Having problems with your Air Conditioners ?

No heat My 7500 zoneline will not provide heat consistantly. I can unpplug the main power source to the control boards and plug it back in, ,and I will then get heat. If I turn down the thermostat (80 to 70), then turn it back up, I do not get heat again, only cool blower air. Is one of my control boards bad? Thanks.


Answers :

It sounds like it could be the tstat itself. Unless you use a voltage meter to take some readings it's hard to determine if it is a board. The best thing for you to do is remove the tstat from the system and manually operate it with a jumper wire to try and recreate the problem. If you can't recreate it, by manually turning on the unit, then it's the t-stat and if you can then it is the board. This happens with t-stats occasionally. Good luck and I hope this helps!

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

No heat My 7500 zoneline will not provide heat consistantly. I can unpplug the main power source to the control boards and plug it back in, ,and I will then get heat. If I turn down the thermostat (80 to 70), then turn it back up, I do not get heat again, only cool blower air. Is one of my control boards bad? Thanks.


It sounds like it could be the tstat itself. Unless you use a voltage meter to take some readings it's hard to determine if it is a board. The best thing for you to do is remove the tstat from the system and manually operate it with a jumper wire t ... GE Air Conditioners

We have model # 58SXA080-JG Gas Furnace-the fan is not turning on-heat is not coming thru the vents. We had the control unit/circuit board replaced yesterday. The fan, pilot light and heat came thru the vents for a few minutes-then stopped. Can't get it to come back on..Trying to find what else it could be


Blower Control Circuit Board (Carrier, Payne, Bryant) is the faulty partInput Control Voltage: 18-30 VAC.\015\012Frequency: 50/60 Hz.\015\012Power Consumption: 5 watts max.\015\012Output Ratings:-on high contact: 20 amps resistive @ ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

I have a Heat Controller EKTH15-150J PTAC. Of lat,e toward the end of winter here in southern Missour,i the unit while in heat mode has been randomly blowing cold air. Often you can shut off the unit and let it sit for awhile and when you turn it back on it will come up heating again. A couple of years ago I replaced the control board that had been killed by a lightning induced power surge with a RSKP006 control board kit. It has run fine since, until the last few months. Sometimes I can pu


Your problem sounds more like a reversing valve issue.The reversing valve will tend to stick and not close completely causing cool air instead of warm.Check the low voltage wires to the control board(usually orange) and the 24 volt signal ... Comfort-Aire EKTH15-150J Air Conditioner

Fan will not turn on. heat coils heat up but blower will not spin. i installed a new blower motor and a new control board but still getting same results


When you changed the motor, did you change the capacitor? If the motor hums, but doesn't run, the capacitor may be the problem. Also, about a week or so ago, I changed a furnace blower and capacitor only to have it shut down again after 2 days. I ... Amana Air Conditioners

I have a honeywell PA404A pressure control switch on my home gas steam heating system. I'm having a problem with the switch turning off the system. It will only come back on if I turn the top screw all the way out, then back down to approx 5psi. At this point the heat will turn on but when the thermostat shuts down the system it will not turn back on when calling for heat unless I adjust the screw again. Also, the switch will only turn on the system when set at 5 on the dial on the inside. Any i


This may be caused by accumulation of sludge in the steam trap (the looped tube that connects the pressuretrol unit to the boiler). the sludge restricts the pressure from reaching the diaphragm in the pressuretrol unit. So it gets a false reading. ... Air Conditioners

Goodman Gas Pack Unit. Model PGB048125 Control Board 1068-400 Installed 1993. ** No Heat. ** Checked breaker at box. ** Have changed thermostat, no change. ** control board LED light shows: Red: System turned off at thermostat Red: A/C turned on. Flashing Red: Heat turned on at thermostat.


Count the number of flashes and consult your manual as to what the flashes mean. The blower access door may show the faults codes. What you probably have is a contaminated flame sensor or maybe a rollout switch tripped due to rusty burners or air res ... Air Conditioners

I have a remote comfort control with 3308448.004 relay board. Press Heat button to turn unit on and it does NOT turn on. Have 115VAC to the relay board and have 12VDC to remote control reciever. Sounds like the remote control reciever is bad?? Can I switch my system to the "wired" control system without changing the relay board? I assume it is possible that the relay board is also bad. Is this a common fault with these units?


... Dometic Rooftop RV Air Conditioner

When call for heat on model # WGPH-10eamer serial number DF5D302f419801914 the furance goes throught the cycles, the burner comes on and cuts off after 8 seconds. The flame censor was changed and the power was shut down for 30 minutes. It was then turned back on and the furance worked for a while and then repeated the problem. On the control board-there are 3 lights. 2 greens and sometimes the yellow one. Thats when the yellow is working right. The yellow one does not come on that much.


It could be the control board, But before I would replace the board I would check to see if the flame sensor is not touching the burner and shorting it out. Also check the flue make sure it is open. This has a combustion blower on it and a proving pr ... Weather King Air Conditioners

I have a multifuel stove which runs my central heating system from its back boiler. When it gets really hot there is a loud clicking and knocking sound from the rear of the stove where the thermostatic control is. The noise stops when I turn the electric pump off. How do I fix this please?


That clicking and knocking noise you hear is called cavitation. It's when the bubbles of steam are cooled down rapidly and implode upon themselves. Cavitation is not a good thing to have in a boiler as it can cause dramas. This cavitation is more ... Air Conditioners

I turn the thermostat down at night. When I get up in the morning I turn it back up. The heat kicks on for a minute or two then the unit starts blowing colder air. If I turn the thermostat to the OFF position, wait until I hear all blowers stop, then turn it back to the ON position, it will start blowing HOT air again. Some times I have to perform this cycle 3 times to get it to keep blowing hot air. Any ideas as to what is shutting the furnace off? Thanks, Wayne


Theremostat switch problem. Replace it. ... Air Conditioners

I have a ruud pvp50-1 gas hot water heater, the water gets cold. I can turn it off and reset it and turn it back on, it heats up normally but then the water gets cold again. To heat the water again


... Air Conditioners

No heat My air conditioner on my unit went out via power surge back in the summer. A/C man came out and rewired the circuit board so we could have A/C but the heat would not work. He had to order in a new pc board. Since all of that happened, A/C man has gone out of business. Now no one wants to come out and fix what he messed up without charging the **** out of me. I already paid once and don't want to pay again, at least not yet. Can some one tell me how to rewire that pc board to get heat, ot


THERMOSTAT ... Intertherm P3RA-048K Air Conditioner

I have an NewAir 12000H Portable Air conditioner with a heat pump. The problem is that the heat pump no longer seams to be working. The desired temperature is 79 degrees. the unit never gets above 75 degree. when it actually gets that high it because my heat from the house has turned on. once the heat goes off then the unit goes down to 72 degrees and stays there until my heat comes back on. whats wrong with the unit? is there anything that i can do?


It sounds like the actual control module, the "brain", of this heater / air conditioner has failed and can't sense when to kick on the heat any longer. Have you tried just unplugging the unit for a good 5 minutes minimum and seeing if it will help " ... NewAir Air Conditioners

With unit set to air conditioning, the controller board will not turn on the blower motor and the cooling coil freezes up. McNutt tells me the controller board is kaput and they want $550 for it. In the meantime they have jumpered over the controller so the blower runs constantly. Was hoping someone might be able to tell me where to get it for less. It is HSCI Furnace Controller For Use With All Gasses 1012-940, model HK42FZ011


? need more info like make model and serial numbers ... Air Conditioners

Brivis Ducted Heating system. No display on Programmable controller inside hoiuse. Electronic Control (Model 14100) located on Heater (outside house)displays "Searching". Have turned off power and left for 1 hr then turned back on - no change. Tried resetting through buttons but no change. Have assumed Electronic controller has died - but can't find troubleshooting guide to prove. Don't want to waste $$$ if can be avoided.


Hi,I have an identical issue with my Brivis.Did you get a solution?Mine can be running, then goes blank and says searching. it will eventually come back.Just wondering if you had to replace the 14100?CheersJ ... Air Conditioners

I have a 1f89-211 model thermostat. it's stuck on heat it won't turn to cool or even off. i have to turn the heat off from the breaker box. i only use the about five or six times a year. i live in florida and use the a/c amost year round and i can get it to come on. i've taken the cover off and there is one slid bottom that i have moved back and fourth. still nothing but heat comes out. please help and thanks for reading


I will try to help you based on the limited information in front of me. \015\012The first thing I want you to do, is try to reset the thermostat. Take the face off of the thermostat. The reset button is located just below the Fan button. Here i ... Air Conditioners

My central heating unit in house will not turn off. Thermostat sends signal when temp is reached but heat and fan keep running, I changed fan relay but no change, have to turn off breaker to get if to go off, when breaker is turned back on it is off as long as thermostat is at temp


Definately a relay - but i suspect inside the controller itself.Replace the thermostat(controller) unit.Thanks for using FixYA!! ... Air Conditioners

The circulating pump for the central heating from my stanley brandon is not working there is no power to it from the electronic control board I have changed the electronic control board and there is still no power (the boiler starts and runs but stops when the temperature gets too high due to no water circulation


Hi,i think the problem is possibly from the thermal fuse or the electrical motor of your device,i think you should run a troubleshoot on these parts and change the part that is affected to restore your unit back in a perfect working condition.\015\0 ... Air Conditioners

I can't get my heat or ac to work in my motor home the comfort control will turn on but I can't get the heater or ac to turn on..


Check thermostat to see if that is not cuasing your issue. A bad thermo stat will cause the unit not to turn on. Check the thermostat but it to 70 degrees then go to the ac. heater unit and check and see if the temp is @ 70 to begin with if its not c ... Air Conditioners

Hi. I have a LG heat pump/air conditioner. A split system with 2 indoor units. Model LMN095HV and LMN125HV. After a power failure by our local power company, I am getting a CH 05 error code. I have turned off th power to the units and waited several minutes and turned it back on with no luck. I know the code means poor or no communication with the outside unite. And I am getting the same code on both inside units. an you help? Thanks, Peter C [email protected]


Hi, this error is a communication error between your indoor and outdoor unit, check all wiring and connections - ch 5 is a communication error between the indoor unit and the outdoor unit.\015\012You can try turning the breaker off ... LG LSC183VMA Split System Air Conditioner

We have recently bought a house with Vulcan ducted gas heating (no pilot light). When the system comes on it produces plenty of heat so I don't think there is anything wrong with the unit itself. Frequently, however, it reaches the set temperature, turns off, and then will not come back on even if we press the on/off button. The only way we can get it back on is to cut power to the house and then press the on button. That would suggest that there may be some kind of program set, but since


By the things you said here it seams that is nothing wrong with the device itself but it has something to do with the thermostat ...The thermostat is the part that it supposed to shut it down when the temperature gets to the set value....and also it ... Air Conditioners

Hi, I have Worcester Sentinel x100 boiler and the other night someof the pipes in the house burst and the water pressure dropped in the boiler. I got the pipes fixed but now I can;t get the boiler back on. It won't start back up despite refilling the heating sytem. I am pressing the start/on/off button on teh top of the control panel and have set the seperate control panel to come as manual however there is no blue light showing on the blue start button as normally does when the boile


... Air Conditioners

My central heating system comprises a worcester bosch system boiler and honeywell smartfit controls. The problem I am having is that the central heating doesn't seem to knock off at the preset temperature I have to go to the room unit and reduce the temperature by 2/3 degrees and then turn it back up; is the fault in the room unit or a sticking relay in the control unit? regards terry


You could possibly have an ignition problem. The controller will go into a lock-out condition if flame is not established. Turning the temperature control down and then back up may be serving to reset the control system so it tries again. ... Honeywell Air Conditioners

Every time my heat pump turns on, the blue auxilliary light comes on, and it only blows icy air. I do not want to use that much power, so I turn it back down a few degrees. Now, it is 50 degrees in the house. Tonight it will be around 16 degrees outside. How can I get my heat pump to produce warm air?


A heat pump starts losing efficiency below 30F or so. The aux. heat helps the heat pump keep up with heat demand. The Aux heat can be electric heat strips or another type of heat. Check to make sure you have power to whatever type of aux heat you hav ... Amana PTH123B25AJ Heat Pump Air Conditioner

I have a fujitsu twin head air con that is at least 10 years old the external compressor is not turning on but it does work my fridge mech was not sure of problem but thought it was the control board not sure of the model but it had a aot 19 rm !!!and finished with 2 can i get a new control board from some where or am generic replacement part


The outdoor PCB has a series of led's on it which indicate the status of what is operating. If the lights are on and nothings working then you will need a new outdoor pcb which is only availible from fujitsu. ... Fujitsu 18C1 Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific