Having problems with your Air Conditioners ?

WHEN THE HEATER COMES ON THE FAN STARTS INSTANTLY AND BLOWS COLD

\015 MY HOUSE IS NEW AND SMALL, THE AIR AND HEAT IS A GOODMAN UNIT. EVERY TIME THE HEATER COMES ON THE FAN STARTS INSTANTLY AND ALL THE COLD AIR IN THE DUCT WORK IS BLOWN INTO THE ROOM. AFTER A FEW MINUTES (ABOUT THREE MINUTES) THE AIR WARMS AND THE TEMP. IN THE ROOM COMES UP TO THE SET TEMP AND THE UNIT SHUTS DOWN. THE NEXT TIME THE UNIT KICKS ON IN COMES THE COLD AIR AND CHILLS THE ROOM. \015\012 I HAVE HAD SEVERAL BRANDS OF AC. IN THE PAST BUT NEVER ONE THAT DID THIS AND THE HOT AND COLD IS NOT VERY PLEASANT. THIS UNIT IS LESS THAN ONE YEAR OLD.THE INSTALLER SAYS NOTHING IS WRONG. CAN THIS CONDITION BE CORRECTED?\015\012\015\012 BILL THACKER\015\012\015

Answers :

Do you have a heat pump? If so this is normal. You are probably used to a gas furnace. There are heat pumps that do have a delay though. Look on the circuit board in the air handler. There may be a set of pins that say 0-30-60-90 yours may be at 0. Also some digital T-stats offer that function for delay off to get the extra heat or cold from the system. Find out what the model number of the air handler and call the Goodman supplier in your area to see if you have these options.
If you have a gas furnace and it's not delaying the blower there is definately something wrong.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

WHEN THE HEATER COMES ON THE FAN STARTS INSTANTLY AND BLOWS COLD


Do you have a heat pump? If so this is normal. You are probably used to a gas furnace. There are heat pumps that do have a delay though. Look on the circuit board in the air handler. There may be a set of pins that say 0-30-60-90 yours may be at 0. A ... Goodman Air Conditioners

Have an amana central air duelfuel heat system.when aux heat[gas] heats the house and shuts off the fans still blow for 3 to 5 minutes with the last couple of minutes being cold air which cools the air it just heated. also heatpump will start heating when it comes on then after 3 or 4 minutes it starts blowing cold air like when the air conditioner is running.i have had problems from day of install 4 mounths ago with problems that keep coming up. please i need help fast i do not think comp


Change your heating delay to shut off sooner, you can find this in the installation manual. Also the Thermostat may have delay after heat as well. It is true there could be many variables, but it also sounds like the Heatpump is not charged properl ... Amana Air Conditioners

Airflow We have a new ducted PEH-MYB reverse cycleairconditioner. We set the temperature at 20 degress for heating. Once it reaches it it then blows out cold air. We have had someone come 4 times already to fix various problems. It is not nice to sit near a duct and feel cold air. I thought the air flow was meant to stop, then start uo again when the temperature dropped just like our gas heaters? Am I wrong?


Go to www.mrslim.com. Look under the tab for library. Ib there you will find the troubleshooting guide for this model. Make sure the remote is set for cool and make sure the fan setting is not on automatic. ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

I have a york hvac system that is 5 years old. I have the thermostat set at 74 and when it turns on only the fan runs circulating the existing air in the house about 20 percent of the time. The ac works great when it is running but i'm wondering why it doesn't always come on. Just replaced the thermostat thinking that was the problem but it did not help. Sometimes after the fan runs for a half hour or so the ac will finally kick in and start blowing cold air. The lines are not frozen at a


It sounds to me like you have a delay on start timer on the compressor that possibly is starting to fail or someone may have adjusted the time band up on it. I myself would remove it and install a delay on break timer and a 5 minute setting would be ... Air Conditioners

My car heater was not blowing warm air so i changed the thurmastat then took it for a ride the heater was still blowing cold air the car temp went up and blew a hole in my headgasket so i fix the water pump and this weekend im gonna fix the head gasket and it all started with my car heater blowing cold air what do i need to fix to get hot air in my car heater


The heater uses water that circulates from two positions on your car engine. One is the inlet hose and the other is the return hose. they are usually about 3/4 hoses clamp to two nipples on the heater that extends through the fire wall. If those hose ... Air Conditioners

Have NEC RIH-2667 Inverter Split system.I set to Heating mode,set temp to 25 degrees.The compressor light comes on.The run light flashes for about 30 seconds.Then the vent opens,the fan comes on and starts blowing out heat.Within 5-10 mins the temp on split displays starts going up.when it gets to 26-27 the run light flashs,fan stops,no heat coming out.The temp on system keeps going up to 30 degrees.it takes approx 40-60 mins to come down to 25ish the will come on again and repeat.I have an inde


... Air Conditioners

I have an XB10 Trane AC unit that was installed when my house was built in 2003. After running it for a while, the compressor either seems to shut down and I notice no cold air as though its just the fan. Sometimes when I start it back up my thermostat says ''wait''. Or it just blows the fan, even though its set for cold. I've had the capacitor replaced, a start up capacitor bridged to it. I've changed the filter and had the coils cleaned with a brush and garden house from the inside. I'v


... Air Conditioners

Danby DB98-26786A window air conditioner will start up and blow cold air..frost forms on the tubes..after a few minutes the frost disappears and the compressor shuts off .. the fan still blows; but no cold air ..the compressor doesn't start again unless it is turned off for quite awhile


Hi,Here is a tip about troubleshooting your air conditioner...\012There are many things that can cause your air conditioner not to cool... ... Danby Air Conditioners

I recently had a new outdoor unit installed on my central heat and air conditioning sytem. I have had the installer out 3 times and the system still does not operate correctly. Sometimes when it cycles (every other time or every third time) the unit does not blow cold air. Sometimes the unit comes on not blowing cold air and the compressor fan is running but not the compressor. Sometimes after 15 minutes of this the compressor will come on. What is the problem.


It sounds like the compressor needs starting components installed on it. All a/c units have a run capacitor for the compressor and another one for the condenser fan motor. These motors use these capacitors all the time when the motor is running. H ... Air Conditioners

Unless we set the thermostat very high, like 80 degrees, the heater will blow cold air. When the heat does blow, it will eventually stop blowing heat and the fan will continue to blow cold air.


Check and make sure the filter is clean. This sounds like a restriction in the system. If the unit has central cooling make sure ther indoor evaporator coil is clean at the furance.The unit may be cycling the burners on and off at the high heat limi ... Air Conditioners

When I set tstat to call for a/c, compressor outside comes on. Blower on furnace does not. When I manually rotate fan limit switch on furnace wall, blower comes on, blows cold air, and then goes off when I release the fan limit switch. I have a Honeywell 83251008a low and high voltage transformer, and Honeywell (I think) limit on off switch. I also noticed the 2 wires coming from the Honeywell Gas regulator are off. They were connected at the onset of the problem. I am not sure where to re


Sorry, you mean gas valve control? when you have only 2 wires, usually it doesnt matter which terminal as there,s no polarity differentiation at that locationYou should never rotate this dial by hand, you will bend the helix inside and fan will not o ... Air Conditioners

My honeywell heater is blowing cold air, could it be the thermostat? It did the same thing yesterday and eventually began blowing heat, then late last night started blowing cold air again.


Not sure what type of furnace you have but here a a few easy tips: ... Air Conditioners

My unit is running but not blowing cool air. I went outside and the condenor fan was not moving. Took a stick and shoved a blade and the fan started moving but the air is still not cool inside. I did notice the air coming through the unit outside after fan was blowing was cooler than my 2nd a/c unit that was working fine. I wondered if the entire unit was frozen. I turned off unit at thermostat and figured I would see what happens tomorrow


Sometimes on new units it is common for the fan to not start until you give it a push. Did you happen to hear if the compressor was operating? If the unit was froze-up the Insulated Suction line would also be iced over as well. If it wasn`t it is mor ... Carrier 38CKC024 Air Conditioner

I have a frigidare FAM157S1A Air Conditioner, when plugged in the fan blows air but not cold air. Compressor not working, I pushed control panel to cool air, blows cold air for a few seconds, then unit blows the breaker. How do I fix it. It has been only used for two weeks and this started.


Your compressor motor is no good Time to replace unit ... Frigidaire FAH085N1T Air Conditioner

Weather King 10AJA3001AH Air Conditioner Heater if the heater has been off all day i come and turn it on it works fine but when it comes on again it only blows cold air the burners will fire for about 2-10 seconds right before the blower comes the fire goes out it repeats this for about 5-6 times then it just goes off, how can i fix this problem


I think from the erratic way that your furnace is functioning that you will need to replace the control board to solve this problem. Ihave had this happen several times and I would recommend that you check all connection on control board,gas valve ,i ... Weather King 10AJA3001AH Air Conditioner

I have two Friedrich PDE15KSB-C units. When trying to turn on the heat neither will kick into the heat mode. They both blow cold air only. When they are first turned on the air blows, and there is a click sound as though the unit is trying to start the heat pump, but then nothing really happens...just the fan continues to blow cold air. Any help would be appreciated. BTW the dip sticks are all in the positions of 1234 ON, 5678 OFF - factory setting. I did try to turn 7 on for the emergency


Keep +10 degree from your room temp and also thermostat in "heat" . And then check. But in your case, I think RV not energized. If no proper voltage in RV in heat mode, check the wiring to RV. If voltage in means RV not working properly. You have to ... Friedrich PDE15K3SB Portable Air Conditioner

Had a Kelvinator KSV80HRA Rev cycle split installed months ago. It goes to defrost mode when turned on and doesn't start up. It is set to heat but blows a stream of cold air downwards towards the wall but no fan is blowing. Can you help me to set it straight the nights are getting cold !


Hi\015\012It sounds like a sensor issue that means problem with thermistor or thermocouple although it may be the controller board.Unless you know how to work on equipment like this, I urge you to get a professional t ... Air Conditioners

Help... My problem seems to be my furnace works fine if i manually cold start it but once my unit gets hot it wont restart the jets wont stay lite and the fan will not come on but if it hasnt been running and is cold its starts fine ???


If you were experiencing a failure just after a heating cycle but not on a cold start, I would suspect an electrical component failure. As the component cools, it makes contact and allows the furnace to operate. This will change and not for the ... Air Conditioners

I have a goodman gsh130361 3 ton heat & air. It was installed 05/05/2008. all seemed well until cold weather, in 2009. The fan turns on and start blowing before the heat box is even warm. The heat set on 70----- when it gets 68 or 69 {in the house} the out side pump kicks in, 10 to 20 seconds later the fan turns on and blows freezing air into the house. the temperture will drop dramatically for the next 1 & 1/2 minute. The box will heat up and then all is well untill the next cycle.


The PCB unit that controls the thermostat and Coolant is malfunctioning... check that particular unit...that would help.... ... Goodman Air Conditioners

Have a coleman presidential II electric furnace, when I turn it to heat it comes on and the fan starts blowing after about 30 seconds the fan shuts off--can feel heat from the funace but none coming o


... Coleman Mobile Modular Home Electric Furnace Eb10 Eb10c

AC unit outdoor fan motor does not come on as it should, but if I manually start the contactor relay / coil by pressing and holding the manual button on it the fan then comes on and goes off with the thermnosat; however, the air stays cool (that is blowing outside) and warm inside. The large capacitor does not look bad though.


It sounds like the contacts of the contactor are burnt/pitted. When this occurs, it can allow enough current to operate the fan motor but not enough to operate the compressor. ... Carrier 38CKC036 Air Conditioner

It is not cold. The fan works but when the cold air should come on it doesnt. You can hear it trying to kick on for a moment but it doesnt, it just keeps blowing as a fan. Thanks for any help. I would even buy another one of the same model if I could find it but that doesnt seem possible either.


If compressor is not shorted out to the ground and between each leg of compressor multimeter reads resistance You could try to install 3 N 1 hard start kit. But most likely compressor is weak, be prepared to replace compressor soon. Here is my situat ... Frigidaire FAS185M2A Air Conditioner

My unit stopped blowing cold and started blowing hot.i turned off unit looked into furnace and saw pilot was still lit.i put out gas pilot and turned unit back on and it is blowing semi cool air (like fan)but not cool as it should.checked outside ac and it is running....munual says to turn unit off for 2 hrs and if it does not do right then it is compressor.we are currently in the 2 hr process. Any help would be helpful at this point.is there a reset switch or anything I could do to troubleshoo


100 degree temps/high humidity puts an extreme load on air conditioners - but if everything is right with the AC - 'overheating is not a big problem.\015\012\015\012The first thing I would check is whether or not the compressor is running ... Weather King 10AJA4201AH Air Conditioner

SAME PROBLEMS 18k btu mini-split sys turn on blowing cold air for 3 mins, then turns warm for 3 mins then shuts down however the run lite blinks at 4 times intervals. outdoor unit fan alway runs at slow speed, even at start up. cleaning outdoor fan cleaning dont help. whats next? maybe the caps? thanks mike (us navy) at [email protected] in norfolk,va FAN MOVES FREELY, EVEN BY WIND BLOWN.


Glad to hear the issue is resolved.\015\012\015\012With regards. ... Air Conditioners

Purchased a fedders a/c 18000 unit still under warranty. called the 800# they said company had filed bankruptcy and were not responsible for repairs. 350$ mistake. Fan runs too slow for unit to kick in. Fan will pick up speed some times when you turn it on, will start to blow cold air but only runs for a couple of minutes before fan stops turning.


Check the capacitor for the fan motor. You can do that with a multimeter with the capacitor test function or if the capacitor looks swollen then it is probably bad. Also, make sure the fan rotates freely by hand. Let me know if you need more help. ... Fedders 12,000/10,200 BTU Heat/Cool Room Air Conditioner - White

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific