Outdoor unit does not Run

\015 The outdoor unit has proper line voltage, I have it in the cooling mode during test and have control voltage for R,Y,O. But still does not run. No signal going to contactor is leaving board. Now the LED light on the board flashes 3 times and stops for about 3 seconds and the flashes 3 times again. I checked the low and high pressure leads and they show closed through continuity test. My idea is the board has a faulty relay and needs to be replaced. Just want a second opinion before I do so. Thanks\015\012Todd\015

Answers :

If you manually push in the contactor does the compressor start? If so, then it probably is the defrost board. If not, then do an ohms check on the compressor to make sure it hasn't failed.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have the MR36TQY3f outdoor unit with 2 MW09Y3FM units and 1 MW12Y3FM indoor units! The MW12.. works great and one of the MW9... works great! When I run the 2nd MW9 only (other MW9 & MW12 off)..... the outdoor unit compressor or fan does not come on! If I run all units then ... compressor kicks on runs great, fan runs... lines get cold on the 2 good units ... nothing on 3rd unit... then I turn 2 good units off....and it sounds like the compressor kicks off and the fan will continue to run reall


After looking at the manual for the units, I believe that the system is having trouble with the number of units that you have linked. Here is a portion of the manual about multi system operation>Also link to manual:http://www.fri ... Friedrich MR36TQY3F Split System Air Conditioner

I have carrier split unit the problem is the when switch it on indoor unit runs but when outdoor unit runs it make cool just for 5 mins and all unit indoor and outdoor go shutdown and green light start blinking and after 5 mins unit starts again after 5 mins again shutdown . any sugges please.


... Carrier 38CKC036 Air Conditioner

I have a Trane XE 1100 outdoor unit. I had to refill the freon gas 3-4 times in 3 years. The technician mentioned that I need to replace the outdoor unit. last night, the outside unit was running and the unit in the attic was running and the copper pipe was cold and wet, HOWEVER no air was coming out of the vents all over the house. Do you have an idea WHAT IS THE PROBLEM ? My question: Do you have an idea How much it costs to replace the outside unit ?


... Air Conditioners

I have a Sanyo Split System the indoor unit is a KHS0921 and the outdoor unit is a CH0921. When i first turn the indoor unit ON the fan will run for a few minutes and then go off. The outdoor unit never comes ON when there is a cll for cooling. The only way to get the fan to come ON again is to turn the breaker OFF and then back ON. The Operation loght will come ON when the fan is running but it will start flashing when the fan goes OFF. What should i look for?


... Sanyo Split System Air Conditioner

Mini split. Outdoor unit runs for 5 min, then shuts down. Indoor unit continues to run, just blows cold after outdoor unit shuts down. Refrigerant level is good


... Soleus Mini Split Air Conditioner

Outdoor unit fan always runs even when indoor unit is off. I have disconnected all control wires from the headunit (at the outdoor end to rule out faulty signalling). The fan runs all the time, with just the supply wires connected. All connections to the unit are correct. Any ideas??


I have had this problem with a Fujitsu unit before. If the power is supplied to the outdoor unit first but unit is meant to have power supplied to indoor unit first, outdoor will only stop when power is cut off! In that case, you will have to run the ... Panasonic Air Conditioners

Even I turn of the indoor unit via the controller , the outdoor unit is still running. I turn off the breaker and turn on still the the outdoor unit still running. What do you think the problem is?


Usually when this occurs it is a contactor burnt shut. If left to run, it will freeze the outdoor condensing unit into a block of ice. The contactor activates the compressor andfan and the contactor is controlled by the low voltage from the th ... Frigidaire Air Conditioners

Hi the outdoor unit turns on ( fan runs) the indoor unit does open, no heat or cold air blowing. In just fan mode the unit works fine etc speed setting ok. Its a sharp split type air model # ae-a244j outdoor,ay-a244j indoor unit what would be the problem, theres only two parts in the outside unit behind the side plate where the wires info is,small black box three wires and a round unit with wires. I hope this is help full cheers andrew


My gut says that this is evidence of a bad control board(circuit board). As usual, double check that your batteries are good in the thermostat. I have seen some weird things happen when the batteries are low. This one may be a job for your local con ... Sharp Air Conditioners

Compressor problem? My outdoor unit comes on with the fan blowing just fine. Then I hear a buzzing sound for about 2-3 seconds which I believe is the compressor trying to come on. (Incidentally, a couple of lights inside the house seem to dim at the same time that the buzzing sound occurs.) The buzzing sound reoccurs every couple minutes while the outdoor unit fan and the indoor blower both continue to run. I have shut down both the outdoor and indoor units for a couple hours and tried restarti


The buzzing is your compressor trying to start. It is going off on internal overload caused by heating up of the motor windings.If you have an amp meter you could check the amp draw of the comp against the locked rotor amps listed on the tag You cou ... Ruud UBHC Air Conditioner

Fujitsu mini split outdoor unit not running, but indoor unit is running after turnning on


Check the disconnect switch and make sure that both the fuses are good and not shot. If one is shot then the system wont work. There are two fuse. Also be careful due to you will be working around 210 volts ... Fujitsu Air Conditioners

Carrier central air 38ckc060301 problem, unit will not start, air handling blower runs, can hear hum at outdoor unit. I turn the unit off at themostat. let sit for ten minutes, turn back on at themostat, unit starts and cools. Will run through serveral cycles and then not start until I repaet process, any thoughts?


... Carrier Air Conditioners

AC Starts normally but after some time of coolinf compressor in outdoor unit trips. Compressor running light in indoor unit remains on and outdoor unit fan remains on. But no cooling. After a break of about one hour AC works again and problem repeats.


Probably overheating. Check the outdoor coil and see if it is stopped up with dust, grass etc. If so, disconnect power to the unit, and clean the condenser coil with water or air. Be careful not to bend the fins if you use a water sprayer. ... LG Air Conditioners

Indoor unit and outdoor unit not running have voltage to indoor and outdoor unit appears the two circut boards not working one is power supply board the other appears to be micro-prosser board checked fuses on power supply board fuses have continutie but have no leds lit on micro board .


Hi\015\012\015\012Please check the bellow links to diagnose your problem…\015\012\015\012http://www.hvac-f ... Air Conditioners

Model Indoor Unit RAVSM800KRTE Outdoor Unit RAVSM800ATE The air conditioner runs for 20 minutes the shuts of and the operation led light flashes green, the time light flashes yellow the def light flashes organe/red we have had the outdoor unit checked and the compressor and pcb is suppose to be okay but the technician cant get any help to diagnose what the problem is


... Air Conditioners

My indoor unit on my heat pump will not shut off. The electric heat keeps running, and the fan keeps running. It only happens when it is really cold, like 25deg or below, above that and it functions fine. The outdoor unit shuts off, but the indoor stays running. I do HVAC work, but I have never seen a problem like this. I have switched the stat out, and its just so strange. I figured the relay may be stuck, but if I turn the stat off, it turns off shortly after which tells me it may not be the c


I would venture to say your stack relay is getting stuck. either that or you have a short in your low voltage wiring somewhere that is not always making contact....or it may be making contact through another median...like ice or frost. Remember ele ... Intertherm P3RA-036K Air Conditioner

Outdoor unit does not start. indoor unit fan does run.


By the sound of it the relay in the outdoor section is bad ... Air Conditioners

INDOOR UNIT IS RUNNING AND OUTDOOR UNIT IS NOT END


DO you have the owners book that might tell what the three flashes mean? \015\012Try turning off power to both sections (they may be on the same breaker set). This may allow you to see if the outdoor section will try to run or if it has a bad fa ... Fujitsu 24C1 Air Conditioner

I purchased an Amcoraire split system unit for my 2 story garage. Licensced electrician did the wiring and licensed HVAC co. installed the 2 indoor units and outside unit. Outdoor unit is Model # AOM 243 HX 24000 BTU Indoor units are both Model #AWM123 HX, 12000 BTU each When I turn the unit on, it runs for about 60 seconds and then I get an error code on the inside wall unit that says P7. My manual says this has something to do with voltage. I had the power company come out and they show the


Since the manual says the error code has something to do with voltage it means the voltage is either too high or too low. And as the electric company says the voltage is within limits the the error is as a result of the voltage fluctuating. All you h ... Amcor Air Conditioners

Hi, We have two Paragon split systems which effectively cool our large home. One system is playing up. It started 3 days ago where there is water dripping from the front of the unit and the green 'run' light is now flashing. I tend to think it's blocked somewhere, buy my husband cannot find where to check this. Our outdoor units are both under the house with very effective ventilation but the last 3 days have been extremely humid, however the other system is running perfectly. Any ideas? Thanks,


More then likely the blockage is inside the a-coil section. At the drain. To get to it easier remove the pvc drain line. As the drain line comes out of the collection pan it goes into a pvc line the 90 degrees elbow goes to floor. So cut the lin ... Air Conditioners

I have a Maytag S3BA-024KA Split System Air Conditioner. I have power to the system indoors and outdoors. The outdoor unit is clean and the Contactor is also clean with power going into it. The compressor is not running. I can push the contactors and the compressor fan will run but it will not operate by itself? Not sure what to do now.


... Air Conditioners

SAME PROBLEMS 18k btu mini-split sys turn on blowing cold air for 3 mins, then turns warm for 3 mins then shuts down however the run lite blinks at 4 times intervals. outdoor unit fan alway runs at slow speed, even at start up. cleaning outdoor fan cleaning dont help. whats next? maybe the caps? thanks mike (us navy) at [email protected] in norfolk,va FAN MOVES FREELY, EVEN BY WIND BLOWN.


Glad to hear the issue is resolved.\015\012\015\012With regards. ... Air Conditioners

My goodman minisplit outdoor unit led flashes 5 quick times then off for a couple of seconds then 5 quick again, indoor unit runs but outdoor will not


... Goodman HDC12WMC12 Air Conditioner

My outdoor air unit runs but the indoor unit is just buzzing and the fan is not running. Any idea whats wrong


Replace the capacitor to the in door fan motor. If it still does not run,you will have to replace the fan motor also. ... Carrier Air Conditioners

On my Goodman CPLJ30-1B unit what size is the outdoor unit dual run capacitor?


... Goodman Air Conditioners

Not a GE unit. I charged unit with refrigerant and powered up unit. After running for @ a minute it shut off, having no power light at all. I found a set of wires reversed that were going to the outdoor unit. after fixing the wires i can't get the unit to come back on. The breaker is not popped and I assume there is some kind of fuse or overload that I have to manually reset or replace. It is a chinese (i think) made unit Air Control


Since most of these units, come precharged for line sets up to 125' in some models, the fact that you charged it, concerns me. Second you made no mention of the king valve, did you open it.\015\012 Then your diagnosis speaks to overvcharge, an ... GE Quiet-Aire Ductless Mini Split System Air Conditioner