Will not blow heat when I turn it on heat. The blower blows

\015 HEAT PUMP WILL NOT BLOW HEAT.\015

Answers :

Have you tried turning on the emergency/auxillary heat on to see if the heat strips kick on? If that works, then it sounds like your unit is low on refrigerant. If your not sure about the ER/Auxillary, there should be a switch on your tstat for this.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a weather king model 90RJ - first time I've had hot air heat..When I turn on the heat, the blower turns on right away ( blowing cold air) - I understand that the ducts have to cleared of the cold air - but shouldn't the blower turn off until the air is warmed to temp thanks Bob


When the furnace first comes on there is a induced draft motor that should come on first but that forces air up the exhaust or flue,not into supply air on ductwork. It is not unusual for cold air to be blown out when burner first turns blower motor o ... Weather King 10AJA3001AH Air Conditioner

I turn the thermostat down at night. When I get up in the morning I turn it back up. The heat kicks on for a minute or two then the unit starts blowing colder air. If I turn the thermostat to the OFF position, wait until I hear all blowers stop, then turn it back to the ON position, it will start blowing HOT air again. Some times I have to perform this cycle 3 times to get it to keep blowing hot air. Any ideas as to what is shutting the furnace off? Thanks, Wayne


Theremostat switch problem. Replace it. ... Air Conditioners

Will not blow heat when I turn it on heat. The blower blows


Have you tried turning on the emergency/auxillary heat on to see if the heat strips kick on? If that works, then it sounds like your unit is low on refrigerant. If your not sure about the ER/Auxillary, there should be a switch on your tstat for thi ... Air Conditioners

I have a GE ZONELINE 5100 hvac unit when unit is turned on the blower works but it will not generate heat when set on heat selection nor will it blow cold air on cold air selection it just blows air out like normal fan what could be the problem


Check the selector switch to make sure that the controls are transferring from heat to cool. Then if the control is working you would have to check power to the valve that changes the flow of refrigerant from heat to cool. This unit may be heat ... Air Conditioners

I HAVE A RUUD SILHOUETTE GAS FURNANCE. The pilot light keeps blowing out. When I light the pilot flame it seems to work perfectly at ignition. As the Manual instructs, I hold down the ignition switch for 30-60secs to keep the flame lit and then turn the gas switch to the on position. After watching the unit I have noted this happening - the furnance will begin the heat cycle sequence and pilot litghs all 4 burners correctly, the blower fan turns on, Heating starts. But after a short period, the


Short answer, yes. However you could have another problem. Replace the thermocouple that keeps the pilot lit. You can get a universal one at any good hardware or farm store. Make sure the new thermocouple is well into the pilot flame. If the blower ... Ruud UBHC Air Conditioner

At 30,000 miles my then 8 or 9 month old chevy 2500hd 4wd pickup truck air conditioning started blowing hot air on the driver side (the passenger side was still cold). I turned the truck off and back on and it began blowing normally for a few days and then it would do it again. A year or so later the heat on the driver side went out totally (passenger side worked properly). So now the driver side blows cold air constantly. A few months after that the blower quit working all together. Now at 185,


What year truck is this? This is actually a very very common problem on those chevy trucks. Most times it is the door blend actuator that has failed. and the default for this failure is driver side blowing hot. There are a million posts out there on ... Air Conditioners

The heat pump is not working properly. i think the problem is in the switch mechanism. when the heat is on and the thermostat is turned up it blows cold air. sometimes the compressor turns on and off. if you turn the other switch to the off position, then turn the thermostat up then turn it back to heat. it will blow hot air. if you then turn the thermostat down, wait till it turns off, then turn it back up, it will blow room temp air and sometimes the compressor will turn on.


Hi,\012The problem may be the switch, but it sounds more likely that the contactor in the outdoor unit is bad and is not making all of the time...then the compressor will not always run...\012To figure it out you will need to catch it at ... Air Conditioners

I have a RUUD gas pack unit.....when you turn on the heat, the blower does not blow any air out of the vents while on "auto". If you put it on "on" it blows cold air out of the vents. What is wrong?


Sounds like the thermostat is hooked up wrong. If the ac doesnt work right its in the thermostat programming or the wiring. Hope this helps good luck ... Ruud UAMB Air Conditioner

3 amp fuse blows on ruud silohette II. With A/C off blower runs on manual OK With Heat on, gas heater runs OK, blower OK on Auto Disconnected relay wires at condenser and turned A/C on. Ran for a minute and fuse blew.


This sounds like an issue with the control wiring, there could be wires shorted togeher either at the thermostat, or in the wall, you need to isolate the wires at both ends then check for continuity with an ohmmeter there should be none) to verify wh ... Air Conditioners

I have a payne 04 3 ton heat pump it flips the breaker when you turn it on but does not blow the inline fuse.the blower motor and electric heat strip comes on and works .troubleshoot


Grounded or shorted compressor. remove power. remove compressor leads and tape off . does breaker stop tripping? if it stays set on, then compressor is gounded or shorted. if it still trips then wiring or condensor fan is shorted or grounded, remove ... Air Conditioners

I have an old RUUD central AC unit that started blowing hot air. I set the thermostat to off and set the temp gage higher than air temp to turn the unit off and save money, but inside blower unit runs constantly. I'm trying to save money to have it serviced, but noticed my electric bill was higher that last month when the ac was working. The bill was about 4 times higher than the winter when ac is off and the gas heat kicks in. Can the blower running constantly cause this power usage and what is


HelloOkay did you check your thermostat to see if you have the fan switch on auto? The switch must be on auto or the fan will continue to run. If the thermostat fan switch is on auto then there is a malfunction in the thermostat probably ... Air Conditioners

I have two Friedrich PDE15KSB-C units. When trying to turn on the heat neither will kick into the heat mode. They both blow cold air only. When they are first turned on the air blows, and there is a click sound as though the unit is trying to start the heat pump, but then nothing really happens...just the fan continues to blow cold air. Any help would be appreciated. BTW the dip sticks are all in the positions of 1234 ON, 5678 OFF - factory setting. I did try to turn 7 on for the emergency


Keep +10 degree from your room temp and also thermostat in "heat" . And then check. But in your case, I think RV not energized. If no proper voltage in RV in heat mode, check the wiring to RV. If voltage in means RV not working properly. You have to ... Friedrich PDE15K3SB Portable Air Conditioner

I have a Carrier Gas Furnace Model # 395CAV024055ABJA, I works fine if you keep the temp low, like 68, so that it doesnt come on very often, but if you try turning it up and it needs to run for awhile, it wil start this cycle where the flame will kick on and off, the blower is continously running and only blowing cold air, I have tried new batteries in the thermostat on the wall, and have tried putting it on manual heat, no change, another thing is that once it starts this cycle, if you shut it


It sounds like it is going into overheat mode. Check the overheat sensor, make sure the flue is clean, make sure any filters are clean, also check the gas passage inthe heat exchanger, if there is a blockage from soot the system will overheat ... Carrier Air Conditioners

Ok so I have know replaced the control board air handler board today the unit also has a new transformer and a new blower motor and the heating elements test good not burned at all and it still continues to burn the 5amp fuse out worked for about 30mins now blows fuse out as soon as new one is inserted and breaker turned on....I'm lost and have no other ideas with all new parts this should not be happening, Can anyone Help!!!!!


... Carrier Bryant Control Board Air Handler HK61EA006

My blower on my heat pump will not cut off; It is set to automatic and this morning I turned the setting up to 90 and it is still blowing


Check the thermostat first. <ake sure it is not set for FAN ON vs AUTO mode. If it is OK,Replace the fan relay. It is stuck in the ON mode. ... Ruud UBHC Air Conditioner

I have a goodman gsh130361 3 ton heat & air. It was installed 05/05/2008. all seemed well until cold weather, in 2009. The fan turns on and start blowing before the heat box is even warm. The heat set on 70----- when it gets 68 or 69 {in the house} the out side pump kicks in, 10 to 20 seconds later the fan turns on and blows freezing air into the house. the temperture will drop dramatically for the next 1 & 1/2 minute. The box will heat up and then all is well untill the next cycle.


The PCB unit that controls the thermostat and Coolant is malfunctioning... check that particular unit...that would help.... ... Goodman Air Conditioners

The blower is on but the heat is not coming out. After leaving as is it start coming out then after the house is warm and U decide to turn it down again blower is on but heat is not coming out. Sometimes it can take up to 8hrs before the heat starts coming out. The heat is perfectly fine when it starts coming out. Another thing is when we adjust the heat it the blower is on but the heat is not coming out holding the temperature at 77 degrees seems to be the sweet spot. Thermostat appears to be o


Jump out t-stat is first test ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

Carrier Heat Pump Model 38EYG042300 airhandler blower operational, T-stat set to emergency heat still operational and does not blow the 5 amp fuse . When T-stat is set to Cooling or Heat from the Heat pump after about 3-5 minutes the 5 amp fuse continually blows, checked the transformer both primary and secondary checks out good, check transformer to ground not grounded, is it posibble for the T-stat to ground out and blow the 5 amp fuse when calling for the heat pump to heat or cool? Hard for m


Hello,\015\012Compressor contactor coil or reversing valve coil... they may not have a direct short but still may pull high amps and blow the fuse... have you had a brown out or power outage lately? They will fry coils...\015\012From what ... Air Conditioners

I have an electric furnace and heat pump that will at times blow only cold air during the heating season. I have checked the filter and don't believe that to be a problem. I usually have the temperature set to 74 degrees. When the outdoor temp. is extremely cold the axillary heat indicator will be on and still no heat. I can turn the heat pump off by switching to emergency heat and will get some heat from that but not as warm as I think it should be and even that will at times only blow cool


You are losing operation to your heat strips.\015\012\015\012In heat pumps, there is a secondary heat source. Usually electric heat strips. (Sometimes a gas furnace, this is known as a "dual fuel" system)\015\012\015\012The he ... Carrier Air Conditioners

Goodman outdoor AC/Heating unit, model #: GPG10420901A will not turn on heat. If I place the fan mode to "ON" it will blow the cold air, and the Air Conditioning works fine. When placed on "Auto" the blowe will not turn on and no heat is produced.


... Air Conditioners

No heat I have an Amana heating and a/c unit model # pth153b50ae. It was blowing heat all winter then just stopped. It now blows cold air and is either bringing in cold air from outside or is blowing a/c. It does not change no matter where the control knobs are set. I checked the fuse and actually changed it but no difference. The only way I can turn it off is either unplug it or take the cover off and switch of the little micro switch. I'm thinking the board is gone. Any help would be appreciat


Check to see if unit has a contactor,they arc and weld together,keeping your unit on ... Amana PTH153B50AE Air Conditioner

Not as much heat coming into house as was before,went to heater unit which has 2 60amp breakers on unit and while running turned off top breaker and came back upstairs but did not feel any difference in heat temp, went back to unit and turned off bottom breaker which turned of all heat plus blower motor. what is my problem?. thank you


First what type of heat do you have and if you can find the model # it would be helpful. Also if you have filters check them. ... Air Conditioners

I'm having a problem with my heating and air system, my heat only works on emergency heat ( and run 24/7) if i turn it to regular heat it only blows cold air. i dont think my outside unit fan is turning( i could be wrong about this one) how can i fix this problem so i dont have to run my emergency heat all the time


If your Heatpump's fan isn't running but your compressor is, your fan motor is out. If nothings happening at all ensure your getting power to heatpump (ex: breaker tripped, fuses blown on outside power switch, or fuses blown in breaker box?) ... Air Conditioners

Heat pump just a response to our question , no the fans on the outside are not working.(i only had heat if i turn my therostat onto emergency heat,when i turn it to heat it blows cold air. what can i do to fix this problem. thanks for your help


... Air Conditioners

No heat My 7500 zoneline will not provide heat consistantly. I can unpplug the main power source to the control boards and plug it back in, ,and I will then get heat. If I turn down the thermostat (80 to 70), then turn it back up, I do not get heat again, only cool blower air. Is one of my control boards bad? Thanks.


It sounds like it could be the tstat itself. Unless you use a voltage meter to take some readings it's hard to determine if it is a board. The best thing for you to do is remove the tstat from the system and manually operate it with a jumper wire t ... GE Air Conditioners