Dakin outdoor fan always running in my split system

\015 The fan for the condensor is always running when power is on. i have to turn the unit off at the circuit braker.\015

Answers :

This is a low voltage short in wiring. You will need to divide and conquer the low voltage wires until you find it. I could be a control board but most often it's the wiring.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Dakin outdoor fan always running in my split system


This is a low voltage short in wiring. You will need to divide and conquer the low voltage wires until you find it. I could be a control board but most often it's the wiring. ... Air Conditioners

I have a Sanyo Split System the indoor unit is a KHS0921 and the outdoor unit is a CH0921. When i first turn the indoor unit ON the fan will run for a few minutes and then go off. The outdoor unit never comes ON when there is a cll for cooling. The only way to get the fan to come ON again is to turn the breaker OFF and then back ON. The Operation loght will come ON when the fan is running but it will start flashing when the fan goes OFF. What should i look for?


... Sanyo Split System Air Conditioner

SAME PROBLEMS 18k btu mini-split sys turn on blowing cold air for 3 mins, then turns warm for 3 mins then shuts down however the run lite blinks at 4 times intervals. outdoor unit fan alway runs at slow speed, even at start up. cleaning outdoor fan cleaning dont help. whats next? maybe the caps? thanks mike (us navy) at [email protected] in norfolk,va FAN MOVES FREELY, EVEN BY WIND BLOWN.


Glad to hear the issue is resolved.\015\012\015\012With regards. ... Air Conditioners

I have a Maytag S3BA-024KA Split System Air Conditioner. I have power to the system indoors and outdoors. The outdoor unit is clean and the Contactor is also clean with power going into it. The compressor is not running. I can push the contactors and the compressor fan will run but it will not operate by itself? Not sure what to do now.


... Air Conditioners

I have an LG mini split ac / heat pump system ( LAN096 ) that is only 4 months old was working great in all ways until suddenly it quit heating. I am sure it happened quickly because I was nearby when very warm air changed to cool ( unheated ) and hasn't heated since. When I shut it down and restart it the indoor fan runs right away, which is not normal and the outdoor unit will run for a minute or so then shut down and stay off. The indoor fan will continue to spin as though it is set in a 'fan


... LG Air Conditioners

I have a 24000btu ramsond split system. running for a yr, had to change out fan condensor and capacitor. now the problem started when we noticed the outdoor unit was shaking like a washing machine. then it dosent blow cold anymore. i checked the capacitor for compressor, which showed no ohms. i swapped that out and it says that it has 3.8 ohms, but when i put the meter on the ohms symbol )))), it makes that constant ring, which my father in law say is straight shot to ground. so now i dont know


Hi, you can get a proper reading with a ohm meter when checking a run cap. All it will tell you is that the capacitor is not open internally inside if you have the ohm setting that sounds off. Its not ground or shorted to ground, but look on your met ... Air Conditioners

Hi my name is Tony and i attended a site with a sharp wall mount split, don't have indoor details but the condenser is a AE-X099E R22 unit. the problem is that on heating the system works fine for about an hour then the indoor fan stops and the yellow light flashes on and off at the same time the compressor stops and the outdoor runs for a while before it stops. any ideas.


... Sharp Air Conditioners

Outdoor unit fan always runs even when indoor unit is off. I have disconnected all control wires from the headunit (at the outdoor end to rule out faulty signalling). The fan runs all the time, with just the supply wires connected. All connections to the unit are correct. Any ideas??


I have had this problem with a Fujitsu unit before. If the power is supplied to the outdoor unit first but unit is meant to have power supplied to indoor unit first, outdoor will only stop when power is cut off! In that case, you will have to run the ... Panasonic Air Conditioners

Have NEC RIH-2667 Inverter Split system.I set to Heating mode,set temp to 25 degrees.The compressor light comes on.The run light flashes for about 30 seconds.Then the vent opens,the fan comes on and starts blowing out heat.Within 5-10 mins the temp on split displays starts going up.when it gets to 26-27 the run light flashs,fan stops,no heat coming out.The temp on system keeps going up to 30 degrees.it takes approx 40-60 mins to come down to 25ish the will come on again and repeat.I have an inde


... Air Conditioners

Wont cool!! We have 2 LG 2ton heat pump outdoor systems, but I believe the remotes are cool only. The 01 system cools perfect, but the 02 outdoor fan runs half as fast as the 01 system and the compressor keeps cycling on and off, and they are hot enough to burn you. I am totaly stumped on what the proble could be.... We swaped just about everything between the 2 systems and still the 01 frezzes you out while the 02 will not cool at all.. Any kind of seguestions wold be much appreciated, Thanks i


U may have a heat pump thats not reversing into cooling. Any number of items can cause this. I would start with the reversing valve coil assuming its a heat pump. If your not acquainted with a reversing valve it is a 4 pipe (1 on one end and 3 on the ... LG LM-2430H2L 24000 BTU Heat and Cool Dual Zone Mini Split Air Conditioner

Main motor running, not blowing from system. Celestial 2.5hp split system. It is not generating any air from the system. Fan and motor are running in the outside box.


The blade may not be connected to the shaft properly ... Air Conditioners

Hyundai HSH 3001BA split air conditioner indoor fan and outdoor fan is running but compressor not running therefore checked compressor only and tested and found running. What could be the problem.


Check to see if the compressor is getting a cooling call. that will determine if it's a control issue or a power issue. ... Air Conditioners

I have an Intertherm S3BA-048KA Split AC system which has stopped blowing cold air. Indoor blower is working fine. Outdoor fan is not working. I have reset breakers (indoor/outdoor) without success. I can hear a hum coming from outdoor compressor even when outdoor breaker is in off position. I had a problem with a System Breaker last year at the blower due to condensation leading to internal corrosion of the breaker. I replaced with a "suitable substitute" (same rating), not OEM. Request


First thing I would look at is to make sure you have power at the disconnect 110 coming in on each leg to unit. Second, I would look at the capacitor for obvious bulging or leaking Third I would check to see if the contactor has burnt poi ... Air Conditioners

I have a york hvac system that is 5 years old. I have the thermostat set at 74 and when it turns on only the fan runs circulating the existing air in the house about 20 percent of the time. The ac works great when it is running but i'm wondering why it doesn't always come on. Just replaced the thermostat thinking that was the problem but it did not help. Sometimes after the fan runs for a half hour or so the ac will finally kick in and start blowing cold air. The lines are not frozen at a


It sounds to me like you have a delay on start timer on the compressor that possibly is starting to fail or someone may have adjusted the time band up on it. I myself would remove it and install a delay on break timer and a 5 minute setting would be ... Air Conditioners

Hi, We have two Paragon split systems which effectively cool our large home. One system is playing up. It started 3 days ago where there is water dripping from the front of the unit and the green 'run' light is now flashing. I tend to think it's blocked somewhere, buy my husband cannot find where to check this. Our outdoor units are both under the house with very effective ventilation but the last 3 days have been extremely humid, however the other system is running perfectly. Any ideas? Thanks,


More then likely the blockage is inside the a-coil section. At the drain. To get to it easier remove the pvc drain line. As the drain line comes out of the collection pan it goes into a pvc line the 90 degrees elbow goes to floor. So cut the lin ... Air Conditioners

LG AS-W2463 SERIES(LSZ 24) SPLIT INITIALLY THE SYSTEM SHUT DOWN DURING COOLING WITH AN ERROR MESSAGE 'C06'. iNVESTIGATED AND FOUND THE CONDENSOR FAN NOT RUNNING. CHECKED VOLTAGE TO FAN MOTOR - OK. REPLACED MOTOR, STILL NOT RUNNING. WITH PORTABLE EXTERNAL FAN BLOWING THROUGH CONDENSOR, COOLING NORMAL.


Check the simple things first, did you changed the run compasitor to the fan motor that should power up the fan ... Air Conditioners

Hi the outdoor unit turns on ( fan runs) the indoor unit does open, no heat or cold air blowing. In just fan mode the unit works fine etc speed setting ok. Its a sharp split type air model # ae-a244j outdoor,ay-a244j indoor unit what would be the problem, theres only two parts in the outside unit behind the side plate where the wires info is,small black box three wires and a round unit with wires. I hope this is help full cheers andrew


My gut says that this is evidence of a bad control board(circuit board). As usual, double check that your batteries are good in the thermostat. I have seen some weird things happen when the batteries are low. This one may be a job for your local con ... Sharp Air Conditioners

A/C shuts down and operation indicator and smart saver indicator flashing on samsung AQV30UWCN split system after heater runs normally for 5 mins. I reset the power and the units starts and runs normal for a short period of time and it all happens again. The AC system just had an electronic overhall as the fan blew up and took out all of the electrics. The problem never happened before the overhaul.


... Air Conditioners

A/C shuts down and operation indicator and smart saver indicator flashing on samsung AQV30UWCN split system after heater runs normally for 5 mins. I reset the power and the units starts and runs normal for a short period of time and it all happens again. The AC system just had an electronic overhall as the fan blew up and took out all of the electrics. The problem never happened before the overhaul.


... Samsung Air Conditioners

KELVINATOR KSR20C Our split systeme air con does not heat or cool the outside fan run when on but the inside fan doesnt run the little led on the circuit board on the outside unit is blinking on for 3 sec ond off for 3 sec do these air cons have a fault codes ??


One might think so, YES! look on one of the door panels that you can remove! Thank-you-very-much! ... GE Zoneline AZ38H12DAD Split System Air Conditioner

I have a split system sanyo heat pump model # kmh0922. The evap. fan will not come on when called for in fan mode. When i put it to heat the indoor fan will also not come on. The compressor runs but the reversing valve seems to stay in the cooling mode. When it is put into cooling the indoor fan goes off after 15 seconds and will not come back on. (The condenser fan and compressor seem to act normal in cooling.) Any ideas as to what the problem could be? Thank you, Mike


Sounds like the blowers capacitor has gone bad ... Sanyo Air Conditioners

I have a split system air conditioner. the inside fan turns on fine but the out door will not. i pushed the contactor in (located at the outdoor fan)that seems to turn on the fan. i measured the voltage with multimeter across the contact 24 volt side and got low voltage reading. then i disconnected the wires to the 24 volt side of the contactor and measured the wires, the wires read 24-27 volts. i dont know why when i connect it the readings are low. i even got a new contactor and still the same


Contactor working means fan might be bad can you feel any resistance from fan or bad capacitor. ... LG LSC091PMA Split System Air Conditioner

Hi there i have a toshiba single phase split system that keeps tripping the breaker after about a week of running i have checked the pressures the running current the fans an the coils an eveything is running well ive also checked the windings on the compan there fine any help on why it keeps doing this. cheers


Check and see if it is correct size breaker. The breaker may be weak. If your amp draw is ok and the units starts ok. You may have a loose connection on the breaker or a bad breaker they do get weak over time. On the outside unit there will the corre ... Ruud Central System Air Conditioner

Fan stops mid cycle but compressor continues to run on my lg split system. The unit then stops cooling. If you let it set for a few minutes it will reset and run for approx 5 minutes.


Check the fan capacitor, and with the power off to the unit, spin the fan blade to see if it spins freely, if it doesn't then the bearings in the motor are bad,it if does then it's probably the capacitor or if you have a fan switch in the system, t ... Air Conditioners

HAVE A SMH18SA-1 MINI SPLIT HP SYSTEM. WONDERING IF THE FAN SHOULD CONTINUE TO RUN AFTER THE DESIRED TEMP HAS BEEN SATISFIED ON COOLING. OF IF THE FAN SHOULD SHUT OFF WITH THE CONDENSR.


MOST WILL RUN FOR A SHORT TIME TO BLOW OUT ALL COOLING AND DRY COIL TO STOP MILDEW. ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0858 seconds