Having problems with your Air Conditioners ?

My GE window air conditioner is making a loud harsh sound, I just turned it on for the first time this year. It did not do that last eyar.


Answers :

Best thing to do is to see if theres something hittng the fan blades,if thats clear the other that would make such noise would be the compressor,

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

My GE window air conditioner is making a loud harsh sound, I just turned it on for the first time this year. It did not do that last eyar.


Best thing to do is to see if theres something hittng the fan blades,if thats clear the other that would make such noise would be the compressor, ... GE Air Conditioners

I have a 10-year old Carrier Gas pack Model #48GS024060301. Turned on the heat for the first time this season and the unit did not turn on. I was able to turn on the house circulation fan and since it was a warm day today I also tested the A/C side and it worked fine. The inductor motor and fan were replaced last year. All the fins on the fan blade basically flew off on the first start up attempt last year. The entire unit, heating and A/C, were serviced within the last year by a certified p


If the induction motor ain't going I would look for a blown 3 amp (purple) fuse on the control board. If that was good I would check if any of the roll out switches were tripped. If a rollout switch was tripped check or air restrictions somewhere. ... Air Conditioners

A/C worked fine last year. Turned it on for the first time this year and the outside unit does not come on. The inside unit fan works just fine. I checked the circut breaker and turned on and off. No change. I revoved the cover and do not see any burnt wires or any problem. Not sure what to do next. I have a meter... what should the voltage be where the power comes into the unit at L1 ect. please help... thx


Check and see if you have 24volts at the contactor outside.if you do you have a bad contactor. if you don't take the tstat off the wall and take a jumper wire and jump out R to Y on the t-stat if i ... Air Conditioners

My fan and heater work fine, but today I turned on my air conditioner for the first time this year. It did not feel like it was getting cooler so I went outside and noticed that my outside unit was not working. I went and checked the breaker and noticed it was tripped, so I turned it off and turned it back on (the breaker). Then all orf the power went off to my house. I then reset my whole breaker box and I heard what sounded like my outside unit explode. I ren over to it and it sounded lik


You had a refrigerant release. Probably two lines rubbing together in the outside unit. I have repaired several of these with this problem. It involves repairing the lines by silver solderingthen pulling a vacuum/ purging with nitrogen an ... Carrier 36KCARMS Air Conditioner

I tried to turn on my air coditioning today for the first time this year and my Totaline Themostat P474-1050 won't turn on. Worked fine during the winter and last summer.


The thermostat is powered by the unit or batteries if batteries they may be dead if the unit you need to check fuses outside at unit or reset breaker outside depending on age of installation ... Air Conditioners

Lost manual- how to get another manual . It talked about draining water from unit. a /c hasn't been used at all last year and am just turning it on for first time this year. home-portland oregon


... Maytag Electronic Portable Air Conditioner Heat

When I tried to turn on my Daewoo air conditioner for the first time after the cold weather it sounds like the motor/compressor is working, but no air is blowing out/no fan activity. Is it time to get a new unit? It is about 7 years old...


No you may not you can check the fan's capasitor or you may have to get a new fan motor ... Daewoo DWC-056CL Air Conditioner

Hi i recently purchased a used convair portable supacool 9 air conditioner the first time i switched it on it appeared to work ok but the next time i turned it on it is working on normal fan mode but when i turn it to air conditioner mode it is doing exactly the same as on normal fan mode the compressor does not appear to be working and is not making the extra noise that it was the first time i have tryed all the switchs including the thermostat but there is only a very simple to use set up any


... Convair Portable Air Conditioner

8 year old Air conditioner only used in the last 3 years more than a week or two a year. capacitor changed last year Unit was working a week ago now fan is not turning, Connector clicks when turn on and off. when on I turn fan manually to see if motor might kick in and it does not. No lose wires. Quiet when turned on.


Outdoor units require there own power supply, check the breaker panel and the fuses in the disconnect switch box next to the unit if there are fused, If the capacitor that was changed last year was not the right rating or configuration it may need to ... Carrier 38CKC036 Air Conditioner

I am turning on my window air conditioner for the first time since last summer. Air is blowing but water is coming out of the vents as if water is inside.


Hi, what is going on is the unit is working good so you will have condensation running down the front of the indoor coil. You will have a trough at the bottom that has collected dirt over the winter and has clogged up the drain. Some window units hav ... Frigidaire FAC124 wall/Window Air Conditioner

I am turning on my window air conditioner for the first time since last summer. Air is blowing but water is coming out of the vents as if water is inside.


Get your AC serviced, due to dust and all the coils are choked this is the reason for water is comming out from the evtns ... Frigidaire FAC124 wall/Window Air Conditioner

I have a 2011 Wildwood travel trailer. I tried to use the air conditioner for the first time this weekend. When I turned the themostat to cool and 65 degrees the air unit "clicked" one time but the unit did not start. I tried various settings but nothing. When I turned the thermostat off the unit clicked one time again. This is a brand new trailer and the first time I tried the air. Any thoughts?


First thing to check is that the breaker for hydro to AC unit is in the on position. The clicking sounds like 12 VDC is OK but hydro may not be on to it. ... Dometic Rooftop RV Air Conditioner

We purchases a Haier portable air conditioner CPN11XCJ last year via QVC. By the time we purchased it, we really didn't need so stored it unopened. Opened it up last week due to extreme heat for this time of year. I just plugged it up near an open window and it the cool air was wonderful. However, when my husband installed the hoses and window screen, the thing rattled awfully. I mean a very loud rattling noise like the compressor was having problems. If we take the hose off, it doesn't rattle b


There are only a couple of things that could make it rattle with hose installed. One, if the hose cuff is somehow extending through the grate on the unit and making contact with the fan or there is probably some sort of a fitting, like a dryer vent, ... Air Conditioners

It happens every year. The heater will work, then when I really need the heater, it stops working. First I will set the thermostat. Then The heater will sound as if it is turning on. It doesn't. It does 3 times before completely turning off. After 10 to 20 min, it will try to turn again, but does the same thing. This has happened every year for the past 5 years. What can I do?


This is very tricky because it could be one problem or a combination. first check to make sure the igniter is working. you may have the hot surface igniter, standing pilot or the direct spark ignition. if you have ignition then check the air pressure ... Air Conditioners

I have kenMore window air conditioner model 70121 i bought last year it worked last year and when I when to use it this year I keeps tripping the rest button I have rest the button several times but


... Kenmore Slider/Casement Air Conditioner

Tempstar 5000 This spring I turned on my air conditioner for the first time and it would not start at all... The fan did not turn on either. I turned off the main 220A breaker and puller the control fuses and put everything back and the unit started working fine. now fast forward to yesterday... house started feeling warm so I did the same thing... Tripped the breaker. Pulled the control fuses, and this time made sure I had new batteries in my thermostat. Started to work again. All was good. pus


... Air Conditioners

I have a ceiling fan with lights, last night the fan was turned on for the first time since summer, the remote is over the light switch. The remote to turn on the lights is used normally. Since turning the fan on last night there is now a humming noise even without the lights or fan on. Is this a problem with the fan or remote. pleas help the noise is low but consistent.


There is a small relay in the ceiling fan causing this noise, try turning off all power to the ceiling fan and allow it to set for a couple of minutes. Turn it back on and see if it goes away. If it does great. if not, it may not be worth the repair ... Hunter Air Conditioners

I have 4 header split type air conditioner. Time & again it stops and operation and timer light flash altenately and I have to to turn off the power at the switchboard and turn on again to reset. Sometimes this happens 2 or 3 times a day and other times it operates correctly for days. I have cleaned the filters and checked the electrical connections. 2 years ago I had a tech from Fujitsu who came and checked everything and could not find any faults. I am getting a bit concerned as this is occur


Hi,\015\012On the days it happens alot is there a temperature corolation??? Are these days warmer or colder then the days it runs all of the time???\015\012\015\012Have you checked the charge on the unit???\015\012Would there ... Fujitsu Air Conditioners

Problem with a water dripping Air Conditioner.. I bought a New Plasm Aire Conditioner, Model Number: 580.750652500 last year and it was working great. Now this year I installed it and it continues to drip water from the front of the unit all the time and on all the mode settings. What is wrong with it and how can I stop it from dripping?


You need to reposition it to where the rear of the unit is tilted slightly down. So that the water will run down and out the rear. ... Kenmore 75051 Wall/Window Air Conditioner

Problem with a water dripping Air Conditioner.. I bought a New Plasm Aire Conditioner, Model Number: 580.750652500 last year and it was working great. Now this year I installed it and it continues to drip water from the front of the unit all the time and on all the mode settings. What is wrong with it and how can I stop it from dripping?


THE "DRIPPING" is normal but The Unit Must be TILTED Towards the OUTSIDE SO THE cONDENSATION CAN drain OUTSIDE ... Kenmore 76100 Wall/Window Air Conditioner

My 3-year old LG air-conditioner was leaking water. So i called some 'experts' to come fix it. This is the first time I called for maintenance service on the air conditioner. The 'experts' dismantled some parts of the air-conditioner and washed out a lot of dirt and sticky stuff. After they put the air-conditioner back, there was no more water leaking but I noticed 2 new problems. When I switch on the air conditioner, the mouth does not immediately swing open, it takes about 3 minutes before it


White snow.. I had this issue when 2 inside unit electrical lines were hooked up backwards at the compressor. The compressor would pump too often and overcool the inside unit, because it was using the wrong temperature sensor. But you could have a ... LG LS-L1210CL Mini Split Air Conditioner

I bought a 5,000 btu sunbeam air conditioner last year. When I turned it on it is not working and it was covered .


... Air Conditioners

Turned on the a/c for the first time this year and no fan. The compressor turns on but no fan. The fan works when turned to heat and t-stat cranked up. This is a BDP CO. 2085C02135. Is there a relay or limit switch that only works with cool?


Depending on the thermostat you have, there may be an issue there. Some stats have a subbase that controls the fan for AC. I would like to know the model of your stat ... Air Conditioners

I have split dual zone art cool air conditioners. Both worked this morning when I turned them on for the first time this season. I came home from work and nothing. I checked power sources and reset remotes. On both art cool screens is the temperature and "ch" flashing back and forth. The remote will turn it on for a split second and then turns off and goes back to flashing. Help! Thanks Bianca Zick


... LG Air Conditioners

Model G51MP-48C-110-6; I've downloaded a manual and troubleshooting is usually fun for me, but ;( this time. It ran fine last year, not this fall. Have alternating Green & Red code lights (FAST); I have checked thermostat; (and completely shut off, restarted power and gas several times too; each time goes back to "normal' simultaneous, slow flash until I turn the thermostat up to call for heat; then FAST, alt. Flash again), good ~25vac signal calling for heat. Have drained condensate from trap (


Apply power to the inducer motor, or check the voltage to it first.a relay or circuit board will control its operation, if the inducers not running, the pressure switch wont close and no operation . ... Air Conditioners

A detailed question is important to get you a relevant answers