Fan on outside unit will not start on its own.

\015 After starting it manually, ( turning it) it will only run for a short time, then it stops.\015

Answers :

Either your fan motor or capacitor is bad. The capacitor provides the motor with a phase imbalance to start it spinning. If it is shutting off this is because the motor is over amping and getting hot. You can try replacing just the capacitor to see if this corrects the problem but most likely the motor is bad by this point. When you replace the motor, replace the capacitor as well!!!

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

The outside unit is no0t able to start the fan spinning on its own. I have been able to manually engage the outside fan by turning the unit off, turning it on, and then manually spinning the fan when it starts up. The unit will then engage the fan and runs fine until the next cycle when it cannot start the fan on its own again. Can you tell me what part needs to be replaced and about how much it will cost?


Hi!!\015\012\015\012The part you need is called STARTING CAPACITOR and it is located in the same compartment where the electrical connectors are in the outside unit. MAKE SURE THE POWER BREAKER IS OFF before opening the compartment. and befor ... Air Conditioners

I have a 1993 Model SRHF48U01A (The 0 might be a O (zero) When the thermostat calls for cooling, the inside unit (fan) starts up and continues to run but the outside unit wants to start (it comes on for a second and then trips the breaker that is located behind the outside unit. I can turn the breakers off that are inside the house and let them stay off for a short time and then reset the outside breaker and then turn the inside breakers on and the unit starts and continues to run until the te


Well the trouble is surely at the compressor side. Dont know what kind of repair man you invited. He should have atleast diagnosed the problem. Following can be the causes\015\012\015\0121. Capacitor is slightly faulty (As you said). If t ... Amana Air Conditioners

My unit is running but not blowing cool air. I went outside and the condenor fan was not moving. Took a stick and shoved a blade and the fan started moving but the air is still not cool inside. I did notice the air coming through the unit outside after fan was blowing was cooler than my 2nd a/c unit that was working fine. I wondered if the entire unit was frozen. I turned off unit at thermostat and figured I would see what happens tomorrow


Sometimes on new units it is common for the fan to not start until you give it a push. Did you happen to hear if the compressor was operating? If the unit was froze-up the Insulated Suction line would also be iced over as well. If it wasn`t it is mor ... Carrier 38CKC024 Air Conditioner

I have a 561c central air unit. I just replaced the fan motor and capacitor 6 days ago. The unit ran great for just that long now the fan won't come on and the outside unit is hot to the touch, I can assist the fan and it starts and runs great until it reaches the thermostat temp. When it turns off it won't come back on. Is it the start relay switch?


Sounds like you need another capacitor since it will run if you turn it by hand to get it started. If you have a clamp on ammeter check the current draw on the fan motor. ... Air Conditioners

When calling for cold air, the fan in the cooling unit hums, but does not spin. With a nudge, the fan does spin. Looks to be smooth and normal speed. However ambient outside air 80 degrees. the air through the register is 72 degrees. Is there a switch that will not allow the fan to start on its own if the coolant is too low? Do I have two problems, fan starting AND insufficient cooling? Unit worked well the last two days.


Sounds like start capacator possibly bad ... Air Conditioners

Sometimes, when the inside blower shuts down, the outside compressor and fan motor continue to run for some time. Other times, when the inside fan motor is running, the outside fan and compressor motors are not ... if I press the outside reset button, it starts up When both inside fan motor and outside fan and compressor motors are running, it works fine ... warm air blows out of registers. Other than that problem, both units work great!


Sounds like you have a dirty condenser. You are going to need to disconnect the power at the outside unit on the wall by pulling the fuse block out. Take a good look at the louvered covers that are attached to the outside of the unit. Remove the scr ... Ruud UAKA060 Air Conditioner

I have an American Standard Heat pump. The unit is one piece is is outside. The problem that I have is that sometimes when the unit kicks on cool, the fan motor will not start. The compressor will run, but quickly freezes up. I can put unit in off and wait for thaw and then put back in cool mode and fan will start. Any ideas?


Definitely a low voltage problem then i would look for the obvious like loose connections good luck you might have to call a tech ... Goodman CLQ36AR49 Air Conditioner

I turn on the Central A/C unit with the thermostat. The attic fan unit goes on and the system cools the house. When the system shuts down the fan unit shuts off but the outside compressor keeps running. The only way the outside compressor goes now off is when I flip the 240 switch on the main box. This just started. Is it a thermostat problem? Thanks.


Could be a thermostat problem but even more likely the contactor on the unit outside is stuck. In order to change this part you will have to get in to the outdoor unit. The contactor is the automatic switch that the thermostat energizes when the t ... Air Conditioners

Contactor not engaging to start condenser unit . When setting the thermnostat, i hear the click from the unit starting inside the house. Fans start and air starts blowing inside the house, but the condenser unit never starts. I tryed pushing the contactor by hand and then everything works find (cool house) as long as i keep the contactor pushed manually. Seems alike the 24 V (coil) bobine in the contactor is not been energize. When I tried the 24 V outside with a 24 V surce it worked fine. Thank


I would replace the contactor if you are getting 24 volts to the contactor and it isn't engaging therefore the magneto on the contactor is out and the contactor will need replacement. If you don't have 24 volts at the contactor then the transformer ... Air Conditioners

My compressor unit outside runs and cools Freon but the inside blower has a problem running. the model # is 2TEE3F31A1000AA. The fan control, in fan run control mode, shows a bright green for the fan LED and the CFM selection LED varies with the rotational speed of the fan. The motor tries to start showing , initially, a jerky back & forth movement. It squeaks some and may, or may not, start rotating. If it starts the CFM LED goes bright/on no flicker and the motor runs briefly (5 seconds) then


Hi, from what you have told me, you are loosing the bearings in this blower motor along with windings. This motor is rubbing the blower housing, tight when you turn it, and when it jerks when it tries to start tells me that you have burned or very we ... Air Conditioners

Fan make a flapping noise when turning . we cleaned the unit inside the house and out. the unit started back cooling for about 1 hour, then the motor outside got hot and the fan started making a noise like a flapping sound


CHECK FREON LEVEL, CAPECITOR FIRST. PUT WD40 ALONG THE SHAFR OF FAN AND LET IT SIT FOR A WHILE. THIS WILL REMOVE RUST. ... Coleman Mach 15 Air Conditioner

I have a goodman 2,5 ton outside unit, i cant get the compressor to start even with replacing the start capacitor and using a super start on the compressor side of the capacitor? normally i wouldnt have a problem with this kind of repair but im getting power feed back through the cooling fan motor even with it unhooked from the start/run capacitor enough to start the fan slowly. i havent seen this before


Check to make sure you have 220 on both sides of contactors, double check wiring at capacitor. you can also check continuity between all three post at compressor , make sure power is off and wires are disconected, if you do not get continuity between ... Goodman CLQ36AR49 Air Conditioner

My A/C outside will not run, inside a fan is blowing air (a little cooler than the 82 degrees it is in here, but not cold). Unlike all the other posts I've read, my unit outside is not making any noise. I makes a click when I turn it on at the termostat 1 time and then nothing. All this started yesterday sometime, after the remains of TS Fay left us. Help. I tried the breaker thing and resetting the 240v box thing outside at the unit. Help.


I am not an a/c expert but mine did this one time and it was the transformer I think it is called pull the panel off and look for wires burnt at connections also. BE sure you cut power off before doing this ... Carrier 38CKC042 Air Conditioner

Model(MC42B-1A) The unit stoped working. Now it will not come on. There is 240v at the outside unit. When the contactor is pushed in manualy it starts and runs untill released. Filters are new, thermostat is set below room temp. Settings are on cool, fan(auto). Tried to switch fan to manual and it did not come on. Swithced it over to heat and it still did not come on. All breakers are good. I am at a loss. Why will my unit not come on and run.


Hello. It appears that your thermostat is bad. Change it and you should be up and running again. J. ... Air Conditioners

I have a goodman gsc13 ac unit about 4 year old. When the temp gets around 90 or above outside the fan on the unit starts but the compressor does not. I had service check it out but that day they were here it was in the 80's and it worked fine. I replace the thermostat to make sure that wasn't the problem. Interesting if I turn the unit off at the thermostat and wait 15 minutes and turn it back on it will run fine. But the next time it tries to turn on automaitcally it will just be the fan o


The hum you hear is the 24v transformer which is powered form the air handler inside have you tried a hard start kit or had cap checked ... Air Conditioners

Outside unit not starting up motor & everything very hot WAS some noise like trying to start INSIDE FANS OK NO COOLING HELP CARRIER O48 UNIT


... Carrier 38CKC048 Air Conditioner

I have a Carrier 38CKS and want to do general maintenance, oiling etc. on my unit. Last week when I was outside, the unit started up....It made an awful squealing sound for a moment before the fan started rotating. We have not heard the sound since then. Thank you for your advise.


Sounds like your fan motor is going out keep an eye on it it could just have been the first start of the season. The unit does sit there all winter not moving. If this continues replace fan motor and capacitor. If this helps please rate me and do a t ... Air Conditioners

My ruud serial number 5427 M1496 07992 Model UAKA-024 Jaz Is not blowing cold air. I started the unit inside the house then went outside to see if the fan is working on the outside unit and it is not Can you tell me what the problem is and how i can fix it myself? Rick


1) Replace both fuses if there are any out by the unit *also make sure the breakers are not tripped. there will be two2) if you get the unit running inspect the outdoor coil under the outside fins to see if the coil is sto ... Ruud UAPA024 Air Conditioner

Inside fan turns on when outside unit is in defrost mode when heat is selected. This causes it to blow cold air for about 10 to 15 minutes prior to the outside fan starting.


The inside fan will run while the unit is in defrost. The electric heat strips should kick on to help prevent you from feeling this cold air. When the unit is in defrost it is essentially running in the A/C mode. You should make sure the electric hea ... Goodman PHKJ048-1 Air Conditioner

Fan on outside will not start on it's on. Have to press reset button. Inside fan cycles on and off.No hum or buzz on the outside unit.


Outside unit is frosting over during heat cycle ? ... Ruud UBHC Air Conditioner

I have Carrier mod#24ANA760A300 Infinity system. 1.5yrs old. Compressor nor fan outside will start. The controller on unit flashes an error for low pressure switch open (error #32). Gas pressure is normal! My technician says that he will have to order a new compressor because of some checks he has done. What I need to know will the controller show low gas pressure if the unit has never started even though the low pressure switch is closed as it should be with proper levels (checked the switch an


No unless there is a loose connection of the wires or terminals between switch and controller ... Air Conditioners

Hi, After finding out that Freon is low by seeing snow/icy surface on outside compressor, I went up in the attic to find snowy/Icy surface all over the coil inside the air handler. I wahsed it and made sure all snowy/Icy surface is melted inside and ouside and Freon is full all the way. Now when I start yhe system fro the Thermostat, the compresor and outside unit start, but nut the fan inside the air handler, so no air is blowing inside the house. Where should I look for ? This is a R


Hello\015\012Your still froze up.There is a freeze cutoff device in the air handler upstairs.\015\012Look for a thin silver color tube near the coil and follow it to the control box,there may be a reset button.If not, try using a hair dry ... Ruud Air Conditioners

Amana AC model MBR2000, installed mid May 2009. When outside temp gets above a certain level the AC does not cool. fan keeps running and it keeps trying but not work. When outside air gets cooler then starts to work again. Tech here twice. 1st time when AC was working - could not find problem, 2nd time when problem was occurring. 2nd time found burnt wire and replaced. Same problem started again 2 days later. AC unit is large enough for our house, is 18 Seer 2 stage. Any suggestions as to proble


Hi it sounds to me like what actvates the 2nd stage of the compressor is not turning the compressor on when the ambeint temiture reaches the point that it calls for the 2nd stage to start it may be an out door thermostat or a ambient senser and I wou ... Air Conditioners

The outside unit is making a squealing noise. It's every now and then; not constant. Just started today. What's wrong? The fan is running fine. The air inside is cool. Just a high piercing squeal every now and then from the outside unit. Any ideas?


Sounds like its more than likely the fan motor. the bearings in the motor are notoriuos for making a squeeling noise. there arent any other parts that would make this noise. unless youre a special case. i doubt it. if youre mechanically inclined ther ... GE Quiet-Aire Ductless Split System Air Conditioner AS1CD12AA0/AS0CD12AA0

Central Airconditioner Heat Pump Weather King Brand outside unit continues to run even when thermostat is disconnected from terminal block base. Have to flip ckt bkr off to turn unit off. Recently it even started up on its own without turning on the fan and started to ice the inside cooling fins. Thermostat is new and was doing same thing with old thermostat.


It sounds like you might have a short in the wiring that goes from the furnace (inside part) to the condenser (outside part). Follow these lines by hand and check to see the wire isn't damaged and shorting out. ... Air Conditioners