Goodman gas pack,stopped working,replaced batterys in thermo,board looks good.can reset temp,switch,will run 5 minutes or so.could jets cause flame to wander? not serviced in 2 years,board,temp,switch and gas valve and exhaust motor all 2 years old.


Answers :

What switch are you resetting? If it's a limit or roll out then first check for proper air flow (filter, A/C coil) to see if it's overheating. Then watch the burner flames. When the blower comes on do they change shape, color or waiver? If so you may have a cracked heat exchanger.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Goodman gas pack,stopped working,replaced batterys in thermo,board looks good.can reset temp,switch,will run 5 minutes or so.could jets cause flame to wander? not serviced in 2 years,board,temp,switch and gas valve and exhaust motor all 2 years old.


What switch are you resetting? If it's a limit or roll out then first check for proper air flow (filter, A/C coil) to see if it's overheating. Then watch the burner flames. When the blower comes on do they change shape, color or waiver? If so you may ... Goodman Air Conditioners

I am looking to buy a house in forclosure. It has a Tappan gas furnace about 9 years old and there is no manual. Can you advise as to whether the following problem is serious and estimate what the cost of repair will be? Exhaust blower is always on; red light on circuit panel is constant. Then gas flame is ignited and burns for a couple of seconds; yellow light on circuit panel comes on. When blower motor begins, gas flame goes out, yellow light goes out, and red light repeats sequence of 2


HelloSounds like the flame sensor is bad.Or possible photo eye.Worst case would be a new circut board.Anywhere from $100.00 to $300.00 depending.Legally a home you purchase has to have a heater that works and a hot water ... Air Conditioners

Heater: Rheem Classic 90 Model RGRJ In service since 7/02 Problem: Thermostat calls for heat Steady Green Light Inducer motor starts and runs lighter comes on and glows no gas, no flame Voltage across gas valve is zero no yellow light lighter goes out inducer motor quits blower is off no heat Troubleshooting activities: Resetting (power off then on) will bring on the flame 99% of the time checked for exhaust clogs, none found no evidence of water at inducer fan housing barb have


Failed control board. Replace circuit board. ... Air Conditioners

Ive got a DESA vented gas fireplace heater Model CD36RN in which I loose the flame after a few minutes of operation. I would re-lite the pilot , turn the gas valve back to the ON position, the flame will come on once again and will go out after a few minutes to an hour. Also Humidity somtimes appears on the glass inside the fireplace. It's about 3-5 years old and Id appreciate any advice. Thanks Bob


... Desa International Wall/Window Air Conditioner

I have a 15 ton carrier gas pack at work with inducer motor and spark igniter with hall senser ..showed error 6 flashes on igc board which the drawing said was inducer motor or hall senser problem..replaced both..they were old and rusty..error still there..inducer runs for 1 to 2 minutes..times out starts over again..no ignition..cannot here gas valve solonoid/coil click..checked igniter and flame senser cleaned..but they looked great ..no cracks anywhere..replaced heat exchanger 2 years ago..pr


... Carrier Air Conditioners

A 2 month old Goodman GMH95 natural gas furnace has been working properly until tonight. Now it starts up properly, but after 30 seconds (and right when the cirulator fan kicks on) it shuts the gas valve stopping the flame. LED light flashes 8 times, which is not an option on the trouble shooting guide. Unit will retry every few minutes and cycles this way over and over. It appears the control module is not receiving the gas flame detection signal. What do we need to do?


Goodman's control boards are very sensitive as well as the connections to the gas valves. Check the wires and make sure they are snug and tight. With it being only 2 months old, I doubt the board is bad or the flame sensor(unless it is a used syste ... Air Conditioners

I'm loosing the pilot & Burner flame after 5-7 minutes when I start the heater gas unit, the burner is working fine & controled by the thermostat, I' think the problem of loosing the pilot & burner flames after 5- 7 minutes is because some problem in the thermostat or the Solinoid gas valve, and I dont have the service manual of this type PW50-3 Hunter Natural Gas Heater, I' need your help


Faulty thermo couple replace it you can thank me later, do you have a carbon monoxide detector? ... Air Conditioners

Rheem Power Vent gas water heater (only 2 years old) had electronic thermostat/gas valve fail. Received warranty replacement today but I can't get the old assembly out. I cannot get it to budge even using 1 foot pipe wrench and tapping on the end with a sledge. Hesitant to put much more torque as I am afraid of damaging the tank. This is natural gas heater so uses right-hand threads (so I am trying to turn counterclockwise). Threads are too far inside the tank wall - can't reach them with p


Hello Try a "breaker bar" on the end of the pipe wrench.Good news is that the control threads are BRASS and the tank is steel,meaning the control will always come out (without spray oil).Counter clockwise is correct.Have faith and lay into it! ... Air Conditioners

I have a 2 year old Goodman GDS80703ANA furnace that has always had a problem starting. Sometimes it starts on the first attempt but other times it takes 2 or 3 attempts. This is what I see happening: The Induced Draft Blower starts and runs- the Igniter will glow for a few seconds and just as the igniter starts to stop glowing I hear the Gas Valve click and open but it is too late. On the next attempt or so, the Gas Valve will open sooner and burner will ignite. My question is: Is the Integrate


The board controls the timing ... Air Conditioners

I have carrier infinity 18 central air and worked good for one year and second year summer season its out of purion gas and we had an authorized person to recharge with purion gas and worked for a few days and back to old problem and now found the condensor is leaking and condensor pan is cracked and found out service personnel says there are many carrier infinity with these problems. I have been fooled by inferior carrier product and would like to form a group with people with similar problem


Carrier carries a 5 yr parts warranty.I'm not a big Carrier guy but the are not an inferior product from what I've seen.I'd contact another company that is a Carrier dealer for a second opinion. ... Carrier Air Conditioners

I have a 10-year old Carrier Gas pack Model #48GS024060301. Turned on the heat for the first time this season and the unit did not turn on. I was able to turn on the house circulation fan and since it was a warm day today I also tested the A/C side and it worked fine. The inductor motor and fan were replaced last year. All the fins on the fan blade basically flew off on the first start up attempt last year. The entire unit, heating and A/C, were serviced within the last year by a certified p


If the induction motor ain't going I would look for a blown 3 amp (purple) fuse on the control board. If that was good I would check if any of the roll out switches were tripped. If a rollout switch was tripped check or air restrictions somewhere. ... Air Conditioners

I have a Goodman Furnace model#GDS80703AXBC.The unit is one year old and ran fine until the gas got shut off accidently outside at the meter.Unit was cycling with no gas for 2 days.we turned the gas back on and the unit is showing one light blinking for over cycle trys.The unit did eventually start up but it does not fire up after each time the thermostat is calling for heat.The unit has been running like this for about 10 days now.I have replaced the Diagnostic computer, glow igniter,flame sens


The only part not replaced so far is the gas valve. Because the gas valve is getting power does not mean it is opening.You could also have gotten trash(corrosion/scale) in the valve orifice and or the burner orifices.Is there a drip ... Goodman Air Conditioners

I bought a forclosesure this summer and not all that familar with the furnace in the guest house. I'm use to having a furnace with a pilot light(yes, it was 34 years old)now I,m trying to get a goodman furnace going. I know it was sitting around for atleast 2 years. The home inspector said everything works.The model number is gmnt040-03. The gas is turn on the outside line. When I start it she begins to hum and then the ignition light goes on. then a blowing noise but then I get no flames-after


Hi,A few things to check...Is the gas line valve on at the unit....follow the gas line back a bit sometimes the gas valve can be out of view.Also check the gas valve in the furnace... it may also be in the "off" position.... ... Air Conditioners

Rheem Criterion II gas furnace, model RGLH, 8 - 10 years old. Came back from vacation and furnace won't fire up. Went through start-up procedure. Brand new digital thermostat, maybe one month old, been working perfectly, replaced batteries in in anyway to no avail. On motherboard, two green lights (LEDs) comes on, but 'flame' LED (orange) won't come on.


... Air Conditioners

When main gas valve opens to start burners the gas pauses then ignites with a high volume woof.The pilot flame looks a little small could this be the issue. This unit is Brivis Buffalo year 1988 model UR800A


The problem is called "Delayed Ignition". This can be caused by burner & pilot obstructions (dust, lint and/or pet hair) and needs to be thoroughly cleaned. At 23 years old, I'm surprised the unit is still in service.Hope this helped ... Air Conditioners

Flame on old mac 1155 keeps burning out took bottom panel off gas valve to allow o2 in flames stay on whays problem


... Intertherm Air Conditioners

Old gas furnace (50+ years) just had gas valve, thermo pile and pilot replaced. Pilot now fine, but there is a rushing or sucking sound when trying to ignite fully, lasting for several minutes. Is this caused by too much or too little air? I see a ring which turns to adjust the air intake.


... Air Conditioners

Just bought a home that was not occupied for 2 years. Don't know how long the furnace had not been run. It is a Comfortmaker that is only 5 years old. The Honeywell valve is indicating all is good ( green light flashing "heartbeat" ) the system will not activate. Ventilation fan will not come on, igniters don't glow red etc. - there is 110V and 24V throughout the system. I just had a service man looking at it for quite a few hours over a 2 day period. He gave up and walked away saying what am I


... Air Conditioners

My Carrier gas furnace (ser. 1903A41848) located in the attic, is five years old and suddenly won't light. IT cycles the fan when I cycle the power to the unit and seemingly attempts to ignite through 3 auto-attempts, (I can smell the gas), yet no continuous operation with heat occurs afterwards. Two lights exist on the exhaust vent both begin green yet one turns red after the ignition attempt. Please let me know your thoughts. -Doug


The igniters bad or if unit ignites the flame sensor is bad try this first ... Air Conditioners

I have a Dyna-Glo RMC-50LPT propane heater that is about 5 years old and I can't get rid of the yellow flames when it operates. I have tried: - removing the heater and blowing everything out with a compressor - blowing the copper gas line out with a compressor - replacing the regulator that is attached to the propane tank The tank is a 100lb tank that was filled in the fall and the heater has barely been run at all. The pilot seems to work fine with a mostly blue flame (only the very tip is


Also looking for a manual and parts list.....who manufactures these heaters? mine is a rmc 50lpt and have not found a manual and/or parts list......... ... Air Conditioners

We have a residential Lochinvar Solution Boiler (model RBN090). Around 7 years old. For past 2 weeks pilot light keeps going out. 2 repairmen have come out. We have replaced the Gas regulator, the roll out switch, the thermocouple, and the pilot flame on the thermocouple. Pilot light continues to go out. No one has anwser. Pilot flame goes out sometimes when system is cold, other times after working for several hours and hot. Very random. But we have to relight serveral times per day a


... Air Conditioners

I have a Honeywell spark igniter system with gas valve VR8304M3558. The valve is extremely noisy when activating (can hear it on the second floor!). Only 1 year old, been that way since new. Is this GSV8304M4507 a newer design replacement and is it quiet?


... Air Conditioners

Hi i hope youcan help me, i am trying to locate a gas valve for a fagor 15/20 combination bolier. The boiler is about 8 years old and is fitted in my caravan. Please can you help. Regards Jamie


I would bring the valve to your local appliance parts store. Likely they will be able to match it with a universal or after market valve. Make sure you write down the model and serial number of the boiler and bring it with you. ... Air Conditioners

I have a rheem prestige series contour comfort control natural gas furnace. At the end of the heat cycle the unit will shut off, then the blower kicks on to cool off the heat exchanger. It will actually kick up on high fan speed to exhaust the heat. The unit is only 3 years old and it did not do this before.


Make sure that your furnace filters are clean it sounds like it could be cycleing on high limit. ... Air Conditioners

Have 3yr old potterton statesman 50/70 oil boiler,is smoking badly(black).boiler service & cleaned,burner checked,new nozzle and pump assembly fitted,oil lines clear and bled,pump pressure reset.flue gas temperature v.high. flame vivid yellow very ragged,mixture is obviously very rich but no adjustment to air damper seems to work for long. any ideas very welcome.