COILS FREEZING OUR A/C UNIT IS 11YEARS OLD, THE COILS KEEP FREEZING AND THE THE CONDENSER IS RUSTING SINCE LAST YEAR. WE HAVE ALWAYS KEPT THE FILTERERS VERY CLEAN. WE SPRAYED WATER AND DAWN DETERGENT ON COILS FOR A LEAK (NO BUBBLING) IS IT TIME FOR A NEW A/C AFTER 11YEARS.


Answers :

If your coils and filter are clean and you have good air flow then you are very likely low on refrigerant. Most A/C's (depending on use) have about a 20 year lifespan. I would call a Tech. to check it.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

COILS FREEZING OUR A/C UNIT IS 11YEARS OLD, THE COILS KEEP FREEZING AND THE THE CONDENSER IS RUSTING SINCE LAST YEAR. WE HAVE ALWAYS KEPT THE FILTERERS VERY CLEAN. WE SPRAYED WATER AND DAWN DETERGENT ON COILS FOR A LEAK (NO BUBBLING) IS IT TIME FOR A NEW A/C AFTER 11YEARS.


If your coils and filter are clean and you have good air flow then you are very likely low on refrigerant. Most A/C's (depending on use) have about a 20 year lifespan. I would call a Tech. to check it. ... Intertherm P3RA-030K Air Conditioner

I have a Intertherm split a/c heat unit. I have water leaking out of the indoor coils into the blower compartment which cause me to replace the blower unit and cap. After cleaning the coils, drain lines and verifying the pan is not cracked or broken it still is leaking into the blower compartment. Almost like it is sucking the water right off the coils. What could be the problem????


Drain could be clogged not letting the water run out did you clean both under the coil and the top of the coil if you did all this I would turn system off lift coil slightly and fill pan with water afer i got it completely dry this will show you wher ... Intertherm P3RA-060K Air Conditioner

Water dripping from my evaporator on my Nordyne mobile home a/c system is leaking water from drip pan , I have cleaned the drain line but is leaking onto the floor and into the duct work has already ruined my floor , new motor has been put in and since then water everywhere.


... Coleman Intertherm Nordyne 120 24 Volt 15va Transformer 7945-355 S1-7945-3551

I need to find a leak in my Carrier Air Central Air cond. I'm thinking it may be the A-coil as it keeps freezing up. Can I use compressed air and soap/water spray around the A-coil to check for leaks?


MOST LEAKS ARE AT THE SERVICE VALVES AT THE GROUND LEVEL OUTSIDE UNIT OR SERVICE VALVES AT ROOF UNIT. THESE VALVES LOOK LIKE TIRE VALVES.THEY SHOULD HAVE CAPS AND SHOULD BE TIGHT. REMOVE CAPS AND LOOK INSIDE CAPS IF YOU SEE OIL IN THEM THAN THAY LEAK ... Air Conditioners

I have an intertherm AC unit (model E2EB-015HA) and the inside unit is leaking and damaging my floor. We discovered this last summer and assumed it was a combination of condensation from the unit and freezing up. As it did freeze up and we caught it rather late. I did a good cleaning, filter replacment, and checked the line running out of the water-pan and it was not clogged and water was flowing well. I fixed some floor damage in my hallway and kept a close eye on the unit. This summer it has s


I realize this post is a few years old, but I keep having the same problem. Just got out from under my trailer draining water out of the insulation. I noticed when my unit was running that the water in the pan was being pulled back towards the insi ... Intertherm Air Conditioners

Own a whirlpool low temp dehumidifier model AD75USTO that collects very little water despite running all day in a basement with humidity level of 70% at about 60 deg F. I opened the case and saw that the coil remains frozen. I also noticed a thermistor mounted on the coil. Possibly this circuit is not working. I sprayed the thermistor with a freeze spray during operation and the compressor didn't do anything?? Help!!


The unit is u ndercharged, it has a sealed system leak that needs to be found and repaired then recharged ... Air Conditioners

Coleman air conditioner is leaking water from the unit down to the floor. Is there supposed to be some kind of drain on the unit or some thing to keep the water from falling on the floor. We have cleaned the unit and installed new filters but still leaks.


... Coleman Mach III Air Conditioner

Ceiling leaks There is a water leak from the ceiling vent that contains the coil, pan, etc. I sealed the pan with epoxy and putty. I also cleaned the sink drainage tube with a wet vac and replaced the filter. It seemed to stop the leak for a week. Now it leaks again, but it does not leak when I remove the filter. So, i am running it without a filter.


Coil is dirty or frezing up allowing water to leak. ... Ruud UBHC Air Conditioner

I have a Carrier 58DX080CC Forced air furnace that is leaking water onto the floor, but otherwise works perfectly. A service guy told me I need a new Coil, but it probably wouldn't pay to repair it, and that I should replace it. His quote to replace was about $6K. I found the part, Z7-58DX080CC-91CW at United parts supply for $890. The unit was manufactured in 1988 and is 90% efficient. What should I do? Buy the part and hire somebody to fix it? Buy a new one? The new price he quoted wa


Hi,If you are running a high efficiency forced air furnace then check the\015\012drain hose and make sure it isn't blocked or crimped. These furnaces\015\012tend to take a lot of humidity out of the combustion air (air from\015\012outside ... Air Conditioners

I am reviewing my ac unit from condenser(outside) to evapoarator (inside). The inside evap is freezing-up,???I am blowing out evap (it looks clean)and cleaning blower and all air handling (they look oK). I have had service (SALES CALL) from big HVAC contactor ( says need new unit 12-14G ) says he will fill freon 2-3 lbs ($189 + 90 first lb, and $60 each additional lb) NOW after reading all your responder"s comments, I suspect the schrader valve is slightly leaking (I have had this happen on tire


I would suspect the unit was freezing up the whole time you were out if the ice is all the way out to the condenser and over the compressor as well as it being thick and solid. The shrader type valve could have finally leaked out enough and you can c ... Whirlwind FH-778 Air Conditioner

I have a friedrich wall mount model: MW09C1B it is leaking water on floor have blown out tray,drain hose cleaned coil and still leaks any solutions???


... Friedrich M18CF Split System Air Conditioner

We have a weather king select 90plus not really sure of the model number but when we turned it on it was running fine then all of a sudden the outside temp was 90 and inside temp was 81 and it could get cool inside then we went downstairs and saw water at the bottom of the unit and the unit was sweating so we thought maybe it froze up,cut off unit for a while then cut back on and still water running from unit, company can in and said we have a leak somewhere and might need a new coil not sure th


Is this an upflow furnace? If it is, there needs to be a "P" trap in the condensate drain line. You need to check to see if there is. A "P" trap is a "U" shaped\015\012tube or fitting in the condensate drain line. The first time you run your un ... Air Conditioners

Carrier Infinity AC indoor unit in the garage is leaking water on the floor. There is no ice on the coils, The drain is not clogged. There is no water in the coil area. I turned off power to the indoor and outdoor unit and it continues to leak water. I finally shutoff the water supply coming into the house. The leak then stopped. The unit is on a wooden box approx 3 feet above the floor in the garage. The only water seen is on the floor. I open the side of the A/C unit an


Hi,It seems as though you have an unrelated water leak.... Often the water supplies are copper tubing....Copper tubing and concrete do not get along well...but hey it lasts till the warranty is up....and they can't see i ... Carrier 52CQ315 Air Conditioner

My parents had a frigidaire eletric heat pump installed 2 years ago. almost right away a soured water smell came out of the vents. service tech sprayed the coils and installed a black light. did not help. service tech said frigidaire did have this problem with some of its units. so the unit was replaced. new unit done fine for about 6 months. now the smell has came back mainly when the cooling is on. any suggestions. i dont believe it is the unit. they had a gas it pump before.


I feel that the gas lis leaking from a very minute hole which gets enlarged when the unit is cooling (it gets hot and enlarges). And it could be leaking from anywhere. A quick temporary remedy is to seal the possible leaking points with super glue or ... Frigidaire Air Conditioners

AS-H126PBL2 Coil is freezing up and water suudenly overfloors into the room floor and soak the carpets furniture etc. this happens in brand new Art Cool AS-H126PBL2. even the local agents cannot solve this problem and I do not recomend this Art Cool model to. all the known people whom got this particular model has the same problem. We people in Sri-Lanka must not go for this model as the Agent Abans Limited cannot solve this problem.


Check the web page and manufacuure specs on the model#! ... LG Art Cool LA121CNP wall/window Air Conditioner

Hello, my HVAC is constantly freezing, even after freon is added. I was told that I have a leak in the coils and need to chance the air handler - the outside unit is about 10 years old - air handler about 18 years old. I would like to get only the air handler for my R22 outside condensing unit. My question is if in the future can I use this same 3.5 ton air handler with a new 410 condensing unit once my outside unit needs to be replaced. In other words can a Goodman air handler be used firs


I'm new at this and I can't tell how old the post is but I'll contribute anyway.You probably have fixed the problem by now. I wonder what part of the system is freezing up. I don't have a lot of experience but I know you can get frost where there ... Goodman CKL42AR42 Air Conditioner

My window air conditioner keeps freezing and leaking water does this mean i need a new part for it? the model number is FAA060P7A5


It is normal for airconditioner to have condensation. Just make sure the water don't go in the house. LOL ... Air Conditioners

I have a carrier weathermaker 9100 air conditioner / furnace. When the ac is running, water from the evaporater coil doesn't drain. It builds up around the colil and leaks all over the floor. I took apart the drain tubing sections and blew air through tehm with an air compressor. Some crud came out and I thought it would take care of the problem. It worked for a short time and now does it again. Is there something I am missing? Could there be something else that needs to be cleaned? Any


Most likely you will need to pull the coil to clean the drain pan area around the coil ... Carrier Air Conditioners

I have a central air weather king unit just moved in this house first time turning it on we got a leak in our ceiling, the tray is full of water we checked the white pipe leading out from tray it is not clogged up and filter is new and clean


Ok first blow out the line that is on the coils if there is two do both of them ,after that then treat the lines with bleach to get rid of the build up in the lines now treat the coils that the pipes go to ,clean coils then pour bleach in the bottom ... Air Conditioners

My GE Portable AC will only turn on intermittently. Water bucket is empty. Filter and coil are clean. Circut breaker has not tripped. I think the power button is broken. This unit is in pristine condition and has been used very little, it looks new. What do you think the problem is?


Have you recently moved the location of the AC? Is it connected to the power point as per the instructions given in the ... GE APN10AA Portable Air Conditioner

My ac unit is leaking through the coil box, I cleaned the drain, but it still leaks from the side of the box. Could it be cracked? the unit is 9 yrs old


Could be a cracked condensate pan. this may require replacing the pan or there are sealing sprays on the market which you can buy at HVAC stores. ... Weather King Air Conditioners

Water leak my ac has been clean recently now i have water driping, the drain line is clean,the pan is clean but the insulation near the pan gets soak wet and it leaks. coul some one help me.


HI,Please CLICK HERE for some very useful info.\015\012\015\012This is a very common problem that is easily solved. The way your air\015\012condi ... Air Conditioners

Condensation water is not draining properly on Goldstar AC window unit and backing up and dripping on the wood frame and floor below the unit. Is something blocked it just started happening. I am going to clean the little pipe that water drips from outside but it involves climbing a latter. Also I am going to clean the condenser coils...is there another reason or anything else I am missing and do you clean the condenser coils with little wire brushes? It occurs after the unit has been runnin


Yes,remove the ac unit from the window,and clean it out with a water hose out side,remove all debris from inside the unit,and tilt water out of unit.Make sure there is nothing in the way of the drain,and when the unit is put back in the window,make s ... Goldstar KG6000R Window Air Conditioner

Intertherm Air Handler Coil leaking water


Replace it it's junk - going to do that this time because this is the fourth year of the same problem on the hottest days this intertherm junk downflow ac unit condensates where it will not and con not be captured by the pan - built by relatives of t ... Intertherm P3RA-024K Air Conditioner

My daughter has a Bryant AC Model number 563AN048-A where the outside coils are freezing up. The repairman has been out twice and has cleaned the coils on the inside and outside units and has checked the coolant levels that he says are ok. Currently, if they remove the cold air return filter, air circulation is increased slightly and in doing so, the outside coil is not freezing. Can't run the system without a filter as the internal coil will clog. Any suggestions would be appreciated. Assoc


Hi, this is a 4 ton unit, Bryant are top of the line, I believe so as I have worked on them for so many years. They were Day & night, just a name change is all. Here is what sounds like your problem is, or is your problem. Did the tech check the ... Air Conditioners