Having problems with your Air Conditioners ?

I have a dometic duo-therm. No air coming through ducts.

\015 I have a dometic duo-therm. The unit works great and fan blows strong and both high and low work., but air is coming out of the ceiling unit rather than the duct work. The bedroom unit works OK, but the air is strong out of one duct, and not much comes out of the others. The front unit only has air coming out on the A/C unit and none out of the ducts.\015

Answers :

I have a new Montana Mountaineer with a Dometic Duo Therm as well and experience something similar.
\015\012
\015\012It appears that there are two options:
\015\0121. Open the vents in the unit and all the cold air will blow out of the AC as that would be the shortest path and the there is hardly any air coming out of the ducts.
\015\0122. Close the vents in the unit and it will force all the air through the ducts.
\015\012
\015\012We let the air blow straight out of the unit during the day and then force it through the ducts at night to force it in the bedrooms. You could also open the vents in the unit part ways to get a combination.
\015\012
\015\012I didn't figure it out immediatly either, but just look close at the unit and you can see that you can close the vents on the unit itself
Sounds like the ducting have come apart in some areas or blocked in some way. Take the supply grills off and with a shop vacuum try and reach as far as you can.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a dometic duo-therm. No air coming through ducts.


I have a new Montana Mountaineer with a Dometic Duo Therm as well and experience something similar.\015\012\015\012It appears that there are two options:\015\0121. Open the vents in the unit and all the cold air will blow out of the ... Dometic Rooftop RV Air Conditioner

I have a 1992 Class C Gulfstream Ultra motorhome with a Dometic, Duo-Therm roof top AC system (ducted) model # 58915 and the old analog thermostat on the wall. The unit comes on and the compressor seems to be kicking in a few seconds later (just from the sound of it) but it's just blowing cool air. Not hot but DEF not cold! Do I need a new roof top unit or could there be a cheaper fix such as a known part that fails on these units? Hate to buy a whole new unit for 700 bucks plus labor if it's po


Well Paul I will do my best to save you any money I can. Have you checked the condition of the unit under the shroud? It sounds like you might just have a dirty unit and the cooling fins could be clogged with debris of some sort. There are many makes ... Air Conditioners

Crazy Heat I have a Dometic Duo-Therm Ducted air conditioner with a analog stat. Some times in order to make the heat work I have to: set the stat to cool and set it to the lowest temp setting. Then I set the stat to heat and a desired temp.The heat works fine as long as I leave it on heat. If I just set the stat to heat it does not do anything. This is a nine year old unit. This does not happen all the time. It seem it is getting worse. It happens more often now. Dometic said to replace the sta


I think that I would change out the thermostat only due to the symptoms you are describing. Think the control board may be fine however, the thermostat sounds as if the internal componants are going out. Good luck on your repairs\015\012 ... Dometic Rooftop RV Air Conditioner

My duo-therm forced air direct vent furnace will not stay lit. L-342465, model 65930-064. When I turn on the thermostat, I hear the fan, but then it starts clicking. Like it's trying to start. Sometimes it does & I feel warm air coming thru the ducts. But not all the time. It's in a 1983 Aljo 5th wheel trailer that I live in. Please help. It snowed this morning. Thank you, Brenda


I currently have the same problem. It's happened before and it was the circuit board on the right inside of the heater. Tired of that board going out ($) several times, so this time I'm going to remove the board and look at it myself for any common p ... Air Conditioners

Duo-Therm Brisk Air Model 59516.601 Ducted Roof Air w/wall thermostat


First of all, I think you mean 110 volts on your meter, not amps, just so we're on the same page. It sounds to me like you may have a capacitor problem on your compressor. I'll try to see if I can find you a part # if you have someone very experience ... Dometic Rooftop RV Air Conditioner

My duo therm dometic roof top air conditioner shut off and will not come back on. When turning on at the thermostat I hear a clicking but nothing else. Note that the furnace will not kick on either.


This symptom is in control panel circuit.The common causes circuit problem is cold solder or loose connection that why the machine funtion abnormally and it cause the machine to overheat and shutdown automatically and not turning on. The switch ... Dometic Rooftop RV Air Conditioner

Furnace problem I Have a 2005 Montana3295RK with a duo-therm air conditioner,suburban sf35f furnace and a dometic thermostat with remote. The problem lies with the furnace. It will not turn on, and in the rare event it does it will not turn off unless you either pull the fuse, turn the switch to the off position on the furnace or turn the gas off at the tanks. I can force the furnace to come on by pulling the fuse and then putting it back in and the thermostat does not have to be in the on posit


The problem is most likely in the control module of the roof air unit. Dometic uses the thermostat to activate and deactivate a relay in the control board of the roof ac unit whiich is just visible when you remove your air intake screen. The two blu ... Dometic Rooftop RV Air Conditioner

Dometic Duo-Therm air conditioner: keeps tripping the breaker. Unit is 4 years old. 57915-331 Everytime we use it; it cools the camper just fine but out of the blue it trips the breaker and won't work. Sometimes it cycles off and on, off and on. This unit is in a travel trailer, with a ducted system. suggestions ?


First clean the condensor with air blower or water pump and clean the filters.If the same problem persists there is a choke up in the refrigeration piping, cut from the discharge side and suction side flush the system with nitrogen, replace the filte ... Dometic Rooftop RV Air Conditioner

Duo therm furnace wont come on - Dometic Rooftop RV Air Conditioner


... Dometic Rooftop RV Air Conditioner

Duo Therm dripping water in camper when shut off. My Dometic Duo Therm Ducted AC drips quite a bit of water when shut off after running for several hours on hot humid days. The condensate lines are open. The lines drip steadily while the unit runs. When shut off the lines flow a great deal of water, suggesting that the pan is full. At this point I notice water dripping from the duct work. Thank you for your help!


Remove the filter at ceiling and run the AC on cool etc, and see if you can feel cool air leaking across to return air inlet where the divider between cold and return is. Check along all edges, etc for any cool air . Careful of wiring, but you should ... Dometic Rooftop RV Air Conditioner

My dometic duo therm brisk air RV a/c unit is not cooling the RV


I had the sam problem, took the thermostat cover off and tightend and refastend the wires, so far so god ... Dometic Rooftop RV Air Conditioner

I have a dometic dual-therm rooftop RV air with analog thermostat. When I set the thermostat to heat, the unit will hum but the fan does not turn and no air is coming thru vents in the floor. Then unit will blow cold air (hums and fan turns) when thermostat is on cool, but it won't turn off unless I shut it off at the breaker. What could be wrong?


... Dometic Rooftop RV Air Conditioner

My duo therm roof top camper air conditioner just shut off and will not come back on. Can hear a click when turning on now but nothing else. Note that heater will not come one either.


The click that you are hearing is the relay control board in the rooftop unit. This means that you are getting 12V to the board. It sounds like you are not getting 120V to the AC unit. Check the breakers in the breaker panel to make sure they are ... Dometic Rooftop RV Air Conditioner

My duo therm ducted ac not blowing cold air...has a flaky crusty black stuff on the inside coils of return air side?


You need to clean this section of coils badly. Get a plant or weed sprayer. go to a a/c parts supply store and get some coil cleaner. Tell the staff that you need something to clean the coils on your a/c coil. Tell them what kind of a/c you have a ... Dometic Rooftop RV Air Conditioner

Dometic rooftop ac - Dometic 457915 Duo Therm Brisk Air Conditioner


... Dometic 457915 Duo Therm Brisk Air Conditioner

We have a dual therm dometic air conditioner on top of a livestock trailer. Air only no heat. It has been cleaned and very clean filters. Always has worked great this year got ready to start up and will not cool. Compressor seems to be coming on but never cooling and there is no condensation like always before....do these take freon and how do you go about adding if they do? What is your suggestions


Unfortunately this will require some specialty tools and most people don't just have them in the garage. The unit definitely has freon in it or used to. These types of unit never tend to have valve you can add refrigerant through so someone must add ... Air Conditioners

Dometic duo therm a/c condensor model #59516 - Dometic Air Conditioners


... Dometic Air Conditioners

I have a Duo-Therm RV Roof Air Conditioner Model 57915.622, Prod # 991731648, Ser # 84818800. It will not run. I changed the Compressor and Fan start capacitors. When I turn the unit on at the Thermostat nothing comes on. The Air Conditioner Control Unit E155095, Part # 3107541.009. The fuses are okay.


... Dometic Rooftop RV Air Conditioner

Dometic Duo Therm AC Brisk Air 13k btu not blowing cold air


You can buy a saddle valve, this is a valve you screw in. I am assuming you have the correct freon as where you purchased your freon they should sell the saddle valve. Hope this helped ... Dometic Rooftop RV Air Conditioner

Have a duo therm ac unit that blows hot air - Dometic Rooftop RV Air Conditioner


THE REVERSING VALVE MUST REMAIN ENERGIZED ON A DOU THERM A/C IN THE COOL MODE IF A/C HAS HEAT PUMP BUILT INTO IT. IT WILL BLOW HOT AIR IF IT DOESN'T GET ENERGIZED. MAKE SURE VALVE IS GETTING POWER TO IT. TAP IT A FEW TIMES IF IT ISN'T AND SEE IF THAT ... Dometic Rooftop RV Air Conditioner

Duo therm rooftop air conditioner comes on for a few seconds then goes off in a little while it comes on and goes off again. please help. this is the first time the unit has been on this year


Unit likely low on freon cutting out on low pressure switch. ... Dometic Rooftop RV Air Conditioner

I have a Dometic Duo Therm rv Roof Air Conditioner Model# 59516.531.The fan is blowing and the compressor is kicking on but it is not blowing out cold air. Someone said it must be out of freon. Why would there be no freon? Can a technician add freon to this unit or do I have to change out the whole thing? please help!


These are a closed system.(meaning that there is no fill valves for recharging) But a heating & cooling technician can solder them on and re-charge the system. Only problem there is to get an estimate up front, and compare it to buying a new roof ... Dometic Rooftop RV Air Conditioner

My Duo-Therm RV roof-top a/c unit continues to come on and off when the system is turned off. No air blows, just the compressor runs for about a minute then shuts off. About 5 minutes later, it comes back on and does the same thing. Again, let me stress, the system is in the OFF mode.


Hi,The liquid line solenoid valve is bad and is allowing just a bit of refrigerant through it after it shuts off and the compressor pumps down....this causes the pressure to rise a gain and then the compressor comes on to pump down again. ... Air Conditioners

Where can I find a shroud for my 2003 model 59516.331 duo-therm high efficiency Dometic roof mounted dometic RV air conditioner?


Try googeling Camping world ,Adventurerv ,or best rv and truck supplies ,these are all in the USA who deliver to Australia.I usually find that it is much cheaper to buy parts like this from the US even with the delivery charge.Good Luck John ... Dometic Rooftop RV Air Conditioner

Manual for duo-therm brisk air - Dometic Rooftop RV Air Conditioner