Need original refrigerant factory charge specs

\015 I am developing an inventory of my government agency's greenhouse gas emissions. I need to locate the original specs for a Whirpool thru-the-wall air conditioner, model ADF-W1240, used to cool a shelter enclosing air quality monitoring equipment. \015\012\015\012I need to know the original type, and amount of refrigerant that I assume was used by the factory to charge the unit.\015\012\015

Answers :

It is most likely R22, And holds less than 3 lbs. Thank you for using Fix ya and please rate me higher than global warming.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Need original refrigerant factory charge specs


It is most likely R22, And holds less than 3 lbs. Thank you for using Fix ya and please rate me higher than global warming. ... Air Conditioners

Need original blower motor and cap. specs for Ruud Deluxe 90+


The motor specs can change from time to time depending on what the manufacturer has in mind. If it has locked up check first and make sure the squirrel cage fan has not moved and is binding on the housing. If it is clear to tu ... Ruud UBHC Air Conditioner

Hi. I have a Sankyo SD-508 airconditioning compressor that runs the refrigeration on my boat. It doesn't hold the refrigerant charge for very long (2mths or so) and I understand the seals may need replacing. Does that sound like a likely diagnosis/solution, and if so, how do I go about doing it? Can anyone point me to a link to a repair manual for it? Thanks!


Hi, yes it is a possible that you may have leaking seals . I have a link for you to check out and it may be of some help with the Sankyo SD-508 compressor.I have repaired Refrigeration systems for a lot of years.What I would do is locate/pinpoint lea ... Air Conditioners

Evaporator coil needs to be replace again. Installed w new manufactured home; 09/2005. Replaced 05/30/08. Needs to be replaced again 09/17/09. All due to leaks. Freon was added. Currently has small leak; estimated life is 5 to 90 days. Warranty for part good til 09/2010, but local original installer Weirich Air refuse to replace free of labor charge of Aprox $650.00. Nor will company Nordyne pay for labor. I also feel that Weirich/Nordyne should reinburse me for previous $809.74 labor & service


The manufacture is only required to supply the part free of charge thru its warranty period. the installing company probably would only give a 1year labor warranty and honor the pparts thru the manufacture for 5 years but unless you paid additinal fo ... Intertherm P3RA-042K Air Conditioner

Factory Refrigerant Charge Intertherm Heat Pump Mod# T3RC-042k. Serial# T3R9804-17337


... Air Conditioners

The blower of my carrier 1.5 hp unit is very weak i already had it cleaned and freon charged the repair man said that the capacitor needs to be replace for it is responsible for the blowers. How true is this? If so where can I buy original capacitor parts for my unit.


You will need to go to a appliance store,to order the part,and yes it is either the capacitor,or the fan can be bad also, ... Air Conditioners

I have a 1985 Emerson Quiet Kool model 19LD4E window air conditioner, and I need a replacement filter, mine is the original factory filter and has crumbled from age.


You may have to buy a cut to size filter from a hardware store ... Emerson Quiet Kool 10GV13 Air Conditioner

I have an amana air command furnace/air conditioner. model ev4 gtc, serial number 569162. it is 25 years old, original furnace when we had home built. it had been working fine, on air conditioner setting. then it stopped working completely. i had this problem a few months ago, called a service person, who spent 5 minutes, told me it was a switch that needs reset if doors are off the unit for a certain period of time and charged me $68. i have tried to look at the layout of the furnace, but what


Hi,it is just a suggestion, don't you think it will be nice for you too get a new one to save you all the stress of repairing?. 25 years is good, but it can be better if you try a new one and there will be newer models which great future ... Amana Air Conditioners

Can i charge an Emerson quite kool AC with refrigerant by myself?


No most if not all small ac appliances have no charging ports installed. ... Air Conditioners

Honeywell t8601d showing a square symbol error - in past this has indicated low refrigerant. Tech came out, said need to replace thermostat, as compressor would not start, but if manually connected wires, compressor would start. So, had thermostat replaced. Tech then said need refrigerant. Did the t8601d actually need to be replaced?


There is a sensor that shuts the compressor down when the freon (refrigerant) is low. The tech probably "shorted" out this sensor. If the unit went on when he did this, the charge is low. ... Honeywell Air Conditioners

I have an AMCOR AMB 12000E portable air conditioner. I acan't seem to find any info on this model and have lost the instructions that came with it. Basically i need a Drainage pipe that fits onto the back of the machine (right at the very bottom). A label on the back says i would need a pipe (ref OD 18.0mm) to extend the drainage by fitting on to the original pipe BUT i need the original (with fittings). PLEASE HELP, any ideas where i might get this pipe Thanks Phil


... Air Conditioners

Need charging instructions for the system


What make and model unit? ... Air Conditioners

1989 RUDD ACHIEVER 9 AIR CONDITIONING UNIT MODEL UAFD-030JAS need specs for run capicitor


... Air Conditioners

Need to charge unit


Look at the data plate on the condenser and it will give you the factory charge that was put in unit when it was built. You will need to do superheat and sub cooling to make sure the charge is correct if it's a newer system. You might want to call a ... Air Conditioners

Does the orifice, which needs to be installed in the inside unit of an a/c for a house, come with the outside condenser? I had an a/c system installed and an orifice was never installed. the original company says that they only installed the inside unit, and dropped off the outside unit, and we had a different company install that. The original company says that the orifice comes with the outside unit and then needs to be installed inside. Is this true? ( not sure if i picked the correct produ


The orifice is the metering device inside the evaporator coil and comes installed from the factory in the coil itself. Some condensers do come with orifices taped to the side of the unit, but they only do that to ensure you have the right size orific ... Goodman CKL60AR60 Air Conditioner

Ac won't go down past 78 F while operating the presures are 15/ 150 psi. I think it needs charge. But how much charge what pressure does the low side need to be at?


15/150 is definitely incorrect, it's far too low.There is no 1 temp, pressure to go by, the 40F coil is design condition with a 80F indoor and a 95F outdoor @ 50% humidity.The more accurate ballpark method is actual ambient ... Carrier 38CKC036 Air Conditioner

I only need natural gas in the winter to run my furnace. I have electric stove and water heater to try and save money. Even though I use no gas, The Gas Company charges fees that amount to approximately $30.00/Month. Before DeRegulation AGL didn't charge excessive monthly charges per month to maintain service. If I cancel service, I have cancellation fees and then in November when I sign up with another server, I have AGL hookup charges and charges by the Server to start Service. All Gas C


Vote for a democrat ... Air Conditioners

1989 RUDD ACHIEVER 9 AIR CONDITIONING UNIT MODEL UAFD-030JAS need specs for run capicitor


... Air Conditioners

I need to know what are the specs for (BDP Co.) Carrier Corp. Model 5410 1024, it is an old High Efficiency Heat Pump; maybe from the early 80's, I need to replace it and need to buy one of the same capacity


2 ton ... Air Conditioners

I have a Trane XE1200 condensor for which I bought a replacement fan motor, same specs as the original G.E. motor. The original G.E. motor was wired to a dual capacitor, which is also wired to the compressor. The original G.E. motor had 4 wires, one of which was not hooked up. The replacement motor is an A.O. Smith model OAM10088 with 3 leads. Smith sent me a new 2-pole capacitor for the new motor. How do I wire it correctly?


OK, locate the terminals on the capacitor marked "HERM"(Compressor lead), "FAN", and "COM".(common)\015\012\015\012HERM and COM remian as they are.\015\012\015\012The wire going to "FAN" (usually brown) will be placed on eithe ... Air Conditioners

How much refrigerant is needed for 19 feet long copper tubing


Hello I would add 15oz. ... Air Conditioners

I have purchased a freestanding pellet (biomass) stove and am looking for an installer. However, I also need to convince the Dayton building inspector that it needs to be installed in accordance with ASTM E1509 and UL 1482 and follow NFPA 211 for chimneys, fireplaces, vents and solid burning appliances. He is insisting it is a factory built fireplace and must meet UL 127, and also insists that the exhaust be 10 feet from my property line, as it will belch smoke. I know different. Can anyone help


Call 1-800-total chimney or 203-874-6772 ... Dayton Air Conditioners

Charging refrigerator with r134 refrigerator just keeps clicking nothing gets cold ice melted


Hi,The compressor is bad....As the weather is getting warmer for many people their ... Matsushita DD73C14GAU6 1/4 HP R134 Compressor 115V/6Compressor

What should the high pressure line read to be fully charged on my RUUD UAKA-042 a/c unit? The specs on the unit has a design pressure of 300 PSI on the high pressure line and 150 PSI on the low pressure line. Is that the operating pressure for the high pressure charge or the maximum value that the system can with stand before rupturing a line or component?


That is a desing pressure not an operation pressure. opperating pressuers will vary with load so pressure alone will not tell you if you have the proper charge. the proper method is with superheat or subcooling, depending on the type of metering devi ... Ruud UAKA042 Air Conditioner

What problems could arise with a 5 ton air conditioner if the original refrigerant line is 3/4 instead of 7/8? The 5 ton unit replaced a 3 ton with keeping the original 3/4 line.


The 3/4 refrigerant line is low pressure and 7/8 refrigerant line is high pressure.If the line is not the same then the pressure of the refrigerant will be low then required and compressor will work as per 7/8 so it will get over heated and shu ... Goodman Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific