Having problems with your Air Conditioners ?

Heated air coming out when unit is in Cool Mode

\015 Heated air is coming out of the vents when the unit is on Cool Mode. Outside at the condensor it feels like the cold air is being exhausted to atmosphere. I believe the unit is not reversing the cycle. Heat Mode is functioning properly when selected. Cool cycle is the problem.\015

Answers :

Heat pumps are sometime constructed to "Fail in the heat mode." It could be either the t'stat or the reversing valve. Be sure the t'stat is wired correctly. Usually the"O" terminal is for the reversing valve on the outdoor unit.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a goodman heat pump (gsh 130241AA), it's 2 years old. the heat pump will not come on in either heat or cool mode. this is my downstairs unit, my upstairs unit works fine. the air flow is working fine, just nothing cool with the downstairs unit.


... Goodman Air Conditioners

Heated air coming out when unit is in Cool Mode


Heat pumps are sometime constructed to "Fail in the heat mode." It could be either the t'stat or the reversing valve. Be sure the t'stat is wired correctly. Usually the"O" terminal is for the reversing valve on the outdoor unit. ... Air Conditioners

Lg Neo plasma inverter split model s18ahn isn't heating or cooling properly. When in heating mode air con will go into defrost/preheat mode for 5 minutes and then air con will blow out air for 5 seconds and then go back into defrost/preheat mode. When in cooling mode indoor fan will pump out air but will not get cold. In both heating and cooling modes the outdoor unit will not start up and the outdoor fan will not spin. I have just replaced the main pcb board and that hasnt made a difference. Bo


... Air Conditioners

No Heat Unit works fine in cooling, auto and dehumidification modes but when you select the heating option, the defrost light turns on with no air coming through. Have cleaned the dust filter and outside unit is free of any blockages. Trouble shooting guide in instruction manual does not address this problem. Any help would be appreciated.


In heating mode, the outdoor unit should run to build up pressure and hence heat. To facilitate this, the indoor unit fanmotor will only come on once a sufficient pressure is reached. If you are a bit low on refrigerant, this may not happen. Or it co ... Air Conditioners

Pace Air 24HPEW-HEC Unit will not heat, though heat mode comes on, dehumidify and cool mode work, and fan works as advertised. Fault Code E4 presents at startup. Manual is off site. What is this code telling me?


If unit displays "e4"1? Check whether the winding resistance andoperation current of the compressor are normal.2?Check whether the high and low pressure is normalwhen the unit is running.3?Check (whether the ... Pace 12ACXWHEC Split System Air Conditioner

In heat mode thermostat set for 68 and room temp on thermostat reads 68, but unit contines to run. The air coming through vents is cool air. Unit never shuts off, runs constantly. This is the case when outside temp is 30 degrees or 45 degrees.


Could be under sized unit or fan relay on unit. ... Goodman PHKJ024-1 Air Conditioner

Amana PTAC Unit is not producing heat. Fan works fine. can not locate manual reset for heat although a label on the unit says there is one. I have an Amana pth153b35ae ptac unit that the heat will not come on. The compressor will run in the cooling mode but not in heat mode. I verified the switching valve is working and the capacitor seems to be fine as the compressor will run in cooling mode. The thermostats seem to be functional because relays can be heard clearly when changing temperature se


I know this is late but I had to add a solution to this problem since I had the exact same problem and was able to solve it. The probelm is not your control board. On these units, the heat pump compressor will not kick in unless the temperature you ... Amana PTH123B25AJ Heat Pump Air Conditioner

I HAVE A 2000 HOLIDAY RAMBLER WITH TWO AIR CONDITIONERS. THE REAR A/C WILL NOT COME ON UNDER ANY MODE (FAN ONLY,HEAT PUMP OR COOL)WHILE IN ZONE 2.WE HAVE BEEN ON 50 AMP SERVICE AND IT STILL DOEN'T WANT TO TURN ON.ZONE 1 (FWD A/C UNIT )WORKS FINE IN ALL MODES.115 VOLT A/C IS AVAILABLE VERIFIED AT THE UNIT CONTROL UNIT.3 AMP FUSE IS OK.ANY IDEAS ON WHAT IS WRONG? PS THE FAN ON THE AFT UNIT TURNS FREELY. STERLING SNOW


Have you tried running both, when plugged in, as well as generator running? What about testing voltages etc at terminals on control boxes, has anyone done that? Just in case this unit is new to you, are you sure there is no extra switch that has to b ... Dometic Rooftop RV Air Conditioner

Thermostat setting I just bought a new house and I have a heat pump-we live in North Carolina. The name on the thermostat is Braeburn and it is a multi-stage 2 heat/ l cool digital thermostat. We have it set at 68 and when the blower first comes on it blows warm air-however then it switches to cool air. And sometimes cool air comes out first. We have set both stages to 68 and it is in the heat mode. Should the 1st and 2nd setting be different?


What i would do is see if the outside unit is working at all. when you first turn it on the air was warm due to the fact that the temperature inside was cooler than the set point. when it get within 2 degrees ... Weather King 12AJA6001AH Air Conditioner

Heating problem hello! My air conditioner stopped to heat. (there is a around 8 degrees C, outside and 16 degrees inside). It worked just fine, and now, when I switched to heating mode, there was nothing. the defrost LED ond the inside unit is switched on, but air is not comming from the unit. Cooling mode works fine. If you could please help me finding the solution for my problem. Thanks in advance. RAdan GE AIR CONDITIONER SPLIT SYSTEM WON'T WORK ON HEAT CYCLE Seems to work ok doing eve


Hi Radan, Did you get this problem solved? We have an Electrolux Kelvinator Split System and ours is doing exactly the same thing. I am struggling to find a solulution. Would be great if you can offer any advice.\015\012\015\012Thanks Nic ... Air Conditioners

Friedrich YM18 230 volt heat pump. The unit has heated and cooled well for about 5 years. Just started heating mode recently and the unit no longer heats. Fan runs OK. Was able to get the heat strip to run for a few minutes (smelled the dust accumulated over the summer burning off). Now, no heating whatsoever. When in the "Money Saver" mode, nothing happens. Fan will not come on and unit will not heat. With "Money Saver" mode off, the fan runs.


... Friedrich Air Conditioners

Heating problem hello! My air conditioner stopped to heat. (there is a around 8 degrees C, outside and 16 degrees inside). It worked just fine, and now, when I switched to heating mode, there was nothing. the defrost LED ond the inside unit is switched on, but air is not comming from the unit. Cooling mode works fine. If you could please help me finding the solution for my problem. Thanks in advance. RAdan


The LG>LW5200ER AC is not listed as a heat providing unit. Click on link and this will give you the spec's\015\012\015\012 \015\012\015\012 ... LG LW5200ER Air Conditioner

After a cooling cycle, when the thermostat call for more cooling, it take up to 5 minutes after the air handler starts for the compressor motor to restart. The top fan operates on the outside unit, but since the house is not circulating cold air, only the room tep air the house heats up about 3 degrees before the compressor comes back on and cool air begins to come from the ducts. Yes. I know there is a safety feature to protect the compressor, but can the cycle be shortened?


No, this cycle cannot be shortened due to the simple fact that this feature is in place to protect your system. Even if it could be, I wouldn't recommend it.Mat ... Coleman Air Conditioners

Amana PTH153B35AK This unit is less than 30 days old, heats fine cools fine, but when i have it in heat mode,set @ 70 or so, as soon as the room heats up, the unit will cycle into a/c mode and blow super cold air for about 5 minutes than return to heating. Sometimes it will reach the desired temp. and turn off like it is supposed to do, but for the most part it just cycles back and forth from hot to cold...Amana has the worse help/service i have ever seen, i was on the phone for an hour,everybod


This often happens if the unit is oversized or to close to a wall or object. ... Amana PTC153B35AK Air Conditioner

I HAVE AN AMERICAN STANDARD HEAT PUMP/AIR CONDITIONER UNIT OUTSIDE MY MOBILE HOME A FEW DAYS AGO A UNKNOWN SMELL COMES THRU ALL VENTS IN AIR CONDITIONER MODE ONLY. WHEN HEAT IS ON THERE IS NO SMELL UNTIL IT GOES IN DEFROST MODE AND THEN IT SMELLS ONLY A FEW SECONDS , WHEN HEAT COMES THRU IT STOPS. I NEVER HEARD OF THIS. THANK YOU


This is a condition called Dirty Socks Syndrome air cleaners and dehumidify usually fix the problem also adding a uv light to the duct can remedy the problem the light is probally the cheapest solution ... LG LS-K1830CL Cool Mini Split Air Conditioner

We installed a Honeywell RTH230B thermostat on a Trane XE60 Air Handeler this winter. When we put the system on heat it works fine. However, when we put the system on auto for cool the compressor fan comes on but not the air handeler fan. On the air handeler the terminal strip from left to right is R W Y G B/C. The red wire on the R terminal comes from the contactor on the compressor unit. The other wire from the compressor unit is connected to a gray wire that goes to the thermostat. The W


I ran into this before and had to call Honeywell for help in the wiring...it seems the wiring was not done to standard, and they were able to help me get it straight in about 10 minutes and at no charge. ... Air Conditioners

I have a Goodman air and heating unit model#gsc130601bc and the problem is the unit comes on but the fan does not, also the unit gets hot and no cool air is coming out of vents in the house. What can I do to fix it?


... Air Conditioners

Hi, I have a wall mount midea split a/c model- MSG-36HR that will only heat. when put in cool mode it only blow's room temp air and the outdoor unit won't run. On heat mode it works normally. I have cycled power a couple of times, changed modes on the remote numerous times and just in case, changed the batteries in the remote. The unit is about 3 yrs old. Do you have any pointers. Cheers Tom


Most heat pumps are 'fail-safe to heat'. That is: the normal position of the valve which reverses the function is in the position which provides heat. The reversing valve must be powered to switch to the cooling position.Although the ... Midea Air Conditioners

I have a 2 year old Duo Therm 15,000 btu Heat Pump AC unit in my RV. The compresser will not come on or even try, in either cool or heat mode, the fans runs in either auto or on position. I have a wall thermastat, all wires & connections at the thermastat and the controll box look good. The units was running fine, with no prior symptoms and then it just stopped cooling. I have a strong electrical background with all the meters, I am just not famaliar with RV AC units. Bud De Fore don


Hello Bud,First of all, is your wall thermostat a digital thermostat, like a 4 or 5 button Comfort Control Center? Is the ambient temperature under 40 degrees?Is your fan still able to run, are you able to control ... Dometic Rooftop RV Air Conditioner

My air conditioner stops cooling. Occasionally, it will just function on fan mode even though I confirm that it is on cool mode. Warm air comes out even on the absolute coldest setting. I have to turn it off and use the manual reset button on the plug to get it to work properly. The problem started after the unit iced up one night and it hasn't worked right since. Is there any way to fix this or am I gonna have to get a new AC?


If after reset the A/C cools then the fault seems related to the thermostat or the cut off pressure switch or load cut off.\012However is there is no cooling at all the compressor and the gas pressure- check for leak if gas is absent.- must be ... LG ZW6500R Air Conditioner

We live in southwest Florida. Our HVAC system consists of a air conditioning system with heating coils when it is cool. Yesterday morning we tried the heat nothing come on. Later in the day I tried the air nothing. I tried turning in just the fan nothing. I just checked the breaker I have power where the wires are connected. I went out to the outside unit and pulled the cover. Pushed in a spring loaded plastic switch the fan on outside unit works and shut off when I released the switch. But noth


Hello. Sounds like you do have power. That spring loaded plastic switch is a 24v contactor. It pulls in when energized. If you push it in manually everything shoud run normal. Ck your 24v transformer. On one side (feed) you should have 115v or 220v ... Air Conditioners

I have a Ruud Heat Pump system. The outside unit makes a humming sound in either heat or cooling modes. The fan won't come on. In cooling mode, the compressor starts up, but them shuts off after about a minute.


Sounds like your condencer fan motor is stuck. Can you take a long rod and when the power is off to the outside unit, spin the fan blade? Maybe it will be enough to get it working again. ... Air Conditioners

Its a trane unit model# TUE060A936K3 in cooling mode condensor comes on the indoor fan does not in heating mode every thing comes on but the blower fan does not there is not a led light blinking code lable on the unit i it looks like its giving 4 blinks pause and repeat 4 blinks etc. what does this mean


Hi,\012Either the vent is blocked or the pressure switch that tells it that the purge blower is running is not working right...for some reason that switch is not making contact and so it will not let it light..\012\012heatman101 ... Air Conditioners

I have a comfortmaker unit with heat strips. The blower fan comes in and blows cool air. I have checked voltage at the transformer, and it is producing 24 vac. The contactor for the fan and condenser never pull in so I replaced the defrost control circuit board. Still only blows cool air and the defrost cycle never comes on. I jump 24vac to the coil on contactor and the defrost fan came on and the condenser came on so the fan motor and start/run capacitor are good. Any suggestions.


... Air Conditioners

Hello, When I set my AC unit to "Heat" and turn it on, the air will come out warm, then after a few hours the air starts to come out cool. To make it warm again I need to set the thermostat to Off position for a few minutes then turn it back to On position then the air comes out warm again. Any idea what could be going on here? thank you!


It sounds like you have a heat pump. When you first turn on the system the heat strips will come on and produce warm heat (referred to as supplemental heat strips), as temperatures rise the heat strips will turn off and the "A" coil will just exchang ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific