Having problems with your Air Conditioners ?

I have a bard heat pump central air in my house

\015 I replaced afew worn parts in the unit and I must have wired them wrong and the wire diagram is worn off the unit now my blower wont shut off without cutting the power\015

Answers :

Http://www.bardhvac.com/digcat/S3364_TechDoc_CD/QH60/QH60.pdf
\015\012
\015\012I hope this is the correct wiring diagram for you. Good luck with it!

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a bard heat pump central air in my house


Http://www.bardhvac.com/digcat/S3364_TechDoc_CD/QH60/QH60.pdf\015\012\015\012I hope this is the correct wiring diagram for you. G ... Air Conditioners

I have a Rheem CLassic 10 Seer Heat Pump Model Number is RPKA-035JAZ I'm not familiar with certain terminology, but basically, it seems as though the unit is not cooling down the house anymore. It is just blowing air. The thermostat is not on "Fan", it is on "Cool". The central air system is not on "Auto" but "On" for continuous cooling. The temperature is on 65 degrees but not change has been made. It's not hot in the house but it certainly isn't cool and it feels as the there is less air p


Hello my name is Heath it will be my pleasure to assist you. The auto or on switch is the fan switch put this on auto. Then on the thermostat set it to cool and turn the thermostat down and the outside unit should come on and the house should cool d ... Air Conditioners

My house in Florida was built in the fifties and I think that when the central air unit with pump and gas heating was installed the installer may have used the existing chimney-probably for an earlier oil furnace. The exhaust tube goes from the unit horizontally to meet the chimney in the attic and then vertically to the top of the roof..In the attic the enclosure-as well as above the top of the roof for three feet is made up of concrete blocks..We have had a very cold month here in Central Flo


Hi,\015\012To do that you need what is called "B-vent". It is a double wall pipe that will work as long as you maintain 1" to any combustible materials. This pipe will also keep the exhaust hot enough to prevent condensation.\015\012Most ... Air Conditioners

Installed a grant combi vortex 26e in January. Went back today to drain down and replace some radiator valves with leaking glands etc. When I filled and vented system, hot water fine, pump runs etc. Central heating will not fire although pump running. Pipework around boiler and by-pass very hot. No overheat. pump is free of air and spinning. I think in total I managed to get the burner to fire for on minute on central heating today. Confused. Could the by-pass be stealing all the heat? Could it


... Air Conditioners

Have an amana central air duelfuel heat system.when aux heat[gas] heats the house and shuts off the fans still blow for 3 to 5 minutes with the last couple of minutes being cold air which cools the air it just heated. also heatpump will start heating when it comes on then after 3 or 4 minutes it starts blowing cold air like when the air conditioner is running.i have had problems from day of install 4 mounths ago with problems that keep coming up. please i need help fast i do not think comp


Change your heating delay to shut off sooner, you can find this in the installation manual. Also the Thermostat may have delay after heat as well. It is true there could be many variables, but it also sounds like the Heatpump is not charged properl ... Amana Air Conditioners

I have a goodman gsh130361 3 ton heat & air. It was installed 05/05/2008. all seemed well until cold weather, in 2009. The fan turns on and start blowing before the heat box is even warm. The heat set on 70----- when it gets 68 or 69 {in the house} the out side pump kicks in, 10 to 20 seconds later the fan turns on and blows freezing air into the house. the temperture will drop dramatically for the next 1 & 1/2 minute. The box will heat up and then all is well untill the next cycle.


The PCB unit that controls the thermostat and Coolant is malfunctioning... check that particular unit...that would help.... ... Goodman Air Conditioners

Have a Grand Aire Central Air and Heating unit a/heat pump...has been working fine. Switched it over to heat and nothing came on. Switched it back over to air, which was working and still nothing came on. Switched fan from ''auto'' to ''on'' and the fan will not come on. Used a screwdriver to push the contact in and everything runs (air and heat) as long as I am holding the contact in. Changed the t-stat, still the same problem. I really don't have the finances to call a pro in, any advice will


The fuse may be in line (red ) wire check control voltage if not present transformer (or fuse) needs replaced \015\012 the problem probably was caused by white wire (heat control voltage) has been wired to common not heat control ... Air Conditioners

I have a gas furnace that was to have a 10acc air conditioner unit installed with it. Instead of the 10acc unit a 10hpr48 heat pump unit was installed, The house is 4 years old and the reversing valve has failed. The unit is not wired as a heat pump but as an ac unit with only three wires. A independent air conditioner repair company has said this installation is inproper.Is this unit installed to code and would lennox guarante a unit installed in this manner?


It should definitly be warrantied. their is nothing wrong with your set up however id have the contrator pull a new wire and go dual fuel withh outdoor sensor and get the full benifit of dual fuel. you should use the hp above 40 ... Air Conditioners

Every time my heat pump turns on, the blue auxilliary light comes on, and it only blows icy air. I do not want to use that much power, so I turn it back down a few degrees. Now, it is 50 degrees in the house. Tonight it will be around 16 degrees outside. How can I get my heat pump to produce warm air?


A heat pump starts losing efficiency below 30F or so. The aux. heat helps the heat pump keep up with heat demand. The Aux heat can be electric heat strips or another type of heat. Check to make sure you have power to whatever type of aux heat you hav ... Amana PTH123B25AJ Heat Pump Air Conditioner

Thermostat setting I just bought a new house and I have a heat pump-we live in North Carolina. The name on the thermostat is Braeburn and it is a multi-stage 2 heat/ l cool digital thermostat. We have it set at 68 and when the blower first comes on it blows warm air-however then it switches to cool air. And sometimes cool air comes out first. We have set both stages to 68 and it is in the heat mode. Should the 1st and 2nd setting be different?


What i would do is see if the outside unit is working at all. when you first turn it on the air was warm due to the fact that the temperature inside was cooler than the set point. when it get within 2 degrees ... Weather King 12AJA6001AH Air Conditioner

I have an NewAir 12000H Portable Air conditioner with a heat pump. The problem is that the heat pump no longer seams to be working. The desired temperature is 79 degrees. the unit never gets above 75 degree. when it actually gets that high it because my heat from the house has turned on. once the heat goes off then the unit goes down to 72 degrees and stays there until my heat comes back on. whats wrong with the unit? is there anything that i can do?


It sounds like the actual control module, the "brain", of this heater / air conditioner has failed and can't sense when to kick on the heat any longer. Have you tried just unplugging the unit for a good 5 minutes minimum and seeing if it will help " ... NewAir Air Conditioners

I have a heat pump system with gas as auxillary heat. What outside temperature should I switch my thermostat to "Emerg Heat" to run only gas? I also have a dial that appears to be some sort of temperature control on the lines that run outside the house to the compressor unit (currently set at approx 32). Is this for defrost control or does it tell the heat pump to shut down when the outside air gets below where this dial is set and then use only gas heat?


The dial thing you are talking about is a low ambient control that will not let the heat pump run below the set temperature should be set between 32 and 40 degrees farenheit. The heat pump is not effiecent below 32 degrees as I would reccomend only r ... Air Conditioners

Hi: Last week, a contractor installed the above-mentioned new 16 seer heat pump, an air handler and a heat kit. Our house has 3 levels, each about 800 square fit. Initially the house would not heat above 56 degrees. Therefore the contractor drained 2 oz of Puron gas from the line, then decided to put 0.5 oz of Puron gas back in. The temperature is now rising to the desired temperature. However, it seems to be rising rather slowly, i.e. 1 degree per hour while utilizing the auxiliary heat (w


That is worrysome about putting refrigerant in hap hazzardly... There is a math style process involving pressures and temperatures in two locations that dictate how much ref. goes in. Anything else shows clueless installer. Too much or too little ref ... Air Conditioners

I have two heatpumps up and downstairs and two furnaces (piigy back). At times my pump outside freezes up and cold air blows in the house. I was told that I needed a kit to tell my furnace to turn on when it gets to cold for the heat pump. It will cost 400. This is the third time they came out. 1-nothing wrong. 2-New thermostat 3-Need kit. Is this something I can do? Amana Heat Pump RHA36B2A


Hi,\015\012A couple of things... First your furnace should be 2nd stage on a 2 stage thermostat and if the heat pump don't keep up your furnace should be coming on anyway...If you get a Honeywell Vision Pro 8000 series thermostat for 2 stage he ... Air Conditioners

We have central heat an air , the heat is up in the attic and the air is outside, our problem is that the air is blowing in the house but th unit outside doesn't come on , what could be the problem. Thanks


Check your breaker or fuses. for the outside unit. It may be getting the "Signal" to come on but there is no power. Start there and let me know. ... Air Conditioners

Thermostats i replace my thermostat that runs my heat pump, boiler, and central air. The heat pump should not run until it is below 40 but it is running along with the boiler


Check wiring ... Air Conditioners

My thermostat inside my house will not shut off, runs constantly now, on both a/c and heat cycles. Does the thermostat need to be replaced?I have central air and heat. Recently tried to shut off the heater one morning , had warmed up outside and was too warm in house. I could not get the heater to shut off even manually. finally tried turning on the a/c, it came on but it would not shut off later when it reached temperature set even when I manually tried to shut it off. My outside unit (a/c) is


Hello\015\012IF this is a programable stat.Take the batteries out and replace them.\015\012Then reprogram the stat.\015\012\015\012IF this is not programable have the wiring checked at the unit and the stat.May need to replac ... Air Conditioners

I just had a new compressor installed in my heat pump. My heat pump compressor turns off (I can hear it) in air conditioner mode when the outside temperature is greater than 95F. The temperature inside the house rises quickly in the afternoons during these conditions. It works great when outside temperature is < than 95F. Is there a problem?


It sounds as if it is tripping on high pressure. This can be directly related to outdoor temp. Most residential a/c units will run a maximum capacity over 95 degrees. The compressor should not be shutting down though.The best thing you ca ... Air Conditioners

Bryant air conditioner - outside unit will not run - before it quit running, air temperature in house rose from 65 degrees to 75 degrees. Inside fan continued to blow - air smelled like a car air conditioner that ran out of Freon. Bought Freon - need to know where to add it. The heat pump model # BF-163S bi directional but also coming from unit is another line that runs same direction with same type of valves. Air conditioner model # 697CN030 - B


... Air Conditioners

Why would my heat pump central air blow cold then warm


... Air Conditioners

Hi! I have a problem with an oil heating system! When I turn it on, it heat for 5 mins then stops. I have changed out the circulation pump as I thought that this was the problem. The pipes in the boiler are warm. The heat doesn't go to the radiators around the house. I Found that only 1 radiator heats upstairs. There is water in the radiators and none are air locked as i have tried them all.


You may have many probs... 1 a poir boiler combustion. (not boiling the water) or just warming it up so it's not hot...that would mean your temperature sensor is broken or you have probs with the actual combustion process.. This could be an unsafe s ... Air Conditioners

Details I have a problem with a Goodman Model GSH130601AA, ( 5 Ton, 13 Seer heat pump) central air unit, installed 06/15/2006. (I know, I saw online reviews but unit was put in before I saw negative e


The fan motor is bad and needs replaced. Depending on how mechanically inclined you are, you can replace it yourself fairly easy, the hardest part being the fan blade without a hub puller. Just take your old one in with you to a local A/C supply stor ... Air Conditioners

New Ruud 16 seer central air and heat pump - very noisy


A few things to check\015\0121) Is the unit mounted on metal brackets attatched to\015\012the house, is so I would probably put rubber pads\015\012between the unit and the brackets to absorb the\015\012vibration.\015\012 ... Ruud Matching Split Air Conditioner

My central heater is not blowing hot air, I am having to turn the thermostat on and off. I have the thermostat to 70, and the heater will blow hot air and then it will just circulate the air in the house, therefore bringing the temperature down. I looked at the unit and noticed that when the thermocople (heating element) goes red, the gas valve makes clicking and the flames come and then go out very fast. I noticed lots of clicking in coming from the gas valve. help please


Hi!!! relax your flame sensor is bad change and you will be fine..If it turns off and on change your flame sensor ... Air Conditioners

The air condition heat pump will not keep the house cool we have it set at 73 degrees and it is 83 degrees in the house The unit is about 4 years old and i haven't had this problems before , the technicion says he can't find anything wrong with it.Ihave a 1400 squire feet house and a 3 ton unit


Hi,Here is a tip about trouble shooting your air conditioner... ... Weather King Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1663 seconds