEVERAL HOURS WITH GOOD COOLING AND THEN PERIODICALLY THE TROUBLE LIGHT WILL COME ON THE THERMOSTAT AND THE UNIT HAS SHUT DOWN. TO RESTART - YOU MOVE THE THERMOSTAT TO OFF WAIT 5 MINUTES OR SO AND PUT IT BACK ON COOL -- IT WILL RESTART ALMOST EVERY TIME AND RUN FOR SEVERAL HOURS. IN THE PAST IN THE PAST I REPLACED THE DEFROST CONTROL BOARD BUT WHEN I DID THAT THIS TIME IT STILL SHUTS DOWN - WHAT OTHER PROBLEMS ARE YOU AWARE OF ON TH


You may have a low pressure or high pressure switch tripping out the board as well. You might try cleaning both the indoor (evaporator) coil and the outdoor (condensing) coil. Be sure to turn off the power source before servicing this. ... Coleman Air Conditioners

I have a weathermaker SX furnace, model 58SXA060-GG, series 100, direct vent. On heating cycle it won't start occasionly, until I shut it off and turn it back on, then its fine for another few days. Both boards have been replaced, awhile ago, it was better but the problem still exists. the furnace is 20 years old. The problem is very intermittent and hard to pinpoint what is going on. If anyone could help I would greatlt appreciated it. Thank You


Hello,The board may have a fault code led light that blinks a series BEFORE you shut the unit off/on(helpful in pointing you in a direction)there may be a peephole to see the lite in the door as there is a door switch inside that will reset the board ... Air Conditioners

Had a PF code, unplugged the 4 pin probe connector and plugged it back in and fixes that problem until next PF code.....often. Ran perfect for a couple hours and turned it off for the night, when I restarted it the next morning the top blower works but the compressor nor the exhaust fan come on. I have emptied the tank, cleaned the filters, started and restarted, let sit for 10 minutes several times and tried again...compressor doesn't start nor the exhaust fan. The top blower works when on AC,


Hi,Here is a tips that I wrote\012that will help to explain why you get the PF Error CodePF\012Error Code for Appliances\012hea ... DeLonghi Pinguino PACL90 Portable Air Conditioner

I have a Goodman (AR24-1) unit, the heating is electric not gas. How do I test the blower motor with out removing it. I have a part number but not sure if it is the blower motor number or not. Part number 15212-50. (1.5 AMP 1/5 HP) 208/204 Volts) I have replaced the capacitor today but still did not start when I have the Fan switch turned on. I have checked the thermostat. Any way to check the motor? The switch board number is ( # Goodman B1370735) I can test it with my meter if needed.


... Goodman CKL24AR24 Air Conditioner

I HAVE TWO 15,000 ROOFTOP CONDITIONERS. WHEN I TURN ON THE COMFORT CONTROL CENTER IN ANY MODE OTHER THAN -FURNACE- THE FRONT A/C BLOWER COMES ON IMMEDIATELY. THE COMPRESSOR WILL COME ON AS NEEDED BUT THE BLOWER WILL NEVER SHUT OFF. I JUST REPLACED THE COMPUTER BOARD IN THE FRONT UNIT-- NO CHANGE. I DID THE SELF TEST OF THE COMFORT CONTROL CENTER AND GOT THE 'FF'


Hi Answer a little bit long.Will give you a link to help you out .(inspectapedia.com/aircond/AirFilters6.htm) .Take care. ... Dometic Rooftop RV Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"