Amana air and heating unit model # ptc153b50am w/ power cor 37470

\015 Power cord reset button keeps popping and cutting off unit, power cord model is 37470\015

Answers :

Sounds as though the power cord reset switch might be bad and need to be replaced. If not, then there is a short somewhere in the system. Do an ohms test on the switch to determine if it is bad.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Amana air and heating unit model # ptc153b50am w/ power cor 37470


Sounds as though the power cord reset switch might be bad and need to be replaced. If not, then there is a short somewhere in the system. Do an ohms test on the switch to determine if it is bad. ... Amana PTC153B50AM Split System Air Conditioner

I have an Amana Model GUC-C 90 Hi-efficiency furnace that we installed in 1992. It has a central air unit as well. On Friday we tried to turn the air on and nothing will work. I have replaced switches in the air unit in the past but this time there is no clicking, I can't turn the circulation fan on for the unit, the heater unit will not turn on. I have power at the breaker, and on the unit itself there is a on/off switch with a round screw in fuse, that fuse is good and I have power there.


Hello,Your control transformer may have quit on you, or your thermostat may have gone out. The transformer is what supplies the current for the hvac system. The thermostat just controls what relays are energized. Since you have a probl ... Air Conditioners

Have a Amana Wall Unit with Heating and Air Conditioning - Model PTC123B50AE. The unit's heater just stopped heating. The fan/blower and air conditioner are working fine. Unit says the fuses are OK. Would appreciate any guidance in fixing this unit. Thanks, NC


PLEASE CHECK THERMOSTAT SETTING +29 AND ALSO MODE"HEAT". STILL PROBLEM \012CHECK THE HEATING SENSOR IS NOT OPENED. BY A OHMS METER CHECK THE \012SENSOR. iF ANY READING IN OHMS IT'S O.KAY. ... Air Conditioners

No heat I have an Amana heating and a/c unit model # pth153b50ae. It was blowing heat all winter then just stopped. It now blows cold air and is either bringing in cold air from outside or is blowing a/c. It does not change no matter where the control knobs are set. I checked the fuse and actually changed it but no difference. The only way I can turn it off is either unplug it or take the cover off and switch of the little micro switch. I'm thinking the board is gone. Any help would be appreciat


Check to see if unit has a contactor,they arc and weld together,keeping your unit on ... Amana PTH153B50AE Air Conditioner

Hi, I have a wall mount midea split a/c model- MSG-36HR that will only heat. when put in cool mode it only blow's room temp air and the outdoor unit won't run. On heat mode it works normally. I have cycled power a couple of times, changed modes on the remote numerous times and just in case, changed the batteries in the remote. The unit is about 3 yrs old. Do you have any pointers. Cheers Tom


Most heat pumps are 'fail-safe to heat'. That is: the normal position of the valve which reverses the function is in the position which provides heat. The reversing valve must be powered to switch to the cooling position.Although the ... Midea Air Conditioners

I have an Amana central air/heat unit. Model PHCB10C1 Serial # A040900070 Manufacture # P1219409C, Cat # 81K95. The problem I am haveing is the unit will not kick in(heat). When I turned off the main pwer and let off for about a hour and turned back on the unit ran fine for a couple days. Now the unit will not kick in at all even after turning the main power off and on to reset the unit. I have a brand nre thermostat in the house. When I turn the fan from auto to on the fan runs and blows out


... Amana Air Conditioners

Hi I have an NEC Split Air Conditioner. Model RIH6867. Power rating - 6.8Kw Cooling Capacity 8.2Kw Heating Capacity. Single Phase for 240Volt environment. I only have the outdoor unit. It is new. But missing the complete indoor assembly unit and remote. Can I substitute other indoor units to make this work. NEC no-longer supports their appliance division. Regards Ash


Hi Ash,Off the cuff, I would say no to being able to use any other indoor unit. But, with a bit of work and research, you might be able to connect 2 systems, even if different manufacturers, together. The compressor / conden ... Air Conditioners

No heat my unit is a Amana model pth153b50aj the unit blows cold air what is the problem and the solution?


1.check heatar of unit.\015\0122.wireing of heater.\015\012heater not workink.\015\012thermostate also check ... Amana PTH153B50AJ Heat Pump Air Conditioner

I Have a Comfort air Heat Controller, INC Model # B-DMC24SB-1 and when there is a power outage the unit does not come back on when the power outage is over


... Comfort-Aire DMC24SB Split System Air Conditioner

I Have a Comfort air Heat Controller, INC Model # B-DMC24SB-1 and when there is a power outage the unit does not come back on when the power outage is over


... Comfort-Aire DMC24SB Split System Air Conditioner

I have an AMS9 Amana Heating and Air Conditioning unit that is not working properly. There is no flame and the igniter can't seem to start a flame when it goes through it's sequential iginition retries. The diagnostic LED light code is of a continuous/rapid flash, which the instruction manual attributes the problem to "Polarity of 115 or 24 volt power is reversed." The unit is only 2 and a half years old was working prefectly fine before this issue occurred. The only anomaly that occurre


It turns out the the igniter went bad... I replaced it and everything is working fine now. ... Amana Air Conditioners

I have a dometic heat pump a/c basement park model unit. The fan is not working. The compressor runs, but no air inside or out. I have power into the run cap. but not on the brown wire to the fan from the run cap. I also have no power to the fan high or low off of the relay board. Where do I go next to isolate?


... Dometic Air Conditioners

Hello, I recently purchased a new home which has a Nordyne model # JS58D-060KA air conditioning unit. Both times when the home was appraised and inspected, the AC worked when they provided power via a generator. Now, the standard electrical supply has been turned on and I cannot get any results. When I turn the temperature down on the thermostat I hear something kick-on in the attic above the thermostat but no air. If the thermostat temp is adjusted for heat or is disconnected, whatever is k


... Air Conditioners

My amana rcc24c2b heat and air unit blows cool air when it's on heat


... Amana Air Conditioners

I got 1 customer having conia air cor split type Model CA30001,when you turn it on,on indoor unit it shows red power LED on and on side green light blinking takes 3seconds to blink and indoor blower not working what will the problem can u help me thanks regards


... Air Conditioners

Bryant air conditioner - outside unit will not run - before it quit running, air temperature in house rose from 65 degrees to 75 degrees. Inside fan continued to blow - air smelled like a car air conditioner that ran out of Freon. Bought Freon - need to know where to add it. The heat pump model # BF-163S bi directional but also coming from unit is another line that runs same direction with same type of valves. Air conditioner model # 697CN030 - B


... Air Conditioners

I have a Inter therm Model# FEHB015HA central heat & air unit that I had problems with in the summer as the out side unit would not come on but the blower would kick on but nothing on the outside unit(No cold air).Ok I fixed that as it was the the transformer that switched it down to 24 volt to go to the outside.Now I have noticed that when the heat is on it will not kick the outside unit on?It has been very cold here in Georgia but right now as I type it is 50 degree's and the outside unit is s


Hi, if this is not a gas fired split system, it is a heat-pump with aux heat strips. The outdoor unit must be on to warm you're home by way of the reversing valve. The strips in the indoor unit are for emergency and auxiliary heat only. ... Air Conditioners

I have a Sharp portable room air conditioner model CV-P10NC. The power plug RESET button and TEST button will not click in order to check out the power plug as the unit will not turn on. They did test O.K. at first but the unit would still not come on. Can the power plug back be taken off to check out the fuse inside - or since it is a type of built in circuit breaker maybe it does not have a fuse inside ? The instruction manual states that " This air conditioner uses a fused power plug". The un


The fused9G.F.C.I.) cord you speak of is probably the G.F.C.I. built onto these units by design, can you or someone you know get access inside the unit and :Hot-Wire" the units cord and,bypass the power cord ( Just To Test the Unit)and see if it stay ... Air Conditioners

Amana PTH153B35AK This unit is less than 30 days old, heats fine cools fine, but when i have it in heat mode,set @ 70 or so, as soon as the room heats up, the unit will cycle into a/c mode and blow super cold air for about 5 minutes than return to heating. Sometimes it will reach the desired temp. and turn off like it is supposed to do, but for the most part it just cycles back and forth from hot to cold...Amana has the worse help/service i have ever seen, i was on the phone for an hour,everybod


This often happens if the unit is oversized or to close to a wall or object. ... Amana PTC153B35AK Air Conditioner

Amana #PTC153b50AJ ser 0410686783 Customer heard a pop in unit and it went off. Breaker was tripped. Reset breaker and unit runs in a/c mode but does not heat in heat mode. This is not a heat pump but electric heat strips. Unit says there is a manual reset for the heat but we have not located the reset. We turned power off to the unit to reset fault etc and still no heat. The flashing light just blinks once every 4-5 sec. Could use some help in diagnosis Thanks DK


... Amana PTC153B50AJ Electric Heat Air Conditioner

I have a Lennox model CB19-51-1P air handling unit with HP19-511-1P compressor heat pump unit. I just turned the heat on for the first time this season. And I am getting low heat volume. The heat pump unit is running for long periods. I am getting enough heat to maintain the 70 degrees setting with constant cycles, shutting off for short periods, running long periods. When the thermostat is turned to a cooler temperature, the unit shuts off as it should. Could you please help trouble shoot po


First thing you need to check is if the reversing valve is working you maybe running your A/C with the heat strips on depends on the t-stat your using some heat pumps will bring the strips on with a high d ... Air Conditioners

Lg Neo plasma inverter split model s18ahn isn't heating or cooling properly. When in heating mode air con will go into defrost/preheat mode for 5 minutes and then air con will blow out air for 5 seconds and then go back into defrost/preheat mode. When in cooling mode indoor fan will pump out air but will not get cold. In both heating and cooling modes the outdoor unit will not start up and the outdoor fan will not spin. I have just replaced the main pcb board and that hasnt made a difference. Bo


... Air Conditioners

Hi. I have a LG heat pump/air conditioner. A split system with 2 indoor units. Model LMN095HV and LMN125HV. After a power failure by our local power company, I am getting a CH 05 error code. I have turned off th power to the units and waited several minutes and turned it back on with no luck. I know the code means poor or no communication with the outside unite. And I am getting the same code on both inside units. an you help? Thanks, Peter C [email protected]


Hi, this error is a communication error between your indoor and outdoor unit, check all wiring and connections - ch 5 is a communication error between the indoor unit and the outdoor unit.\015\012You can try turning the breaker off ... LG LSC183VMA Split System Air Conditioner

I have a Comfort-Aire Model RAH-123A Room Air Conditioner and Heat Pump. When depressing the low or high heat control button, the unit hums like it wants to start but shuts off in about 3-5 seconds. My suspicion is that the compressor is trying to start but a thermal cutout shuts it down when it does not start. The unit was installed as part of a sun room addition and the remodeler is no longer in business. If I cannot solve this problem through the internet, I need a local contact fro servic


Hi!\015\012Before I give you a possible solution to your problem you need to check the heating temperature Control, set it to a warmer setting, if problem persists, check the power cord.\015\012\015\012To test your power supply cord:\015\012\0 ... Air Conditioners

Heating unit model number PCB024075-1 is blowing cold air...note this is first time this year using heat...gas is on and unit is coming on fine it's just blowing cold air


... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1785 seconds