Having problems with your Air Conditioners ?

Good morning, Panasonic Ac unit model CS-PC30EKF, stops working after five minutes and the timer light starts flashing. The only way to switch back on is to switch the unit off and on again, however the problem is still happening. Please advice on problem Regards Cliff


Answers :

First the thing that's causing the thermostat to act up Could be the thermostat being bad.

The blinking does it continue for hours on end and nothing runs? If so the thermostat LOCKED OUT. Now what caused this???

I proceed with the assumption that the controls are 24vac.

Depends on how the thermostat is communicated with and how it interprets the information its getting. Could be a real in depth problem, like low refrigerant or low air flow. Both of these problems could be caused by a fan not running when it should, or shutting off when it should not or a dirty filter.

If it doesn't have a "code" telling you any information then its locked off most likely.

First lets see if we can narrow or trouble down by looking outside and inside units til the problem happens. Assuming you noted nothing to show you any place to concentrate on outside or inside (like both fans run, air filters clean, all duct dampers open... ) concentrate on eliminating the thermostat.

Most important if your system has a special thermostat, room sensor, or more than 5 wires to thermostat are used: You have something that you need a tech on because it is impossible to cover all the bases here.

To eliminate the thermostat as the source of the trouble;
1 Kill power to indoor section as this is where the thermostat gets pow from most often.
2 Make a diagram of the wire terminals and label them and put the colors down as to what colors go where. (Colors mean nothing except to the person doing the installation, troubleshooting, or wiring, so he/she wont get lost and keep things straight. On controls, color could be any color but these terminals on the thermostat can not be they have a reason to be marked.)

Now you can disconnect the r,g, w, and y wires (all of them) Usually only 4 on a simple hvac system.
Now put the wires that were on R Y and G together. Stay close to the indoor and out door units for the time limit that the problem used to have if it doesn't reoccur within the previous lime limit plus time and nothing is noted as to sound or speed or other, Id have to assume its the thermostat because you just did what the thermostat did only manually.

If this helped you trouble shoot or decide your next step please rate ma as high as you can.If you need more please post back with what you found on your tests and what changed or what you noted different.

Thank you for using Fix Ya and good luck.
Make sure filter and coils are clean. It might be going off on high temp/pressure. Airflow is a must.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Good morning, Panasonic Ac unit model CS-PC30EKF, stops working after five minutes and the timer light starts flashing. The only way to switch back on is to switch the unit off and on again, however the problem is still happening. Please advice on problem Regards Cliff


First the thing that's causing the thermostat to act up Could be the thermostat being bad. The blinking does it continue for hours on end and nothing runs? If so the thermostat LOCKED OUT. Now what caused this???I proceed wit ... Air Conditioners

Sharp Air Conditioner AC09RLCSYS isnt cooling properly. Very moderate to low cold air from unit. At one point small bits of ice came out of indoor unit when on auto cool. Unit was switched off immediately and then turned back on after a few minutes with no additional problems, however still is not cooling properly. Unit is only eight months old. First used for cooling with no problems and great cold air, then for heating during winter. Now back to cooling and not getting the cold air like p


Unit may be freezing up if blowing ice crystals. Let thaw 24hrs try again. Make sure condensation drain line is cleaned out. ... Air Conditioners

I have two Dometic roof top units both have sepreated controlls. The smaller bedroom unite will not shout off. When turned to off, when the thermostate is lowered, or when the controll is switched to furnace. Still the unite will keep running. The fan can be low or high but the unite will not shout off unless the breaker is opened. I thought the problem may be the wall mounted controll so I switched the one from the front (knowened to be good) to the back bedroom. No change. The bedroom controll


May be the relay is stuck, you will need to open the unit and see if the relay is releasing when you turn off the breaker. hope this helped tim ... Dometic Rooftop RV Air Conditioner

Have a Grand Aire Central Air and Heating unit a/heat pump...has been working fine. Switched it over to heat and nothing came on. Switched it back over to air, which was working and still nothing came on. Switched fan from ''auto'' to ''on'' and the fan will not come on. Used a screwdriver to push the contact in and everything runs (air and heat) as long as I am holding the contact in. Changed the t-stat, still the same problem. I really don't have the finances to call a pro in, any advice will


The fuse may be in line (red ) wire check control voltage if not present transformer (or fuse) needs replaced \015\012 the problem probably was caused by white wire (heat control voltage) has been wired to common not heat control ... Air Conditioners

Drainage Hi, I have the portable Maytag AC unit mentioned in this forum. I have had it for two years, and I still haven't figured out how to address this problem. The unit just shuts off. The only way to resolve this is to tip the back so water can come out of that small black tube. I assume there is a better way because it only stays on for a short while, then it turns off again and I must repeat the procedure. My friend has rigged it up so that the tube is pushed down into a bucket, and it dra


... Maytag Portable Air Conditioner M6P09S2A

Amana 90% model #GUCAO45AX30 SER# 0109143635 UNIT MAIN BURNERS LIGHT UP THEN SHUT DOWN IN A FEW SECONDS. DRAIN LINES ARE CLEAR, VENT PIPE CLEAR OF CONDENSATION. I BYPASSED T-STAT JUMPERED R-W NO HELP, INSTALLED NEW FLAME SENSOR STILL SHUTTING DOWN. UNIT HAS TWO PRESSURE SWITCHS OFF INDUCED DRAFT MOTOR, HOSES GOOD CONDITION AND TIGHT. I HAVE HAD PROBLEM WITH WATER IN 2 INCH ABS VENT PIPE, NOT SLOPING BACK TO UNIT, THIS ONE SEEMS TO BE CLEAR. SHOULD I CUT PIPE AT FURNACE AND TRY TO START ?.. MAYBE


Check to see if the flame rod tip is in the flame(like the hot junction on a thermocouple). the pressure switches are a normally closed switch and a blocked flue could cause them to open. the circuit board should run through the safety switches and c ... Amana PTC074B25AE Electric Heat Air Conditioner

I have a camper with a Dometic rooftop air conditioner. The Model No. appears to be 3310700.012. The thermostat it the type that fully shuts off the unit (compressor and fan) when the set temperature is reached. The problem I am having is that the "dead band" (time between unit shutting off and coming back on) is too long, allowing the camper to become uncomfortably warm. A. Can the band width be adjusted to cause the unit to cycle sooner. Or, better still... B. Can the thermostat switch be bypa


No both the options A and B which you gave cannot be done.yes option B is possible in some form.but in this case fan will not shut down and this will burn the fan motor and even make the fan wirings short/.so option B is also not advisable.but the pr ... Dometic Rooftop RV Air Conditioner

Haier Portable AC (Model #HPRD12XH7) won't turn on, and a red light has appeared. Also, the display shows the text STOP. The machine has been unplugged and then plugged back into the socket, and still the problem is persistent. We've only had this unit for less than three weeks, and I would like to know if it would be easier to just return it or is there some way to fix this problem?


... Haier Air Conditioners

I posted a problem a month ago about my vulcan climate control ducted gas heater where the flame igniter but the flame did not stay alight. today i replaced the identical thermocouple however the ignition (electronic) does not work i had shut off the gas near the unit and switched off power on reading the manufacturers instructions on the panel i tried switching off and on several times still does not work


Most of the time there is a down time necessary in between turning it on and off make sure you give it a few minutes after turning gas back on and make sure your thermostat is off than turn on your ignition and than after a minute or so turn on your ... Air Conditioners

I have a ruud model no. ubhc-17j11nfd and i am having a problem with my heat. when the heat does come on, the thermostat says it is on auxilary heat. the blower in the inside unit does not run. i changed the capacitor and now i get a really loud humming noise. the motor still does not spin. but when i spin the motor by hand then it seems to work fine.(the humming goes away) this happens every time when the heat goes off then back on. the only way to solve this is to keep the fan on constantly.


... Ruud UBHC Air Conditioner

I replaced my outside unit with a 3 ton goodman heat pump unit. My old unit was a 3 ton bryant and the compressor burned up in it. I left the old unit under the house since it seemed to be in good condition. the pump worked fine on ac to start off. But then you had to switch it in heat and back to ac for it to work. So the tech replaced the expansion value and put filters in both lines. I still have to switch it back to heat to get the ac to work. The tech told me that i would have to repla


You said it had rwo filers on the line. I know one is a liquid line drier. If you have one on the suction line it need to come out ASAP. The trash in the line can be removed by running in cool.pump down unit replace drier. While the unit is pumped ... Air Conditioners

There is a switch on my 1 1/2 ton Ruud furnace/Air handler that is not working properly. The unit would not turn on, even though the thermostat was working. I took the panel off of the air handler and found that a switch had been duct taped into the on position on the unit. Apparently, the tape had shifted and the switch was no longer in proper position. when i moved the switch, two green indicator lights lit up. When i turned the unit back on, the A/C worked. Clearly, there is a problem w


Helllo, this switch is called a door interlock switch. ... Air Conditioners

Installed two new 3312020 controlers wired with inst will only pick up zone1 all dip switches off on front unit exept furnice zone 2 on back unit old controlers only had one inside air temp i ordered two new ones still nothing on back unitwhy will it not inl back unit


... Dometic 3312020.000 Comfort Control Center II CCC2 Multi-Zone Kit

I have a honeywell PA404A pressure control switch on my home gas steam heating system. I'm having a problem with the switch turning off the system. It will only come back on if I turn the top screw all the way out, then back down to approx 5psi. At this point the heat will turn on but when the thermostat shuts down the system it will not turn back on when calling for heat unless I adjust the screw again. Also, the switch will only turn on the system when set at 5 on the dial on the inside. Any i


This may be caused by accumulation of sludge in the steam trap (the looped tube that connects the pressuretrol unit to the boiler). the sludge restricts the pressure from reaching the diaphragm in the pressuretrol unit. So it gets a false reading. ... Air Conditioners

My unit is 4 years old. I always turn it off when I leave for work in the am and turn it back on when I get home in the pm. Last night I turned it on at 7:30pm. When I went to the front of the house about 45 minutes later, I noticed the unit outside was trying to turn on but would immediately turn off. I checked the breakers in the garage, turned them off and back on but still had the same problem. The fan inside the house is running but unit outside will not kick on. I looked for a magic


It could be a few things.. It could be the capacitor - which the most economical to replace first..\015\012\015\012If you are not really very mechanically inclined - get a trained pro to come out.. It is very dag ... Air Conditioners

My Diamond 80 furnace burner fired up, but stays on for 1-2 minutes. Cleaning the flame sensor didn't help. Removing filter however solved the problem. Filter is quite new by the way. What could be the problem? I didn't have this problem before, with the filter in place. Is there some high thermal switch that switch off when temperature reaches certain threshold? Thanks.


Check your thermostaty setting. If it's correct, you have to replace sensor only. ... Air Conditioners

Ac problems posted by couuntrygirl on Aug 20, 2008 Report abuse The unit will not cut off when it reaches it temp. in camper. I have replaced the Thermostat, control board, and the compaster on the top. I still have the same problem. It will not cut off with the switch heat off cool you have to use the hi low switch and its all wired right. Very confusing. When you move the temp control handle on the top to a different degree it makes the fan go from high to low it will not cut off. when it reac


Sounds like the switches are in the wrong locations , rotate! Thank- you- very-much! ... Dometic Rooftop RV Air Conditioner

My heat pump will not come on in HEAT or A/C. I thought I might have a simple defrost control board problem, but still no go after replacing the board and the defrost relay. I checked the pressure switch and it is not tripped. I've checked all the circuit breakers and they, too, are all set. I've checked the outside unit using the "test" switch inside on the start relay and the unit will come on, but won't stay running on it's own. When I select HEAT, I wait the necessary five minutes for the un


Hi; Need more info. How old is the equipment,look on the outside unit data plate it will give the built date usually in the top right corner. Also heat pumps can run with a faulty defrost board. I would check for control voltage at the secondary side ... Ruud UBHC Air Conditioner

I have a goodman Air conditioning unit CKL49-1. The fan motor connects to the top lid. Recently the metal cracked and broke and the fan fell down inside. I purchassed a new lid mounted the fan back on to the lid. It doesnt seem that any major damage was caused. I put everything back together the way it was. When I turn it on it will only go on for a sec then a switch inside turns it off. When i looked at the electrical on the ac i noticed when i turn it on a little spark on a switch and the swit


Sounds like it is overloading and tripping the circuit breaker (that thing that pops up). More than likely when the fan fell down it stopped the blade from turning which caused the motor to overheat, melting the windings insulation which caused them ... Goodman CKL49AR49 Air Conditioner

A/C Problems The unit will not cut off when it reaches it temp. in camper. I have replaced the Thermostat, control board, and the compaster on the top. I still have the same problem. It will not cut off with the switch heat off cool you have to use the hi low switch and its all wired right. Very confusing. When you move the temp control handle on the top to a different degree it makes the fan go from high to low it will not cut off. when it reaches like 70 and its set on 70 the fan will go from


It's not wired right! bottom line! ... Dometic Rooftop RV Air Conditioner

I do not have a camera at this moment that i can use but i can tell you the unit is tilted and is lower on the out side. however it still not dripping towards the back for some reason it is not getting to the back of the unit its pouring out the front.


The unit probably needs taken out of the window and given a good cleaning. Slime and lint build up in the evaporator pan and on the evaporator surface itself and causes water to overflow the pan. Be very careful to cover electrical parts, controls, m ... Air Conditioners

I have a frigidaire window unit. i cannot recall the exact # of the unit. but, my problem is that the unit still cools, but the smell it emits is similar to that of a wet dog. i opened the unit and cleaned the filter, i noticed there was what appeared to be a second filter, but i did not see a way to get it out. after cleaning the filter, i turned to unit on and got the same results. i think the unit # is something like FAM187STA


Hi, you cannot take out the second filter because you are not a tech in that field. Many times when a wall or window a/c unit is installed the installer\015\012levels the unit.It should actually be lower on the outside end than the\015\012wall ... Air Conditioners

We have a Vulcan ducted heating unit model HX100, recently we have experienced problems with the unit where is it not heating the house, the unit goes on but blowing cold air. We have had a couple of technicians to repair it and still not working. One fixed the switch pressure & the other the flame sensor connection. We have been advised that we may need a new unit or repair the board. As we have an illness in the family, we would like to know whether we need to purchase a new unit as p


\015\012We had the same problem with our carrier heater 4 year or so ago. We had a technician and electrician try to resolve the problem. What the tech suggest was to replace the main component ... Air Conditioners

I found the Bryant furnace 395cav048090 calling for heat but not operational. I shut off power to the unit and switched power back on and the unit started its ignition sequence. With power on the blower starts as a result of thermostat calling for heat from the unit and after a minute goes on to second phase of ignition with exhaust blower motor initiated. During this phase gas is being brought to the burner that you can smell however burner does not ignite gas. Unit continued with this opera


If you do not see a bright light before the gas releases, your ignitor is probably out. If you disconnect, you should measure ohms from the two ignitor leads. If you do not measure any, it is open and will not work. You will usually see a mark of whi ... Bryant Air Conditioners

My unit stopped blowing cold and started blowing hot.i turned off unit looked into furnace and saw pilot was still lit.i put out gas pilot and turned unit back on and it is blowing semi cool air (like fan)but not cool as it should.checked outside ac and it is running....munual says to turn unit off for 2 hrs and if it does not do right then it is compressor.we are currently in the 2 hr process. Any help would be helpful at this point.is there a reset switch or anything I could do to troubleshoo


100 degree temps/high humidity puts an extreme load on air conditioners - but if everything is right with the AC - 'overheating is not a big problem.\015\012\015\012The first thing I would check is whether or not the compressor is running ... Weather King 10AJA4201AH Air Conditioner