No cool air. Thermostat AUX light turned on

\015 My goodman AC heat pump is not functioning properly.\015\012The AC was cooling properly then it turned off and the AUX light came on the thermostat and no cool air. Oddly after I shut the system off the thermostat display started going down in temp (a lot!) from 72 to 58 deg F. Please help! Also, tried to get the heater to come on so set thermostat higher than indoor temp and set system to "heat". System would not come on and "heat" display was flashing.\015\012\015\012The weather has been very humid today.\015

Answers :

I suggest you call a qualified service repair man. There are as many ways to connect a heat pump as there are people doing them. Nothing is standard industry wide that has anything to do directly with color codes, so it would be meaningless to go into them here. The terminals may be adapted to standard but but the thermostat manufacturer may not follow any terminal designations.

However you may just have an extra wire touching one of the terminals inside the thermostat. You can check this by removing the cover. Look where the wires attach to the terminal screws on the thermostat. Sometimes a new service person cuts the insulation back too far here or in the outdoor or indoor units and a "whisker" from one wire can touch the other terminals. A whisker is not the normal case try and move it away from another terminal if its is touching there. However, you may have jumpers in place especially if you have W, W1, W2... at any of the 3 sections, meaning the outdoor, indoor and thermostat.

If you can tell me the terminal designations R,Y, W1, W2, E, G, O, (B)... at the thermostat and the color thereon each, then at the indoor unit terminals or wire designations and the color there, then\015\012at the outdoor unit and the color thereon each terminal or wire designation there. I might be able to help if\015\012the above whisker check you don't find anything.:

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

No cool air. Thermostat AUX light turned on


I suggest you call a qualified service repair man. There are as many ways to connect a heat pump as there are people doing them. Nothing is standard industry wide that has anything to do directly with color codes, so it would be meaningless to go int ... Air Conditioners

When Haier YL M07 air-conditioner is on the Power/Health indicator light is orange colour. The air from the cooling unit is not cool. When I press the HEALTH button the Power/Health indicator light turns green but the air from the cooling unit is still not cool. I would like to know what has gone wrong with my air-conditioner.


... Air Conditioners

I have a dometic dual-therm rooftop RV air with analog thermostat. When I set the thermostat to heat, the unit will hum but the fan does not turn and no air is coming thru vents in the floor. Then unit will blow cold air (hums and fan turns) when thermostat is on cool, but it won't turn off unless I shut it off at the breaker. What could be wrong?


... Dometic Rooftop RV Air Conditioner

I have an air conditioner Appliance AAC 1100 A-PTC that wos working for two days and now its not cooling or heating:-( Both outer and inner parts of the machine seems to be running but it wont heat or cool the room. When i try to turn it on there is a red symbol that lights up on the display (defrosting) this light goes off every 5 minutes or so,then the machine starts to blow air (not heated or cooled) for aprox 20 seconds then the red light comes on again and this procedure starts over again.


... Air Conditioners

Our aircondituoning circuit on the power board shut down yesterday. Both air coditioners stopped. When we turned it back on the airconditioner in lounge room came on with left had light flashing continuosly but no cool air only fan working. I tried turning off the isolator switch outside for 15 seconds. The airconditioner came on with both lights working no flashing for approx 2mins and then resumed to only left light flasing again.Can you assist me with any further ideas? Thank you.Catherine za


Http://www.mitsubishipro.com/media/214656/msh-a18~24nd_servicemanual_ob427b[1]_5-18-07.pdf ... Mitsubishi Air Conditioners

My wife turned off our A/C units acouple of weeks ago while we were away on vacation. Not they are both acting up. The fan is turning and moving air through the exchangers outside, the little red pressure switches are not tripped and the fans are moving air through the ducts inside as well. However, the air is not coming out cool enough to drop the house temp from either of the units. I tried the thermostat reset buttons, checked my filters, (they're clear) and my cooling coils are not iced over


Looks like the compressor is no getting ON.Check thermostat . Bye pass the thermostat and try. Check compressor relay. Compressor capacitor. If thecompressor running and there is no cooling, check the current consumption ... Air Conditioners

I own a non programmable digital thermostast RTH3100C THAT WAS INSTALLED AND KEPT MY AIR CONDITIONER COOLING WELL. HOWEVER, WHEN I TURN TO HEAT IT WOULD NOT HEAT THE PLACE. I JUST GOT COOL AIR. I WAS INFORMED BY YOUR CO. THAT THIS THERMOSTAT IS NOT FOR HEATING. I HAVE AN A/C WITH A PACKAGE OUTSIDE AND AN INSIDE AIR HANDLER WITH A HEAT ELEMENT. COULD IT BE LHAT IT WAS NOT PROPERLY WIRE. I ONLY HAVE THREE WIRES FROM THE OLD THERMOSTAT


Are there any wires on the e or aux terminals. those are the terminals for heat ... Air Conditioners

My air conditioner won't cool and my Hunter thermostat 40135 has a flashing red light!!


... Air Conditioners

Earlier this week, I noticed that the house felt "stuffy" but the thermostat showed everything to be cooling as expected. Last night, the house was definitely warmer than expected when we got home. My husband did some checking and found that the outside unit was running as normal, but there was no cool air coming through the vents inside the house. turning the a/c unit off at the thermostat did NOT turn off the outside unit...was only able to do this at the circuit breaker. It seems that the fan


Nope, nope, sounds like a stuck contactor in the electrical compartment of the condenser, but there are actually several things that could cause it. ... Air Conditioners

When you turn on the AC the cooling fans don't turn on and it throws hot air but when you drive down the road it blows cold air I replaced the thermostat,cooling temperature sensor,and fans relays


WHAT SORT OF VEHICLE IS IT ? ... Air Conditioners

Earlier this week, I noticed that the house felt "stuffy" but the thermostat showed everything to be cooling as expected. Last night, the house was definitely warmer than expected when we got home. My husband did some checking and found that the outside unit was running as normal, but there was no cool air coming through the vents inside the house. turning the a/c unit off at the thermostat did NOT turn off the outside unit...was only able to do this at the circuit breaker. It seems that the fan


If both fans runs (inside and outside), check if the compresor runs , if does probably the unit is low in freon and needs to be recharged after the freon leak has been fixed (remember this is a seal system and it shouldn't leak), but if the compresso ... Ruud UBHC Air Conditioner

Reset button for Ruud Achiever 14 heat pump/AC compressor? My Ac/heat thermostat was blowing fan on and would not turn off. I switched it off at the circuit box, and bought a new thermostat RTH221, wired it and it would not blow cool air when on cool nor warm air when on heat. Called the 800 number for Honeywell and tech said I had wired it correctly, to check outside and see if the compressor was running. It was not. This Ruud unit is only 8years old so I'm wondering if a reset button has


... Air Conditioners

Our Furnace doesnt seem to be working correct. We an: Air Pro BGM075128 and is Natural Gas. It will turn on when we turn up the thermostat.. but we never get any heat through the vents. There is a switch on the side that is "on" and one that is "fan". If we turn on the "fan" only cold air gets blown through. It looks like this is for cool air. So, if we leave the fan off and the "on" swith on, we get the furnace firing up, but no heat ever comes through the vents. I tested out the thermo


Sounds like the blower motor is not working, if the furnace is actually lighting up and the burns are ignited. You should set your thermostat to auto, as if it is on fan then the fan runs all the time until you take it off of fan. I am a little confu ... Air Conditioners

My toshiba split system will blow cold air for about 30min then it will blow what seems to be cool air but not air con cold air when it is quite hot outside. The timer light operation and filter light will flash. I have turned it on and off reset remote cleaned filters. When it's cooler outside it seems to work fine???


... Fujitsu 9RLS 9000 BTU Split System Air Conditioner

I have an XQ08 model - thru the wall When turned on it provide cooling for approx 10 minutes (sometimes longer) and then it stops blowing cool air. My repair man came and adjusted the sensors which he said might solve the problem. It did not. the thermostat is set to 69, I have it set on 'cool', not money saver. When it stops cooling, and I turn it down to 60, it makes no difference and no sound indicating the compressor clicks on. Any suggestions would be helpful. thank you Ms Hill


Hi\015\012\015\012To fix a cooling problem in AC you must know the cooling process that the condenser (outside unit) pulls in the house's warm air and cools it with Freon. The cold air is then forced back into your home through the duct s ... Friedrich Air Conditioners

Cool air comes out when the heat turns on. When I switch to Em heat, warm air comes out. Over the summer the air worker great, however when I switched to heat on the thermostat, cool air came out. Why?


Check the following. 1. Your setting temp must be higher +3 than room temp. 2. Check heating sensor.3. And also heater element.(If it's reversal valve, checke RV is working) ... Weather King 10AJA3601AH Air Conditioner

My thermostat is set on 72....but shows it is 76 in the house. I shut it off yesterday in case it was freezing up. 2 hours later, turned it back on and it cooled great the rest of the evening. I woke up at 3:00 am this morning and was doing the same thing. I shut it off for several hours, now has cool air blowing, but not as cool as it should and still shows 76. Cool flashing on the thermostat.


It sounds as thought the coils on the unit need to be cleaned, make sure it is draining, if it still freezes up after cleaning coils and checking for draining then the unit has a leak and needs to fixed/charged. Hope this helps tim ... Air Conditioners

Weather King 8PJ10NDR01 When I turn the heater switch to ON position the furnace runs what sounds like an internal fan. Second, the igniter glows and when it reaches it's hottest stage the fan thrusts air through the air ducts / vents and the burners light for about 30 seconds to a minute blowing cool air. After a period of about 30 seconds to a minute the burner turns off. After the igniter and burners repeat this about 2 times the heater shuts down by it's self, even when the temp gauge has no


The gas valve is not sensing flame, and the unit shuts down on safety.\015\012\015\012Chances are the flame sensor is bad, its a common problem.\015\012\015\012If its a thermocouple you can buy one for 10 bucks, If its a newer ... Weather King 12AJA4801AH Air Conditioner

Ac problems i have a goodman ac system. i can not get it to cool one side of the house. i have it turned down to 72 and the thermostat says it is 80 in the room. i can hear the return vent sucking air and the ac unit outside is running but no cold air is coming inside. the unit outside has cold air coming out the top when the fan inside it is turning


Hello from KOOLBREEZES, this is a simle problem and easy to fix. You have 2-lines going to / from your outside unit. a SMALL COPPER -line and a LARGE COPPER line with insulations. The fat line is suppose to have moisture on it wheres it,s not insulat ... Air Conditioners

I have Scheu Universal 250-VC/250-S, SPC-250VC/SPC-250S, 250,000 BTU Construction Heater that lights great and puts out the heat, but the air flow running past the pilot light "bends" the flame away from the thermostat and it cools down and shut off the gas flow. What can I adjust to keep the pilot light from "bending" away from the thermostat?


Just a thought, but...is the compressor in any way blocked by weeds, etal.\015\012\015\012bon chance\015\012\015\012Ashley ... Air Conditioners

I have a Goodman CPLE42-1 split system. I had a power outage and my first floor unit would not cool anymore. The air handler/blower in the ceiling is working fine, but the fan outside is not turning on. When I went to look for an overload reset on it, I switched off the breaker on my second floor unit by accident, and now it is doing the same thing. Both fans on the outside will not turn on. Both thermostats will turn on the air handlers in the ceiling. Seems like I re-created the same exact pr


... Goodman CPLE24-1 Air Conditioner

My unit is running but not blowing cool air. I went outside and the condenor fan was not moving. Took a stick and shoved a blade and the fan started moving but the air is still not cool inside. I did notice the air coming through the unit outside after fan was blowing was cooler than my 2nd a/c unit that was working fine. I wondered if the entire unit was frozen. I turned off unit at thermostat and figured I would see what happens tomorrow


Sometimes on new units it is common for the fan to not start until you give it a push. Did you happen to hear if the compressor was operating? If the unit was froze-up the Insulated Suction line would also be iced over as well. If it wasn`t it is mor ... Carrier 38CKC024 Air Conditioner

I have a suburban lp furnace and duotherm air/heat pump roof unit. duothern thermostat. 20 amp breaker kicked ( reset breaker) & furnace quit. NOW furnace fan comes on but does not light, and the front AC will not work either, when in the COOL position on STAT the unit blows warm air instead of cold. I replaced the Thermostat and a Tech guy checked the board in the furnace and it was OK. He also switched the board from the rear air with the front and nothing changed. Rear air and heat pump works


I'm not sure what the problem may be but you could try calling All\015\012Seasons RV Appliance Parts & Service. There number is\015\0121-800-344-0673 they have helped me in the past. That and there tech\015\012calls are free so it wouldn't hurt ... Dometic Rooftop RV Air Conditioner

Hello, When I set my AC unit to "Heat" and turn it on, the air will come out warm, then after a few hours the air starts to come out cool. To make it warm again I need to set the thermostat to Off position for a few minutes then turn it back to On position then the air comes out warm again. Any idea what could be going on here? thank you!


It sounds like you have a heat pump. When you first turn on the system the heat strips will come on and produce warm heat (referred to as supplemental heat strips), as temperatures rise the heat strips will turn off and the "A" coil will just exchang ... Air Conditioners

I have a 2011 Wildwood travel trailer. I tried to use the air conditioner for the first time this weekend. When I turned the themostat to cool and 65 degrees the air unit "clicked" one time but the unit did not start. I tried various settings but nothing. When I turned the thermostat off the unit clicked one time again. This is a brand new trailer and the first time I tried the air. Any thoughts?


First thing to check is that the breaker for hydro to AC unit is in the on position. The clicking sounds like 12 VDC is OK but hydro may not be on to it. ... Dometic Rooftop RV Air Conditioner