Having problems with your Air Conditioners ?

ROOM SIZE SUITABLE SIZE OF ROOM TO INSTALL,12000BTU-24000BTU


Answers :

Work on around 650btu per square meter.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

ROOM SIZE SUITABLE SIZE OF ROOM TO INSTALL,12000BTU-24000BTU


Work on around 650btu per square meter. ... LG LS-L1210CL Mini Split Air Conditioner

I would like to know while designing of duct how will i calculate the cfm Air discharge in units like CFM through a collar opening? What is the formula for giving the collar size for air discharge. Lets for Example I have a AHu of Capacity 1200 CFM I have to distribute the total cfm equally through duct on three seperate room . then what will be the duct collar opening for each room so that each room will get 400 cfm each? RegardsM.A.Shah09314545556


You'll have to pay for that info.. ... Air Conditioners

I have a new Mitsubushi 18,000 BTU Mr. Slim ceiling mounted (SEER 13.2) Comfort System. It is for one room only sized 20' by 20' by 12 ' high. The room is on the second floor, has no windows and is insulated on all sides. Like other posts I have seen, the Mr. Slim generally cools the room (even at 100 degree outside days in Texas) to 75 degrees or lower but the humidity immediately goes up within the first 1 to 2 hours to 60 to 70% relative humidity. I have complained and Mitsubishi authorize


A/C units do not remove all humidity - that is the purpose of a de-humidifier. Instead they STABILIZE the humidity in the form of condensation when the hot refrigerant is misted into cool vapor. The humidity condensate collects on the coils... thereb ... Air Conditioners

Window A/C maybe to small for the area, I need to know where you live in what state, lets have some more infor. on the unit and size of the area your cooling. Under sized Units are the biggest problem - People buy price and not the proper Unit for the room or the house .


General btu size for AC is rated at 1 ton cooling per 500 square feet.1 ton equals 12,000 btu. ... GE AGQ10AJ Wall/Window Air Conditioner

Anybody there? i have a computer room that needs to be cooled at all times room size is 10*20 temp far 108 degrees needs to be 85 degrees humidy needs to be 45 which ac unit do i need thank you for a fast reply


It depends on the room varables, If it has an attic, tile ceiling, what type of walls, where in the building is the room and so on? The biggest problems is all ways the power. Get a free estaimate from an ... Frigidaire FAA055N7A 5200 BTU Room Air Conditioner 11.0 EER, With Remote Control

I have a room size of 27-30 square meters room. how much horse power air conditioner will i need to buy?


... Air Conditioners

We have AC LG Zet cool 1pk, with size room 5x6x3, the problems is we doesn't have cool on the room, but ac is good condition with standard free on. pleas e help me to solve this problem. thanks. RS. Urip Sumoharjo, Lampung, Indonesia


Depending on the type of building and insulation. For building with good insulation and not many windows, you could manage with a 18000BTU, but if your insulation not so good, you should need 24 to 26000btu unit. ... LG Air Conditioners

I own a Zenith Air Conditioner, model ZW651OR. It is only a month old and it is not blowing cool air any more. I live in Guam (relatively a hot climate) the size of my room is 10' X 12' and the air conditioner runs pretty hard to cool room, what could be the problem


The problem could be dirty filters, dirty coil, refrigerant charge low,etc. Since it is only a month old I would try to return it if possible. ... Air Conditioners

Hi, I am going to purchase a 12000 btu 1.5Hp portable aircondioner unit for my living room of around 42 m^2 (7 metres wide and 6 metres in length). I am wondering if this unit is suitable for the room? Help is needed, Thank you, =D


Hello =D12000 BTU will cool approximately 450 to 550 square feet. That's around 137 to 167 m/2.Unless your name is Beelzebub and the room your trying to cool is really really really really south (or in this case down). =D <that' ... Air Conditioners

Max size room for effective cooling?


20 x 20 = 400 square feet ... Air Conditioners

I just installed a Klimaire KSWG009-C113. It cycles on and off approx. every 3 minutes. Line set vertical drop is 20 ft, total is 25 ft suction pressure is 115 to 125 psi indoor temp is 32 degrees C evaporator is in a 9 x 10ft room apartment size is 500 sq ft I'd appreciate any solutions. Thanks


... Cfm Klimaire KSWG009H113 Split System Air Conditioner

This same unit was installed 2 months ago with the MUA 12WA and it is just to small to handle the room .The installer siad he will increase the compreesor size to a ton and a half but said the wall mounted unit does not need to be changed and will work fine with the larger outside unit ,is this correct?


... Mitsubishi MS-A12WA Air Conditioner

I have a WINTAIR portable room air conditioner AP-08CK1FDS,8000 BTU. I don't have the manual to order the vent hose & window size kit, and I have a condensation drain hose, am I suppose to pla


... Whirlpool ACP092PR Portable Room Air Conditioner

My air condtioning unit is a GE unfortunately I can't se what btu but ev ry our the coil freezes and its spitting out water. Room size.


Clean the coils its freezing up because the air flow is restricted because of dirty coil or filter after cleaning the coils and it still freezing up then it will need some refrigerant aka freon ... GE Built-In Room Air Heat Cool Air Conditioner

I wish to install a kelvinator split system and id like to have the condensor under the house, the underside of the house has heaps of room 2.5m high 4m across and about 15 m long. there are air vents and a door sized opening to get underneath. is that sufficient space to be compliant with warranty??


... Air Conditioners

RECOMEDENT SIZE OF ROOM TO USE SPLIT UNITS FROM 12000BTU TO 24000


650btu/square meter ... LG LS-L1210CL Mini Split Air Conditioner

THe unit has only changed the temp from 89f to 86f in a medium size room ???


The portable AC units have a limitation when it comes to cooling a larger area, Since the unit is meant mainly to be focussed to an area it cannot be compared to the split unit or the window unit where we have the heat exchange exitting into open air ... Danby DPAC7820 7,800 BTU Portable Air Conditioner

I have a Fedders Air conditioner model #A3X05F2A. How many BTU's is it. And what size room does it cool? I got it used so I don't have owners manual.


5,000 btu's\015\012To calculate LxWxHx18 divide by 5 ... Fedders A3X05F2A Air Conditioner

I just bought a 24000BTU spilt type inverter room air conditioner. It was installed with professional equipment and the vacum was tested. When it was first started it gave an E4 error. we reset the breaker the error went away that was 3 days ago. we tried it on heat the first day worked alright , the second day we tried the cooling it was alright, that night i put it on fan it worked all evening and night then yesterday it gave me an E4 error again . we reset braker the error would not go away.


... Air Conditioners

What size air condition do I need to cool a 350 sf room?


You need at least 9,000 BTU AC Unit, however most\015\012AC units will tell you what size room they are capable of doing ... Air Conditioners

My split air conditioner compressor fail is it due shot pipe length total pipe length less then 1.5 mt.unit is 1.5 Tr and room size is 160 sq ft.using steblizer.


A/C compressors fail because the system is overcharged, not enough charge in the system. Compressor can also fail if it's started before it has a chance to cool down first. ... Air Conditioners

Ac is putting humidity into the room air


There are two three possibilities that has to be checked.\015\0121) Is the ac turned to fan mode or AC mode.First check that.On fan mode it will not give much cool.\015\0122) If the fitting of ac is not perfect then it will make the compressor of the ... Haier Mechanical Air Conditioner HWF05XC7

Royal Sovereign not keeping the room cool.


Electronics give off alot of heat you need larger unit ... Royal Sovereign ARP-4009 Portable Air Conditioner

Determining replacemnt duct size


Hi,\015\012\015\012You can find all the information you need in the document which I uploaded for you. Please click THIS LINK ... Ruud UAKA030 Air Conditioner

The 10,000 BTU portable room a/c unit is not running cold enough


Make sure your vent is closed. check the filter to see if its clean. If you run the a/c you can check your evaporator to see if you have condensation or does it freeze up? \015\012 Make sure you have your unit on early in the morning. If you tu ... Whirlpool ACP102PR Portable Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific