The furnace is blowing warm air even if the thermostat low.

\015 The furnace will not shut off unless you trip the breaker to the off position. I had not used the furnace in several weeks until this past weekend. It was working fine when I cut the furnace on and then later in the night the heat cycled on and stays on blowing warm air the termostat was set at 68 degrees with the blower set to Auto setting. The trailor home reached 80 degrees untill I had to cut the furnace off at the breaker. Can you please advise where I should start or is ther termostat bad. Thanks, Mike\015

Answers :

The only thing that tells the unit to come on and off is the thermostat so I would definatly say it is it. When you turn the system back on, does the a/c run normally? If it does, then it's the problem with the heating side of the tstat. Also, does the fan come on when you put it to on and then turn of when you switch it back to auto? If it does, then the system is working fine, its the t-stat. Let me know if you have any more problems.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

The furnace is blowing warm air even if the thermostat low.


The only thing that tells the unit to come on and off is the thermostat so I would definatly say it is it. When you turn the system back on, does the a/c run normally? If it does, then it's the problem with the heating side of the tstat. Also, doe ... Intertherm P3RA-048K Air Conditioner

I have a white rogers thermostat, it wont click on automatically when it is colder in the house than i have the heat set on. furnace just pops, fan does work and does blow hot air when i turn it to on. i have a digital thermostat. i reset all the programming for it, even turned it off and turned off the furnace with 2 breakers at the bottom of the furnace but still nothing. The furnace is warm like it is trying to kick on


Did you connect the jumper wire to rc---rh on the thermostat? ... Air Conditioners

I have a suburban lp furnace and duotherm air/heat pump roof unit. duothern thermostat. 20 amp breaker kicked ( reset breaker) & furnace quit. NOW furnace fan comes on but does not light, and the front AC will not work either, when in the COOL position on STAT the unit blows warm air instead of cold. I replaced the Thermostat and a Tech guy checked the board in the furnace and it was OK. He also switched the board from the rear air with the front and nothing changed. Rear air and heat pump works


I'm not sure what the problem may be but you could try calling All\015\012Seasons RV Appliance Parts & Service. There number is\015\0121-800-344-0673 they have helped me in the past. That and there tech\015\012calls are free so it wouldn't hurt ... Dometic Rooftop RV Air Conditioner

Furnace blows warm air for less than a minute...not enough to get even close to temperature thermostat is set to, and then shuts off


If the furnace is lighting and the fan is coming on, but then goes out before the thermostat is satisfied, you definitely have a problem with a safety interlock on your furnace. It could be as simple as the flame sensor not being inside the flame wh ... Air Conditioners

Intertherm furnace circulating air doesnot get very warm furnace butas soon as air getswarm it shuts off . house does n ot get very warm even if furnace runs all day.


That is a stack limit switch. You are not venting properly. Is your unit power ventilated or gravity fed? ... Air Conditioners

My thermostat inside my house will not shut off, runs constantly now, on both a/c and heat cycles. Does the thermostat need to be replaced?I have central air and heat. Recently tried to shut off the heater one morning , had warmed up outside and was too warm in house. I could not get the heater to shut off even manually. finally tried turning on the a/c, it came on but it would not shut off later when it reached temperature set even when I manually tried to shut it off. My outside unit (a/c) is


Hello\015\012IF this is a programable stat.Take the batteries out and replace them.\015\012Then reprogram the stat.\015\012\015\012IF this is not programable have the wiring checked at the unit and the stat.May need to replac ... Air Conditioners

I have installed a UPM model THM101B thermostat on my Intertherm model E3EB-015H electric furnace. I wanted the feature of turning the blower "ON" without the heating elements. I picked up the green 12v for the fan relay. Once the power is restored the furnace comes on even though the temp setting is low and the only way I can turn the furnace off is by disconnecting the green fan relay wire? The jumper has been properly set in the new thermostat for electric furnace operation.Right now I feel t


... Intertherm Air Conditioners

I am trouble shooting a Bryant Hi-bred system that uses an air cooled heat pump with high efficiency gas furnace for backup and low ambient operation. How does the system decide whether to use the air cooled heat pump or the gas fired high efficiency furnace. It appears to be outdoor air temperature related, but I can't find the setpoint for it. The main zone Bryant thermostat appears to control the system, but it doesn't always bring the backup heat if the heat pump doesn't function.


If you are using honeywell vision pro 8000 t-stat you need an outdoor sensor program on t-stat would have to look up ... Bryant Air Conditioners

I have a goodman furnace and air conditioner. When the air conditioner is running, it runs for about 10-15 minutes, then shuts off for about 5 seconds, then restarts. Could you tell me what would be wrong? I think also associated with this problem, when the heat is running, the furnace will run for about an hour, then shut down, even though the temperature has not been reached. Resetting the breaker, or depressing the reset switch in the thermostat will start the furnace running again. A third p


Try running viniger through it , clean or replace filter , if filter was real dirty you may want to have your evap coil cleaned ... Air Conditioners

Central air just stopped running, was running all day. I turned down the thermostat about an hour ago and I heard it come on. I noticed it wasn't running just a little while ago. Looked an the thermostat says it is 78 while the aircon is set for 72. It wont come back on I tried resting the thermostat and checking the breakers. I even switched the furnace off on the side. The furnace is about 30 years old...


Possible you have a bad contactor switch.. Have a tech look at this since it is dangerous due to high voltage and age of unit\015\012\015\012Good Luck\015\012\015\012Dave ... Air Conditioners

Over the summer we shut our thermostats off so that our furnace would not turn on since the weather was beautiful. But we noticed that our heaters in our downstairs part of our house were warm. The furnace did not sound like it was on, but for some reason, the heaters were emitting heat. In order to stop this, we had to manually shut off the valves on the furnace. This stopped the heat from coming out of the heaters. But now that it is fall, I have the thermostats on and even when the tempera


Do you have a water heating system? ... Air Conditioners

The outside compressor and fan will not shut off. I have turned the thermostat system to Off and even to heat, but it will not stop. I went on a trip, increased the room temp to 80 on the thermostat and left. When we returned 2 1/2 days later, the coils were frozen and no air was comiing through the vents, even with the blower motor working. So I turned the unit to furnace and melted the ice on the coils, but had to pull the fuses on the outside box to get the compressor to shut off. Is there a


Sounds like the contactor is stuck. That's why nothing will stop the fan and compressor except killing the power to it. You should be able to get one fairly cheap. ... Ruud UAKA037 Air Conditioner

Why does the heating element in my gas furnace keep shutting off before it reaches the desired temp? The fan keeps blowing but the air is cold. I have to turn the thermostat to off, wait a few minutes and then move the thermostat button to HEAT again. It will not consistantly blow warm or hot air. Thank you


The furnace has many safety controls monitoring many parameters. The most like cause of your complaint may be low air flow. The most simple reason would be dirty or too restrictive of an air filter. If the filter is clean that is about as far as you ... Ruud UBHC Air Conditioner

My Carrier Quietline air conditioner (model number 50DV002700-03) only blows only luke warm air even when the thermostat is turned as far as possible on heat. It cools OK but heating is poor. I was wondering if the thermostat is on the blink . Do you have any suggestions? Thank you Martin


... Carrier 38CKC042 Air Conditioner

2 weeks ago one of my units stopped working properly. It got warm during the night even though I heard the unit running. I shut it off and called for repair service. They changed the thermostat and it worked again,until 2 night later same thing. I called another repair service and he found that it needed freon. For the last 2 weeks it has been cooling fine even with Fla.hot temperatures of 85-90 degrees. Last night same problem unit running and not putting out air thru the vents. Shut it off for


Sounds like the coils inside the air handler/furnace are freezing up. likely cause is the freon charge is incorrect (probably undercharged). it may have been correct when the tech did the work but some may have leaked out. it is slightly possible too ... Goodman CLJ36AR42 Air Conditioner

Townhouse has an old slide, mercury bulb thermostat. Our furnace is now cycling and the flame only takes a few seconds before it turns off again. Most of the time it just blows cold air. Last year we adjusted the anticipator higher and it worked fine. Now, we adjusted it to an even higher number and it still cycling on and off. 1) Right now I think the value is at .4. What is the correct value setting for the anticipator. 2) If I replace the thermostat with a digital (Honeywell RTH221B), w


Hi\015\012i will suggest to replace to an energy efficuect t-stat.\015\012that will solve your problem and will save you money\015\012\015\012more info\015\012 ... Air Conditioners

The temperature sensor is reading low (temperature set all the way to 65F) and the air conditioner compressor is not running. The compressor comes on if I hold the temperature sensor bulb in my palm to keep it warm. Can I replace the thermostat? Is the part number CWA15105? Is the temperature sensor part of this thermostat CWA15105


... Panasonic CW-1406BU Air Conditioner

Intertherm electric furnace model e2eb-012ha is blowing only luke warm air. I have checked thermostat settings and air filters. Need help on next steps.


... Intertherm P3RA-042K Air Conditioner

My duo-therm forced air direct vent furnace will not stay lit. L-342465, model 65930-064. When I turn on the thermostat, I hear the fan, but then it starts clicking. Like it's trying to start. Sometimes it does & I feel warm air coming thru the ducts. But not all the time. It's in a 1983 Aljo 5th wheel trailer that I live in. Please help. It snowed this morning. Thank you, Brenda


I currently have the same problem. It's happened before and it was the circuit board on the right inside of the heater. Tired of that board going out ($) several times, so this time I'm going to remove the board and look at it myself for any common p ... Air Conditioners

My upmc-030jaz runs continuously, it will be warm air for 20 mins then cold air for 2 hours, thermostat stays at the same temperature....or even declines a few degrees, but when reaches desired temp it will not shut off...techs have been here 5 times and keep replacing compressors...getting rather expensive....HELP! =(


... Ruud UPMC036 Air Conditioner

Amana gas fired warm air furnace. Blower (fan) works fine when thermostat set simply to "fan". When selector is moved to "heat", burner fires nicely but teh circulatior blower fan does not kick-on. Any suggestions?


Either bad run cap on motor or bad blower motor ... Amana Air Conditioners

I have an electric furnace and heat pump that will at times blow only cold air during the heating season. I have checked the filter and don't believe that to be a problem. I usually have the temperature set to 74 degrees. When the outdoor temp. is extremely cold the axillary heat indicator will be on and still no heat. I can turn the heat pump off by switching to emergency heat and will get some heat from that but not as warm as I think it should be and even that will at times only blow cool


You are losing operation to your heat strips.\015\012\015\012In heat pumps, there is a secondary heat source. Usually electric heat strips. (Sometimes a gas furnace, this is known as a "dual fuel" system)\015\012\015\012The he ... Carrier Air Conditioners

I have a Carrier Gas Furnace Model # 395CAV024055ABJA, I works fine if you keep the temp low, like 68, so that it doesnt come on very often, but if you try turning it up and it needs to run for awhile, it wil start this cycle where the flame will kick on and off, the blower is continously running and only blowing cold air, I have tried new batteries in the thermostat on the wall, and have tried putting it on manual heat, no change, another thing is that once it starts this cycle, if you shut it


It sounds like it is going into overheat mode. Check the overheat sensor, make sure the flue is clean, make sure any filters are clean, also check the gas passage inthe heat exchanger, if there is a blockage from soot the system will overheat ... Carrier Air Conditioners

Our furnace runs great all day, but at night and early morning it stops. The house drops 5-6 degrees between 2am and 8am. If I try to adjust our thermostat, it will kick on and only run for 1-2 minutes (blowing warm air).


Hello\015\012Sounds like the t sat may be faulty or have a bad anticipator,usually there is a 2 to 4 degree swing before the unit will start.\015\012\015\012Also have a look at the location of the stat is it very close to anything g ... Weather King 10AJA4201AH Air Conditioner

Hello, mt name is Tony. I really need some expert advice! My electricity had gotten disconnected awhile back, well when i got it reactivated my furnace nor central air unit would not work. I had someone come look at it a couple weeks ago, he told me he thought it was the thermostat. So I went to Lowes and picked up Hunter model#44860, (i guess thats what i needed because i have a heat pump). I installed it myself and I'm not sure if I have it right because I still have no heat. Ther wires from t


Black C and Brown to W-2. ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific