My air handler comes on ,not the outside unit when my thermostat is in the off position even if i turn the thermostat down to 50 and have it turned off the air handler comes on for about 5 to 10 minutes and then kicks off. this happens approx every 20 min to 30 min.Whats goingon? Bad thermostat?


Answers :

If you have a standard thermostat the fan switch is for the air handler only. It completely over rides the thermostat for most settings. Now lets see this is what I'd expect:
fan switch on Indoor fan runs all time
Fan switch auto Indoor fan only runs when thermostat is set to cool or heat and the thermostat is turned up above room temp for heat or below room temp for cooling. In both of these modes the furnace blower comes on and stays on til the room temperature is satisfied. The outdoor unit only comes on for AC the out door unit will not come on for heat or the "on" setting on the thermostat. See exception 1 & 2 below...

Exception 1- (in a heat pump the out door unit runs in both heat and cool mode\015\012unless it has emergency heat turned on then it will not come on outside\015\012in the heat mode, and depending on the type of heat pump and furnace or\015\012air handler it is). A heat pump thermostat usually has "backup heat" and an "emergency heat" setting switch on the thermostat.
Exception 2 - On some thermostats they are made to cycle on the heat if the temperature reaches a preset temp (around 50'f usually but definitely by 40'f). This mode prevents freezing when if instance the homeowner is away or while the home is under construction. In this mode the fan inside can run but the heat usually comes on with it.
Exception3 - On some electric furnaces the heating strips may be individually controlled and thus not all come on at one time. This may give the feel of no heat especially if the room is cold.

Now there may be other exceptions but Ive tried to give you a heads up on some of the most common ones.
If you need more help please post more specifics about your unit/system as to for sure what switches are set to what setting and what is happening with each. My first though was that maybe your system is OK and you needed to know if the thermostat was working properly.

If this helpd you understand your problem would you please give me as hifgh a mark as you can. Thnaks for using fixya and good luck.
Temperature sensor within the air handler duct

Is the temperature within the unit reaching a point where it calls for the blower to come on or is it the sensor?

Depends on where the air handler is located.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

My air handler comes on ,not the outside unit when my thermostat is in the off position even if i turn the thermostat down to 50 and have it turned off the air handler comes on for about 5 to 10 minutes and then kicks off. this happens approx every 20 min to 30 min.Whats goingon? Bad thermostat?


If you have a standard thermostat the fan switch is for the air handler only. It completely over rides the thermostat for most settings. Now lets see this is what I'd expect: fan switch on Indoor fan runs all timeFan switch auto I ... Carrier Air Conditioners

A Nordyne air handler, model B3BV-030K, with 4 wire thermostat. Thermostat and AC works fine in "cool". Switch it to "heat" and nothing happens.No fan, no heat.(I have built in heat strips -resistors). I jumpered (on the nordyne circuit board-input from thermostat) from R to W. (24 volts from R to W, which should start the heater. Nothing. No relay "click" like when AC comes on. If i jumper R to Y, AC comes on ok. Does this sound like a relay gone bad on the circuit board? Or what? If relay bad,


Do you get heat when you jumper R, G & W? ... Ruud Central System Air Conditioner

This is a central air conditioning question. I have no power to the "battery-less" thermostat. I have two thermostats in the main house and swapped them out to see if one of the thermostats is bad, but both thermostats are working. There's just no power to the terminal in the living room. I checked the 5amp fuse to the air handler, and it's good. I checked the A/C unit outside and pressed down the contactor, the a/c kicks on. What am I missing?


Are you getting 24 volts from the thermostat to the transformer in the air handler? Sounds like the transformer in the airhandler. You can check it by taking the voltage from the R termianal to C Terminal and should read 24 volts. ... Air Conditioners

Hi, my air handler, when the thermostat is on auto will usually turn on but sometimes it doesn't. When the thermostat is set to "on" it always comes on. This has happened with 3 different thermos


... Air Conditioners

I have a problem with my central heat / air unit. As it is getting cold now, I am using the heat. My problem is that I must turn the thermostat to the on position to get the unit to come on. In the auto mode, nothing happens. I can get very cold but not ever kick on until I move the switch to the on position. In the on position it works fine. Thinking that my problem was with the wall thermostat, I replaced that. I do not remember having this problem with the A/C. What should I look for to fix t


Look on your thermostat one switch (for the fan) will say off/on/auto. The other switch (for operation mode) will say off/ac/heat. The switches should be set at fan auto and mode heat. Some have an auto for the heat/ac if that is the case your thermo ... Air Conditioners

Approx 2 years old. quit working during recent rain storm. have a backup furnace that kicks in when temps go below 35 degrees. new carrier thermostat (1yr old). furnace fan comes on blowing cold air, but heat pump does not come on. can go to e-heating and furnace works fine. no fuses on heat pump, no reset button and circuit breaker is fine. believe this is electrical, not mechanical. thanks


It sounds like the contactor is not pulling in . corrision maybe even a bug could prevent it from pulling. ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

I have a Jantrol heat pump & A/C. It is approximately 10 years old. For the last 3 summers the compressor unit will freeze when the air handler fans fails to come on. It worked fine for 2 weeks this year before it happened. I've be able to thaw it out and restart the unit and it works from days to weeks before this occurs again. The last time it happen, I had a problem getting the air handler fan to come back on, but it did eventually. I've been thinking it may be the sequencer, but now I'm wond


Hi,\015\012\015\012If you can safely check the supply to the motor when it should be on, then this is the best method to check it.\015\012\015\012Check the fan turns very freely - oil the bearings if it doesn't.\015\012 ... Goodman Air Conditioners

MY RHEEM CLASSIC SUPER QUIET 80 BLOWS COLD AIR EVERY TIME IT KICKS ON AND ENDS EVERY CYCLE WITH A MINUTE OR TWO OF COLD AIR. THIS HAPPENS EACH TIME THE FURNACE KICKS ON EVEN IF IT JUST WENT OFF MINUTES AGO....HELP!!!


... Air Conditioners

After a cooling cycle, when the thermostat call for more cooling, it take up to 5 minutes after the air handler starts for the compressor motor to restart. The top fan operates on the outside unit, but since the house is not circulating cold air, only the room tep air the house heats up about 3 degrees before the compressor comes back on and cool air begins to come from the ducts. Yes. I know there is a safety feature to protect the compressor, but can the cycle be shortened?


No, this cycle cannot be shortened due to the simple fact that this feature is in place to protect your system. Even if it could be, I wouldn't recommend it.Mat ... Coleman Air Conditioners

We have a Goodman Furnace and Air Conditioner approx 7 years old. When I put the Cool on thermostat and lowered the temperature for the air conditioner to come on the furnace fan started but the outside air conditioner only made a humminging sound. How long does it take for the air conditioner to start? I thought in previous years it came on quickly. I changed batteries in thermostat and reset the brakers on the main electrical panel. Could you please give me some advice. Thank you.


Hi, You are right. The outside unit starts quickly. The humming will either be the evaporator fan or the AC compressor itself. If you can reach into the evaporater fan with something narrow and stiff you may be able to see if the fan turns. Sor ... Air Conditioners

I have a suburban lp furnace and duotherm air/heat pump roof unit. duothern thermostat. 20 amp breaker kicked ( reset breaker) & furnace quit. NOW furnace fan comes on but does not light, and the front AC will not work either, when in the COOL position on STAT the unit blows warm air instead of cold. I replaced the Thermostat and a Tech guy checked the board in the furnace and it was OK. He also switched the board from the rear air with the front and nothing changed. Rear air and heat pump works


I'm not sure what the problem may be but you could try calling All\015\012Seasons RV Appliance Parts & Service. There number is\015\0121-800-344-0673 they have helped me in the past. That and there tech\015\012calls are free so it wouldn't hurt ... Dometic Rooftop RV Air Conditioner

I have a ruud achiever 10 model UPKA-018JAZ with air handler in attic. Was wondering if this is a single stage heat pump or a multi stage? trying to connect new thermostat, air conditioner is working but when turn on heat only the fan comes on and the compressor outside never comes on to warm..but compressor does come on when switch to cool..


This may be as simple switching the thermostat to electric, under the cover is a gas/electric dip switch. Hope that helps. ... Ruud Matching Split Air Conditioner

My central AC is not blowing any air through the vents , the air handler is going the outside condenser is going but no air circulation only a small amount in the bathroom no other place.How can I jump the thermostat out to see if that section of the thermostat is bad. I have a White Rogers S.P.D.T. CLG 1.5 Amps. Max MTG: .15 to 1.2 Amps Max. 30 Volts A.C. TYPE 1F56W-444 . LR27935 0321 Class 2 Rev. D . How can I jump this out to see if the fan section is activating the system. I want to see


Check for fan blade obstruction, possibly something binding up the blades of the fan stopping your air circulation, also the duct work may have come loose from the main air supply register, dropping off air to the rooms, it could be something as simp ... Air Conditioners

My air conditioning units work. They are cooling. The thermostats say 76 degrees. The problem is the hot dry smelly attic-like air that is constantly circulating and blasting down on me from the air vents. I have dry red eyes, a raspy dry throat, stuffy and bloody nose. (I am not sick. This happens every afternoon, all summer long.) This all happens during the hottest time of day, past noon and into the early night. I have had A/C techs out here to check the units and check the flow in the house


The techs probably checked the units operation,but did they get in the attic to see that the duct work on the return air side of the unit is tight and not sucking in the attic air. ... Air Conditioners

I have a honeywell pro 2000 programmable thermostat which controls an enerzone ahc 31-18 series water source air handler with heating and cooling coils built in. This therostat and heater worked fine all winter. Last week i had a air conditioner stalled and connected to the air handler and the AC worked for one day. When i tried to turn on the AC yesterday, the fan would not come on for either AC or heat. any troubleshooting suggestions? thanks ... Donald


... Air Conditioners

I have a york hvac system that is 5 years old. I have the thermostat set at 74 and when it turns on only the fan runs circulating the existing air in the house about 20 percent of the time. The ac works great when it is running but i'm wondering why it doesn't always come on. Just replaced the thermostat thinking that was the problem but it did not help. Sometimes after the fan runs for a half hour or so the ac will finally kick in and start blowing cold air. The lines are not frozen at a


It sounds to me like you have a delay on start timer on the compressor that possibly is starting to fail or someone may have adjusted the time band up on it. I myself would remove it and install a delay on break timer and a 5 minute setting would be ... Air Conditioners

The compressor in my central air unit does not kick on. Sometimes it will sometimes it won't. I really notice when it doesn't because of the scorching heat from outside. Basically when the air is off all night, which I don't run at night because it is to cool, but in the morning when the thermostat is set for it to come back on the compressor won't kick on for a couple of hours after if at all. Please help me figure this out. I'm pretty handy a do it yourself projects.


Sounds like you may be low on charge and going off on internal thermal over load.Just a guess though. ... Air Conditioners

My goodman air unit wont turn on but has power to the relay and can be manually overridden at the relay but doesnt sound like the air handler comes on. I changed the batteries in the thermostat and even switched the thermostat with my second unit on opposite end of house. I also thought it might be the run capacitor again so I changed that already. Any ideas?


Check the transformer. There could be a chance that the transformer is out. If you mean you can manually turn on the unit by pushing in the contactor switch in then theres your problem The thermostat engages the low voltage side of the transformer ... Goodman CLT24AER24 Air Conditioner

My air handler runs but does not cut out, once it reaches the temperature set in the thermostat the external unite kicks off but the fan in the air handler does not stop running.Looking for a relay or switch that's hanging up but not sure. Please help.


If you have old thermostat and it worked when you switched to scheduler, try reinstalling it to see if problem persists. depending how it was wired, shut off sensor may disable furnance controller (not air handler). odd thing is handler runs nonstop ... Ruud UBHC Air Conditioner

My unit is running but not blowing cool air. I went outside and the condenor fan was not moving. Took a stick and shoved a blade and the fan started moving but the air is still not cool inside. I did notice the air coming through the unit outside after fan was blowing was cooler than my 2nd a/c unit that was working fine. I wondered if the entire unit was frozen. I turned off unit at thermostat and figured I would see what happens tomorrow


Sometimes on new units it is common for the fan to not start until you give it a push. Did you happen to hear if the compressor was operating? If the unit was froze-up the Insulated Suction line would also be iced over as well. If it wasn`t it is mor ... Carrier 38CKC024 Air Conditioner

My problem is when I turn on my air only kick in for a minute of cold air then it shuts down then warm air comes out for five minutes maybe less. my setting are at max cool thermostat at 7. at these setting my room should be ICE cold.


If it is in the middle of winter that you are doing this it has still got a very slim chance of doing what you want... it is a thermostat afterall which is preset by the manufacturer, take the settings off automatic and turn onto cool only.... atleas ... Air Conditioners

Air Conditioner was working fine last summer but outside fna not working. Not hearing any sound at all. I can move the fan amanually and it seems fine. There is an electrical box next to the main electrical box on the back of the house with 2 fuses in it but I can't tell if they're bad. I thecked the thermostat and it apears to be fine. The air conditioner furnce kicks on and blows air out of the registers. It's just the main unit outside that's not working.


There is a relay in the outside unit. Check for 24 volts a/c at the two wires coming from the furnace. also there may be a mouse nest in the control comartment where the relay is and they tend to chew up wiring insulation and sometimes wires get disc ... Carrier 38CKC042 Air Conditioner

Hello, have a 2/4tec3f24b air handler, less than 2 yrs old. the fan motor in the air handler will not come on.


Most have a run capacitor. replace that. ... American Standard Air Conditioners

Third control board has been installed on a goodman 3 ton central air unit in the attic...the only that happens is when the thermostat calls for cooling...the inducer fan comes on and then the blower motor stays running but the condenser does not come on......There is always 6 flashes on the control board.....which says roll out switch....please help me on this one....Calvin from Memphis


Temporarily jump out roll out switch. ... Goodman CKL42AR42 Air Conditioner

I have a Carrier 38CKC036 Air Conditioner Unit. When I turn the thermostat on cool the compressor comes on but the fan on th unit clicks like it wants to come on but it dont. Could the fan be bad? What do you think the problem is?


Hello, this is one of 2 items...the motor itself, or the start capacitor. The capacitor is responsible for boosting the motor to get it started. Follow the wires from the motor and they will lead to an oval or round cylinder. Check the cylinder f ... Carrier 38CKC036 Air Conditioner