Having problems with your Air Conditioners ?

Dometic duo-therm I have a motorhome with 2 a/c and the ccc. One is working well but does not keep temp. To operate you have to manually turn off and on. The rear unit the fan comes on but the compressor doesn't. I pulled the cover but I don't know how to check the capacitors or other various items.


Answers :

The first unit sounds like the indoor and outdoor coils need a good cleaning especially if its an older unit. The second unit sounds like the compressor is bad. Can you do an ohms test on each of the leads to the compressor to see if it is bad? If you can then you will know. Otherwise, I would recommend having it serviced by a professional.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Dometic duo-therm I have a motorhome with 2 a/c and the ccc. One is working well but does not keep temp. To operate you have to manually turn off and on. The rear unit the fan comes on but the compressor doesn't. I pulled the cover but I don't know how to check the capacitors or other various items.


The first unit sounds like the indoor and outdoor coils need a good cleaning especially if its an older unit. The second unit sounds like the compressor is bad. Can you do an ohms test on each of the leads to the compressor to see if it is bad? If ... Dometic Rooftop RV Air Conditioner

We live in southwest Florida. Our HVAC system consists of a air conditioning system with heating coils when it is cool. Yesterday morning we tried the heat nothing come on. Later in the day I tried the air nothing. I tried turning in just the fan nothing. I just checked the breaker I have power where the wires are connected. I went out to the outside unit and pulled the cover. Pushed in a spring loaded plastic switch the fan on outside unit works and shut off when I released the switch. But noth


Hello. Sounds like you do have power. That spring loaded plastic switch is a 24v contactor. It pulls in when energized. If you push it in manually everything shoud run normal. Ck your 24v transformer. On one side (feed) you should have 115v or 220v ... Air Conditioners

Air conditioner comes on fan only. the compressor doesnt seem to be coming on. the is no cool air blowing. the unit is brand new and was jusy installed.


There will be option in remote to on the fan and compressor separately may be you would not have on-ed the compressor through remote or else there would have been any loose connection in the wire which connects the compressor ... Friedrich Air Conditioners

I have the MR36TQY3f outdoor unit with 2 MW09Y3FM units and 1 MW12Y3FM indoor units! The MW12.. works great and one of the MW9... works great! When I run the 2nd MW9 only (other MW9 & MW12 off)..... the outdoor unit compressor or fan does not come on! If I run all units then ... compressor kicks on runs great, fan runs... lines get cold on the 2 good units ... nothing on 3rd unit... then I turn 2 good units off....and it sounds like the compressor kicks off and the fan will continue to run reall


After looking at the manual for the units, I believe that the system is having trouble with the number of units that you have linked. Here is a portion of the manual about multi system operation>Also link to manual:http://www.fri ... Friedrich MR36TQY3F Split System Air Conditioner

Compressor problem? My outdoor unit comes on with the fan blowing just fine. Then I hear a buzzing sound for about 2-3 seconds which I believe is the compressor trying to come on. (Incidentally, a couple of lights inside the house seem to dim at the same time that the buzzing sound occurs.) The buzzing sound reoccurs every couple minutes while the outdoor unit fan and the indoor blower both continue to run. I have shut down both the outdoor and indoor units for a couple hours and tried restarti


The buzzing is your compressor trying to start. It is going off on internal overload caused by heating up of the motor windings.If you have an amp meter you could check the amp draw of the comp against the locked rotor amps listed on the tag You cou ... Ruud UBHC Air Conditioner

We installed a Honeywell RTH230B thermostat on a Trane XE60 Air Handeler this winter. When we put the system on heat it works fine. However, when we put the system on auto for cool the compressor fan comes on but not the air handeler fan. On the air handeler the terminal strip from left to right is R W Y G B/C. The red wire on the R terminal comes from the contactor on the compressor unit. The other wire from the compressor unit is connected to a gray wire that goes to the thermostat. The W


I ran into this before and had to call Honeywell for help in the wiring...it seems the wiring was not done to standard, and they were able to help me get it straight in about 10 minutes and at no charge. ... Air Conditioners

Gsc13 outside unit fan and compressor will not come on. swapprd contactor and capacitor and still will not run. have 24v at contactor and coil pulling in. all 3 legs on capacitor only have 120 volt


... Goodman Air Conditioners

I recently had a new outdoor unit installed on my central heat and air conditioning sytem. I have had the installer out 3 times and the system still does not operate correctly. Sometimes when it cycles (every other time or every third time) the unit does not blow cold air. Sometimes the unit comes on not blowing cold air and the compressor fan is running but not the compressor. Sometimes after 15 minutes of this the compressor will come on. What is the problem.


It sounds like the compressor needs starting components installed on it. All a/c units have a run capacitor for the compressor and another one for the condenser fan motor. These motors use these capacitors all the time when the motor is running. H ... Air Conditioners

I have a whirlpool model ACM102xLO that seems to be dying. I cleaned the coils, and the unit seems to operate normally for a few minutes. Fan motor works, compressor motor seems to work. When I checked the amp pull on the fan motor, it falls in the normal range of 1.2A. When the compressor kicks on, the amp pull jumps to around 10 and climbs to a high of 15 or so, then the compressor shuts off and the amps jump to about 25 or 26, before cutting off completely. The amps then drop to the fan motor


... Whirlpool Air Conditioners

The interior unit comes on normally, but the exterior unit - compressor starts - fan does not. Fuses check OK - compressor stops in short time. Fan never starts, just a hum, and hot to touch. Could the fan be the problem, or starter relay??? Help please.


Make sure the fan turns freely. No obstructions or bad bearing. And check the capacitor ... Frigidaire Air Conditioners

Goodman a/c j41 fan not running, turned off and on at fuse box, took a look at the box next to a/c unit and opened the box on the wall and pulled the plug and pulled the plastic panel off, there is no fuses. So i put back together and turned the a/c unit on, now at thermostat the snowflake is no longer flashing, some cold air coming out of vents, but outside a/c unit fan still does not run.


First you need to disconnect all power. Try spinning the fan blade, if it spins freely, then try moving the shaft from side to side to see if there's any side play. If not then the bearings are OK. If there seems to be some drag when your spinning th ... Goodman CKL42AR42 Air Conditioner

I have a Jantrol heat pump & A/C. It is approximately 10 years old. For the last 3 summers the compressor unit will freeze when the air handler fans fails to come on. It worked fine for 2 weeks this year before it happened. I've be able to thaw it out and restart the unit and it works from days to weeks before this occurs again. The last time it happen, I had a problem getting the air handler fan to come back on, but it did eventually. I've been thinking it may be the sequencer, but now I'm wond


Hi,\015\012\015\012If you can safely check the supply to the motor when it should be on, then this is the best method to check it.\015\012\015\012Check the fan turns very freely - oil the bearings if it doesn't.\015\012 ... Goodman Air Conditioners

I have a Carrier 38CKC036 Air Conditioner Unit. When I turn the thermostat on cool the compressor comes on but the fan on th unit clicks like it wants to come on but it dont. Could the fan be bad? What do you think the problem is?


Hello, this is one of 2 items...the motor itself, or the start capacitor. The capacitor is responsible for boosting the motor to get it started. Follow the wires from the motor and they will lead to an oval or round cylinder. Check the cylinder f ... Carrier 38CKC036 Air Conditioner

Neither A/C compressor or fan coming on in ouside unit.


The bulge is a telltale sign of a defective capacitor along with the tripped breaker. Replace it and cross your fingers. ... Carrier 38CKC036 Air Conditioner

EMERSON FAN MOTOR WHICH HAS A BLK WIRE PURPLE WIRE AND A BROWN WIRE WENT DEAD. SO I BOUGHT A NEW FAN EMERSON CAME WITH 4 WIRES BLK ,WHITH, BR AND BRW AND BRW WITH WHITE STRIPE. I WIRED IT BLK TO THE CONTACTOR WHITE TO THE COMM THE YELLOW FROM COMPRESSOR TO THE HERM BRW TO THE FAN BRW WITH WHITE STRIPE TO THE COMM THERE IS A RED WIRE GOING FROM THE COM TO THE CONTACTOR WHEN I TURN THE AC UNIT THE COMPRESSOR COMES ON PUT FAN DOES NOT ?????


The two brown wires go to the fans capacitor. The capacitor should always be changed with the fan motor.\015\012\015\012It sounds like your unit has a dual capacitor. One side for the fan and the other for the compressor. All you will be ... Dometic Rooftop RV Air Conditioner

I have a comfortmaker unit with heat strips. The blower fan comes in and blows cool air. I have checked voltage at the transformer, and it is producing 24 vac. The contactor for the fan and condenser never pull in so I replaced the defrost control circuit board. Still only blows cool air and the defrost cycle never comes on. I jump 24vac to the coil on contactor and the defrost fan came on and the condenser came on so the fan motor and start/run capacitor are good. Any suggestions.


... Air Conditioners

Compressor does not run. On turning the AC on, the compressor does not run. The blower fan does though. Checking the relay panel, the relay for the compressor does not engerize. a temporary solution is to put a switch across the contacts the compressor on and then the thermostate is set so that the AC should work, the fan comes on and the unit works as usual. The only exception is that the temperature must be controlled manually.


Hi, if you are energizing the contacts on the contactor, and the compressor runs, the thermostat is faulty. This is what energizes the contactor coil that you have. You need to check to see if you have voltage to the coil on the contactor. You need t ... Coleman Mach 15 Air Conditioner

AC Out. Two year old house. Goodman A/C, two units one for upstairs. Cleaned coils of both outside unit, replaced filters, re-set breakers. Upstairs is cooling. Downstairs unit is running outside, not circulating air inside (inside temp 87). Vents inside are cool to touch, no air. Outside unit fan is pulling, but air exhaust is cool. Compressor ? Should air be circulating even if compressor not functioning. Is there anything in attic exchange that would affect downstairs circulation. Thanks.


Assuming that the 2 systems are isolated, that there isn't any cross over between the systems...It is normal for an air conditioner system, from window unit to central, to be able to circulate the air, even if not cooling. This is known ... Air Conditioners

Have a duratherm ac unit in travel trailer compressor comes on and fan just hums, fan will run if turned by hand continues to heat up as it runs


... Air Conditioners

My air conditional unit outside ,fans turns on but the unit compressor wont turn on,just stopped working this morning.i turned the thermostat to 72 but only the fan on the outside unit comes on and it is hot inside the house..


Somethings aperson cant fix without a service tech. First it could be wire burnt of capacitor going to compressor. Second it could be bad capacitor. There is a dual capacitor on the ouside unit one side says herm that runs the compressor. Turn pow ... Emerson Quiet Kool 12HT13 Air Conditioner

I noticed some straining noise coming from my a/c unit today. The fan on top of the condenser runs fine but as soon as the compressor tries to kick on the fan stops for a split second and you get a kind of surging noise from the condenser unit. Then the fans kicks back on, the the process repeats itself every couple of minutes. Meanwhile no cold air is being produced inside the house. Any ideas?


You amy ahave a bvad capacitor on the outside unit. It starts the fan and the compressor. You can change this yourself. Open the outside panel and you will see a silver canister with terminals out the top. Replace this and I think your problem will g ... Goodman CKL24AR24 Air Conditioner

A/C worked fine last year. Turned it on for the first time this year and the outside unit does not come on. The inside unit fan works just fine. I checked the circut breaker and turned on and off. No change. I revoved the cover and do not see any burnt wires or any problem. Not sure what to do next. I have a meter... what should the voltage be where the power comes into the unit at L1 ect. please help... thx


Check and see if you have 24volts at the contactor outside.if you do you have a bad contactor. if you don't take the tstat off the wall and take a jumper wire and jump out R to Y on the t-stat if i ... Air Conditioners

The outside unit keeps tripping the breaker. It will run for a few seconds, loud rumble, then stops, and does this for about five minutes before tripping the breaker. I just bought the house. The unit is about 8 yrs old. I pulled off the cover and the inside near the compressor is full of dirt. We had a bad storm with lighting the night the unit started acting up. Should I replace the capacitor or is my compressor bad?


There is a process to go thru for checking the unit to see which part is causing the problem. first thing, listen to the compressor when it first tries to start. if the compressor does nothing and the breaker trips then you will have to check the com ... Ruud UBHC Air Conditioner

My AC My Compressor keeps kicking off. I turn the unit on, the fan works. The Heat works but the compressor turns in about 60 sec. If I unplug the unit and turn it back on, it comes on but the compressor shuts off again after 60 sec. Can this be from dirt in the coils? They have some build up. Any other causes?


One might think so, YES the compressor is running till it gets hot and tripps on hi-temperature, and after it cools down awhile, the switch willcautomatically reset itself and back- & forth......Thank-you-very much! ... GE Zoneline AZ38H12DAD Split System Air Conditioner

1996 Coleman Model 7333C8876. Have 2 units on our Motor Home one day it was hot so I had both units running controlled by a Electronic Climate Control system. It got cool in the evening so I turned them off. The next day when i fired them both up on high the rear was fine. But the front will only cool on Low. The fan will not run on high and you can hear a slight noise coming from the unit. But the fan will not run on high.


Check to make sure the drain tube is clear. It sounds like the blower fan is dragging in water buil-up. ... Air Conditioners