Having problems with your Air Conditioners ?

Will not blow cold air through vents - Goodman Air Conditioners


Answers :

If only blows air at room temperature you may have aproblem with the condensing unit outside

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Will not blow cold air through vents - Goodman Air Conditioners


If only blows air at room temperature you may have aproblem with the condensing unit outside ... Goodman Air Conditioners

I have a 2004 Chevy Tahoe with dual zone air conditioning plus rear air conditioner. My problem is on the 2 driver vents only it keeps going from cool air to hot air. After you drive for a while it is all hot air coming out of these 2 vents. All the other vents (passenger & rear vents) are blowing cold air.


If the truck has a dual zone temperature control in the center console then this is most likely your problem as alot of times when these go bad the think the driver side is too cold and turn the heat on to warm it up thus giving you warm air through ... Air Conditioners

How do I know if compressor of my house air conditioner is turning on when I start my air conditioner? When I start my air conditioner the fan outside the house turns on, the air is blowing from the vents in the house but the air is not cold at all.


If the compressor is starting there will be a very small dimming in the house lights,if you go outside to the unit and start it from the outside disconnect when the compressor starts you will hear a whine type noise coming from the outside condenser ... Air Conditioners

Goodman air conditioner model #PC036-1a; when you put on heat the unit kicks on and blows out air with no problems but when you try to turn ac on, you can hear the motor click on like it's trying to start but no air blows out of the vents. thought it might be the relay switch? any suggestions


Try replacing the control board most the time its a relay stuck open for high speed on your fan ... Goodman Air Conditioners

Air conditioner The fan blows but there is no air, cold, blowing out of the vents. What may be the problem. And is it a quick fix?


Filters blocked or fan cage full of dust cant pickup the air if this is a zoned system then maybe zone damper is stuck not letting the air through ... Sunpentown WA-1210E Air Conditioner

Amana central heat and air unit use to blow cold air through all the vents. Now the 2 hardest blowing vents close to the air handler barely even blow out cool air while all the other vents still blow very cold air..Any idea or help as to what may be going on is welcomed..Thank u.


Visually inspect the duct run connections to the main trunk. It is possible that they have loosened and are losing air under the house. Also inspect the duct runs from the trunk connection to the vent connection. You want to check for any damage or o ... Air Conditioners

Rv air conditioner how cold should the air blowing from ceiling vents be?


Do you have two rooftop a/cs, ideally any a/c you like to see temps from the inlet duct to the outlet vent at least 15-20 degrees difference in temp,check your filters,that front air works twice as much as the rear,plus cooking and heat load on it ca ... Air Conditioners

Sometimes, our furnace will start blowing cold air when it should be blowing hot...I know it is normal that it blows hot air and then will blow cool air as it cools to shut down. This is not what I am talking about. I am talking about while the furnace is blowing hot air to heat, it will quit blowing the hot air and start blowing cold and it it like the air conditioner kicks in. It will then continue running cold air...I usually have to shut the furnance off and when it kicks back on it will


Do you have an automatic change over thermostat? this would switch it from heating to cooling. ... Air Conditioners

Air condition not blowing cold air - Goodman CLJ36AR42 Air Conditioner


Large copper line coming from outdoor unit should be cold,If not you need recharge or compresser is turning on. ... Goodman CLJ36AR42 Air Conditioner

Air conditioner not blowing cold air


Just because the big one is cold and the small one is warm,Doesn't tell you if the system is properly charged or properly working.It is true that the big line will be cold and have condensation on it and the small one will be hot and dry,But this occ ... Goodman CLJ36AR42 Air Conditioner

I bought a haier electronic control air conditioner model HWR10XC6 on 6/30/08. I installed it. When I try to use the cool mode the air conditioner will only blow out cold air for about 5 - 10 minutes and then it just blows out regular air as if its on fan. I did what the manual said to do and it still continues to do this. I can't get it to blow out cold air for a longer period. Its getting really hot in here.


Hi,\015\012 It sounds as if the compressor (that provides the cooling) is cutting out due to either a faulty thermostat or is itself overheating.\015\012\015\012Obviously check the thermostat is able to move between it's minimum and ... Haier Air Conditioners

The blades on the air conditioner are not spinning, air is blowing from the vent but it is not cold


Hi, \012 \012Here is a tip about troubleshooting your air conditioner...\012There are many things that can cause your air conditioner not to cool… ... Ruud Matching Split Air Conditioner

My Haier HPMO9XC5 Portable Air Conditioner is running and vented properly but the air it's blowing is not cold. Can anyone help?


Need service tray to clean the inside of the unit ... Haier HPM09XC5 Portable Air Conditioner

I have a 3 ton goodman heat pump warm air is delivered from all the vents except for two which blows cool to cold air . help me , freezing im both bedrooms


If these are the longest runs from the air handler this can sometimes happen ,about the easest solution is to install a in duct heater into the duct feeding the rooms this is basically a set of electric coils installed in duct to re-heat the air goin ... Goodman CLQ36AR49 Air Conditioner

Goodman gas pack blowing cold air - Air Conditioners


... Air Conditioners

I have a CPN12XH9-E and have disconnected the vent for the air conditioner and want to use the heat. I know the sun icon is for heat but how do I stop cold air blowing out the back exhaust?


... Haier Air Conditioners

My Goodman CKL36-1L air conditioner unit is heating up on the coils badly and is not running properly. No cold air pushing out the vents. Why is it heating up?


... Air Conditioners

We are selling our house and have been leaving the air conditioner on for the last several days at 70. It has been keeping the house cool for visitors when we are at work. Yesterday I came home from work and the house was warm. I checked the air conditioner and it felt like it was blowing just air. Checked it throughout the night and still blowing just air, not cold anymore. I am thinking it ran out of coolant. I am not an expert or know anything about air conditioners. If you could give me your


It can be many things like a loose connection. It can be low of refrigerant or it can be the condenser fan has stopped working. Considering you are selling the house just call a qualified HVAC repairman and have it repaired. ... Air Conditioners

I have a frigidare FAM157S1A Air Conditioner, when plugged in the fan blows air but not cold air. Compressor not working, I pushed control panel to cool air, blows cold air for a few seconds, then unit blows the breaker. How do I fix it. It has been only used for two weeks and this started.


Your compressor motor is no good Time to replace unit ... Frigidaire FAH085N1T Air Conditioner

My turbo air conditioner will not blow cold air. We had freon added and checked for leaks. When they added the freon it blew cold air for about 10 min. And stopped blowing cold air. What could be the problem?


... Turboair TAS-24H Split System Air Conditioner

Sharp 10000 BTU 38db portable air conditioner blows cold air for 2 minutes then blows warm air for 5 minutes then turns off for 20 minutes then repeats this process. How can I fix this problem to blowing only cold air? The filter is clean, water is drained, good ventilation.


Sounds like the unit has a low charge and is cutting out on a low press safety. This is more then likey not something you can fit yourself most of this units are not really serviceable with out cutting the lines open and adding a valve. If the unit i ... Air Conditioners

NOT BLOWING COLD AND UNIT FREEZING - Goodman Air Conditioners


Dirty filter or low on freon ... Goodman Air Conditioners

Hello - I have a heater/air conditioner; when I run the air conditioner it blows water and leaks water into the house. I was told by an air conditioner technician that I need to replace the unit; however it blows super cold air the only issue is that it leaks water. Not sure what I can do? It is a Fredrich Twintemp Model#EL25J35-A Cooling BTU/AR 24600/24000


When the filters, or heat exchanging coil, are dirty or blocked, this causes a restriction in air flow. This in turn can then cause the temperature of the coil to drop. If the coil temperature drops below zero, moisture in the air that is ... Friedrich Air Conditioners

I have a Jayco trailer with a Coleman 7300 Rooftop air conditioner. The unit is 13 years old and it doesn't put out the cold air it used to. I have cleaned the filter which improved the air flow however still not blowing cold air. Is it time to replace the air conditioner or is there something I can do to fix it.


Hi,from your problem its obvious that the problem is from the compressor.its bad and needs a replacement,however this requires the services of a technician and it will cost you a lot of money,however in the nearest future another problem may arise fr ... Coleman Air Conditioners

I have a Danby DPAC10030 air conditioner. It was working fine until yesterday, when we moved it to another room. Now it blows cold air for 5 minutes and then the air turns hot. The a/c motor continues to run even though the air is no longer blowing cold air. The current ambient temperature is 25 degrees C and I have the a/c set to cool to 17 degrees C. The timer has been turned off (0:00 on and 0:00 off). I noticed that the hoses (exhaust) feel quite hot. Not sure if that it normal within


Clean you filter and clean the area under the intake duck it will solve your problem ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific