Air cond works for 10-15 min. then pops circuit breaker.

\015 Circuit breaker pops earlier and earlier with each restart. It is a model 600312.331.\015

Answers :

Start capacitor, fan motor or the compressor is worn out. Most times its start capacitor. Thanks, Sea Breeze

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Air cond works for 10-15 min. then pops circuit breaker.


Start capacitor, fan motor or the compressor is worn out. Most times its start capacitor. Thanks, Sea Breeze ... Dometic Rooftop RV Air Conditioner

ON excessively hot days, the outside heat pupmp trips the circuit breaker. Most times it is only once, I turn the breaker to "on" and it works fine. Some days it pops two or three times. When the outside air gets cooler, it works fine. When the unit is operating, it appears to be operating normally (meaning cold air). I have not experience this during cold days.


Hello I would add a HARD START KIT to the run capasitor (if there is not one already).This makes the compressor come on easy.If the breaker trips during running time the pressures are too high,hose off the condenser coil (fins).The unit might be slig ... Carrier 38CKC036 Air Conditioner

I have a Duo-Therm, mod# 600315.321 on a motorhome. Fan motor overheats, but only after the compressor kicks on. New motor, swapped out caps w/identical working unit. Ground is good. Unit will run all day OK w/just fan, but when put on "cool", it will run and produce cold air for 15 min, the fan then quits. Compressor will run for 5 - 10 minutes more by itself, then the circuit breaker kicks.


... Dometic 57915531 Air Conditioner

My coleman Mach Rv air conditioner with built in heat strip keeps tripping it's internal circuit breaker when running for any length of time. Just replaced heat strip with new one experienced same issue. I ended up with the fan continuing to run but only cold air comes out of the vents! When I removed the old unit and reset the circuit breaker it too worked again. Have no idea what is causing this to happen. The airconditing part of unit works just fine??? HELP! Ron


There should be an overload protection device in series with the low voltage wiring(t-stat wiring) Is it resting on the heat strip or too close to it? It is a saftey device to shut off the heat strips if the fan quits or a fire in the heat strip sec ... Coleman Mach III Air Conditioner

MY AIR CONDITIONER WILL WORK GOOD FOR ABOUT 10-12 HOURS AND THE NEXT DAY I WILL AND CHECK THE RV AND THE CIRCUIT BREAKER WILL HAVE POPPED WHAT WOULD CAUSE THIS TO HAPPEN. IT COOLS GREAT. THANK YOU


Most likely the condenser is very dirty and the compressor pull more amps than is suppose to and when this happens the breaker tripps.start by cleaning the condenser with a design conderser cleaner. ... Dometic Rooftop RV Air Conditioner

Dometik Duo Therm Brisk Air rooftop trips AC circuit breaker when the weather turned hot. When circuit breaker is reset, the unit will run for 5-10 minutes, cooling nicely, and then trip the AC circuit breaker again. I changed the settings, but it did the same. Once the outside temperature went down, that evening, I tried it again. The AC worked fine all night and the next morning,and when it got hot outside next morning same thing, trip the breaker


... Dometic Rooftop RV Air Conditioner

OUr air conditioning system works well until the circuit breaker trips. We added another large return vent in the hall to try to get more air circulating and that didn't work. We just replaced the outdoor airconditioning unit and the circuit trips again. The electrician says the wattage is fine. Any ideas what could be the problem. Everyone is baffled because the house is only 5 years old.


Current (amps) is voltage (volts) divided by resistance (ohms) or I=v/r. Breakers "trip" when there is too much current flowing through them. ... Air Conditioners

I have a window air conditioner. When it runs for several hours it will trip the breaker. I have had the unit for 5 years. I bought it used and even though it has always shaken when the air compressor comes on it has cooled fine. Recently, however, my landlord changed the circuit breaker (had an electrician come out to do this and supposedly everything is working find). However when I pluuged the unit back into the plug for this circuit, the unit would not even operate for 10 mintues withou


It's probably fine even though it jiggles and makes noise. I would ask the landlord to change the circuit breaker again and ask the electrician what the amps were for the breaker he took out and the one he put in. \015\012\015\012Hopefull ... Whirlpool Air Conditioners

My bryant air conditioner will start and run for about 45 min. The fan stops and then the breaker trips. I wait for 30 min and re-set breaker and sytem works again for about 45 min. Is this a defective fan or capacitor?


Motor windings are over heating. Change the motor. ... Goodman CKL24AR24 Air Conditioner

I have a goodman CKJ42-1B air cond. unit. It keep tripping my AC breaker although continues to blow air - just not cool air. Once I turn OFF then ON the breaker the AC works fine for about a day. Then cycle repeats itself..Help.


Try cleani ng the unit outside with your garden hose first .sounds like its kinda dirty .the dirty er the coil is the higher the amp draw is when it is running .what size is the breaker in the box .thats a 3 an a half ton condensor ... Goodman CKL36AR36 Air Conditioner

I am thinking of buying a low btu portable air unit. A lot of them call for a single circuit. What does that mean? Most of my circuit breakers are labeled for a whole room. Would I have to re-wire? I have a 5000 btu window air-c & it works ok.


Hi,\012This means that they only want one outlet on that circuit, the one for the A/C....but if you are only running the A/C on a circuit and nothing on the other outlets you will be okay...they just do not want you to overload the circuit and ... Midea Air Conditioners

System works fine for about five minutes - blows well refrigerated air air, fan works great. Then the circuit breaker shuts it down every time. Could this five year old unit need recharging? On fan only, it operates well.


It sounds like it does need recharging, yes. 5 years is about average for such a system, if it is used fairly regularly during warm seasons... It could be the condenser portion has a circuitry issue as well, something causing a fault th ... Coleman Mach 15 Air Conditioner

Ruud Problems Hey Need help, I replaced the capacitor last night and it worked air was fine all night, but this morning it triped again. so I replaced the breaker switch and it started up again and the fan was running outside with air comming out of the vents inside. but breaker popped after about 30 seconds and cant get it back on!!! Only a buzzing noise comming from the system outside even with power off!!!! Any clue???


Compressor is probably bad. disconnect it tape the wires off and start unit. if breaker doesnt trip it is the compressor.  ... Ruud UAKA030 Air Conditioner

Hello, I have goodman 3 ton a/c that runs ok for about a half hour or so then the condenser stops running because the circuit breaker pops off. The a/c tech check the units draw ( 13 amps) and thought it was ok. We thought then it was a faulty breaker. We then put a new breaker (30 amp). Later same result. a/c works ok then trips breaker. Wait awhile then reset breaker and it runs again. What would cause the breaker to trip like that. Any ideas? Thanks


First of all, let me caution you to remove the 30 amp breaker and put back the 20 that was there. It's not to code. It's too big for the wire size. Second, you will need to monitor the circuit with a 'clamp on' amp meter to verify the current d ... Goodman CKL36AR36 Air Conditioner

B & D company air conditioner(model# 566DJ024-C) makes buzzing noise. I just bought a house and when I turned on the air...the unit outside makes a buzzing noise. The fans seems to work and cooler air is coming out of the vents(only ran it for a few min,didn't want further damage). I had the home inspected and the inspector said that the inside breaker is 30amps and the actual max for this particular unit is 25 amps. I don't know if that is the problem or something else...just thought I'd mentio


The circuit breakers Ampere rating has nothing to do with the buzzing noise. If you use a lesser Ampere Circuit Breaker it will trip every time the Air Con: starts, and if you use a very high Ampere Circuit Breaker it won't trip and give you the need ... Air Conditioners

I have a mitsubishi electric air system. It just stopped working for no reason. All units are not working. The remote work fine yet when you press the button nothing happens. This is all of the house. I tried to fix the circuit breaker, nothing. I tried the outside unit to turn off and on again, also nothing. Your assistance is greatly appreciated. Lisa Ablon


Hi Lisa,\015\012\015\012First change the batteries in the remote. Is this a central system or separate units. It sounds like central which would have sequencers and fan relay that would keep it from coming on. mi ... Mitsubishi Air Conditioners

Not working Neither the AC unit itself or air fan is working. Tried Circuit breakers and reset button.


If the indoor fan will not run it one of two things. Breaker to furnace or a bad 24v transformer.\015\012\015\012Thx\015\012RepairUSA ... Ruud UAMB Air Conditioner

We changed the AC unit from putting out cool air to warm air and several minutes later there was a loud "pop" sound and the whole thing stopped working.... I checked the breakers on the side of the unit and only one of the two were tripped. I reset it and still nothing... powere is getting to the unit. UBHC horizontal in attic. Thanks


Hi there,\015\012 it sounds there is short circuit when you switch on your ac,\015\012resulting to trip off,you can also check the over load relay on control panel,there is a lever to reset on thermal relay of the circuit\015\0 ... Ruud UBHC Air Conditioner

Air conditionerwon't turn on. It worked yesterday. Circuit breaker was tripped, I reset it but it still does not work


I would remove the cover on top and check for any wires that may have came off or burnt off. Next check for a fuse on the circuit board and check the condition of the contactor. Try turning the fan motor by hand to make sure it hasn't locked up. You ... Dometic Rooftop RV Air Conditioner

I have a Dometic Brisk air AC. Was working fine and all of a sudden the unitsounded like it went to half power. It will restart and sounds labored. It did trip the circuit breaker at the power source once. Reset the breaker and it continues to run labored, both on fan only and cool & fan.


There are a couple of scenarios that can cause this.1) Low voltage in the park. If the performance doesn't increase / doesn't sound normal this evening when electric demand drops off, see #2. If it does improve, you might try moving yo ... Dometic Rooftop RV Air Conditioner

Air conditioner The air conditioner & fan stopped working. The fuse at the circuit breaker panel is good. Is there a fuse or reset on the unit itself ?


There is a fuse inside the control panel of the AC itself. You have to take the cover off (from inside on the ceiling) and look up in there with a flashlight to find it. It is usually a very small amperage fuse - I think a 1 or maybe a 5 amp. ... Dometic Rooftop RV Air Conditioner

I just purchased a house that has a Goldstar air conditioner. I turned it on yesterday, and it worked fine. I left the house for an hour. When I came home the air was no longer on. I turned it off and tried to turn it back on and unplugged it and flipped the circuit breakers, but it still won't come on. Any suggestions?


... Goldstar R1804 Air Conditioner

Approx 2 years old. quit working during recent rain storm. have a backup furnace that kicks in when temps go below 35 degrees. new carrier thermostat (1yr old). furnace fan comes on blowing cold air, but heat pump does not come on. can go to e-heating and furnace works fine. no fuses on heat pump, no reset button and circuit breaker is fine. believe this is electrical, not mechanical. thanks


It sounds like the contactor is not pulling in . corrision maybe even a bug could prevent it from pulling. ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

When I turn on my air the compressor comes on and blows cold air. The unit runs for about 2 minutes then the circuit breaker trips. The coil has been cleaned and everything else on the unit works to include the heat strip.


Most likely your compressor is DOA, call a comapny and have them investigate further ... Carrier Air Conditioners

The fan on my duotherm a/c doesn't work. I can hear the compressor come on but the a/c doesn't blow any air. There was a fairly loud pop when it quit working. Am I looking at replacing a condenser or relay or circuit board or something else? Also the compressor will come on occasionaly when the furnace is on.


SOUNDS LIKE A OVER HEATED CONTROL SWITCH   THE SWITCH THAT CHANGES HIGH, LOW FAN, HIGH COOL, LOW COOL. REMOVE INSIDE CEILING SHROUD AND LOOK AT SWITH FOR BURNT TERMINALS OR LOOSE WIRES TURN OFF POWER FIRST AT BREAKER. ... Dometic Rooftop RV Air Conditioner