My Lennox Air conditioner only heats

\015 It's summer and my Lennox Air Conditioner is stuck in heat mode. It's model #: CHP20R-048 and it worked well last summer and heated well all through the winter. Now summer is coming and it is stuck in heat mode. For some reason it (the heat pump) will not reverse and cool. I just had the unit services about 1 month ago (just a checkup to ensure the compressor, contactors and everything else was in good working order) and it all passed with flying colors. On that day though it was cold and we didn't check the air cooling function, only the heater (which worked great). Any idea's\015

Answers :

It is possible that it's the thermostat. When you turn it into cool mode, does the unit come on at all or is it silent? If nothing is coming on, then it's likely it's the tstat. Did the tech check the refrigerant charge while he was there? He should have checked it with the auxillary heat off and the unit just in heat mode. Make sure that the condenser unit outside is coming on when you are calling for cool, If you turn it on and everything comes on, go outside and put your hand on the large copper pipe coming into the unit. In cool mode, this pipe will be cold to the touch and in heat mode, the pipe will be warm to the touch. There isn't much you can do on your own with the exception of changing the tstat. If you can answer some of the questions I have posed, I can try and give you some more answers. Just remember that a check up doesn't mean its a guarantee that something won't happen the next day, it's just that everything was in working order at the time of the checkup.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a gas furnace that was to have a 10acc air conditioner unit installed with it. Instead of the 10acc unit a 10hpr48 heat pump unit was installed, The house is 4 years old and the reversing valve has failed. The unit is not wired as a heat pump but as an ac unit with only three wires. A independent air conditioner repair company has said this installation is inproper.Is this unit installed to code and would lennox guarante a unit installed in this manner?


It should definitly be warrantied. their is nothing wrong with your set up however id have the contrator pull a new wire and go dual fuel withh outdoor sensor and get the full benifit of dual fuel. you should use the hp above 40 ... Air Conditioners

I have a Lennox CB29M Air Handler with an electric heater, which is used to heat the lower two rooms of my house. The handler unit is located in a mud room right behind the back patio. I'd like to get an air conditioner unit that can mount on the patio that can be hooked up to this air handler, so I can have air and heat in these two rooms. Are there units that are available that can work with this air handler? How hard is the install, and can you recommend anyone in the 19030 area that I can tr


Any of these Lennox dealers can help you choose a compatible HS29 or HP 29 condenser and evaporator coil to match your system.http://www.lennox.com/locate/default.asp ... Air Conditioners

My Lennox Air conditioner only heats


It is possible that it's the thermostat. When you turn it into cool mode, does the unit come on at all or is it silent? If nothing is coming on, then it's likely it's the tstat. Did the tech check the refrigerant charge while he was there? He sho ... Air Conditioners

Hi I have a Lennox heat and air conditioner roof top on my unit. What's happening is,the heat turns on for a about 10 minutes then shuts off, the only way to turn it back on is to turn off the thermostat, then turn it back on, but will keep doing the same. Oh and one other thing, the filter warning is showing on the thermostat, could it be as simple as changing the filters? Any suggestions anyone?


You are right, you must change the filters, since it isno longer working normally. May this help you. ... Air Conditioners

Air conditioner Model MSH-RV18 when using the remote to switch on and select heat the air conditioner expels cool air not hot air. But when I select the emergency heat button, the air conditioner expels hot air Many Thanks Julie


Hello,Please, change the battery of the remote, if the problem continue, there is a reset button on your remote, reset the remote.If the problem continues, then, your remote sensor receiver on the ac unit is bad, you \015\012 ... Mitsubishi Air Conditioners

Heating problem hello! My air conditioner stopped to heat. (there is a around 8 degrees C, outside and 16 degrees inside). It worked just fine, and now, when I switched to heating mode, there was nothing. the defrost LED ond the inside unit is switched on, but air is not comming from the unit. Cooling mode works fine. If you could please help me finding the solution for my problem. Thanks in advance. RAdan GE AIR CONDITIONER SPLIT SYSTEM WON'T WORK ON HEAT CYCLE Seems to work ok doing eve


Hi Radan, Did you get this problem solved? We have an Electrolux Kelvinator Split System and ours is doing exactly the same thing. I am struggling to find a solulution. Would be great if you can offer any advice.\015\012\015\012Thanks Nic ... Air Conditioners

Inducer blower motor will not start, no heat - Lennox Air Conditioners


... Lennox Air Conditioners

Lennox CB29M-31-1P heat is intermitant - Air Conditioners


... Air Conditioners

Need a wiring diagram for 1988 lennox heat and air conditioner. model # chp15-411-3p


Are you sure the modle # is good?Cant find any thing? ... Air Conditioners

Have an amana central air duelfuel heat system.when aux heat[gas] heats the house and shuts off the fans still blow for 3 to 5 minutes with the last couple of minutes being cold air which cools the air it just heated. also heatpump will start heating when it comes on then after 3 or 4 minutes it starts blowing cold air like when the air conditioner is running.i have had problems from day of install 4 mounths ago with problems that keep coming up. please i need help fast i do not think comp


Change your heating delay to shut off sooner, you can find this in the installation manual. Also the Thermostat may have delay after heat as well. It is true there could be many variables, but it also sounds like the Heatpump is not charged properl ... Amana Air Conditioners

Dear FixYa Experts, I am a new home owner. I have a Kenmore Air Conditioner (heat pump?, see more details below) with Lincoln Gas Furnace. According to the former owner, the heating system will start heat pump first when the temperature is above -15C and then turn on the gas furnace when the temperature drops below -15C. Recently, when I turn on the heating system, only the gas furnace was always running but not the Kenmore air conditioner. And our average temperature was always above +5C for


... Kenmore Air Conditioners

My son has a Goodman Manufacturer Corp Heat Pump/air conditioner. Forced air I believe. The air conditioner quit. A repairman indicated that in order to replace the air conditioner the furnace will have to be replaced also. The air conditioner unit outside is Model No. CPE30-1-AB. Any thoughts?


I don't see any reason to change the furnace unless it's an air handler and not a furnace with a coil on top or bottom. And then, the only reason to change the inside unit when you change the outside unit is because it's a R-22 system and your going ... Goodman CKL30AR30 Air Conditioner

Bryant air conditioner - outside unit will not run - before it quit running, air temperature in house rose from 65 degrees to 75 degrees. Inside fan continued to blow - air smelled like a car air conditioner that ran out of Freon. Bought Freon - need to know where to add it. The heat pump model # BF-163S bi directional but also coming from unit is another line that runs same direction with same type of valves. Air conditioner model # 697CN030 - B


... Air Conditioners

I own a non programmable digital thermostast RTH3100C THAT WAS INSTALLED AND KEPT MY AIR CONDITIONER COOLING WELL. HOWEVER, WHEN I TURN TO HEAT IT WOULD NOT HEAT THE PLACE. I JUST GOT COOL AIR. I WAS INFORMED BY YOUR CO. THAT THIS THERMOSTAT IS NOT FOR HEATING. I HAVE AN A/C WITH A PACKAGE OUTSIDE AND AN INSIDE AIR HANDLER WITH A HEAT ELEMENT. COULD IT BE LHAT IT WAS NOT PROPERLY WIRE. I ONLY HAVE THREE WIRES FROM THE OLD THERMOSTAT


Are there any wires on the e or aux terminals. those are the terminals for heat ... Air Conditioners

I buy air conditioner mark haier after 3 years the compressore its failer, when replace the compressore and compleate the air conditioner i hear high sound in the outer unit such us the flowing of flow (type of air conditioner split type 2ton cooling and heating reversing valve) thank you wit best regard


If unit was not evacuated after compressor change out it is possible to have are in system. Gas needs to be reclaimed, and evacuated with vacuum pump ,and recharged. Rus ... Air Conditioners

I have two Amcor AmcorAire UCHW-H09AF2 Split System Air Conditioner units -- 2 years old. One works fine, but the other does not blow heated air (Heat Mode). It is cold outside, but the good unit is blowing heated air at the same time the bad one does not. All other settings are the same. All suggested service numbers, as well as the company number in user guide are disconnected. Thanks


... Amcor Aire UCHW-H09AF2 Split System Air Conditioner

MSZ-A24NA Split System Air Conditioner: it stopped heating, air comes out but no heat, brr...


Is it defrosting??? Your problem is quite brief and that is the only advice that I can offer based on your question.\012\012\012Hope this helps\012I take the time to answer your question so please rate me ... Mitsubishi MSZ-A24NA Split System Air Conditioner

Air-conditioner our air conditioner feels like its blowing heat but its on air


My aircondition in my house evrytime we turn on its covering eyes and has not blowing a heater can you give me the answer please. ... Intertherm P3RA-048K Air Conditioner

I HAVE AN AMERICAN STANDARD HEAT PUMP/AIR CONDITIONER UNIT OUTSIDE MY MOBILE HOME A FEW DAYS AGO A UNKNOWN SMELL COMES THRU ALL VENTS IN AIR CONDITIONER MODE ONLY. WHEN HEAT IS ON THERE IS NO SMELL UNTIL IT GOES IN DEFROST MODE AND THEN IT SMELLS ONLY A FEW SECONDS , WHEN HEAT COMES THRU IT STOPS. I NEVER HEARD OF THIS. THANK YOU


This is a condition called Dirty Socks Syndrome air cleaners and dehumidify usually fix the problem also adding a uv light to the duct can remedy the problem the light is probally the cheapest solution ... LG LS-K1830CL Cool Mini Split Air Conditioner

I have an air conditioner Appliance AAC 1100 A-PTC that wos working for two days and now its not cooling or heating:-( Both outer and inner parts of the machine seems to be running but it wont heat or cool the room. When i try to turn it on there is a red symbol that lights up on the display (defrosting) this light goes off every 5 minutes or so,then the machine starts to blow air (not heated or cooled) for aprox 20 seconds then the red light comes on again and this procedure starts over again.


... Air Conditioners

My Fujitsu Converter Air conditioner is not working... The Green light is flashing 13 times - the red light flashes continuously very quickly. The fan does not commence at all and therefore no heat or cool air comes from the conditioner at present. Also, once I press the start button on the remote control unit and the light being to flash, I am then unable to stop the unit - even after pushing the start/stop button - the lights continue to flash. Is there something I can do to make the air c


... Fujitsu Air Conditioners

Heating problem hello! My air conditioner stopped to heat. (there is a around 8 degrees C, outside and 16 degrees inside). It worked just fine, and now, when I switched to heating mode, there was nothing. the defrost LED ond the inside unit is switched on, but air is not comming from the unit. Cooling mode works fine. If you could please help me finding the solution for my problem. Thanks in advance. RAdan


The LG>LW5200ER AC is not listed as a heat providing unit. Click on link and this will give you the spec's\015\012\015\012 \015\012\015\012 ... LG LW5200ER Air Conditioner

Rheem air conditioner blowing air no heat - Air Conditioners


Bad Defrost board ... Air Conditioners

I have a honeywell pro 2000 programmable thermostat which controls an enerzone ahc 31-18 series water source air handler with heating and cooling coils built in. This therostat and heater worked fine all winter. Last week i had a air conditioner stalled and connected to the air handler and the AC worked for one day. When i tried to turn on the AC yesterday, the fan would not come on for either AC or heat. any troubleshooting suggestions? thanks ... Donald


... Air Conditioners

I have pane air handler, split sistem. When it runs air conditioner it also runs emergency heat at same time. If I tern the sistem off the emergency heat is still on. It blow worm air. How can I solve this problem? I changed kontrol board for new one, but it did not help. help me please...


You have a stuck relay.\015\012Locate the relay that powers up the heat strips and verify that it is closed when power is disconected.\015\012\015\012If it is, replace the relay.\015\012 ... Air Conditioners