Blower motor wont shut off

\015 I have a lennox consevator G8E, im not sure how old it is. The blower motor will not shut off. I tried shutting the main power off to the unit and it shuts off but as soon as you turn the power to it back on the motor starts running again. The ignition system works and it will pump heat out.\015\012Thanks\015\012\015\012Andrew\015

Answers :

Turn the fan to the off position on the tstat. You colud have a ilimit switch or a relay on the control board if it has one.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

My goodman cental air system is having problems. First, the blower inside (furnace) keeps running for hrs after the outside condensor shuts down. Now, the condenser blower motor wont operate at full speed. I have replaced the motor and capasitor with no changes. Can anyone help with these problems???


The cause of your indoor fan running all the time or for long time after your heat pump has stopped heating is the fan delay relay. It has welded its internal contacts together. If you take off the side below the control panel, the fan delay relay ... Goodman CLQ36AR49 Air Conditioner

Blower motor wont shut off


Turn the fan to the off position on the tstat. You colud have a ilimit switch or a relay on the control board if it has one. ... Air Conditioners

Blower motor on a/c wont shut off, what can I check?


Hello, take the thermostat off the wall and disconnect the wires, if this turns blower off you have a bad thermostat, if it does not turn it off you have a bad control board. ... Amana Air Conditioners

Blower motor relay switch problem I have a weather maker 8000, everything works fine but blower motor wont come on, just a click, and after it does not come on the the furnace stops, is this a blower motor relay switch, and if so, where is that located to replace? thank you, scott.


Hello, if this is a electronic ignition Furnace the relay is located on the intergrated control board. The only problem is that you cannot replace only the relay on those boards, the whole board must be replaced. ... Air Conditioners

Recently replaced blower wheel and blower wheel motor mounts,that problem was solved but now fan motor for the compressor runs non stop-wont shutoff except by breaker box.also changed thermostat at the same time.have i inadvertinly placed the wrong wire terminal in the wrong recepticle in either the blower motor or thermostat? If so,which one and where?How can it be fixed?The unit is a 1973 coleman evcon.


First question first, NO! this is a simple problem and a common one to fix, just change out the outside contactor coil, the contactor has a thin layer of silver on them to prevent them from arching and sticking together, over time this thin layer b ... Air Conditioners

BLOWER MOTOR IN HEATING FURNACE COMES ON WHEN AC GOES ON THEN SHUTS DOWN DO I NEED TO CHANGE BLOWER MOTOR??


... Ruud UBHC Air Conditioner

Hi, just replaced the capacitor thinking that would solve the problem but it appears it did not. The motor outside would kick on the unit inside would kick on but the blower motor inside works sometimes and wont other times. Basically, the unit will work just fine all day then we notice the house is getting warm, check the inside unit and everything is running fine but the blower motor is not circulating the air. I have a goodman a30-10 unit. I read where some people said the relay could be bad


Turn off the power to the air handler(indoor unit). Remove the access panel. From the motor,trace the wires back to the fan relay. One wire will probably trace back to the incoming power terminal. The other is the fan relay. It could be intermittent ... Air Conditioners

Carrier oil furnace model 58BMA155-20(FORCED HOT AIR)i had changed the blower motor & honeywell st9103a128 fan control board.now the blower motor won't shut off until the breaker is turned off.i disconnected the thermostat an it's still the sameway.fan control board was replaced with a honeywell st9103a1002 board.blower motor was replaced with a 3/4 hp universal motor.i also have central a/c.


To have your work constantly the fan or the board has a problem communicating with the new fan or if outdoor ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

I need a wiring diagram for an armstrong gas pack, the model number is 125GRTC421A2. The draft motor starts and the burners light, but the blower motor wont start. The blower motor does start if I put the unit into cool mode.


... Air Conditioners

I have a heil -- model NUGK100DH12-- problem is when power is supplied to it the blower fan comes on right away along with the induction blower and it does have the electronic pilot which all works to thermostat setting. when setting is reached the flame shuts down normally and I think the induction motor cycles correctly, but the blower motor never cycles off. It's on constantly. I tried replacing the fan relay to no avail and am considering replacing the timed fan controller as the next move


... Air Conditioners

Blower motor Can I buy a 1/4hp blower motor for a rheem unit the blower bearings are shot it wont turn it bearly spins


Yes you can!! ... Air Conditioners

Blower motor I have a UBHK 25J21SFE. The blower motor will ramp up and then shut off. It repeats this over and over. I have replace the ECM Interface board and still no change.


Hill, which blower motor? The exhaust inducer or the room air blower? If you are referring to the exhaust blower, check for a restriction in either the fresh air inlet, exhaust pipe or condensate line. If you are referring to the room air blowe ... Ruud UBHC Air Conditioner

I have a new CMF2 80-PO convertable the blower comes on with the heat but sometimes shuts off and on and on the cool down it will run for 2seconds and shut off and 1 second later the same thing what is the problem? should the blower run longer it sound like the motor will not last long if it keeps working this way.


... Coleman Intertherm Nordyne Miller Furnace Control Board 904531

Sometimes, when the inside blower shuts down, the outside compressor and fan motor continue to run for some time. Other times, when the inside fan motor is running, the outside fan and compressor motors are not ... if I press the outside reset button, it starts up When both inside fan motor and outside fan and compressor motors are running, it works fine ... warm air blows out of registers. Other than that problem, both units work great!


Sounds like you have a dirty condenser. You are going to need to disconnect the power at the outside unit on the wall by pulling the fuse block out. Take a good look at the louvered covers that are attached to the outside of the unit. Remove the scr ... Ruud UAKA060 Air Conditioner

Blower motor will not shut off


Hello, sounds like the relay on the integrated board is sticking. The only option is to replace the whole board. ... Air Conditioners

WEATHER KING GAS FURNACE . BLOWER MOTOR COMES ON INSTANTLY ON CALL FOR HEAT AND WONT SPARK IGNITE.


... Air Conditioners

Blower fan motor wont start on carrier package unit air conditioner I have a Carrier 50ZPA042-301TP package unit


... Air Conditioners

Blower wont run motor hd46ae244


... Carrier Bryant Variable Speed Blower Motor - HD46AE244

Blower fan wont shut off


Try cycling the switch at the furnace to reset the blower board. If this doesn't work remove the green wire from the blower board(computer board) to eliminate a shorted t-stat or shorted wire between the furance and t-stat. If blower remains on, then ... Air Conditioners

Exhaust Fan (outdoor blower?) shuts off after 1 minute, and motor feels hot


Sounds like your condenser fan (the outside blower) has gone bad or the capacitor (small silver box looking thing attached to the motor). the way to test the cap. is with a digital meter that can test for micro farads. the reason it gets hot is yo ... Goodman Air Conditioners

Bryant furnace model 340mav. Furnace filter got extrey dirty due to updates in home. Started to freeze up. Caught it pretty early. Turned off unit. Thawed it out. Turned wl unit to off. Woke up in am. Furnace blower motor running. Code flashing red on furnace. Three quick red. Three longer red. Blower will not shut off unless I turn off manual switch


... Air Conditioners

Trying to determine whether I have a bad Ign/Lockout or inducer relay board on Mod 58SXA080-GG. If I shut off heat at t-stat or unplug ign mod. for 10 min. It will usually intiate a heat cycle but I only get inducer blower for 10 sec, no pilot, no spark. Then shuts down. Will not auto retry (normal?), I have to remove power. I do have 24V going to relay board when cycle starts but drops out when motor stops (I assume this is the ign module lock out). I checked the air switch by ohming out while


The inducer blower will put a vacuum on your pressure switch which in turn will tell the board to apply power to the ignitor. If you have a vent blockage, dirty air filter, plugged condensate line or any blockage of either vent or air intake, the fur ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

I found the Bryant furnace 395cav048090 calling for heat but not operational. I shut off power to the unit and switched power back on and the unit started its ignition sequence. With power on the blower starts as a result of thermostat calling for heat from the unit and after a minute goes on to second phase of ignition with exhaust blower motor initiated. During this phase gas is being brought to the burner that you can smell however burner does not ignite gas. Unit continued with this opera


If you do not see a bright light before the gas releases, your ignitor is probably out. If you disconnect, you should measure ohms from the two ignitor leads. If you do not measure any, it is open and will not work. You will usually see a mark of whi ... Bryant Air Conditioners

The outside compressor and fan will not shut off. I have turned the thermostat system to Off and even to heat, but it will not stop. I went on a trip, increased the room temp to 80 on the thermostat and left. When we returned 2 1/2 days later, the coils were frozen and no air was comiing through the vents, even with the blower motor working. So I turned the unit to furnace and melted the ice on the coils, but had to pull the fuses on the outside box to get the compressor to shut off. Is there a


Sounds like the contactor is stuck. That's why nothing will stop the fan and compressor except killing the power to it. You should be able to get one fairly cheap. ... Ruud UAKA037 Air Conditioner

Coleman 7900 gas furnace/central ac, was working fine, now blower wont come on, it tries but turns real slow then stops, i took it out and bench tested the motor andit works fine, put it back in the furnace it wont work. What do i need to replace??????


Motor run capacitor. If problem is intermittent, try wiggling wires from motor to capacitor to check for broken wires. Motor might seem to work ok with no load on bench but it has no real power. The power to really spin the motor under load comes ... Coleman Air Conditioners