R22 freon Waht does Heat pump uses more freone on heating cycle or cooling cycle? If on cooling cycle whay? and if on heating cycle Whay? Thank you! Abe


Answers :

It uses the exact same amount of freon on both cycles...it just inverts a vale which changes the condenser to an evaporator int eh winter for heat and changes the condenser back to a condenser for AC in the summer. However it does so with the same amount of freon.
Thank you ...the Fang

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

R22 freon Waht does Heat pump uses more freone on heating cycle or cooling cycle? If on cooling cycle whay? and if on heating cycle Whay? Thank you! Abe


It uses the exact same amount of freon on both cycles...it just inverts a vale which changes the condenser to an evaporator int eh winter for heat and changes the condenser back to a condenser for AC in the summer. However it does so with the same am ... Air Conditioners

What kind of freon would i need for a goodman cplt24-1a heat pump ? has not cooled the houuse for 2 years now, thought it may have been the compressor as the heating was not working either. But i was told it may just need freon. And any idea on how much this would cost ? I am in canada but all help would be appreciated . THANKS


R22 but it does not use it it is circulated in a closed loop, if the fan outside is running you may have to pull the brown wire at the split capacitor to see if the compressor is running. Also it is really important that the filters are changed and t ... Goodman CPLT24-1 13 Air Conditioner

Wont cool!! We have 2 LG 2ton heat pump outdoor systems, but I believe the remotes are cool only. The 01 system cools perfect, but the 02 outdoor fan runs half as fast as the 01 system and the compressor keeps cycling on and off, and they are hot enough to burn you. I am totaly stumped on what the proble could be.... We swaped just about everything between the 2 systems and still the 01 frezzes you out while the 02 will not cool at all.. Any kind of seguestions wold be much appreciated, Thanks i


U may have a heat pump thats not reversing into cooling. Any number of items can cause this. I would start with the reversing valve coil assuming its a heat pump. If your not acquainted with a reversing valve it is a 4 pipe (1 on one end and 3 on the ... LG LM-2430H2L 24000 BTU Heat and Cool Dual Zone Mini Split Air Conditioner

Heating problem hello! My air conditioner stopped to heat. (there is a around 8 degrees C, outside and 16 degrees inside). It worked just fine, and now, when I switched to heating mode, there was nothing. the defrost LED ond the inside unit is switched on, but air is not comming from the unit. Cooling mode works fine. If you could please help me finding the solution for my problem. Thanks in advance. RAdan GE AIR CONDITIONER SPLIT SYSTEM WON'T WORK ON HEAT CYCLE Seems to work ok doing eve


Hi Radan, Did you get this problem solved? We have an Electrolux Kelvinator Split System and ours is doing exactly the same thing. I am struggling to find a solulution. Would be great if you can offer any advice.\015\012\015\012Thanks Nic ... Air Conditioners

This is a heating and cooling through the wall heat pump. It works normally when heating is selected - the heat pump runs and both speeds of the fan blow warm air. But nothing runs when cooling is selected. In other words the unit works normally when "High Heat" or "Low Heat" is selected but nothing runs when "High Cool", "Low Cool" or "Fan Only" is selected. The position of the Fan Cycle Switch has no effect - behavior of the unit is the same in both positions of the Fan Cycle Switch.


You have a bad board or bad switch. I would say board. You can have service tech check this out. There is only so far you can go without knowledge of Controls ad electricity. Russ ... Air Conditioners

Hi I have a goodman MSG-18HWN1 heating and cooling mini-split unit. The unit keeps going on and off on a cycle of about 5 minutes. 5 minute, unit not started, unit starts for about 5 minutes, stops for 5 and so on. Is that a normal behaviour ? It is a bit annoying. Thanks


Due to abnormal temp of out door.Check outdoor fan motor and compressor and also sensor.Fan motor not working- rectify/replace fan capacitor.Sensor defective-Replace itCompressor high amps-Replace running capacitor.Sensor misp ... Air Conditioners

I bought a programable thermostat and ,to install it, I neet to know what type of system I have: single stage heat and cool; multistage heat and cool; heat pump with backup heat; heat pump without backup heat; heat only; cool only. These are all the options. Thanks.


IT'S COOL ONLY MODEL.. ... Carrier 38CKC060 Air Conditioner

I have 2 heil heat punps (manufactured 1989), a 3T for the lower level and a 2.5T for the upper level. The 3T unit functions normal. The upper unit functions normal if each spring, when switching from heat to cooling, the technician adds 4 pounds of freon to cool properly. In the fall the tech must draw out 4 pounds of freon for this unit to heat properly. The outside and attic units are a matched set and the expansion value in the attic unit has been replaced. There's no leaks and several


Hi,\015\012\015\012To properly trouble shoot this there is much more information needed....\015\012\015\012The exact model numbers of the indoor and outdoor units...\015\012The line set sizes and the lentgh of the line s ... GE AJCH10ACB Built-In Room Air Cool Unit

Honeywell thermostat T8400c started flashing, heat/cool was off. Display flashes all icons (heat and cooling icons, temperatures, everything) and on the oppposite flash, the setpoint is displayed. The fan comes on when turned to ''ON'' but heat or cool does not when in ''auto''. The compressor can be turned on outside at the switch, but appears to have no freon. Heating & cooling worked within 2 weeks prior to this issue. Any help would be greatly appreciated.


Based on the simplicity of this particular t-stat, I really think that it is bad and needs to be replaced. They do not make this particular model anymore. I have included a link to the operators manual for the stat. Good luck!\015\012\ ... Air Conditioners

My intertherm heat pump has freon but will not heat is it posible that the reversing valve is stuck in the middle and will not let it heat if so where can i get a new one. My heat pump cools good and when I switch to heat the lines to the coil inside are very hot but coil is not. Is my coil stopped up and if it is how is it cooling?


You can't replace a reversing valve (must remove ALL refrigerant first), unless you are EPA certified and have the equipment to recover the refrigerant and to braze the old valve out and the new one in. That said, it's probably an electrical problem ... Air Conditioners

Amana PTH153B35AK This unit is less than 30 days old, heats fine cools fine, but when i have it in heat mode,set @ 70 or so, as soon as the room heats up, the unit will cycle into a/c mode and blow super cold air for about 5 minutes than return to heating. Sometimes it will reach the desired temp. and turn off like it is supposed to do, but for the most part it just cycles back and forth from hot to cold...Amana has the worse help/service i have ever seen, i was on the phone for an hour,everybod


This often happens if the unit is oversized or to close to a wall or object. ... Amana PTC153B35AK Air Conditioner

My house have a gas heating and electric cooling system. When I turned the cooling on the outside fun started but the cooling system inside house does nto start. I tried heating system it dose not start also. Please advise what might be the problem. Thanks


If the fan outside is running then feel the compressor outside or listen to it if you can notice that the compressor is running the same time the outside fan is running also.it could be that the compressor is not running.but i ... Air Conditioners

Heat pump shut off 1 to 2 minutes, service yesterday for same problem told low on freon. Added freon, worked fine until it went thorugh first defrost, now back to same thing. Tech says compressor not getting signal from thermostat. After resetting T-stat, unit came on. Unit works on cooling and Aux heat, but no heat pump.


It is possible that you have one or a combination of a few different problems here.If your heat pump will not come on but the air handler works, the first thing you want to check is that the circuit breaker and disconnect for the heat pum ... Carrier Air Conditioners

After a cooling cycle, when the thermostat call for more cooling, it take up to 5 minutes after the air handler starts for the compressor motor to restart. The top fan operates on the outside unit, but since the house is not circulating cold air, only the room tep air the house heats up about 3 degrees before the compressor comes back on and cool air begins to come from the ducts. Yes. I know there is a safety feature to protect the compressor, but can the cycle be shortened?


No, this cycle cannot be shortened due to the simple fact that this feature is in place to protect your system. Even if it could be, I wouldn't recommend it.Mat ... Coleman Air Conditioners

Honeywell Wireless System THM5320R Wireless system and thermostat startup ok. The issue I am having is that; when the thermostat is in cooling mode and the unit starts the reversing valve is in the wrong position and the system is heating. There is more than 3 degrees between the heat and cool settings on the thermostat. Thank you. mschaeff bryanshvac bryanshvac Rank: Master Rating: 75.00% , 2 votes make sure you thermostat o terminal is used fir reversing valve in cooling, or b termin


How old is the existing system? i do ac in florida and usually if its not the wiring, an old systems rev. valve may stick. a firm tap on the valve may solve your problem. ... Air Conditioners

I have a split system sanyo heat pump model # kmh0922. The evap. fan will not come on when called for in fan mode. When i put it to heat the indoor fan will also not come on. The compressor runs but the reversing valve seems to stay in the cooling mode. When it is put into cooling the indoor fan goes off after 15 seconds and will not come back on. (The condenser fan and compressor seem to act normal in cooling.) Any ideas as to what the problem could be? Thank you, Mike


Sounds like the blowers capacitor has gone bad ... Sanyo Air Conditioners

Normal in cool cycle, very high pressure in heat cycle


Expansion valve on the condensor or possibly overcharged with refrigerant? ... Goodman Air Conditioners

My heating and cooling unit heats fine in the winter but when it gets very cold outside my unit gets covered with frost and puts out cool air can you tell me what the problem maybe. Thanks


... Air Conditioners

Hi there I have an lg reverse cycle aircon model LWC122RH-2 and the heating seems to work fine on it at however when I try and put the cool mode on it desn't seem to get very cold and the cool light does not come on also the defrost light doesn't come on but the heat light and the fan light and timer lights all work and come on ...please help


... LG Heat cool Window Air Conditioner

I just had a flex multi split ductless system installed. when it comes to heating and cooling there seems to be about a 4 degree range between when the heating and cooling comes on and off. also,the thermostats will only read in two degree increments is this normal? Thank you,


Read your maunual. It might be normal. A 4 degree split in your set back heateing control is about normal. It is that way so you can turn your unit on and never really need to touch it again. When the temp goes up, cooling goes on. When the temp ... LG Air Conditioners

Honeywell Wireless System THM5320R Wireless system and thermostat startup ok. The issue I am having is that; when the thermostat is in cooling mode and the unit starts the reversing valve is in the wrong position and the system is heating. There is more than 3 degrees between the heat and cool settings on the thermostat. Thank you. mschaeffer


Make sure you thermostat o terminal is used fir reversing valve in cooling, or b terminal is used if unit is a Rheem or Rudd, reversing valve at condensing unit may have bad connection. ... Air Conditioners

Hi guys, I try to solve this problem i have with my AC unit American Standard YCC048F. Short: The heating and cooling are ok, the only problem is the fan doesn't turn off even if heat or cool turns off. Some times even if i put the thermostat is on off the fan starts running. I try to find a relay for the fan but i don't know what can be the problem. Please help, for now i am switching on/off the unit to have it run. Thank you. Costi


If the unit has printed circuit board the relay maybe in it which has probably welded contacts, must change the pcb then or try tapping it, it might help or even, try off and on power at circuit breaker it migt reset the pcb. ... Air Conditioners

My Amana A/C is almost five years old. It is not cycling in the heat of the afternoon. I live in Las Vegas, NV. I recently had the expansion valve replaced, but this did not fix the problem. The original problem was it was not cooling, but now the problem is it is not cycling. It will run all afternoon until the temp outside cools. I also need to know if this valve is still under warranty. I have a 13 seer, 3.5 ton. I am sorry I do not have the model number. It was installed on 9-8-2004.


If 5 years on parts, you still have until Sept. 9, this year, to avail. Besides, if the problem is with the compressor, its a lifetime warranty you said. :)The best thing to do is avail your warranty from an authorized service center to ... Air Conditioners

Reversing valve Model: PHJ030-1A Seral: 9705062008 The reversing valve is not reversing to heat. I found a small hole at the condenser coil, with oil residue around the "U" shape joint. When the heat stop, the condenser froze up. I think the a/c part will continue to cool with low pressure. Could low freon keep the reversing valve from switching. Reversing valve need more pressure to work. I check coil, the ohms is 17.6, and I do have 24 volts going to the coil, but I did not check it in cool fo


The first thing you need to do is fix the hole in the coil. It will only get worse no matter what you do. The reversing valve is controlled by the thermostat, then to the defrost board, as it has a timer, sensor ... Air Conditioners

No heat My 7500 zoneline will not provide heat consistantly. I can unpplug the main power source to the control boards and plug it back in, ,and I will then get heat. If I turn down the thermostat (80 to 70), then turn it back up, I do not get heat again, only cool blower air. Is one of my control boards bad? Thanks.


It sounds like it could be the tstat itself. Unless you use a voltage meter to take some readings it's hard to determine if it is a board. The best thing for you to do is remove the tstat from the system and manually operate it with a jumper wire t ... GE Air Conditioners