Everstar portable ac unit displaying error message P1. The unit turned itself off and will not come back on. It had no symptoms of not working well before turning off.


Answers :

According to my Everstar manual, P-1 is a drainage problem.
EverStar owners manual pg. 16 -

1. Release the drain hose from the ruber clip and pull out the rubber plug, let the drain hose slant down to a water container.

2. Press the TURBO button on the unit control panel for more than 3 seconds and the WATER INDICATOR light begins flashing. It indicates the forced water drainage feature is activated.

3. Waiting until the WATER INDICATOR light stops flashing and there is no water flow.

4. After the water has drained, remember to secure the drain hose and plug in the upright position and clip it to the unit.

The unit will return to normal operation.

....I had to do this and it worked - Good luck!

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Everstar portable ac unit displaying error message P1. The unit turned itself off and will not come back on. It had no symptoms of not working well before turning off.


According to my Everstar manual, P-1 is a drainage problem.EverStar owners manual pg. 16 -1. Release the drain hose from the ruber clip and pull out the rubber plug, let the drain hose slant down to a water container. 2. ... Air Conditioners

We had a brand new unit put in a couple of years back. When it was installed it worked. Once winter came, it obviously was turned off. Then the following summer, it would turn on but just blow air, would not cool at all- so the unit installers came out and repaired it. It worked through the summer, then the following summer-it wouldnt cool again-they came back out and fixed it again. Third summer in a row-it is not working again!! A friend told me this morning, on new units there is a


Yes but you should have to keep resteting it you might have a major problem are you beiing charge for freon if so you have a bad condensor unit (it have a leak ) check your bill if the same thing happens again go see what the techs are doing ... Honeywell Air Conditioners

My unit is 4 years old. I always turn it off when I leave for work in the am and turn it back on when I get home in the pm. Last night I turned it on at 7:30pm. When I went to the front of the house about 45 minutes later, I noticed the unit outside was trying to turn on but would immediately turn off. I checked the breakers in the garage, turned them off and back on but still had the same problem. The fan inside the house is running but unit outside will not kick on. I looked for a magic


It could be a few things.. It could be the capacitor - which the most economical to replace first..\015\012\015\012If you are not really very mechanically inclined - get a trained pro to come out.. It is very dag ... Air Conditioners

There is a switch on my 1 1/2 ton Ruud furnace/Air handler that is not working properly. The unit would not turn on, even though the thermostat was working. I took the panel off of the air handler and found that a switch had been duct taped into the on position on the unit. Apparently, the tape had shifted and the switch was no longer in proper position. when i moved the switch, two green indicator lights lit up. When i turned the unit back on, the A/C worked. Clearly, there is a problem w


Helllo, this switch is called a door interlock switch. ... Air Conditioners

My AC My Compressor keeps kicking off. I turn the unit on, the fan works. The Heat works but the compressor turns in about 60 sec. If I unplug the unit and turn it back on, it comes on but the compressor shuts off again after 60 sec. Can this be from dirt in the coils? They have some build up. Any other causes?


One might think so, YES the compressor is running till it gets hot and tripps on hi-temperature, and after it cools down awhile, the switch willcautomatically reset itself and back- & forth......Thank-you-very much! ... GE Zoneline AZ38H12DAD Split System Air Conditioner

My fan and heater work fine, but today I turned on my air conditioner for the first time this year. It did not feel like it was getting cooler so I went outside and noticed that my outside unit was not working. I went and checked the breaker and noticed it was tripped, so I turned it off and turned it back on (the breaker). Then all orf the power went off to my house. I then reset my whole breaker box and I heard what sounded like my outside unit explode. I ren over to it and it sounded lik


You had a refrigerant release. Probably two lines rubbing together in the outside unit. I have repaired several of these with this problem. It involves repairing the lines by silver solderingthen pulling a vacuum/ purging with nitrogen an ... Carrier 36KCARMS Air Conditioner

Unit was running and now will not turn on. Outlet checks out ok, house fuse switch has been turned off and on, unit will not come back on. Could the unit have a fuse? How do I find it? Unit is too old to locate a copy of the manual from Sears. Electrician was working on electric and was turning the main switch off and on, unit was on and then quit.


Check for an inline fuse in the unit or replace the capacitor ... Air Conditioners

I have an Amana Model GUC-C 90 Hi-efficiency furnace that we installed in 1992. It has a central air unit as well. On Friday we tried to turn the air on and nothing will work. I have replaced switches in the air unit in the past but this time there is no clicking, I can't turn the circulation fan on for the unit, the heater unit will not turn on. I have power at the breaker, and on the unit itself there is a on/off switch with a round screw in fuse, that fuse is good and I have power there.


Hello,Your control transformer may have quit on you, or your thermostat may have gone out. The transformer is what supplies the current for the hvac system. The thermostat just controls what relays are energized. Since you have a probl ... Air Conditioners

It has power because the screen is lit and shows E-2. Unit does turn on but dies after a few seconds and E-2 comes back on. I also have a another Friedrich, a WallMaster that is also not working. I do knot know the exact model. It too is not working. The green light shows when I plug it in but the unit will not turn on when I press the power.


E2 error code means indoor coil temperature sensor broken (fixed in evaporator coil)..This error means that the\015\012unit has gone into a protection mode, its the reason because not operating. ... Coleman Air Conditioners

AMCOR 24,000 BTU split system. Worked fine two years, then today it had no power. Checked circuit breaker, it had popped. Reset CB and went to inside unit - would not turn on or off with remote or hard button. Checked wiring with an electrical tester, and wires to outside unit hot, as well as inside unit. No flashing codes, nothing. Unit won't turn on,even with power. Is there a fuse somewhere in the inner unit or outer unit?


I had this same problem. I disconnected the thermostat wire out side at the condenser and reconnected it and it started working. A couple days later it blew the breaker again this time I found the bus where the L1, L2. GR wire connect at the condense ... AmcorAire UCHW-H24AF2 Split System Air Conditioner

Our Carrier 38ckc036350 is not working - the outdoor unit was very hot to the touch and will not turn on -turned it off at the thermostat - later when the unit cooled down turned it back on via the thermostat and it would start to kick on, but then stop - no breakers were thrown. Unit will be 7 years old in the middle of July '10 and am wondering: 1. what could the problem be & 2. will any of this be under warranty?


The first thing I would check is to see the condensing coil is clean. Take a garden house and wash it thoroughly. If it is severely clogged you may need to remove the top and clean it with water pressure blowing from the inside out. This may stop the ... Carrier 38CKC036 Air Conditioner

I have a goodman gsc13 ac unit about 4 year old. When the temp gets around 90 or above outside the fan on the unit starts but the compressor does not. I had service check it out but that day they were here it was in the 80's and it worked fine. I replace the thermostat to make sure that wasn't the problem. Interesting if I turn the unit off at the thermostat and wait 15 minutes and turn it back on it will run fine. But the next time it tries to turn on automaitcally it will just be the fan o


The hum you hear is the 24v transformer which is powered form the air handler inside have you tried a hard start kit or had cap checked ... Air Conditioners

My carrier air conditioning unit does not cool below 72 degrees. I was continually running to the point the outside unit connection to the house was frosted. I turned the unit off and let sit for a few hours. Turned it back on and the Thermostat seems to be working; however the unit can not cool the house below 72 when it had in the past. Am I looking at a leak or re-charge???


The unit has lost part of it's charge, and will need recharged. For that reason a leak must be found and repaired or it all will reoccur again. ... Carrier 38CKC030 Air Conditioner

Honeywell F50F 1065 electronic air cleaner. Replaced power supplies in two units, installation went well. One unit works as it should. Second unit turns on for just under a minute and then goes off. After two or three minutes unit can be turned on again but only for a minute or so and the problem continues. All wiring and switches seem to check out fine. Any thoughts or pointers you can give me?


... Honeywell Air Conditioners

I have a dometic ac with remote in our 2005 Keystone Zeppelin z261. We are camping in 95 degree Florida. While taking a nap, the ac remote quit working with the unit running wide open cold. I changed batteries in the remote, no change. The control panel on the unit itself showed the green light for cold, but the control did not respond. Turning off the main breaker made the unit turn off, reseting the breaker made the ac come back on. When I unplugged the modular cord connecting the control pane


... Dometic Rooftop RV Air Conditioner

Outside unit is running however it is not cooling.I cut off the circuit breaker wait 20 or so minutes and turn it back on and the unit works perfect for a while (no set amount of time ranges from hours to days) any ideas?It is a new unit and did the same thing when it was turned on for the first time.Worked 2 weeks before starting again.Unit is a little low on freon.It is a Goodman 3.5 ton ac only(gas furnace)


Sounds like there is a Freon leak and has been since it was installed and is going off on because of low charge, you will need to call a competent A/C repairer, more then likely the leak will be in the air handler, should cost under a $100 to fix. Go ... Goodman CKL42AR42 Air Conditioner

My thermostat on my ac keeps resetting itself to 86. i can turn it down then it goes right back up. it is a window unit about 2 yrs. old. i keep trying and eventually it starts working again. works for about a day then does it again..the buttons dont seem to be working right on the unit when it is acting up either.


... GE AJCQ08ACB Air Conditioner

I have a Goodman Split Air Conditioner and the outside condenser fan was not working. relay tested ok breaker wasnt tripped, then discovered 1 leg of the 220 line was out. Replaced the breaker, cleaned the unit turned it on, cooled the house 2 degrees then it stopped working. Turned the stat off ,pulled the 220 block waited 10 minutes, turned it back on and it is currently running. Can the relay and/or start-run cap behave in this kind of intermitent way ?


Run cap may be badthumbs up ... Air Conditioners

My goodman furnace (model gmp 108-3) is not working. If I turn off the unit and turn it back on the fan comes on and the little filament heats up, then the top burner will light, but it will not stay lit and none of the other burners will light. After a few tries, it turns off and doesn't come back on.


All of the burners should light. Could be a dirty flame runner. I recommend that you get a good clean and check.. Burners, flame runner, flame sensor should all be cleaned. If this does not solve your problem than the gas pressure nee ... Air Conditioners

My ac unit will not go below 77 degrees. It quit working about 1.5 weeks ago, and I had a service technican come and look at it. He replaced the capacitor and the unit started back up and would cool to 75 degrees (where I usually have it set). He checked the pressure of the unit as well and said that it was fine. However I came back from a trip and the thermostat read 77 degrees even though I have it set on 75, and the temperature will not go any lower. This is the same thing it was doing


Hi, It sounds to me like you have covered all of the basis. The evaporator coil should be clean if you keep your filter clean and the condensation is showing that it is cooling properly. Normally, when the temperature increases outside, you will loos ... Air Conditioners

Tempstar 5000 This spring I turned on my air conditioner for the first time and it would not start at all... The fan did not turn on either. I turned off the main 220A breaker and puller the control fuses and put everything back and the unit started working fine. now fast forward to yesterday... house started feeling warm so I did the same thing... Tripped the breaker. Pulled the control fuses, and this time made sure I had new batteries in my thermostat. Started to work again. All was good. pus


... Air Conditioners

I have the AS12AA(B)MCF unit with US12AA(B)MCF. After I turn it on in the standard mode it will shut off after 1 to 5 minutes and the nature mode light blinks. Does not turn back on by itself. Try and try again with same results. Then sometimes it will turn on and work fine, like this morning , at least for the 1.5 hours I was around to observe. The outside unit is located on the side of the house that gets afternoon sun. Help!!!!!!!!!!!!!!!! Peter Roomet


I can't answer your question, sorry, but there is a site, and if you join, you can get the Service Manual for free, and they have a troubleshooting guide that might help out. Here it is:\015\012 ... Samsung AS18A6RB Air Conditioner

We had a terrible thunderstorm and I saw a flash of light near our transformer. All the lights in our house dimmed. Since this had happened before and we damaged our capacitor, I immediately turned the AC unit off(Amana Prestige II). When the power stabilized I turned the unit back on but the compressor will not come on. I tried turning the breakers off and on but it did not work.


Well, that;s not good. whenever there are thunder and lightning around, you should always UNPLUG, to disconnect EVERYTHING from the wall, simply turning OFF, is NOT sufficient. \015\012I would expect that the induced current from the lightning, will ... Amana Air Conditioners

I have the mitsubishi mr slim indoor model msz-a09na in my living room and bedroom, upon awaking this morning the living room was noticably cooler than the 64 degree setting ,i then noticed that the left indicator light was blinking, when i turned on the bedroom unit the same thing happened, i turned both units off for 5 minutes when i turned them back on they appeared to be working ok, this also occured about a week ago... i notified my landlord but he doesn't think this is a problem?


... Mitsubishi MS09TW Air Conditioner

I have a Tempstar 9000 airconditioning unit and while I was weed wacking I accidently cut a wire to the unit. I replaced the wire but now the unit wont turn on and also my furnace blower wont work even in the "on" position. I have a energy saver unit attched to the a/c unit as well. One wire connects to the a/c unit and the other to the energy saver. If I push the connector on the unit with the panel off the unit will run. Cansomeone tell me how to connect those four wires?


Hello TLOEKS You blew the transformer FUSE inside the blower unit! It should be a 5amp blade fuse like the one that goes in a car.It is located at the curcit board at the blower compartment.Replace that to restore low voltage power and every thing wi ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific