Having problems with your Air Conditioners ?

Our ac is not giving any cooling effect even after a long running time kindly suggest samsung AST18WJWDB


Answers :

You need to make sure that the unit is clean and all filters are clean. This includes the indoor coil and the outdoor coil. After cleaning, and still not cooling properly, check that the compressor is coming on. If not, check that the compressor is being told to come on by the thermostat by checking the voltage. If not, then its the control board to the unit. If so then check the leads on the compressor by doing an ohms test on each individual lead and a ground source. Ohms should read infinite. Then test between each lead. If you get a reading less than infinite, then the compressor is bad.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Our ac is not giving any cooling effect even after a long running time kindly suggest samsung AST18WJWDB


You need to make sure that the unit is clean and all filters are clean. This includes the indoor coil and the outdoor coil. After cleaning, and still not cooling properly, check that the compressor is coming on. If not, check that the compressor i ... Samsung Air Conditioners

Ruud Silhouette II furnace: comes on and runs for as long as it wants, then turns off. Sometimes turns off at pre-set temp, other times just when it wants. May turn on again, behave well for several cycles, or for 20 minutes. When I get too cold, I go out, downstairs, and thump it near the fan. Starts right up, runs for as long as it chooses. Nearly least energy-efficient kind, v. frustrating. Had trouble-shooter out a few years ago, couldn't find anything. An intermittent short?


Hi ruby. Begin by installing a new thermostat. Preferably one that allows you to program weekday and weekend temps. separately. Joe ... Ruud UBHC Air Conditioner

I have a 8 years old window ac. It's working quite ok. I just want to know which mode is safer low cool or high cool when humidity is high but temp. is about 32-34 degree celcius. Technican advised me to run in high cool mode for some time n then switch is off, but i want long hr. running in low cool mode which is quite comfortable. Kindly advise.


Its not a mater of safety. Its only a matter of witch is best for you. If you want to maintain the temp then leave it on low temp. If you want to save money then you can switch it to power saver mode on high to bring the temp down. Hope this helps. G ... Air Conditioners

Capacitor problems!! Samsung silver nano ( health)- Capacity-18000BTU/hr - Model-AST18WJWDB - Voltage-AC-200-220v/50Hz--Power input-1850W Since the last two years, I had a problems with my air conditioner constantly after 2-3 months. The repair experts suggest to put a new capacitor everytime I let them investigate it. So, I already bought 4 times!! and they will charge me Rs 2000- Rs 3500 /- for labour charge and new capacitor. I don't trust them anymore. I want to buy a new capacitor of good q


It's not the cap's fault that i see as the real problem,the cap is used to start the compressor and is rated for so many starts per hour and if you go over this rating it will stress the cap and after some time it will fail and this problem is known ... Ruud Matching Split Air Conditioner

I have LG split aircon outdoor unit A4UQ266FAQ with indoor unit 1x AMNC12GD4LO & 2X AMNC09GD4LO. It can't run for long time, always shutdown by itself after a while, give error indicator 4 x green light blinking at power status & 2x red light blinking at


... LG Air Conditioners

ComfortAire window AC on the touch pad there are times when no controls work and the temperture flashes from 30 to 86, the fans runs and the compressor kicks on runs for a short period of time then kicks off. Does not run long enough to cool the room. Anybody know what is wrong with this AC just bought this Comfortaire July 9th 2010 ran good for one day and one night the started to act up please help.


... Comfort-Aire CS-101A Air Conditioner

I have a Lennox model CB19-51-1P air handling unit with HP19-511-1P compressor heat pump unit. I just turned the heat on for the first time this season. And I am getting low heat volume. The heat pump unit is running for long periods. I am getting enough heat to maintain the 70 degrees setting with constant cycles, shutting off for short periods, running long periods. When the thermostat is turned to a cooler temperature, the unit shuts off as it should. Could you please help trouble shoot po


First thing you need to check is if the reversing valve is working you maybe running your A/C with the heat strips on depends on the t-stat your using some heat pumps will bring the strips on with a high d ... Air Conditioners

Have a 5ton straight cool ac system. It's a Payne puron split sytem. metering device,txv. It will run for about 5 miutes during that time u can feel some cool back on the suction line. after that run time it will start to make a hissing noise. Over amp and shut off on internal overload. Any suggestions? Complete system is brand new and was put in around November.


Brand new systems won't require cleaning. Debris could get trapped inside the internal parts/lineset and break loose and cause a blockage which could cause high head pressure, hissing and over amp. It is possible that the charge requires readjustment ... Air Conditioners

My 338-27 taylor ice cream machine problem I am having every time I make a ice cream for a customer the machine (compressor comes in ) for 5 min each time. I am in the field i also own an A/C business haven't done much refrigeration since the early 90s I converted this machine from r 502 to 408 a runs great however runs too long any ideas


... Air Conditioners

A) I am trying to obtain a manual for a model #HWR12XC6-RB air conditioner. Can you send me one via email? B) Although it seem to run, the compressor only seems to run for a minute or two before shutting down for a time. Then it restarts. The temperature display seems to decrease while the compressor is running, and rises again when it is not running. The temperature never seems to aproach the set temperature. C) There are two types of noise I wasn't expecting. One seems to be a kind of klunking


... Haier HWR12XCB Air conditioner

Blower runs slowly if at all. Give it a spin or two by hand and it will slowly build up to full speed, RUN AND COOL AS NORMAL. But it only runs for a short time (12 to 15 minutes) then the blower slows down gradually then stops.


The fan bearings have become gummed up and will need to be replaced or cleaned. I am assuming yours is not a split type. If so you will need to remove the whole unit from its casing. Have a look at this link : http://dl.owneriq.net/2/2dca85dd-1 ... Fedders Air Conditioners

Have a vokera syntensis 35, keeps cutting out and red light flashes. When turn to reset starts up again and usually runs for a long period of time as normal, however tonight continues to cut out twice in 1.5hrs. Bar pressure sits just above 1 when system running and doesnt appear to be dropping when system cuts out. Help anyone got any ideas? The boiler is running a large system of approximately 18 rads.


... Air Conditioners

Amana AC model MBR2000, installed mid May 2009. When outside temp gets above a certain level the AC does not cool. fan keeps running and it keeps trying but not work. When outside air gets cooler then starts to work again. Tech here twice. 1st time when AC was working - could not find problem, 2nd time when problem was occurring. 2nd time found burnt wire and replaced. Same problem started again 2 days later. AC unit is large enough for our house, is 18 Seer 2 stage. Any suggestions as to proble


Hi it sounds to me like what actvates the 2nd stage of the compressor is not turning the compressor on when the ambeint temiture reaches the point that it calls for the 2nd stage to start it may be an out door thermostat or a ambient senser and I wou ... Air Conditioners

I also have a grunaire dual zone mini-split that doesn't work worth a ****. I've had it looked at multiple times and had freon r410a added twice and still nothing. Without the high side - how do you know if you put too much or not enough. I also have a long run on one system being over 25ft from the compressor so its a longer run - but that one at least worked for a moment - the short run - never worked. Get the FC fault consistently on one unit - other unit just doen't blow cool - how do yo


An FC fault on a Grunaire is typically a defective PFC board in the outdoor unit or a Grossly overcharged system, where the drive cannot overcome the standing pressure to start the system up...the ONLY CORRECT way to charge one of these u ... Air Conditioners

I have a 18000btu LG mini split heat pump installed about 1 year ago in vacation home. In heat mode the unit cycles on and off when room temp is within 2-3 degrees of set point. Cycle on time varies between 35 to 60 seconds (sometimes more). The off time is 2-3 minutes. During this time, I check inside temp with accurate digital themometer mounted at the air intake of the unit and the temp does not change, assume because unit does not run long enough. When I put temp set point more than 3 d


Hello.I think they are on to something with shortcycling on temp sensor.I think it should be sampling the return air instead of (inside coils ?).A 2*f dead band use to be built in (factory installed) to thermostats to prevent on/off, but ... LG LS-L1210CL Mini Split Air Conditioner

My unit has never worked properly as it is dripping water and ruining my wall and my filters. The business that installed my unit is giving me the run around and ignoring my requests to fix my unit once and for all. They have been to my house multiple times with different "solutions" to this problem. The last time I was able to get anyone on the phone from Air Masters, the owner told me that he would replace my unit with a new one, but that you guys would not stand behind your product. Now,


It's short of gas. That's why it's forming ice over the coil and cutoff by coil sensor and then blower only would run. At that time ice become starts defrosting resulting to this water drop. Call repairman to find the return pressure by gauge. 60psi ... Goodman Air Conditioners

My son gave me his portable air conditioner but did not give me the instruction book. not sure on the safety features nor how to run. it is a conviar portable refridgerated air con. model KY-32/Xc (co2) 002118 as my son is out of reach at the moment and I need to run this unit, I would be please if you caould get back to me asap. or let me know of a site to get a manual. thanking you for your time. R.Casey.


SERVICEMANUALS @ COST\012www.mauritron.com\012Manuals at free download: ... Convair Air Conditioners

My thermostat had a blinking low battery symbol in the top left corner of the led screen and the furnce would not stay running as a result. I have changed the batteries and the furnace cut in but will only run for so long before it shuts off and the sign on the screen says heat on but the furnace is not cutting in and the temperature is way below the set temperature for the house. If I keep taking the panel off the wall and reconecting it as if i changed the batteries every time, then the furn


Your thermostat sensor is getting week. Please change your thermostat. ... Honeywell Air Conditioners

My central ac system occasionally runs too long and the temperature gets way too cold. The digital thermostat reads that the temperature is too high so the ac still runs. This doesn't happen all the time but last night we had the thermostat set on 74 and when my wife got up during the night it was 67 degrees in the house (another thermometer read 67, the thermostat read 78)


I have seen this is many digital thermostats. The worst problems usually come from the touchscreen thermostats. I would suggest installing a new thermostat. Make sure that you read the instructions before you even remove the old one. ... Air Conditioners

My air stops running inside before it get to the temp. Its set for but the outside unit keeps running and after a minute or two the air will start blowing inside again but the outside unit never turns off until it gets to the desired temp but because it stops and starts so often inside it takes a long time for it to reach the desired temp. Inside


You have a possible thermal overload problem in your furnace blower motor dirt will cause this problem when it doesnt allow air across the windings of the blower motor if not dirt the motors going bad and getting hot use a shop vac and eliminate dirt ... Goodman CKL36AR36 Air Conditioner

AC will run for several hrs, cooling then just shut off. You can restart it & it may run but not long. I wonder if it has a float switch that is cutting it off. This is a new unit. First time used. I was told to make sure the camper was level.


Camper level should have nothing to do with it. When it shuts off, can you run it in fan only mode? Pull filter down from ceiling assy.,when this happens and let me know if you see frost on the coils up in that part of the AC. Get back to me. ... Dometic Rooftop RV Air Conditioner

I have a Breezair evaporative cooling system. The other day it was running for a long time at full fan and then a smell of burning came from all of the vents. It was 39C outside. Turned it off immediately. Tried it again next day and working fine but I did not run it at full fan speed. what caused this burnin smell? and is it safe to use.


Millerba says it is "probably" safe to use. Will he pay up if he is wrong and your house burns down with you in it? Yes 39 degrees is hot!!It IS economical to replace the motor provided the general condition of the unit is OK. Call a REAL exper ... Air Conditioners

Have a Dometic Penguin on the front of a 5th wheel with mech. controls but compressor only runs for a short time & takes a long time to start again new unit


It sounds like your compressor is overheating and going out on internal overload. It takes awhile for the compressor to cool back down before the overload resets itself and allows the compressor to attempt to restart. This could be a refrigerant prob ... Dometic Rooftop RV Air Conditioner

I installed my attic fan about 10 years ago. Now, it will not start without me giving the blades a push. It hadn't been lubricated since installation. So I applied some 3-in-one oil. Still wouldn't start on it's own. Then I tried some WD-40 and it would start better. But then, not running overnight, again it wouldn't start without giving the blades a spin. Any suggestions?


Hi,\012The capacitor has gone bad... that is what gives the motor the "kick" to get it started...\012replce that and you are good again..\012\012heatman101 ... Air Conditioners

Hi!! I got this compressorfit just 6 months ago & would have not got it run even 50 hours run. As per the workshop, It has leakage & can't hold the gas now. Kindly suggest if there is a way out to get it repaired/replaced as i can'tafford to get again a new compressor put. Regards Shantanu


The system need to be charged with nitrogen to determine where the leak is\015\012then repair the leak and recharge ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific