Heat Pump Cycles On and Off and Air Handler Noisy

\015 Bryant heat pump cycles on and off continuously when set on heat-cycles on for 5 seconds & cycles off for 15 seconds. Outside temp 59 degrees, humidity 95%. Also happens in extreme cold weather. System keeps house at set temperature. If switch to air for 2 mins. & switch back to heat, stops cycling and works fine for a few days. Carrier air handler is now making a loud harmonic vibrating sound.\015

Answers :

I am pretty sure you have a low charge and the pressure switch is kicking it off. probably just a pound or two however the accumulater will sometimes hold more.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Heat Pump Cycles On and Off and Air Handler Noisy


I am pretty sure you have a low charge and the pressure switch is kicking it off. probably just a pound or two however the accumulater will sometimes hold more. ... Bryant 463AAC008BA Air Conditioner

I am trying to wire a Honeywell Vision pro Th8000 series thermostat onto a Weather king heat pump and air handler. The thermostat wiring has r,rc,y,c,o/b, g aux,e,y2andl terminals I understand these but the heat pump has differant color coded wires heat pump-y,b,c,r,d and the air handler w2,g,y,w1,b,odd,c,r,y I don't know witch is the reversing valve wires or what odd means. Can you help me with this?


RC & RH JUMP WITH R FROM AH & CUC/U - A/H - TR - R - R = 24VC - C - C = COMMONY - - - Y = COOLING G - G = FANB O\\B = REVERSING VALVE - HEATmake sure the ... Air Conditioners

My outdoor heat will not operate. It is a Carrier 38YRA042330, with a Carrier Thermidistat thermostat and a Carrier Air Handler 40FFKB005300. I have an H5 error code on the thermostat will I put it in Heat mode and raise the setting to call for heating. I changed the air filter on the air handler when I realized the heat pump was not operating. The air filter was pretty dirty. The system will operate in aux/emerg heat mode, with the fan in Auto or On mode, and will maintain the thermostat


You need to go oside and look for a red reset button on the unit. you tripped the high ressure switch when you let your filter get that dirty. go check on this and when your done if it still is not working then ask me more. ... Carrier Air Conditioners

I have a Trane Model TRW036C100A0 heat pump with an American Standard Model TWE036C14FBO air handler. The heat pump outside is 20 years old and on it's last legs. The air handler is only about sev


... Air Conditioners

This is a heating and cooling through the wall heat pump. It works normally when heating is selected - the heat pump runs and both speeds of the fan blow warm air. But nothing runs when cooling is selected. In other words the unit works normally when "High Heat" or "Low Heat" is selected but nothing runs when "High Cool", "Low Cool" or "Fan Only" is selected. The position of the Fan Cycle Switch has no effect - behavior of the unit is the same in both positions of the Fan Cycle Switch.


You have a bad board or bad switch. I would say board. You can have service tech check this out. There is only so far you can go without knowledge of Controls ad electricity. Russ ... Air Conditioners

I have a new Rheem heat pump. The cooling works fine but won't blow hot air in HEAT setting. I have reset the breakers for heat pump and air handler, changed filters and pulled batteries and reset the Braeburn 3000 thermostat. Still blows cold.... Any other suggestions?


If this is indeed a heat pump you rthermostat should also have a emergency heat setting does it work on that setting... a heat pump on heat wuns the outside unit and has a recersing valve that changes the refigerant flow ..is the outside runnigndurin ... Air Conditioners

The thermostat for the comfortnet communicating system for a3 ton Goodman heat pump is indicating check air handler and heat pump


... Goodman Air Conditioners

LOW VOLTAGE WIRING CONNECTIONS BETWEEN NORDYNE FT4BF-0-36KA 16 SEER 3 TON HEAT PUMP AND B4VMX36KBAH VAR 410A AIR HANDLER AND RITE TEMP 6036 THERMOSTAT. THE CONNECTIONS ON THE OUTSIDE UNIT ARE Y, R, O, C, W2IN, Y2, L, W2OUT. THE CONNECTIONS ON THE AIR HANDLER ARE Y1, W2, W1, O, Y/Y2, G, R, C. THE CONNECTIONS ON THE THERMOSTAT ARE C, B, O, W2, W1, Y1, Y2, RH, RC, G, A. ARE ANY OF THE TERMINALS ON EITHER THE AIR HANDLER OR THERMOSTAT JUMPERED TOGETHER AND IF SO WHICH ONES. I AWAIT YOUR RESP


... Air Conditioners

I have a Lennox model CB19-51-1P air handling unit with HP19-511-1P compressor heat pump unit. I just turned the heat on for the first time this season. And I am getting low heat volume. The heat pump unit is running for long periods. I am getting enough heat to maintain the 70 degrees setting with constant cycles, shutting off for short periods, running long periods. When the thermostat is turned to a cooler temperature, the unit shuts off as it should. Could you please help trouble shoot po


First thing you need to check is if the reversing valve is working you maybe running your A/C with the heat strips on depends on the t-stat your using some heat pumps will bring the strips on with a high d ... Air Conditioners

I have a goodman gsh130361 3 ton heat & air. It was installed 05/05/2008. all seemed well until cold weather, in 2009. The fan turns on and start blowing before the heat box is even warm. The heat set on 70----- when it gets 68 or 69 {in the house} the out side pump kicks in, 10 to 20 seconds later the fan turns on and blows freezing air into the house. the temperture will drop dramatically for the next 1 & 1/2 minute. The box will heat up and then all is well untill the next cycle.


The PCB unit that controls the thermostat and Coolant is malfunctioning... check that particular unit...that would help.... ... Goodman Air Conditioners

After a cooling cycle, when the thermostat call for more cooling, it take up to 5 minutes after the air handler starts for the compressor motor to restart. The top fan operates on the outside unit, but since the house is not circulating cold air, only the room tep air the house heats up about 3 degrees before the compressor comes back on and cool air begins to come from the ducts. Yes. I know there is a safety feature to protect the compressor, but can the cycle be shortened?


No, this cycle cannot be shortened due to the simple fact that this feature is in place to protect your system. Even if it could be, I wouldn't recommend it.Mat ... Coleman Air Conditioners

HE heat pump won't talk with old air handler?


The fact is, the air handler supplies the voltage, blower, and electric heat. In order for the heat pump to work correctly, the wiring from the thermostat and heat pump need to be hooked up right to the air handler. The thermostat is what tells which ... Goodman Air Conditioners

I have a ruud achiever 10 model UPKA-018JAZ with air handler in attic. Was wondering if this is a single stage heat pump or a multi stage? trying to connect new thermostat, air conditioner is working but when turn on heat only the fan comes on and the compressor outside never comes on to warm..but compressor does come on when switch to cool..


This may be as simple switching the thermostat to electric, under the cover is a gas/electric dip switch. Hope that helps. ... Ruud Matching Split Air Conditioner

UHQA-1010B Air handler with heat pump. Unit heats up nicely but once area temp. is met, heater de-energizes but blower continues to run. Opened unit up and blew out with compressed air, and tapped on what looked like a relay but no change. Termostat switch for blower is set to auto. Any answers would help. Also a wiring scematic would help me. Thanks


... Ruud Air Conditioners

Am having a Tappan Split system heat pump installed. Proposal was for a 14 SEER system including a FTBD042K heat pump and a BCS2M48C variable speed air handler. However Actual equipment installed is FT4BD-042K and B5BM-X49K-C. The Yellow Energyguide shows SEER 13.0 & HSPF 8.0 Am I getting ripped off, with an installation of a cheaper less effecient system?????


I dont think so that variable speed air handler is a nightmare when(not if) that motor goes bad its 700.00 to 900.00 the regular 3 speed one your getting 125.00 and it will last 10 to 15 years ....... if you realy want fun install a 17 seer system ... Air Conditioners

I have a 18000btu LG mini split heat pump installed about 1 year ago in vacation home. In heat mode the unit cycles on and off when room temp is within 2-3 degrees of set point. Cycle on time varies between 35 to 60 seconds (sometimes more). The off time is 2-3 minutes. During this time, I check inside temp with accurate digital themometer mounted at the air intake of the unit and the temp does not change, assume because unit does not run long enough. When I put temp set point more than 3 d


Hello.I think they are on to something with shortcycling on temp sensor.I think it should be sampling the return air instead of (inside coils ?).A 2*f dead band use to be built in (factory installed) to thermostats to prevent on/off, but ... LG LS-L1210CL Mini Split Air Conditioner

After installing an air handler for a heat pump system, the condensation started. the air handler sets in an outside, unconditioned space. it is well insulated,and all connections sealed with mastic. it is a two zone system with a bypass in the mech room. what is a fix for this system?


Hi, on the refrigerant lines that are now condensateing, all you can do with them that are exposed are to wrap them with the black insulation made for this and make sure you have your condensate line connected to the air handler at the evaporator coi ... Air Conditioners

I have a Jantrol heat pump & A/C. It is approximately 10 years old. For the last 3 summers the compressor unit will freeze when the air handler fans fails to come on. It worked fine for 2 weeks this year before it happened. I've be able to thaw it out and restart the unit and it works from days to weeks before this occurs again. The last time it happen, I had a problem getting the air handler fan to come back on, but it did eventually. I've been thinking it may be the sequencer, but now I'm wond


Hi,\015\012\015\012If you can safely check the supply to the motor when it should be on, then this is the best method to check it.\015\012\015\012Check the fan turns very freely - oil the bearings if it doesn't.\015\012 ... Goodman Air Conditioners

1997 Amana 2 or 2.5 ton heat pump, 13 seer - air handler only blows 4-5 min


Do you have a totaline t-stat. they and some other brands have a fan recirculation setting in the installers menu. \015\012\015\012this is assuming that this happens in addition to the heating or cooling normally ... Amana PTH123B25AJ Heat Pump Air Conditioner

Compatability of a R22 air handler and a R410a heat pump


1. The units should match up without a problem.\015\0122. You will need a 40 or 50 amp breaker for the A/H and 5 KW heat strip. You will probably need a 20 or 25 Amp for the condensing unit. I would check the FLA (full load amps) rating on bot ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

My heat pump compressor seems to be locked up. Do I have to replace the air handler as well


... Air Conditioners

New Ruud 16 seer central air and heat pump - very noisy


A few things to check\015\0121) Is the unit mounted on metal brackets attatched to\015\012the house, is so I would probably put rubber pads\015\012between the unit and the brackets to absorb the\015\012vibration.\015\012 ... Ruud Matching Split Air Conditioner

Air Conditioning I have a ruud system with the air conditioner outside and the air handler upstairs in the attic. My systems appears to be running, and I can feel cold air at the vents, but I can barely feel it. Like there is no flow. The fan outside is running and the unit in the attic is running. I have no clue what the problem is. The large coil coming from the heat pump outside is cold and has condensation on it. It also seems to have a little ice. It has been extremely hot here in Ge


Open the access panel on the air handler in the attic and take a look at the evaporator coil. If you have no airflow, and you just changed the air filter, then you probably have a buildup of airborne crud on the coil that's blocking airflow. \015\01 ... Ruud UAKA030 Air Conditioner

Hi: Last week, a contractor installed the above-mentioned new 16 seer heat pump, an air handler and a heat kit. Our house has 3 levels, each about 800 square fit. Initially the house would not heat above 56 degrees. Therefore the contractor drained 2 oz of Puron gas from the line, then decided to put 0.5 oz of Puron gas back in. The temperature is now rising to the desired temperature. However, it seems to be rising rather slowly, i.e. 1 degree per hour while utilizing the auxiliary heat (w


That is worrysome about putting refrigerant in hap hazzardly... There is a math style process involving pressures and temperatures in two locations that dictate how much ref. goes in. Anything else shows clueless installer. Too much or too little ref ... Air Conditioners

Ruud heat pump leaking water at air handler


... Ruud Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1555 seconds