Having problems with your Air Conditioners ?

Starts then stops

\015 MUH-A12YV Outdoor unit starts then stops\015

Answers :

If the fan is running ,I would say you have a freon problem.If the units starts and stops in a few seconds,then it is freon.WHICH MEANS YOU HAVE LEAK SOMEWHERE.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I HAVE A CARRIER GAS FURNACE APPROXIMATELY 10 YEARS OLD. IT WAS WORKING FINE LAST FALL. I JUST STARTED USING IT AGAIN AND NOW ITS STARTS UP AND THEN STOPS, STARTS UP AND THEN STOPS? IF I PLACE THE HEATER ON "ON" INSTEAD OF "AUTO" IT RUNS FINE. BUT WHEN I PLACE IT ON "AUTO" IT RUNS AND STOPS, RUNS AND STOPS IN 15-30 SECOND INTERVALS???? HELP!


You may need to replace the thermostat or the thermostat batteries if applicable. To replace the thermostat follow the instructions on the new thermostat. Make sure to set the thermostat to the gas setting(see instructions) this should cure your p ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

Fujitsu inverter air cond. Just stopped working properly. Model outdoor AOT30PMAL indoor unit AST30PBA-W. Code oper. Red led flashes fast continously green led (timer) repeats 13 slow flashes. After power reset it takes rem. Con. Commands however while inside it looks normal the fan in outdoor unit starts but compressor only makes attempts to start. After a number of series of 3-4 starting attempts it stops and fan stops. Three way resistance test does not indicate open or short circuit compress


It sounds like your inverter is at fault. You will need an inverter tester ( most good service techs will have one ) to prove that the output to the compressor is correct. If the inverter is okay then it will be the compressor at fault with a locatio ... Air Conditioners

Fujitsu inverter air cond. just stopped working properly. Model outdoor AOT30PMAL, indoor unit AST30PBA-W. Code oper. red led flashes fast continously, green led (timer) repeats 13 slow flashes. After power reset, it takes rem. con. commands, however, while inside it looks normal, the fan in outdoor unit starts but compressor only makes attempts to start. After a number of series of 3-4 starting attempts, it stops and fan stops. Three way resistance test does not indicate open or short circuit c


Hello, my name is Heath and it will be my pleasure to assist you. Try using a hard start capacitor on the compressor. It sounds like the compressor is having a hard time starting and overamping the circuit. If you get a hard start capacitor it may he ... Inverter Air Conditioners

Daikin fan on indoor unit start and stop continiously and after one minute or more regulate to low speed..operate only to full speed.if i set to low speed.... it start stop start stop for hour..can anyone help me?


... Cfm Daikin R410a Split System Air Conditioner

Fan starts to turn then stops , have taken sleve off. hamster wheel on rod starts to turn then stops. If i push the rod in and try to hold it, it works. but if i let go, it slowly stops.


... Fedders A3X05F2A Air Conditioner

I have a duraheat 125,000 btu auto start (salamandar) with thermostat that was used once time last spring. it won't start and my husband tossed the box and yes..insructions in the fall. starting...it hums for a few seconds and then stops. red light on thermo. goes fr solid red to flashing and humming stops while light flashes.


Here is a link to the Owners Manual for your Dura Heat Model DFA-125 forced air kerosene heater.In addition to how to properly operate it and perform routine maintenance, it has a trouble shooting guide, which should be of great assistance. ... Air Conditioners

My MSY-A17NA UNIT will start functioning normally then after about five minutes it stops blowing air and the operation led signal starts flashing. When both the operation and indicator led's are on the unit works properly. After I shut it down and start it up again the unit works fine. How can I get it to stop shutting down every 5 minutes? I'm in Hawaii and it is Hot here! Please help.


Hi,Here is a tip about Mitsubishi Air Conditioners and how to get the manuals for all of the Mitsubishi line. The manual include both troubleshooting and installation. ... Mitsubishi Air Conditioners

My air stops running inside before it get to the temp. Its set for but the outside unit keeps running and after a minute or two the air will start blowing inside again but the outside unit never turns off until it gets to the desired temp but because it stops and starts so often inside it takes a long time for it to reach the desired temp. Inside


You have a possible thermal overload problem in your furnace blower motor dirt will cause this problem when it doesnt allow air across the windings of the blower motor if not dirt the motors going bad and getting hot use a shop vac and eliminate dirt ... Goodman CKL36AR36 Air Conditioner

CONTACTOR RELAYCLOSE BUT LOOK BURNED , FAN MOTOR START , BUT COMPRESSOR MOTOR START AND STOP IMMEDIATELY. CONTACTOR STAY CLOSE BUT COMPRESSOR DON'T RUN.OR COME ON AND STOP IMMEDIATELY.


Sounds like a locked rotor, did the compressor get hot? did you check max amps on the compressor when it attempted to start?compressors have thermal protection built into their windings, a switch that will open to protect the compressor, and if the r ... Air Conditioners

3 new Coleman 47073-879 ac units don't shutoff cleanly. 2 have heat pumps and they change fan speed quickly when starting and stopping. I've never had heat pumps before but find this start and stop sequence annoying. This is a brand new coach so I expect any needed service would be covered by warranty.


... Coleman 13.5 Btu Rv Air Conditioner

Is there a way to set this A/C to power saving mode? My other A/Cs have a power save option -- for example: where when I set the AC to 75 it starts and stops trying to maintain the 75 degree temp. I don't have a manual for this Sunpentown so I'm wondering if there is a way to set it to start and stop periodically.


It is possible. But you have to refer to the user guide. Try searching in Google with model no mfr name. ... Sunpentown WA-1205E 12,000 BTU Portable Air Conditioner

I have a king of the road and the air is a duo-therm model#620015.406 as soon as the unit starts to cycle it stops running and seems to reset so after about an hour it tries to start again but does the same thing even just having the fan run it stops working. I have taken the cover off and made sure everything was clean and free of dirt and debris I have two questions for you first what could it be? is there a capacitor or something like that that would cause the problem? the next is if I decide


The compressor start up relay or capacitor is not letting it to run or compressor is low on refrigerant or overload problem or the air flow is getting obstructed.\015\012\015\012 Overload Protector:---\015\012An overload protector is a ... Air Conditioners

My ac stopped putting out cold air and I noticed the fan had stopped turningand was hot. I let it cool down and turned it back on, the fan was not turning but with a little push it started turning but very slowly, Is this the start run capacitor


It's run capacitor your unit has a dual one. One for fan and one for compressor. Make sure you get the right size when replacing it. ... Goodman CKL36AR36 Air Conditioner

I have a Nordyne Intertherm split system Model MMHA-056ABHR-01. The blower starts and stops or oscilates when trying to heat. The burner ignites fine and the fan will run fine when put on continuous. But when the thermostat is set to auto and calls for heat the blower starts then stops.


... Intertherm Air Conditioners

HI........... WHEN I START My AIR CONDITIONER TCL TAC12CS/J IT BEEPS 3 TIMES AND THEN SHOW ERROR CODE e2 BLINKING ON THE SCREEN AND THE REMOTE OF MY AIRCONDITIONER IZ NOT WORKING AND WHEN I START BY PUSHING THE START BUTTON IT START ANF AFTER 20 TO 30 MINUTES IT STOPS AND WIINGS of my air condition ARE OFF SO PLZ PLZ SOLVE MY PROBLEM PLZ


... Air Conditioners

I have a 2 year old Goodman GDS80703ANA furnace that has always had a problem starting. Sometimes it starts on the first attempt but other times it takes 2 or 3 attempts. This is what I see happening: The Induced Draft Blower starts and runs- the Igniter will glow for a few seconds and just as the igniter starts to stop glowing I hear the Gas Valve click and open but it is too late. On the next attempt or so, the Gas Valve will open sooner and burner will ignite. My question is: Is the Integrate


The board controls the timing ... Air Conditioners

The fan on outdoor unit sometimes starts normally, sometimes starts slowly and will get up to speed with a push or sometimes will not start at all. Loud hum when slow or stopped. Cools normally when it will start. Have replace capacitor. Any ideas?


SOME MODELS HAVE A TEMPERATURE DEVICE THAT CONTROLS THE FAN WHEN REAL HOT IT WILL CONTROL THE SPEED OF THE FAN WHEN COOL OUT THE FAN WILL VERY FROM FAST TO SLOW DEPANDS ON THE HEAT BEING PUT OUT BY THE OUT SIDE UNIT IF THIS PROBLEM OCCURES DURING BOT ... Air Conditioners

I have wall mount maytag a/c,M6D24E7A I been use in 8 years,but yesterday start make verry bad noise look like fan go in to broke and stop,I start back today again did start but noise is same I turn off


Mcdevito75 here, It sounds like the bearing in the fan motor is no good, Contact your local A/C shop, they come to your home and have them check it out for you. ... Maytag M6D24E7A Air Conditioner

The fan on the condensing unit isnt working it works for awhile and then shuts off,then the compressor starts to work by itself really hard and the whole condenser heats up really fast so I turn off the breaker and start it again but the fan makes and electric humm and I have to push start the blades to get it to spin and then it will work for awhile and then the fan will stop again after about an hour and then same thing happens


Does the fan turn freely or is it hard to turn by hand? If it is hard to turn the fan motor may need to be replaced. If it isn't hard to turn then check the fan capacitor. You can test it with a multimeter or take it to a heating and air supply and g ... Goodman CLT36AER36 Air Conditioner

GE Air conditioner wall unit started on 7.19.10 stopping for no reason, continued stopping on 7.20.10 like 3 times (10.40 p.m. and 2 times after that) and had to reset a/c; 7.21.10 a/c stopped at 10 p.m. - reset a/c and today, 7.22.10 NO COOL AIR at all! The fan feels cooler than the A/C. What's up with that?


... GE APN08AA Portable Air Conditioner

THE RED (OPERATION) LIGHT AND GREEN (TIMER) LIGHT ON MY FUJITSU DUCTLESS AIR CONDITIONER ARE FLASHING AND PRESSING THE START/STOP BUTTON ON THE REMOTE CONTROL DOES NOT MAKE IT WORK. BY SWITCHING THE BREAKER ON THE PANEL BOX OFF AND ON HAS SUCCEEDED TO START IT, BUT NOT ALWAYS. AFTER IT STARTS IT CAN STOP SUDDENLY, AND THE RED AND GREEN LIGHTS START FLASHING AGAIN. I HAVE HAD THIS SYSTEM FO 5 YEARS. THERE ARE 2 UNITS. THE DESCRIBED PROBLEM IS ONLY OCCURRING ON ONE UNIT. THE OTHER IS FUNCTIONI


Replace the thermistor ... Fujitsu 36CS Air Conditioner

I have a ns 2800 vented cabin heater in my hymer motorhome, it has recently failed to fire up. Following the instructions on start up, heat switch to on, power lamp lights up to activate igniter, starts to click click. After a few minutes clicking stops and it starts to blow, begins clicking again,then blow, followed by red light on flame. Closer inspection thro inspection window, shows flame not lit. Any ideas please


... Toyotomi Air Conditioners

Blower motor won't start,but spins freely when not powered.I replaceed the capacitor(2mec1).Still won't self start but if I spin it,it will start and run for 10 or 15 mins then stops and hums like it is seized.


Hi,Here is a tip about trouble shooting your air conditioner... ... Air Conditioners

My blackberry didnt get wet exactly maybe the steam got into it so i took the battery out and put the blow dryer on it, it was working okay but then it started short circeting on me, it wud stop then it would start again, my track button wont click and it's texting and calling everyone in my phonebook, i dont even have to click on anything as soon as the trackball goes over an icon it automatically clicks on the icon and starts doing its own thing, i just put it in a bag of dried rice will it fi


HI, the chances of the bag of rice doing anything is pretty slim, wht you should have done is left the battery out for a day or two to ensure the circuit board had dried out properly, then their may have been some slim chance of it working, now thats ... Air Conditioners

Fan runs but compressor won't start. Compressor tries to come on every couple of minutes, dimming lights when it does, then stops. The other unit starts and runs just fine. The problem started just lately; it has worked fine for years.


You could start by checking the capacitor. Then use an ohmmeter and check the fan windings. Hook one meter lead to com lead. Then hook the other meter lead to the run lead and then the start lead, reading the resistance each time. Then read from each ... Dometic Rooftop RV Air Conditioner