Indoor unit freezing up

\015 5 ton ac on old oil furnace belt driven unit freezing up sometimes not all the time 6" pulley on motor 8"on blower can i change pulleys to get more air flow has 3/4 hp motor\015

Answers :

The coil probably needs to be pulled and cleaned with a power washer. Usually what happens is the coil becomes dirty over time and when the filter starts to get dirty as well, it will cause the unit to free up. Also it could also be a little low on refrigerant and when the temps change, it can cause the coil to freeze up. But I bet it is in need of a good tune up and coil cleaning.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Indoor unit freezes up, turn the mode button to the fan only to thaw out the indoor unit but the outdoor unit runs, What should I look for?


If the outdoor unit is not shutting off, your indoor coil will freeze up when the thermostat "satisfies" and shuts off the blower. The most common cause of a non-stop outdoor unit is the contactor. This part is usually black or brown in color. The li ... Air Conditioners

Hi, there is a Ductless LG Model # LA180CP that has freez up problem. Sometimes it freez up after 3 days working and some times after couple of hours working. Freez up start from indoor unit. Average of super heat is 10, but it is changing all time between 6-15. suction line Temp 45F, Discharge 53F, On Gage 35F, Supply Air Temp 8.2C and Return Air Temp is 22C. What do you think about this issue? THanks


What refig and where are the pressures. freeze up is always low charge or lack of air flow and always occurs at the evap. Once it starts and you loose surface area you have to defrost manually ... Air Conditioners

I have been working on a Goodman Heat pump. The indoor coil keeps freezing. Outdoor temp is 70F and indoor is 78F. It has a brand new air filter. My superheat is 2F and subcooling is 10F. I have replaced the blower motor. This is a 2.5 unit, my return duct is 12x14, there is a return grill at the return side of the furnace 8x8. It has been working fine for the last couple of years. If I take freon out my superheat become -2. I think I got an airflow issue, and that's why I replaced the blower m


HelloIs there a high speed setting for the blower motor.Check the specs on the rpm requierd for the unit. ... Air Conditioners

Indoor unit freezing up


The coil probably needs to be pulled and cleaned with a power washer. Usually what happens is the coil becomes dirty over time and when the filter starts to get dirty as well, it will cause the unit to free up. Also it could also be a little low on ... Goodman CLQ36AR49 Air Conditioner

Air conditioner I have a panasonic air conditioner split system about 10 years old. It has stopped working yesterday.  The fan is not moving.  It seems to be smoking freeze air from the indoor unit.   No cold air coming out.   What should I do.  What can I do.


Faulty main control board or wiring loop may be a problem? ... Air Conditioners

Brand new LG mini split,24,000 BTU. One indoor unit is freezing on first start up but not the other.


Hi,\012That is a typical indication of a low charge of freon....\012Check the charge and also for a leak in the system...\012Here is a tip about trouble shooting your ... GE Quiet-Aire Ductless Split System Air Conditioner AS1CD12AA0/AS0CD12AA0

A/C Unit SAMSUNG -Outdoor unit model= MH080FXCA 4A was connected to 3 indoor units: · B location – indoor unit model MH035FNCA · C location – indoor unit model MH035FNCA · D location – indoor unit model AQV18JA (This unit has no rotary switch SW02, so I don’t know how to set it for communication with the outdoor unit) I set the outdoor SW01 to 3, because 3 units are connected of possible 4. I moved the dip switch of the outdoor unit to “off” position. I set the indoo


... Samsung Air Conditioners

I have a Mitsubishi split system with 2 indoor units (MS09TW) and one outdorr (MU09TW). The evaporator coil on one of the indoor units has been diagnosed by a A/C repair company as having a pinhole leak. I would rather repair the entire indoor unit but I can't find an avaialable replacement unit. Is there a model that will directly replace my existing unit. The evaporator coil PN is E02 462 620


The following link includes service manuals for your air conditioning system: http://usa.mylinkdrive.com/uploads/documents/2388/document/MS-09~17TW,TN__MU-09~17TW,TN_Service_Manual.pdfI'm sure you find the solution inside the manual. ... Mitsubishi MS09TW Air Conditioner

The control for the compressor is not turning on when the remote is set on cool, but the indoor fans turn on. This is a C4822N outside unit and a RS 2422A twin indoor unit. there is 220 volt being sent down on black and white to the indoor unit but nothing comes back to the outside unit on red


... Sanyo Split System Air Conditioner

I purchased an Amcoraire split system unit for my 2 story garage. Licensced electrician did the wiring and licensed HVAC co. installed the 2 indoor units and outside unit. Outdoor unit is Model # AOM 243 HX 24000 BTU Indoor units are both Model #AWM123 HX, 12000 BTU each When I turn the unit on, it runs for about 60 seconds and then I get an error code on the inside wall unit that says P7. My manual says this has something to do with voltage. I had the power company come out and they show the


Since the manual says the error code has something to do with voltage it means the voltage is either too high or too low. And as the electric company says the voltage is within limits the the error is as a result of the voltage fluctuating. All you h ... Amcor Air Conditioners

Hi there, I have two Fujitsu DC Inverter split units to heat my flat (england). The temperatures have dropped significantly -2 and below. This causes the outlet pipes to freeze up and when the units are on defrost the excess water gushes out of all other joints in the units. This causes two problems - the units are wall mounted one on top of the other, so the top unit freezes the bottom unit. The second problem is the bottom unit 'dumps' in on the floor of the area which when defrosted s


Normal cool temp 23 to 25 and heat mode 29 to 31. And regrading defrosting your pipelines no need any tray. You can insulate with Armaflex tube which is mostly used for best insulation. Hope there won't be further water leak. ... Air Conditioners

Several years ago I purchased 2 Split-Type Room Air Conditioners--Models RSW-17 (Indoor Unit)/ROW-17 (Outdoor Unit) and RSW-12S (Indoor Unit)/ROW-12S (Outdoor Unit). The airconditioners themselves are fine, however,the Remote Controls for both these units, Model AR-DJ15, have gone bad and may not be repairable. How/where can I purchase replacement remote units? Alternatively, where/how can I send my remote units for repair? Chester D. Copemann [email protected] or [email protected]


Type in the mfg. name in the search bar and see if you can find resources. ... Air Conditioners

Have a Multi Split Indoor unit ASU9RD - 2 units and Outdoor unit AOU18RD. Operation blinking GREEN; Timer blinking RED. Remotes not responding, Turn off units at circuit breaker, units still blinking the same. Both indoor units went down at same time. Had unit serviced in June 2010. What are the blinking lights telling us (Code)?


Hi.Here error codes:ERROR CONTENTS ... Fujitsu 12C1 Air Conditioner

I have a sanyo split air conditioner unit. The indoor unit is a rs2422b and the outdoor unit is a c4822. The #26 led is flashing which indicates a communication error between indoor's main and sub unit. I checked and cleaned all the connections. The unit worked for a couple days, but now I am getting the same error code. Is there a problem with the board in the unit.


... Sanyo Air Conditioners

Hi the outdoor unit turns on ( fan runs) the indoor unit does open, no heat or cold air blowing. In just fan mode the unit works fine etc speed setting ok. Its a sharp split type air model # ae-a244j outdoor,ay-a244j indoor unit what would be the problem, theres only two parts in the outside unit behind the side plate where the wires info is,small black box three wires and a round unit with wires. I hope this is help full cheers andrew


My gut says that this is evidence of a bad control board(circuit board). As usual, double check that your batteries are good in the thermostat. I have seen some weird things happen when the batteries are low. This one may be a job for your local con ... Sharp Air Conditioners

Indoor unit temperature between 60F & 70F after R22 charge..


If anything, it appears undercharged. Purging is not recommended. @90 degrees the high side corresponding pressure is 168.4 and Low side coresponding numbers re70psi/68degrees. With all due respect to the tech I think . If your room temp is 80, th ... Sanyo Split System Air Conditioner

I have noticed my heat pump is freezing up on the outside unit, we have had freezing rain and snow the last 2 days but I have never noticed ice accumulation on the outside of the unit, it also seems like it is not heating as quickly as it once did. How can I defrost the unit in freezing weather?


In freezing weather the heat pump efficiency drops. The freezing is normal. The equipment has a board and sensor to defrost your heat pump. Now this system can fail but freezing rain and snow get pulled into the unit get pulled into the unit coil and ... Goodman Air Conditioners

If indoor units power supply sopposed to be 220 and the output power supply going to the indoor units is 214, can the indoor unit work


Yes manufactures figure power to the unit can fluctuate 5% plus or minus. You are within 3% of stated voltage any higher may be a problem. ... Air Conditioners

I have carrier split unit the problem is the when switch it on indoor unit runs but when outdoor unit runs it make cool just for 5 mins and all unit indoor and outdoor go shutdown and green light start blinking and after 5 mins unit starts again after 5 mins again shutdown . any sugges please.


... Carrier 38CKC036 Air Conditioner

Indoor unit coil air temperature 60F - 70F after R22 charge..


With ambient air temperature@ 65 with R12 Pressure should be 63.8 psi\015\012Discharge air should be approximately 10 to 20 dgrees cooler than ambient. @ 70 degrees ambient the pressure70.2 -R-12. It is unlawful to discharge freon into the a ... Sanyo Split System Air Conditioner

Unit freezing, pumping down, not cooling.


Your expansion valve (LEV) is restricted, replace it. ... Air Conditioners

Hi. I recently installed 1.5 T, 3 * Split AC, LG. Whole day the AC works fine and no problem in cooling too. But once in 2 day outdoor unit start making thudding noise continously and does not stop for 4 to 5 second and after that indoor unit stops cooling and just fan runs. No cooling is done after that and room temperature keep increasing. The green LED of compressor in indoor unit is ON, compressor does not work. To achieve cooling again I have to switch off whole unit for like half an hour a


HelloSounds like the compressor is shuting down on high heat.There could be a couple reasons for this.1 Check that proper voltage is being supplied to compressor.2 Freon level may be low.This would be a service call.3 Ba ... LG Air Conditioners

I have a Daikin 2 x Daikin outdoor unit RZP125DV1 and 2 X Daikin indoor unit FHYCP125DVE - 1 for upstairs 1 for downstairs. On the upstairs remote controller i have got display "U4" (believe this means indoor unit not talkiing to outdoor unit) It works ok when Op Mode icon is on "fan".When I press "test" button code "5JC" displays. What does this mean ?


... Cfm Daikin R410a Split System Air Conditioner

Recently installed indoor unit and outdoor unit. Outdoor unit has not been wired yet. Installer said I could use indoor unit on em heat until it gets wired. Installed one week ago, now does not work. HELP!!!


Hi, wow I can't believe they left you with E-Heat only, running the blower with the heat strips on!! Like it says, for an emergency in the event you loose you're compressor. You say that know you have nothing.I would have to be on site to wire the co ... Honeywell ER150B Air Conditioner

Hi ...we have a split fujitsu air con for just over 5 years. The compressor in the outdoor unit is not starting up and the indoor unit blows ambient air. The operation light is lit and the timer light is continuously flashing when in use. Have reset the breaker and the units and also the remote to no avail. Can't find any info on the net or in the manual. Any tech help most appreciated. (Also doesn't seem to be a auto/manual reset buttn as such in the indoor unit)


There is a relay that the thermostat pulls in, in the unit outside. When this happens, the compressor pulls in and the unit outside will run. The compressor has to run before the unit will cool. ... Fujitsu 24C1 Air Conditioner