Wiring foe electrical damper

\015 Can't seem to make the electrical inline damper operate. Need copy of Instalation Manual\015

Answers :

Problem solved. Maqny thanks

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Wiring foe electrical damper


Problem solved. Maqny thanks ... Air Conditioners

I am installing a new thermostat for my baseboard electric heat. The electric box has 2 wires comming into it. So I have 2 black, 2 white and 2 ground. The old thermostat had a place for all 4 wires (one side line one side load) the new thermostat is a honeywell RLV430 High voltage (at least I got the high voltage part right). It only has 2 wires so I am at a loss as to what to hook up where. My inclination is to hook the load to one and the line to the other. But I don' know if this is r


Hi tlef\015\012\015\012To answer your question;\015\012\015\012Tie the two whites together with a marette , and the two blacks to the thermostat , it doesn`t matter which wire goes where on the thermostat since there is no polarity.\015\ ... Air Conditioners

As I was cutting weeds away from my outdoor ac unit, I accidentaly cut through a small wire that has a red and white inside of it, we wired them back together and still have no ac or heat or air, we just replaced the thermostate also what should I do now ? we checked the breakers in the heater and on the main electric all brakers are on. I know this wire goes from the ac to the heater to the thermostat what elsa should I try, intertherm electric heater and ac thanks so much


This wire is powered by a small transformer, and delivers low voltage to energize the colenoid that turns on the ac unit. Turn the ac on from the inside. Then check if it is getting the voltage. Usually 24V AC. If not getting the voltage, go to the a ... Intertherm P3RA-048K Air Conditioner

Damper apparently stuck in open and zoned area very hot. disconnected wire to sensor, damper reset and reconnected wire but thermostat is not working now and how HF 42 on screen. Occasionally system comes on with heat but not heating any of the 3 zones above 66 degrees. Is there a way to reset the Comfort Zone system? Manual dated 1996 and is #809-575


... Air Conditioners

Contactor wiring diagram. Need to know how to wire a contactor to switch off electric boiler when electric shower is being used. Thanks


Inter lock two contactor used auxiliary contact if 1 then the other is 0. ... Air Conditioners

I installed Minka remote controlled Ceiling fan for a friend. The fan itself has 4 wires, black,orange,white, & blue. The remote unit has black, white, & blue wires to connect to black, white, & blue wires on fan, and black & white wires to connect to electrical wires in attic. The remote operates the fan functions correctly, but the lights on the fan stay on all the time, with no effect from the remote. I have no manual, and had no place for the orange wire on the fan to go to.The model number


The connections you need to make are \015\012\015\012\015\012Motor to Receiver Electrical Connections: Connect the WHITE \015\012wire from the fan to the WHITE wire marked "TO MOTOR N" from the \015\012Receiver. Connect the BLACK wire from t ... Air Conditioners

Replacing a non-programable thermostat for electric baseboard heater with model CT410B. This is a 4 wire thermostat replacement for a previous 2 wire. Directions indicate that I can do this. I connect wires L1 and T1 to 2 wires from wall [both hot]. Thermostat is not working. Also there is no place to connect ground wire from wall to thermostat. 2 unused wires are just insulated [L2 and T2] Thanks for any advice.


If you take thermostrat back off and connect the wires together will baseboard heater get hot. If not you may have bad heater. If it gets hot your new tstat may be bad. The way you have it wired is correct. Most line voltage tstats have a ground scr ... Air Conditioners

Need to change a broken blower motor in RUUD central air unit. Old central air blower motor (GE electric) was connected with brown and orange wire to 15 MHD capacitor. Another orange wire from central air unit connected to orange motor wire on capacitor. Black wire from motor (Hi Speed) connected to central air unit. Blue and red wires not connected. New motor is an AO Smith FD6000A. Has Black, brown/white, brown, blue,yellow,red, white and black wires. Need to connect to a 5 MHD capacitor. M


On the motor should be a diagram detailing the wires. brown white goes to either side of the capacitor and brown wire to other side of capacitor. hi speed goes to normally open contact on the indoor fan relay and the wire designated common on the mot ... Air Conditioners

I bought a replacement Dayton electric condenser fan motor. The original GE had 3 wires. L1 L2 & the fan capacitor wire. The Dayton replacement model 4MB21 has 4 wires, L1 L2 and 2 capacitor wires tan & tan/white tracer Where does the other tan wire go


The tan/white wire can be insulated/capped and not used. Use and ohmmeter to take a resistance reading between the tan/white wire and L1 & L2. There will be no resistance between the tan/white wire and one of the others. This will be the common w ... GE Air Conditioners

On our inside unit we have a serious problem. The condensation from the unit leaks down into the electrical system(being on the bottom) of the unit. I was told it was a design flaw. how do i keep the water from dripping on the electrical. Weve had to replace the electrical wires and boxes 3 times, have spent over $1000. Please help, we cant keep replacing the same thing.


U can try to get some good insulation wrap and wrap the coil box and also is the unit in a basement or attic if basement u can also ry cuttting a few vents in the dct down there like 2 6 inch by 10 inch holes and the unit wont create condenstaion i ... Air Conditioners

Wiring heat only thermostat to inter therm central electric furnace had to replace fuze block, limiter, and sequencer thermostat only has one red wire and one white wire


I am trying to install a Honeywell VisionPro 8000 thermostat for my Intertherm Central Electric Furnace but I am having trouble getting to work any suggestions? ... Air Conditioners

GE Zoneline HP PTAC A3B688DAALW1 WIRING DIAGRAM? Found a 6" L white wire with 1/4"F stake-ons loose from center terminal of Compressor capacitor 20/5uf going into the back wiring compartment. Not sure where it came loose from. There is a black multi stake-on terminal block up inside behind the capacitors. Attached it there to a unused spade but now fan does not run the indoor fan when in heat mode (compressor or elect. heat). Before the fan and electric heat worked but compressor just buzzed try


... GE Zoneline AZ55H07D Air Conditioner

Wireing specs for ainterterm electric heat unit [e2eb012-ha ] unit my wires burnt becouse ac water trap was stop up


Go to a supply house that sells that brand or chek out the website. ... Intertherm Air Conditioners

I have a goodman heatpump a when i turn the thermostat on heat the electric elements works but not the compressor i check with a volt meter and i have 240 volts at the contacter 24 volts at the defrost board on the condensor .the red wire is hot .question'the white wire from the t-stat being energize from the board or the t- stat


From the tstaT ... Goodman Air Conditioners

I need a wiring diagram for an Intertherm electric furnace with a Nordyne fan control board no. 624-5680 and 20kw of electric heat. Does anyone have one?


... Intertherm Air Conditioners

I have a wall mounted gas heater. We have the pilot light lit but when I turn up the thermostat, nothing happens. The thermostat is newer as of 8 years and the electrical unit that attaches to the pilot light is about 8 yrs old but the wiring inside the wall is probably 30 yrs old. any thoughts? I just sanded the electrical connection and no change. thanks Margaret


... Air Conditioners

I have a carrier 38YKC036300 heat pump with an electric furnace. I am attempting to install a new bryant T6-PRH thermostat http://www.catalog.bryant.com/wcs/proddesc_display/0,,CLI1_DIV42_ETI4641_PRD1583_SIT70,00.html. The wires dont exactly match up with my old existing thermostat. My existing thermostat has the following connections: W2, C, R, G, E, O, and Y. My new thermostat has Rc, Rh, W/W1, G, Y/Y2, C, O/W2/B, Y1. Please tell me which wires go with which terminals on the new thermostat. P


Old Tstat New Tstat\015\012R Jumper Rc & Rh\015\012E W/W1\015\012G G\015\012Y Y/Y2\015\012C ... Carrier 38CKC036 Air Conditioner

Elect My electric baseboard have 2 wires and a ground 220 ,is this the power I would need for mini split cond ,120-230 60hz 1 phase that has 3 wires cumming out


HELLO,The voltage at the power outlet must be 120V, this is the power rating for 60hz power.Did your split ac has power supply unit (PSU), that converts main power to 120V into the much DC voltages utilized by the equipment? ... Air Conditioners

Wiring diagram i've got a GE electric fan motor. says 208-230 volt, single phase. numbers painted on motor are GBDQ 5861A. five wires coming out of motor, black, white, red, orange and blue. what are these supposed to be hooked to? squirrel cage fan motor. appears to have been part of a colling unit. thanks, glenn my email is [email protected]


The white wire is nuetral, if you are trying to make a shop fan or something like that then you hook it to the white wire which goes to the wide spade on the outlet. The black one which is the hot and goes to the smaller blade (looking at an outlet ... Goodman CLQ36AR49 Air Conditioner

I have a Bryant 561C central air, 5 years old, The Motor on the outside unit of this air conditioner went out, trying to sve some money on a service call I ordered the new motor and put it in my self and was able to make it run but no cool air inside the house. The motor that I took out was made by General Electric with three wires coming out of it, now the new motor I bought was made by Emerson with 4 wires coming out of it, also the lady from the Bryant dealer where I bought the motor also sen


Hi there, \015\012\015\012here is the wiring diagram of you air con unit...\015\012\015\012http://w ... Air Conditioners

I have an older sears and roebuck gas pack A/C unit that the electric co. put a energy cycler on. Since then the heat doesn't work and I need a wiring diagram to check the control wiring and get the heat back working.


This could be hard to find as Sears used other brands to put their name on. It could be a Heil unit. If the wiring diagram is not glued to the inside of the removable panel you could try taking the serial number to Sears and find out who made the uni ... Air Conditioners

I need someone to coach me on the installation of a breaker kit to replace the fused disconnect on a Nordyne FEH17 electric furnace. I've got the kit and the wiring diagrams and I've done a little bit of household wiring in the past but I'm a bit hazy on what goes where. I can provide photos of the furnace.


What country are you in? ... Air Conditioners

Replacing robertshaw thermstat 9520 with a Robertshaw 9420. On older thermostat there was a switch for gas or electric backup. There doesn't seem to be one on the newer model. have wiring labeled from old thermostat. Wired correctly-Display just blinks-Have heatpump with gas backup. Any suggestions appreciated Don


... Air Conditioners

My untit is an intertherm mrac 2515 15kw electric heat and when it is turned off from the thermostate the heater coils are still on. ihave already checked and rewired all of the wires occording to the wiring diagram. what do you suggest besides changing the unit?


The heat sequencing relay is bad this is what turns the coils on when the thermostat calls for heat it turns one on at a time to keep from over amping the circuit. If you are hand with the power off disconnect the power wire to the heat sequencing re ... Intertherm Air Conditioners

I have a gmf electric motor and it has 4 wires .. blue brown black and yellow/green .. is this a 3 phase motor and if not how would it be wired into a single phase circut?


No it is a single phase motor the different wire colors are the different speeds brown would be common and then black is high, yellow medium and blue low and green is ground. ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific