Ihave a l.g. lsu242he unit that is not working. The diagnostic light is fluttering and not giveing any code. Board has been replaced to no avail. Replaced board on inside unit. no change. condensor fan runs evan if inside unit is turned off. This unit ran perfect for aboutone month


Answers :

Sounds like some of the low voltage wiring has shorted out. This will make the light flutter like that and will make the condenser fan motor run as well. If you replaced the boards and are getting the same issue, then the only thing is can be is a low voltage short.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Ihave a l.g. lsu242he unit that is not working. The diagnostic light is fluttering and not giveing any code. Board has been replaced to no avail. Replaced board on inside unit. no change. condensor fan runs evan if inside unit is turned off. This unit ran perfect for aboutone month


Sounds like some of the low voltage wiring has shorted out. This will make the light flutter like that and will make the condenser fan motor run as well. If you replaced the boards and are getting the same issue, then the only thing is can be is a ... LG Air Conditioners

Hi, I have a samsung aqv18ja series split type air conditioner (cooling and heating) wall unit. the unit was install in 02/12/2009. By "one hour heating and air conditioning". In this short time service the outside compressor has been replace, the system has check and recheck,for cooling leak. the inside unit fan motor has been change. but the problem still exists. The inside unit fan continues to run when the unit is "off" and with the remote off.


Simple, check in your remote. There is an option button "Blow". Just press it. Your unit gets completely off. Please write back if helpful? ... Samsung Air Conditioners

The fan blows but condensor not ruuning. service people have changed cappasitor,circut board,replaced evapor coil(leak),pressures just fine. the unit will work poperly for about an hour then only fan


Could be the run cap for the condensor is bad. If you got a multimeter you can test it. ... Air Conditioners

Air conditioning unit not running but fan keeps running even though thermostat is turned to off, auto, and temp set to highest position 90degrees. 3 amp fuse keeps blowing on the circuit board in the blower compartment. I replaced it 3 times then installed a new thermostat. no change. I can usually figure it out if I got a little input or direction. Any help would be deeply appreciated. I would much rather have a trained expert easily repair my hvac unit but I can only call the professionals in


If the fuse is blowing then this is generally indicative of a short in the low voltage wiring, isolate the wires on the thermostat and the unit ends, use an ohmmeter to verify that there is no path for continuity with no wires touching, if there is t ... Air Conditioners

Blower fan stays running. Fan relay attached to small circuit board (coil tabs [timer?]). Capacitor on small circuit board had ''fallen out'' of ic board. Tried to get replacement board, and was sold just a standard relay - told that relay alone replaced the previous relay -and- circuit board configuration (?). Problem still exists (no change). Also changed thermostat just to eliminate as a possible cause, but seems like problem must be in the fan relay area. Question about the wires attache


... Carrier Air Conditioners

I have an XB10 Trane AC unit that was installed when my house was built in 2003. After running it for a while, the compressor either seems to shut down and I notice no cold air as though its just the fan. Sometimes when I start it back up my thermostat says ''wait''. Or it just blows the fan, even though its set for cold. I've had the capacitor replaced, a start up capacitor bridged to it. I've changed the filter and had the coils cleaned with a brush and garden house from the inside. I'v


... Air Conditioners

A mate has a fujitsu ast24rba-w, the outdoor unit runs but the indoor fan won't go. Found indoor board buggered so I replaced it, fan still no go. Got hold of a fan that I know works and still won't run!! Checked the start capacitor and that meters ok. It won't even run on fan only. From what I can see the fan should run, there is nothing left to replace. Any advice would be greatly appreciated!!!


... Fujitsu 24C1 Air Conditioner

Borg warner Is the old round York Borg/Warner thermostat incompatable with a Honeywell? I just replaced my old round mercy switch thermostat with a Honeywell RTHL111 thermostat. The air conditioner service man says it is hooked up right, but the fan on the unit will not run on auto (it must be in the on position on the thermostat [thus the fan runs all the time]). He also replaced a relay switch inside the unit. We are using air conditioning only on this unit. Red to R (strapped to Rc), gree


... Air Conditioners

AC Out. Two year old house. Goodman A/C, two units one for upstairs. Cleaned coils of both outside unit, replaced filters, re-set breakers. Upstairs is cooling. Downstairs unit is running outside, not circulating air inside (inside temp 87). Vents inside are cool to touch, no air. Outside unit fan is pulling, but air exhaust is cool. Compressor ? Should air be circulating even if compressor not functioning. Is there anything in attic exchange that would affect downstairs circulation. Thanks.


Assuming that the 2 systems are isolated, that there isn't any cross over between the systems...It is normal for an air conditioner system, from window unit to central, to be able to circulate the air, even if not cooling. This is known ... Air Conditioners

Outside fan not running, inside unit running fine. Compressor was running this morning, but no longer. Replaced fan motor, turned power back on, now fan or compressor not running. What else can be checked?


Hi,\012There may be a manual reset high limit... look for a red button on a round part hooked to the small copper line and push it in hard...\012Also the compressor may have kicked the overload and needs a few hours to cool and it reset, ... Goodman Air Conditioners

When the unit is in heat mode is the fan on the outside supose to run? Capacitor on outside and inside have been replace fan was running when capacitor was first replaced.


Hi, and the outdoor condenser fan should not be on at all in the heat mode unless this is a heat-pump!! So, I can see that this is a 3-ton Carrier split system and I haven't pulled up any information on it, only if I need to. But if the indoor unit r ... Carrier 38CKC036 Air Conditioner

I have a dometic heat pump a/c basement park model unit. The fan is not working. The compressor runs, but no air inside or out. I have power into the run cap. but not on the brown wire to the fan from the run cap. I also have no power to the fan high or low off of the relay board. Where do I go next to isolate?


... Dometic Air Conditioners

Carrier 38 leo 30320 ac unit....when the compressor shuts off the fan keeps running. a rap on the control panel shuts it off. I when changed the contactor the inside unit stopped working so I put the


Hello, if the indoor blower runs nonstop a relay in the intergrated control board faulty and the whole board must be replaced, you can get tap the board to stop the blower but eventually the board will need to be replaced. If the contactor is clicki ... Carrier Air Conditioners

Hello , this is Bobby and I have a Coleman Mach rooftop air conditioning unit Model # 8335B8964 when I turn on the unit ,it throws the circuit breaker . I have replaced the starting capacitor and the running capacitor for the compressor, the fan runs ok.Is there a circuit board for this particular unit?


Here's a link to a service manual, with step by step tests to determine whats wrong. I'm thinking compressor shot, but this should confirm, and or help you determine for yourself. Be careful with those capacitors eh !! Read warning in service manual. ... Coleman Mach 15 Air Conditioner

This is a Fujitsu floor mounted aircon unit. In either heating or cooling modes the 20amp circuit drops out almost immediately after the soft start switch activates. The on board 5 amp fuse is not blown. The fan inside this unit runs very briefly before the breaker lets go. The wall unit fan is unaffected if used by itself.


Hi,\015\012You did not list a model number...so I am just speculating a bit here...\015\012It would seem as though the compressor is either locked rotor or the compressor motor is shorted...\015\012When the power goes to the compres ... Air Conditioners

Just cut on 8 year old Goodman CPLE24-1 AC for the summer. Ran 8 hours fine, Next morning noticed outside unit running, very little cool air blowing out of inside floor vents (like the blower fan was broken). Outside unit frozen. Capicitor replaced last July. (2) separate filters inside house returns clean. Whatz the problem? Help? Advice? Gotta fix it fast! By myself hopefully. Thanks!!!!


Due to the many different questions I see about Air Conditioning, I am including this overview to help us better understand each other for trouble shooting. A basic air conditioning system has a Thermostat, Air Handler or Furnace Fan and a Condensin ... Goodman CPLE24-1 Air Conditioner

I have a rheem 030jaz (heat pump) that has been affect by lighting that hit the house. I have change the transformer, zone board, and what I thought was a bad fan. What happens now is where it gets crazy. The unit will run for about 30 minutes then the cold side of the compress will begin to freeze. When this happens the fan will turn off and the compressor still runs. The evaporator is clean enough to eat off of. Pressure readings for freon stay consistent through out the freezing stage. This t


Hello Sounds like the reversing valve is not changing over during the defrost cycle.The R/Valve selonid coil could be damaged. ... Air Conditioners

Hitachi model: ras-3.5ages unit trips on 02 fault pressures are ok. unit runs ok for approx 2 hours pressures still ok then trips on 02 fault. system can not be reset after fault occurs.pc boards run through test ok. condensor fan also ok. could the problem be faulty high pressure sensor or faulty thermister.


... Hitachi Air Conditioners

I have a Goodman Package unit Model # PGJ 03075-1. The blower motor only rocks back and forth while the compressor and fan run and begin to form frost on the pipes. I replaced the large capacitor, main control board, fan control board, thermostat, and removed the control module off the back of the ECM motor to look for burned areas. There are no visible burned areas. Any ideas on what to check next? Rick


The blower motor only rocks back and forth ? That means it is getting power. Most of these have their own smaller capacitor did you check it?\015\012Any sloppy vertical movement means the motor bearings are shot, the motor is what we ca ... Goodman CPLE24-1 Air Conditioner

I have an 8 year old 2 1/2 ton carrier compressor unit. I have already replaced the running coil and contactor. I now want to clean the coils and fan blades on the motor. I have never had reason to remove the top grill. I looks as though the fan motor is attached, and I don?t want to do anything stupid ?if I can help it? or damage or disconnect any of the wires. what is the proper way for me to access the inside of the unit so as to be able to spray off any debris that may be on the coils. So fa


Hey Bernie, it is possible to remove the 4 screws on the grill that the motor is mounted to (not the bolts holding the motor to the grill)and pull up and twist so its upside down and have someone else hold it as to not put to much stress on the wires ... Carrier 38CKC042 Air Conditioner

Trane xe 1000 - 1/4 fan motor went bad - I replaced it with a used 1/3 from another trane unit - it had same wiring harness etc everything starts, runs, cools -cold air - but only for about 5 minutes...then condensing unit shuts off - inside blower keeps running though... I'm thinkin thermostat....you?


Did the 2 fans have the same rpm. If there is not enough airflow through the outside unit the compressor will shutdown on high discharge pressure. Also make sure the fan blades are positioned right if there is a shroud for them. Did the other motor h ... Air Conditioners

My heat pump will not come on in HEAT or A/C. I thought I might have a simple defrost control board problem, but still no go after replacing the board and the defrost relay. I checked the pressure switch and it is not tripped. I've checked all the circuit breakers and they, too, are all set. I've checked the outside unit using the "test" switch inside on the start relay and the unit will come on, but won't stay running on it's own. When I select HEAT, I wait the necessary five minutes for the un


Hi; Need more info. How old is the equipment,look on the outside unit data plate it will give the built date usually in the top right corner. Also heat pumps can run with a faulty defrost board. I would check for control voltage at the secondary side ... Ruud UBHC Air Conditioner

Carrier 58RAV095-16 will process thru the test sequence properly: inducer fan, ignitor, blower high, blower low, all ok. fuse checked good on controller board. when commanded to supply heat by the thermostat controller in the living space the unit runs with fan only, no gas, no ignition. changed thermostat controller, no joy. Comments: Jan 31, 2010 - thermocouple/ignitor is ok and positioned well. It tests ok too. I changed it last year. I am not getting gas flow so I suspect gas control va


Go to the furnace and turn off the power take the door off you must have a multimeter inhand with the cover off the furnace and access to the gas valve put yor meter leads on the wires going to the gas valve turn the power on and after the ignitor gl ... Air Conditioners

KELVINATOR KSR20C Our split systeme air con does not heat or cool the outside fan run when on but the inside fan doesnt run the little led on the circuit board on the outside unit is blinking on for 3 sec ond off for 3 sec do these air cons have a fault codes ??


One might think so, YES! look on one of the door panels that you can remove! Thank-you-very-much! ... GE Zoneline AZ38H12DAD Split System Air Conditioner

I have a suburban lp furnace and duotherm air/heat pump roof unit. duothern thermostat. 20 amp breaker kicked ( reset breaker) & furnace quit. NOW furnace fan comes on but does not light, and the front AC will not work either, when in the COOL position on STAT the unit blows warm air instead of cold. I replaced the Thermostat and a Tech guy checked the board in the furnace and it was OK. He also switched the board from the rear air with the front and nothing changed. Rear air and heat pump works


I'm not sure what the problem may be but you could try calling All\015\012Seasons RV Appliance Parts & Service. There number is\015\0121-800-344-0673 they have helped me in the past. That and there tech\015\012calls are free so it wouldn't hurt ... Dometic Rooftop RV Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1394 seconds