Having problems with your Air Conditioners ?

The fan hums wont turn goodman air conditioning

\015 Hums fan wont turn,wont do any thing but hum\015

Answers :

If you are talking about the fan on the outdoor unit, let's try some things.
\015\012Kill power to the outdoor unit. Use breaker or disconnect. Now see if the fan will spin with no power going to the unit. If not, bad bearings. Fan D.O.A. If it does spin, good.
\015\012Now restore power and turn unit on. If fan runs now, it has a defective or damaged winding. Needs replacing. If it does not start running, most likely the capacitor is D.O.A. or the fan is "Electrically" locked up. Again, fan D.O.A.
\015\012If you do replace the fan motor, be sure to always replace the capacitor. It's usually only a few buck more.
\015\012Also, be extremely careful when trying to spin that fan. It may take off and take a finger with it. NEVER try to spin the fan with power going to it.
\015\012This is no joke, it's dangerous if you don't know what your doing.
\015\012It may well be worth having a tech check things out for you.
\015\012In any case, good luck and again, be extra careful. Never do this type of work alone, in case something happens unexpectedly.
\015\012And as a side note, you may find it next to impossible to find anyone to sell you the motor. Most all HVAC parts houses are wholesale only and will not sell to the general public just to HVAC companys. That's because they are trained to do this stuff with out injury.
\015\012Think it over and good luck.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

The fan hums wont turn goodman air conditioning


If you are talking about the fan on the outdoor unit, let's try some things.\015\012Kill power to the outdoor unit. Use breaker or disconnect. Now see if the fan will spin with no power going to the unit. If not, bad bearings. Fan D.O.A. If ... Goodman CLJ30AR32 Air Conditioner

Goodman air fan hums wont turn - Goodman CLQ36AR49 Air Conditioner


Either has a bad start capacitor or bearings have gone dry, and shaft is stuck. Motor would probably have to replaced. ... Goodman CLQ36AR49 Air Conditioner

Furnace is a York Model#p4ugd12n09001a probably installed around 1991. The air condition was working fine. couple of days ago nothing was working. Blower wont tun on, air conditioning unit wont turn on. I did have the fan on the on position on the thermostat so it was always on until it stopped.


Probably a bad low voltage transformer. ... Air Conditioners

I have a goodman Air conditioning unit CKL49-1. The fan motor connects to the top lid. Recently the metal cracked and broke and the fan fell down inside. I purchassed a new lid mounted the fan back on to the lid. It doesnt seem that any major damage was caused. I put everything back together the way it was. When I turn it on it will only go on for a sec then a switch inside turns it off. When i looked at the electrical on the ac i noticed when i turn it on a little spark on a switch and the swit


Sounds like it is overloading and tripping the circuit breaker (that thing that pops up). More than likely when the fan fell down it stopped the blade from turning which caused the motor to overheat, melting the windings insulation which caused them ... Goodman CKL49AR49 Air Conditioner

MY AIR CONDITION ONLY PUT OUT WARM AIR EVERYTHING SEEMS TO BE OK FILTER TURNS ON OK BUT THE OUTSIDE UNIT HUMS BUT DOES NOT FAN


Sounds like you have a bad t-stat see what kind of system you are running ie. heat pump staight air gas then get that kind of t-stat. turn off power to units and replace make a note of what wires go where. ... Goodman Air Conditioners

My air conditional unit outside ,fans turns on but the unit compressor wont turn on,just stopped working this morning.i turned the thermostat to 72 but only the fan on the outside unit comes on and it is hot inside the house..


Somethings aperson cant fix without a service tech. First it could be wire burnt of capacitor going to compressor. Second it could be bad capacitor. There is a dual capacitor on the ouside unit one side says herm that runs the compressor. Turn pow ... Emerson Quiet Kool 12HT13 Air Conditioner

Goodman outdoor AC/Heating unit, model #: GPG10420901A will not turn on heat. If I place the fan mode to "ON" it will blow the cold air, and the Air Conditioning works fine. When placed on "Auto" the blowe will not turn on and no heat is produced.


... Air Conditioners

The air conditioning wont turn on. The fan turns on but when it tries to cool it just goes back to the fan.


\015\012Compressor won’t Start\015\012The Main reasons that this will happen\015\0121 - A bad run capacitor (silver or metal capacitor)\015\012It’s either shorted, grounded or open.\015\012If it’s short ... Danby DPAC8399 Air Conditioner

I have Goodman CPKE24-1AB that only hums when the unit is turned on inside. The fan works on the air handler portion but not the cooling tower/heat exchanger. It hums for a minute and will eventua


... Air Conditioners

I have a dometic dual-therm rooftop RV air with analog thermostat. When I set the thermostat to heat, the unit will hum but the fan does not turn and no air is coming thru vents in the floor. Then unit will blow cold air (hums and fan turns) when thermostat is on cool, but it won't turn off unless I shut it off at the breaker. What could be wrong?


... Dometic Rooftop RV Air Conditioner

Hi there, iwant some help in duct type air condition (trane)60000 BTU .when i was gave the out door freon i recognized that the high pressure fans were off and the compressore was on ,so i turn off the air condition for seconds then turn on i found that the high pressure fans run for one minute and then turn off and the compressore still running ,so what i shell do????


I hate to say this but it sounds to me like you need a professional. You may hear some other advice but it's not safe for anyone to work on the outside compressor unless they really know what they're messing with. The fire and death by electrocutio ... DeLonghi Trane 5t Rooftop Air Conditioner Ycy060g1m0ad

We have a new house and it came with central air. I have turned on the air and turned on the circuits and noticed that the outside fan on the outdoor unit was spinning round (good) now, I checked and the fan is not turning. Turned the unit on and off, still no turning and checkecd the circuit breakers...Any help please. Model is Aire_Flo Outdoor unit AFAIR12B30-A P I hear a low hum to the unit outside. I see trouble here.


First check to be sure the circuit breaker for the outside unit is not tripped. Turn the two pole breaker all the way off all the way off and then back on. If the outside unit still does not run you may have fuses in a disconnect box by the outside ... Air Conditioners

Problem I turned on my air conditioner this spring. I turned the switch to cool on and the air conditioner fan not going. I took cover off and got new capacitator didn't work. I took fan motor into electric shop and checked out fine. When I turn switch on the contact switch engages and there is a humming noise. But the fan does not work. the compressor doesn't start up. The model is at least 10 years old. How do we tell what the SER rating is?


Hi,\015\012There are two things to check....\015\012\015\012Do you have power coming into the contactor???\015\012\015\012Do you have power coming out of the contactor???\015\012\015\012If you have power goin ... Air Conditioners

Installed goodman air handler, system has hot water coil in duct for heat, how should i wier the 6006, or 4006 control to turn the fan on, on the air handler? if the limit switch turns the fan on for heat, isn't it going to send 24 volts back up the green wire to the t-stat? old air handler ( york) had a fan center relay.


\015\012\011\011\011\011\015\012\011\011\011\015\012\011\011\011\015\012\015\012\011\011\011\015\012\011\011\015\012\015\012\011\011\015\012\011\011\015\012You abso ... Goodman Air Conditioners

I have a CH&A Goodman AC outside. My Fan and heat work properly. My A/C wont turn On or the Auto Fan. But works with heat. Can push the 24V copper connector to turn on the A/C but when i let go it disconnects. Replaced the thermostatAlso even holding the Connection the auto fan on the pump wont turn on...


You need to check to see if the voltage is coming to pull the contact in, if not then you will have to check for the voltage at the air handler/furnace on the main board for the voltage. If the voltage is at the contactor then the coil is bad and you ... Goodman CKL49AR49 Air Conditioner

I have a Goodman CPLE42-1 split system. I had a power outage and my first floor unit would not cool anymore. The air handler/blower in the ceiling is working fine, but the fan outside is not turning on. When I went to look for an overload reset on it, I switched off the breaker on my second floor unit by accident, and now it is doing the same thing. Both fans on the outside will not turn on. Both thermostats will turn on the air handlers in the ceiling. Seems like I re-created the same exact pr


... Goodman CPLE24-1 Air Conditioner

Auto fan wont work .and when turn on air the compresser gets cold but fan wont run . fan turns free


... Dometic Rooftop RV Air Conditioner

On/off cooling when I turn air conditioning on it blows cold air for a little while then turns warm.I noticed the outside fan wasn't running all the time. when it's running the air is cold, when it's not air turns warm.


You will need to replace the outdoor fan and capacitor before it cause damage to the compressor.\015\012\015\012Thx\015\012RepairUSA ... Intertherm P3RA-048K Air Conditioner

Goodman outdoor a/c unit top fan stopped working while the family was away from home and now the compressor will not turn on. Only thing happening when a/c turned on inside is the indoor unit kicks on and the outdoor top fan begins humming and getting very hot to touch. Unit is only 5-7 years old. It is a Goodman CKL42-1L. Please, anyone with suggestions is appreciated. Definetly do not have money to replace the entire unit at this time.


... Air Conditioners

I have a goodman gsh130361 3 ton heat & air. It was installed 05/05/2008. all seemed well until cold weather, in 2009. The fan turns on and start blowing before the heat box is even warm. The heat set on 70----- when it gets 68 or 69 {in the house} the out side pump kicks in, 10 to 20 seconds later the fan turns on and blows freezing air into the house. the temperture will drop dramatically for the next 1 & 1/2 minute. The box will heat up and then all is well untill the next cycle.


The PCB unit that controls the thermostat and Coolant is malfunctioning... check that particular unit...that would help.... ... Goodman Air Conditioners

All electric apt 5 year old fan wont turn off when air is off


Sound like bad mercury switch or time for a new thermostat would be my first guess, second guess would be that the condensing unit needs to be cleaned out side. it might be frozen up, that happens when it gstarts getting hot outside. It might als ... Air Conditioners

When i was tested an air condition (trane 60000BTU duct type )i noticed that the high pressure fans of the out door unit were turned off and the compressor was running ,so i turned off the ac from thermostat for a second then turned on ,and look for the out door unit. I discovered that the high pressure fans turnned on for a one minute and then stopped, but the commpressor still running . What should i do ???/PLZ


... Air Conditioners

I HAVE 2 COLEMAN AIR CONDITIONSER ON A 2002DAMON INTRUDER MOTORHOME ANDTHEYAREON SEPERATE THERMASTATS. THEY WILL ONLY HUM WHENYTOU TURN THEM ON BUT IF YOU SPIN THE FAN, THEN TURN THEM ON, THEY WILL R


Your fan motor start windings are bad if you spin them and they work ... Coleman Mach III Air Conditioner

My central air conditioner turns on and only hums but fan does not turn and does not cool what could be the problem?


... Air Conditioners

Maytag air conditioner turns on but fan does not blow. When I put the unit to fan only, I hear the hum of the fan, but no air coming out.


Hi,\012Either the capcitor has gone bad for the fan motor or the motor has siezed up or gone bad... you cold try to replace the cap. first and move on from there....\012Here is a tip about troubleshooting your air conditioner... ... Maytag M7D24E7A Air Conditioner

A detailed question is important to get you a relevant answers