\015 How can i get info to change my a/c control unit from manual to digital? i have a 02 maxima 3.5.\015

Answers :

Go buy a new thermostat and follow the directions in the package. The wires are pretty simple. R terminal is power, W is heat, Y is cool, G is fan, C is common. On a typical thermostat you will have all these with the exception of the C term. It will either be RC and RH with a jumper between them. Leave the jumper in if you don't have a 5 wire system. Make sure you lable your wires coming out of the wall because you don't want to have to open up the indoor unit to check them.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I need to know what the wires are on the 6 pin harness for this control specifically what each of the wires are for


R-Red C-Block = 24 vts. Y1-cool-1 green, Y-2 Cool2-yellow W-1-heat-white,1 W-2 Heat-2-orange ... Air Conditioners

A/c control wiring harness


Go buy a new thermostat and follow the directions in the package. The wires are pretty simple. R terminal is power, W is heat, Y is cool, G is fan, C is common. On a typical thermostat you will have all these with the exception of the C term. It ... Weather King 12AJA4801AH Air Conditioner

Intertherm G4RK096C-16 Gas Furnace Fan not cutting in during heating cycle. If we wiggle the wires, fan cuts in. Some time ago during servicing, a variable speed control for the fan was installed. There is now a red wire going to the fan connector on the control panel and a blue wire with a spade tip is taped off. If we were to disconnect the variable speed control, which wire (red or blue) should be connected to the connector on the control panel?


... Intertherm Air Conditioners

Broken wire from wire housing to top control panel of AC Unit


Bad stuff dude, you are going to pay about the same for the part as the unit, unless you learn to bypass that and put it on a light switch, black wire to fan and black wire to compressor on one side of the light switch on the other side the "hot" wir ... Air Conditioners

I have a Nordyne MGHA-056ABFC-05 furnace. It currently uses a 624567 2 wire control board and 2 wire thermostat. Can I use a Nordyne 902987 relay control box (uses Nordyne 624625A control board) to connect a 4 wire thermostat to it?


You could use a $10 relay ... Air Conditioners

I have just replaced a Sunvic SP 100 Controller, with a Siemens RWB29 Controller, and find it is not working properly. It has been wired in correctly, according to the 'Change Over Wiring Diagram' supplied with the new Unit. However, when I turn either Hot Water, or Central Heating, on to 'Manual Overide', it comes on only for about 40 seconds, and then the Gas Fire goes out! Consequently, the Water or Heating NEVER GETS HOT! The Wiring has been checked by a qualified Electrician. W


... Air Conditioners

I have a DuoTherm BriskAIr 13.5K BTU. The Dometic thermostat also controls my HydroFlame 8531-IV furnace. This morning, the furnace would not come on. I checked the wiring and there is no voltage at the thermostat blue wire on the furnace. If I jump 12 volts to the thermostat blue wire, the furnace works normally. Replaced thermostat; no change. I hear something clicking in the air conditioner unit when I switch the thermostat to furnace mode. I assume the A/C has a relay to control the thermost


If you look at control box at roof unit, they usually use a separate set of wires for furnace. See what colors they are attached to at harness to thermostat. Some just follow other harness, and come out at thermostat. (bypass control box) Once you've ... Dometic Rooftop RV Air Conditioner

I can not control my furnace. The handyman pulled all the control wires off trying to fix it. is there a standard way of wiring the control of a furnace. I need to hook up the Bryant Magnetic Diaphragm Valve to the thermostat, power source, hi temp safety switch and pilot. The system runs on natural gas. Valve is model ib634. Thank you for your assistance. Sincerely, Jack Cohen, Mananger Apex Property Manangement, LLC tel: 610-656-2401 e: [email protected]


... Bryant Air Conditioners

I have an older Carrier Heat Pump which I am trying to update the thermostat control with a Hunter model 44550. The problem is that the wiring to the current thermostat is as follows, G= green wire, R= red wire, W2= blue wire, O= orange wire, Y= yellow wire, E= grey wire and C= white wire. If I am reading the schematic correct for the Hunter thermostate I am to wire as follows Green to G, Red to RC, Blue to W, Orange to O, Yellow to Y/Y1, C cap it as batteries are used. It does not tell me


JUMPER STAYS BETWEEN RC AND RH SO YOU HAVE INCOMING POWER FOR BOTH COOLING AND HEATING. THE WHITE WIRE YOU SAID C IS COMMON AND SHOULD BE USED IF POSSIBLE TO COMMON TERMINAL ON NEW STAT . IF THERE IS NO COMMON, THEN CAP IT BUT YOU'LL BE CHANGING BAT ... Carrier Air Conditioners

I am replacing the a/c blower motor and capacitor. The old motor has 1 brown wire to the capacitor, 1 yellow wire to the capacitor (the yellow then loops from the capacitor over to the wiring panel), 1 green wire to ground, and a black wire that comes from the wiring harness from the wiring panel. The black wire is plugged into a small white box on the side of the motor that has a port with three places to plug in wires. These are labeled black, red, and blue, but only the black is there, no red


\015\012Motor Wiring\015\012Old Motor\015\012Brown wire is Start\015\012Yellow wire is run or Power\015\012Black wire is High Speed or Common\015\012The other two taps are speed taps, but you have a single speed ap ... Air Conditioners

Need wiring help on wiring a 1994 Marine Air system to a Cruiseair SMXII control box


... Air Conditioners

This is for a williams top vent wall heater, with the wires conected to the gas control body, the pilot is lit but when you set the thermostate to say 70 the pilot lite gos out, there is also a heavy black wire that shows it going to the bottom of the gas control body that we connected to that bottom screw it shows that it comes from the thermostate to the bottom of the gas body and its perpose is for the top vent sensor


... Air Conditioners

Purchased a dometic duotherm a/c for rv partially installed it, but conected all the correct wires and it will not turn on. All new unit with new thermostat and control box. the Thermostat requires 7.5v dc to function but the control box is not producing the voltage. None can be detected on the terminals of the thermostat. there are two wires for an solar/filter indicator that should have +12v and a -12v. neither have any voltage present. tried to return the whole system to the vendor bu


Check all grounds,all grounds,I stress this because the system may need ground elsewhere to operate.If the control box is what produces the 12 volts dc,and the 7.5 volts dc,and you have power to the box,then the box(converter)is bad.Is this unit 120v ... Dometic Rooftop RV Air Conditioner

LENNOX HS26-048-3P Installing Honeywell wifi thermostat. C terminal on control board was connected to X on the old thermostat. The X terminal wire on the old thermostat is connected to the C terminal on the control board. I used this wire to connect to the thermostat C terminal and now the compressor fails to come on. The slow flashing lights indicate the thermostat is asking for cool and the fan comes on, compressor does not come on.


... Air Conditioners

T-stat problem I am workig on a 92 intertherm.Trying to install new stat to control heat and cooling. top of control panel only has C Y W R were does the fan wire (green) connect ? the only #s I have togo by are 901698-2wire relay box


HEY, the only logical explanation is, that unit didn't have fan only. ... Intertherm Air Conditioners

I have an apac ducted splt unit with a lock out relay that pulls in straight away despite all safetys been ok. it is a 2 stage unit and the hp/lp controller on stage 1 is faulty, with the wires bridged out on the pressure controller the relay pulls in straight away and with the wires seperated on the pressure switch the lock out relay doesnt puli in,any ideas ?


... Air Conditioners

Hi I have a Rinnai 1004. I asked a question before about clipping the temp gauge and adding a length of speaker wire in, so that it would get a more accurate 'room' temp reading. The reason for this is that I can't get to the controls to manually change the temp. I have a few other thoughts and want to know if anyone could add to the ideas: 1. Could I add that speaker wire to the 'control unit' and mount that in a more convienient place?? 2. Would a 'plug in' thermostat work?? Some


I'm sorry. the thermostat is not in the "Temp gauge" It is inside the unit. As well, Modifying this unit can make it unsafe. As well, if one were to use wire to extend the control unit, you would want to use thermostat wire. However this ... Air Conditioners

Lennox 10ACC-048-230-02 Blows 40 amp breaker like right now. Opened up outside controll panel and found a mouse nest. Wires stripped and shorted. Rewired bad wiring and unit still blows breaker. Good resistance check from disconnect to control box. Fan will start and run if i disconnect compressor. Sounds like......


... Air Conditioners

How to wire a aquastat controler immusible type with a flotect switch to a millivolt thermopile.flotect has two wire,aquastat has two wire also the thermopile has two wires i have wireing from valve to the burner. what i need to know is any of those wire plus or minis


Don't waste my time ... Honeywell Air Conditioners

I installed Minka remote controlled Ceiling fan for a friend. The fan itself has 4 wires, black,orange,white, & blue. The remote unit has black, white, & blue wires to connect to black, white, & blue wires on fan, and black & white wires to connect to electrical wires in attic. The remote operates the fan functions correctly, but the lights on the fan stay on all the time, with no effect from the remote. I have no manual, and had no place for the orange wire on the fan to go to.The model number


The connections you need to make are \015\012\015\012\015\012Motor to Receiver Electrical Connections: Connect the WHITE \015\012wire from the fan to the WHITE wire marked "TO MOTOR N" from the \015\012Receiver. Connect the BLACK wire from t ... Air Conditioners

Intertherm furnace heat pump combo had a small fire in the control wiring when a contactor for the heating elements burnt. I am an electrician by trade and have replaced all the wiring and contactors but half the schematic was burt and I now have 3 wires from the transformer that I can not tell what they go to. I need the drawing and hopefully help on landing these 3 wires from the transformer.


Ok the transformer has a common which is black the second wire red is coming from the contactor side at 240 volts the last wire on the side opposite the common and 240 connection goes to the 24 volt side of the contactor. Hope this helped ... Air Conditioners

I have a remote comfort control with 3308448.004 relay board. Press Heat button to turn unit on and it does NOT turn on. Have 115VAC to the relay board and have 12VDC to remote control reciever. Sounds like the remote control reciever is bad?? Can I switch my system to the "wired" control system without changing the relay board? I assume it is possible that the relay board is also bad. Is this a common fault with these units?


... Dometic Rooftop RV Air Conditioner

Replacing a tekelek speed controller 400 with the 467, wanting to know the differencess in the white loop wire and the black fan wire and the blue fan wire and where these wires are planced in the 467?


... Air Conditioners

I have a Bryant Air Conditioner 561CJ024-E and a Bryant furnace. The furnace control board is not sending a 24V signal to the outdoor condenser and fan unit. Is it possible to trouble shoot the control board itself or do I need a new control board? All control wiring from thermostat and outdoor condenser looks correct.


... Air Conditioners

What is the wiring diagram for the Honeywell Aquastat controller? The ZR and ZC wires on a diagram. Which wire is power for burner . and there is a fourth wire . what is that?