Frost build-up we keep getting build-up at the back of the unit; it has been getting worse from days to hours to see any frost starting. any ideas?


Answers :

Either the unit has developed a small refrigerant leak or the unit needs a good cleaning. It sounds like the unit is a portable type unit. I would remove the unit and do an extensive cleaning and then retry the unit. If it continues, it's time to replace it. Trying to find a leak is more costly than replacing it. They are usually not easy to find.
Two things will cause this: low air flow or low refrigerant. If you are in cooling mode then check your filter and indoor air flow. If that's good then you'll have to get a technician to check your refrigerant. If it's low it has a leak that needs to be fixed.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Frost build-up we keep getting build-up at the back of the unit; it has been getting worse from days to hours to see any frost starting. any ideas?


Either the unit has developed a small refrigerant leak or the unit needs a good cleaning. It sounds like the unit is a portable type unit. I would remove the unit and do an extensive cleaning and then retry the unit. If it continues, it's time to ... Air Conditioners

A/C does not blow cold air. It has frosting built on the pipe that connects to the a/c unit outside. There is some water built up where the filter sits. I turnd off the a/c for a full day, the frost melted, filter is very clean, and nothing on the inside seems abnormal. I started the a/c again after 1-day but the frost started to built up again and no cold air was blowing. (it blew cold for a few minutes only). I don't know what the problem can be. Please let me know if you have any ideas to mak


Shelly,\015\012Most likely you are low on freon. Your air conditioner uses a coil that gets cold when the freon passes through it to produce your cooling. The temperature of the freon inside the coil is directly controlled by the pressure of ... Air Conditioners

Had "So Called" RV repairman work on Coleman 13.5 Roof AC! He said he fxed it first by lubrication then he replaced the "Hardsart" and told me if the fand stopped again to spin it to get it started and said I should just replace the AC. Another Mechanic PooPooed that Idea and ended up removing the "Hardstart" and wiring direct from the Diod! The sytem worked perfectly for a couple of days then the fan shut down again! Leter on I tried it again and after a "Clank" she started again and we turned


If the fan is not turning, but just humming, you need to replace the capacitor. If you were to spin the fan by hand (carefully) when it's doing this, it will speed up and run, until next time. The "hardstart" they refer to is for the compressor and i ... Coleman Mach III Air Conditioner

Fujitsu 18000 goes into defrost once an hour at 28to 32 degrees outside temp. trying to maintain 70 degrees inside . test run was ok on start up. just installed 3 days ago .. vacuum out the lines. lost no 410a. it has be very frosty around here the last few day.. when its not frosting up puts out lots of heat.


What is the lowest outside temp manufacturer suggests? Heat pumps are not very good when it gets good and cold... call the installers and see what they have to say for you. ... GE Quiet-Aire Ductless Heat Pump Split System AS1RD09AA0/AS0RD09AA0

My LWHD8000R LG windows unit just started spitting water. It's been operating just fine for quite awhile. I checked the drain pipe area and cannot see any clogging where the pipe attaches (though I have no pipe attached). I opened it up and cleaned it up as well as I could, but it will not stop. It starts building up water again spitting after running for about 15 minutes. It is tilted properly in the window. Any ideas? Can I make some sort of makeshift drain pipe for it?


Thanks for your question!\015\012I'm sorry that you haven't received an answer yet.\015\012The response rate on FixYa FREE questions is usually over 80%, but sometimes questions go un-answered when:1. the question is unclear, incomp ... LG LWHD1800R Wall/Window Air Conditioner

I have the Mitsubishi split unit system with 24BTU for my bedroom, the problems starts after the compressor has started and the cold air has been blown through the indoor unit, this pleasure lasts for about 2 mins and then a strange sound from the outdoor unit , sounds like the power is getting low or some what, then it shuts itself down. A technician checked and said the compressor needs replacement..its 12 month old and works 6 hours a day!!!


Ok, it can be two things. \015\012\015\012The outside unit needs to be washed with a water hose to rinse any dirt and debris that can cause a restriction in airflow over the outdoor coils. If they are allowed ... Mitsubishi MSM18NW Air Conditioner

Outside unit is running however it is not cooling.I cut off the circuit breaker wait 20 or so minutes and turn it back on and the unit works perfect for a while (no set amount of time ranges from hours to days) any ideas?It is a new unit and did the same thing when it was turned on for the first time.Worked 2 weeks before starting again.Unit is a little low on freon.It is a Goodman 3.5 ton ac only(gas furnace)


Sounds like there is a Freon leak and has been since it was installed and is going off on because of low charge, you will need to call a competent A/C repairer, more then likely the leak will be in the air handler, should cost under a $100 to fix. Go ... Goodman CKL42AR42 Air Conditioner

This is about a 15 YEAR OLD Trane XE1000 30,000 BTU A/C unit. The A/C was not working, but right after I called to have someone come fix it, it started working again all by itself. When the unit was not working (for about 18 hours). The house got up to about 80 degrees with the thermostat set on 70. When the HVAC tech got here (next day), he told me the compressor is shot because the thermal limit switch inside the compressor is overheating. The area where the thermal switch is getting warm, but


You can wait just buy a capaciter start system theat will override the old start capaciter, this is a common problem for all ac systems. just bu the ac start replacement and yo should be good to go for a couple more years. and if you want a reference ... Air Conditioners

I am curious if anyone know how to help me troubleshoot the A/C in my Van? It is a Plymouth Voyager 1994 Generation II model. I filled it with r134a & no luck getting any cold air to blow. Any ideas where to start looking for the problem? It's hot...and I don't want to be stuck driving 12 hours in my van with no A/C.


Your van requires r12 no longer available, If your Plymouth Voyager is blowing hot air when the air conditioner ... Air Conditioners

Power failure and when came back on the green light is flashing and wont start we are in Katherine NT and power went off for about two hours, the air con was on at the time, the model is a FTKD718VMA, it has a remote, and as far as I can see the timer is not on. It responds to change of temp and all the other functions but will not get past the flashing green light.


Go to their website and there are service manuals that tell what is wrong using different displays on remote I tried to paste it here but it didn't work ... Cfm Daikin R410a Split System Air Conditioner

Goldstar r0501m I have a GoldStar R0501M Air Conditioner mounted in a window. The issue that I'm having is after a few days of (non-continuous) use, enough water builds up inside the machine that the fan starts audibly splashing through it. I cannot see any sort of drainage hole on the outward-facing half of the machine, and have been resorting to tilting the whole air conditioner to drain the water through the power cable hole. How is it meant to be drained?


... Air Conditioners

I turn the thermostat down at night. When I get up in the morning I turn it back up. The heat kicks on for a minute or two then the unit starts blowing colder air. If I turn the thermostat to the OFF position, wait until I hear all blowers stop, then turn it back to the ON position, it will start blowing HOT air again. Some times I have to perform this cycle 3 times to get it to keep blowing hot air. Any ideas as to what is shutting the furnace off? Thanks, Wayne


Theremostat switch problem. Replace it. ... Air Conditioners

Amana AC model MBR2000, installed mid May 2009. When outside temp gets above a certain level the AC does not cool. fan keeps running and it keeps trying but not work. When outside air gets cooler then starts to work again. Tech here twice. 1st time when AC was working - could not find problem, 2nd time when problem was occurring. 2nd time found burnt wire and replaced. Same problem started again 2 days later. AC unit is large enough for our house, is 18 Seer 2 stage. Any suggestions as to proble


Hi it sounds to me like what actvates the 2nd stage of the compressor is not turning the compressor on when the ambeint temiture reaches the point that it calls for the 2nd stage to start it may be an out door thermostat or a ambient senser and I wou ... Air Conditioners

I have a Admiral AW-06CR1FM room air conditioner. Since last night, the LED panel on the unit displays "EE" and I can't get the unit to start. There is power in the circuit. Was able to get the unit started and running for about three hours last night, but it stopped and EE was displayed. Now, I can do is press the re-set on the power sbcle, but that just produces the EE, and nothing else happens.


Hello. The EE error indicates that the time delay board {TDB} is faulty. IF you are technically inclined you can go inside of your unit and by pass the time delay board. This is the quick fix and for the most part you will won't miss it anyway. O ... Air Conditioners

I have old rheem ruud hot water tank. it's down for 4 day's, i would like to get it started, but the thing i would like to find out is can i get it going by lighting it up by using lighter or not. The hot water tank Mod. RR40-38M and the Ser # 1297J32709. Please help me i hade been without hot water for 4 day's. Thank you.


Yes you can light it with a BBQ type lighter (long enough).If it lights and stays lit then you need to change the thermocouple (looks like a little pipe off gas valve)In simplest terms, a thermocouple is a temperature sensor. Normal ... Air Conditioners

My 6 year old Heat pump RHE 60 on days when temp. gets up to 85F the Compressor struggles to come on some times up to 10-15 minutes.A hard start kit was installed when unit was 5 months old for similar problem but later they (service people) found it was caused by a burnt wire. I dont know if they left the hard-start kit on unit or removed it. I cant get installing dealer to find me a fix for this problem .


Hi,One of the methods to curb if the compressor is not working is " Installing Start Kit".There might be many reasons.Let me write main reasons :-\015\012\015\012\015\012Compressor will not start some or m ... Air Conditioners

When i turn on my stadt ducted heater it take hours to turn on. i have to keep turning the unit on and off to get it to start. Sometimes it will start and turn off in a minute or so. If i get it going and do not switch it off it will work fine. Is there a way to fix this??this


... Air Conditioners

OUT SIDE UNIT SHUT DOWN IN HEAT MODE, WHEN YOU FIRST TURN IT ON IT RUNNS FOR ABOUT 30 SECONDS THEN BOTH THE COMPRESSOR AND FAN SHUT OFF FOR APROX 3 MINUTES {LARGE LINE STARTS TO GET WARM} AFTER 3 MINUTES BOTH START BACK UP BUT ON RUNN FOR 5 OR SO SECONDS THEN KICK OFF AGAIN, SERVICE TECH. BLED PRESURE VALVE WORK FOR LESS THAN A DAY, HE CAME BACK AND BLED IT AGAIN WORKED FOR LESS THAN A DAY,


Hi, You have a heat-pump, this I do no. The reason it is shutting down from how you have explained it to me, is the compressor is shutting down due to high pressure and it is going off on the internal overload. When the compressor cools down, it star ... Air Conditioners

One of the goodman condensing unit for my house starts good every thing works fine, but it runs OK for couple of hours and by then the refrigerant line connecting the unit condenses and it will not blow cool air. I have to turn it off, may be for couple of hours and start again and it works Ok till the copper line gets condensed and problem repeats.


The refrigerant line is actually supposed to condensate, but if you mean "freeze up", thats a problem. The condensation occurs because the line temp is lower than the outside temp, kinda like a soda can outside. From what you described, Im pretty sur ... Goodman CKL60AR60 Air Conditioner

The fan on outdoor unit sometimes starts normally, sometimes starts slowly and will get up to speed with a push or sometimes will not start at all. Loud hum when slow or stopped. Cools normally when it will start. Have replace capacitor. Any ideas?


SOME MODELS HAVE A TEMPERATURE DEVICE THAT CONTROLS THE FAN WHEN REAL HOT IT WILL CONTROL THE SPEED OF THE FAN WHEN COOL OUT THE FAN WILL VERY FROM FAST TO SLOW DEPANDS ON THE HEAT BEING PUT OUT BY THE OUT SIDE UNIT IF THIS PROBLEM OCCURES DURING BOT ... Air Conditioners

I have a kenmore central air unit model KAC024AK5. Fan started making noise few days ago. I'm still getting cold air. Opened the top grill and the fan is not loose. Could it be the motor and more specifically the bearing? If this is the case, should i get the motor repaired or get a new one from Kenmore Parts Canada? Your advise is greatly appreciated. gene


\012Hi,Yes, the bearing go bad and for the price of the new motor I would get it new... to repair will be more then half that if they can ...Here is a tip about troubleshooting your air conditioner...There ... Kenmore Air Conditioners

Hello, I have a carrier 58sta in the townhouse were renting. A few days after moving in the furnace was getting louder and louder each time we run the ac. It now sounds like a jet engine when it starts and stops. Also the thermostat will say its 80 and it feel like its 60 and it will continuously run all day. Other days it will feel like its 80 degrees inside and the thermostat will say 60 and it won't cool the place off. I replaced the air filter several times. I know the previous tenant before


The electrician might be able to help somewhat but an hvac tech is the person to call. It sounds like you have multiple issues if the thermostat is acting up that bad replace it!! but that wont stop the noise from the furnace thats either the blower ... Carrier Air Conditioners

Replacement fan I'm trying tov locate a replacement upper fan for this portable ubit. I called my local rep who directed me to the Fedders main location. I called and the recording says to check online, I can get an exploded parts list and can order from there. I do not see any thing like that. I sent 2 different email messages and have gotten an acknowledgement email but no more than that. HOW hard could it be to get a replacement part? Anybody have any ideas on how to get a replacement motor f


Please check the of fan , no of blades and direction of flow & also if possible pic of fan . it can be easily avl in open mkt. \015\012ravi ... Fedders A6P09S2A Air Conditioner

The fan on the condensing unit isnt working it works for awhile and then shuts off,then the compressor starts to work by itself really hard and the whole condenser heats up really fast so I turn off the breaker and start it again but the fan makes and electric humm and I have to push start the blades to get it to spin and then it will work for awhile and then the fan will stop again after about an hour and then same thing happens


Does the fan turn freely or is it hard to turn by hand? If it is hard to turn the fan motor may need to be replaced. If it isn't hard to turn then check the fan capacitor. You can test it with a multimeter or take it to a heating and air supply and g ... Goodman CLT36AER36 Air Conditioner

Flame roll out protection device just started tripping a couple of days ago. Can be reset and unit runs for 10-12 hours and device trips again. 14 year old furnace and this just started happening. Anything i can do until the repair technician comes?


No, heat exchanger is most likely cracked. Time for a new furnace. I cannot see your reply due to some tech issue w/ the site, so it may be a day or so before I can reply again. Please leave feedback for me if appropriate. Thanks ... Amana Air Conditioners