PAC L90 LT thermostat not working, unit icing over

\015 This happens daily. We have to dry it out with a hair dryer. I know there is supposed to be a theremometer that keeps ice from forming...how do we check, or replace it?\015

Answers :

No that would be either a dirty filter/coil ir low refridgerant if it's freezing in cooling mode.
\015\012
\015\012Clean/replace the filter, clean the coil and if it keeps doing it, have a technician who is EPA certified for servicing systems with refridgerant to look at it/add refridgerant.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

PAC L90 LT thermostat not working, unit icing over


No that would be either a dirty filter/coil ir low refridgerant if it's freezing in cooling mode.\015\012\015\012Clean/replace the filter, clean the coil and if it keeps doing it, have a technician who is EPA certified for servicing syste ... DeLonghi Pinguino PACL90 Portable Air Conditioner

Nordyne AC unit works at first but later provided cool air. Thermostat set to 65. Power running to unit outside. Noticed ice around line outside and can send a picture. Chipped ice away. Want to know what to do next.


If the inside fan motor is running OK you are low on refrigerant. If the inside fan motor is not running, repair the inside fan motor. Could also possibly be dirty inside coils. ... Air Conditioners

The outside compressor and fan will not shut off. I have turned the thermostat system to Off and even to heat, but it will not stop. I went on a trip, increased the room temp to 80 on the thermostat and left. When we returned 2 1/2 days later, the coils were frozen and no air was comiing through the vents, even with the blower motor working. So I turned the unit to furnace and melted the ice on the coils, but had to pull the fuses on the outside box to get the compressor to shut off. Is there a


Sounds like the contactor is stuck. That's why nothing will stop the fan and compressor except killing the power to it. You should be able to get one fairly cheap. ... Ruud UAKA037 Air Conditioner

My carrier air conditioner is not working. We have two exterior units. One for upstairs (smaller) and one for the downstairs(larger unit). That being said we have two seperate thermostats inside our home. The upstairs unit is working fine. The downstairs thermostat shows on Auto that the unit should be kicking on based on the temp. However, the outdoor unit for downstairs is not working. So far I have checked the downstairs vents and they are blowing air although not very cool. I also tu


Hi,The problem is in the outdoor unit...The compressor could be locked up, the condenser fan could be bad... or from what you are saying the contactor for the outdoor unit is either not pulling in or is bad...that also can be a result of ... Air Conditioners

Have a pac L90 and behind the filter it develops ice buildup after running for about 1 hour. Cleaned filter but problem is still there. Have used this unit for about 2 years


I have the same problem and mine is the same age. I think it's low on freon but no one near me works on them so I'll never know for sure. ... DeLonghi Pinguino PACL90 Portable Air Conditioner

My unit's compressor will intermittantly stop working. The thermostat seems to keep the intake unit working but since it can't get the temperature down it never shuts off. We have been removing the batteries and letting the thermostat reset for 20 minutes. (thermostat Honeywell RTH23110B). After the reset the compressor will work again but will fault within a day. I am pretty sure that the compressor and fan are functional as if I press the contactor down it begans functioning. I also, to he


If the air handler coil is clogh , the air won't go through and the compresor will shut off on overload because of high head pressure, also this will happend if the condenser coil (outside) is blocked or if the fan dosn't work .Also if the outdoor un ... Air Conditioners

I have an intertherm rpbmb030k combo a/c and heat. Had frion put in the unit over the summer and a new digital thermostat. Unit has worked great until we needed heat. Unit works great on aux. heat but keeps switching to to defrost mode when standard heat is on. Switched out the defrost board on the unit to no avail and an a/c guy checked to ensure the new thermostat was wired correctly.


Hi, if the unit had a leak in it, was the leak located and repaired? Did he check the pressures in the unit now? If it switches to the aux mode ( Heat Strips ) is normally caused when your primary unit, compressor and freon are low on charge. I would ... Intertherm P3RA-060K Air Conditioner

Air conditioner for a fleetwood bounder 1997, i here a click at the thermostat but unit will not go on i also have a unit in the back of the coach that works fine both units work off of a monitering shed light thermostat. what do u think my problem is?


... Air Conditioners

Honeywell central heat & air unit--wall thermostat not controlling it--will not work--thermostat only lights up -aux- and screen goes blank...worked previously...replaced relay and thermostat---still same thing. Why would the thermostat just stop working?


... Honeywell ER150B Air Conditioner

Goodman hvac unit not working no power. touchscreen thermostat not reacting to touch unless pressed very hard. swapped thermostat faceplate with downstairs unit and it works fine. No power for a/c or furnace. Fusebox shows all power is on and emergency switch is on. What could be problem?


As I said, bad t-stat.When you switched covers it worked correctly. The t-stat sends a signal through the fuse then to the components you are calling for.The original t-stat blew the fuse and is hard to push.Replace your t-stat and ... Air Conditioners

Still working on our ac inside unit Coleman EB20B outside unit Goodman CKL49-1. We had a short in the thermostat wiring that we repaired. Now the AC is working when the fan switch is on run. It doesn't run with the therm switch on the cool cycle. Have we crossed wires somewhere or is our thermostat bad? Thanks Ken Rohm


You could have either situation. You could also have a bad thermostat sensor, as it talks about in this blog:\015\012http://hubpa ... Coleman Air Conditioners

I have a suburban lp furnace and duotherm air/heat pump roof unit. duothern thermostat. 20 amp breaker kicked ( reset breaker) & furnace quit. NOW furnace fan comes on but does not light, and the front AC will not work either, when in the COOL position on STAT the unit blows warm air instead of cold. I replaced the Thermostat and a Tech guy checked the board in the furnace and it was OK. He also switched the board from the rear air with the front and nothing changed. Rear air and heat pump works


I'm not sure what the problem may be but you could try calling All\015\012Seasons RV Appliance Parts & Service. There number is\015\0121-800-344-0673 they have helped me in the past. That and there tech\015\012calls are free so it wouldn't hurt ... Dometic Rooftop RV Air Conditioner

I have a Rheem Gas Furnace with an old analog thermostat (Wires conneected to terminals R and 4 for the thermostat). I went to install a Rheem digital and programmable thermostat and it indicated that it would not work for that wire configuration (Instructions indicated that the thermostat would not work with wires to the #4 thermostat terminal). Is there a setting on the furnace circuit board I can change, or is there a digital, programmable thermostat one can use on this unit - Model RGDJ 12EA


If you have 2 wire at thermostat Terminals at furnace that the thermostat wire attach to should be R & W if your new thermostat has R & W terminals is should work, an easy thing to remember is the red wire on R the white wire on W. If 4 wire ... Air Conditioners

I have a U-42 Janitrol gas furnace that will not start the exaust fan nor will it light the burner but the blower fan will come on. I have two identical units. I've swaped the exaust fans and the unit that was working strarted the other exaust fan - put the known working fan in the non-working unit and it still didn't come on. I switched the thermostats and still no positive results. Any suggestions?


... Air Conditioners

There is a switch on my 1 1/2 ton Ruud furnace/Air handler that is not working properly. The unit would not turn on, even though the thermostat was working. I took the panel off of the air handler and found that a switch had been duct taped into the on position on the unit. Apparently, the tape had shifted and the switch was no longer in proper position. when i moved the switch, two green indicator lights lit up. When i turned the unit back on, the A/C worked. Clearly, there is a problem w


Helllo, this switch is called a door interlock switch. ... Air Conditioners

Suburban sf30 rv unit.. I had a new board and limit switch installed. The service tech said it was working. I marked the wires when I removed the unit. I re installed the unit conecting the wires the same as when I removed the unit. I have 2 blue wires, 1yellow and 1 red coming from the furnace. There are 3 thermostat wires 1 grn, 1 wht and 1 red---The power source are 2 solid white wires and 2 blk and wht striped wires, there is power to the unit. I am at a loss as to why it will not work. T


... Dometic Rooftop RV Air Conditioner

Thermostat inside home is completly blank and unit not working


If you dont have a lock on the service disconnect sometimes kids will pull the service shut off down. Or you can check the service disconnect Usually theres fuses in there that can blow. The breaker box can also be checked to see if it's tripped or n ... Ruud Matching Split Air Conditioner

My American Standard Heritage 11 unit was not working properly when i came home from work and the temperture in the house according to the thermostat show the temperture in the house to be 85 degree&#


The dual run capacitor is bad located in main panel of unit size of small red bull can it will be swelled up on top indicating it bad get on at electric motor or electric supply house most ac stores wont sell it has a rating like 35/5 370 ... Air Conditioners

I have a goodman gsc13 ac unit about 4 year old. When the temp gets around 90 or above outside the fan on the unit starts but the compressor does not. I had service check it out but that day they were here it was in the 80's and it worked fine. I replace the thermostat to make sure that wasn't the problem. Interesting if I turn the unit off at the thermostat and wait 15 minutes and turn it back on it will run fine. But the next time it tries to turn on automaitcally it will just be the fan o


The hum you hear is the 24v transformer which is powered form the air handler inside have you tried a hard start kit or had cap checked ... Air Conditioners

I have a Tempstar model NFCP3600A1 (style # FCP3600A) ICP Heat Pump. Starting last week, the unit kept heating well over the set temperature. I swapped out the thermostat thinking it went bad, but it still continued heating and the "off" wouldn't work at the new thermostat either. Next, I checked for shorts in the thermostat wires and they seemed OK. I then replaced the TI 26FC-2 circuit board. Once the unit heated the house to the set temp, it continued running up to 75 degrees. "Off" and lowe


... Air Conditioners

Have a Bryant 340MAV condensing gas furnace. Installed a new thermostat for the A/C unit middle of summer (old one slowly died). Woke up this morning to no heat - thermostat didn't automatically kick in. Programmed it manually to kick in; fans work just fine and the unit is cycling, with thermostat reading heat. But furnace won't won't heat.


Just curious, have you changed your filter out recently? This blog talks about a problem similar to yours and the tech changed out the filter and tapped a screwdriver between the terminals of the limit switch:\015\012 ... Air Conditioners

My thermostat on my ac keeps resetting itself to 86. i can turn it down then it goes right back up. it is a window unit about 2 yrs. old. i keep trying and eventually it starts working again. works for about a day then does it again..the buttons dont seem to be working right on the unit when it is acting up either.


... GE AJCQ08ACB Air Conditioner

Carrier thermostat Hello, My Carrier electronic thermostat is connected to a heat pump.  It was set to the COOL position during a summer thunderstorm when the AC suddenly began running no matter what the SET temperature was.  It works normally when I change it to the AUTO position.  The HEAT and EHEAT positions work normally. I tried cutting power to the unit for 2 days, after which it worked normally even on COOL, but after a short power failure it resumed the problem of running the AC continuo


I hate to say it but Ive had trouble with Carrier's Tstats doing similar improper things. Unfortunatly the only repair is going to be replacement of the whole tstat. I recommend Honeywell's FocusPRO or VisionPRO tstat. Ive yet to have one fail and th ... Air Conditioners

Our Carrier 38ckc036350 is not working - the outdoor unit was very hot to the touch and will not turn on -turned it off at the thermostat - later when the unit cooled down turned it back on via the thermostat and it would start to kick on, but then stop - no breakers were thrown. Unit will be 7 years old in the middle of July '10 and am wondering: 1. what could the problem be & 2. will any of this be under warranty?


The first thing I would check is to see the condensing coil is clean. Take a garden house and wash it thoroughly. If it is severely clogged you may need to remove the top and clean it with water pressure blowing from the inside out. This may stop the ... Carrier 38CKC036 Air Conditioner

This is about a 15 YEAR OLD Trane XE1000 30,000 BTU A/C unit. The A/C was not working, but right after I called to have someone come fix it, it started working again all by itself. When the unit was not working (for about 18 hours). The house got up to about 80 degrees with the thermostat set on 70. When the HVAC tech got here (next day), he told me the compressor is shot because the thermal limit switch inside the compressor is overheating. The area where the thermal switch is getting warm, but


You can wait just buy a capaciter start system theat will override the old start capaciter, this is a common problem for all ac systems. just bu the ac start replacement and yo should be good to go for a couple more years. and if you want a reference ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1565 seconds