Raypak pool heater, error HL2

\015 Heater wont fire, it calls for heat but no spark! ARRRRH! So frustrating.\015

Answers :

It is probably the pressure switch. Remove the hose from the inducer and **** in and then blow lightly several times. It is probably stuck in the either the open or closed position. If this isn't the problem, check your manual reset limit switchs to make sure they haven't tripped. Also, make sure your are getting power to the ignighter as well.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Raypak pool heater, error HL2


It is probably the pressure switch. Remove the hose from the inducer and **** in and then blow lightly several times. It is probably stuck in the either the open or closed position. If this isn't the problem, check your manual reset limit switchs ... Ruud Central System Air Conditioner

I have a Raypak 2100 pool heater. I fired it up this year and it ran for days until it quit giving me a PLT error. The symptoms are that when I turn it on I do not hear the typical electronic spark sound but I can smell the gas. After about 30 seconds I can hear some sounds coming from the PC board area. I don't know if it is related or not but last year the LCD started to act up where some of the characters were not legible and when adjusting the temperature the number displayed would ski


Hi, i think you are experiencing a control board problem, because from the detailed explanation you have made above, it's obvious that you need a new board besides i don't think you can wire it yourself because of the complicity of the board.. ... Air Conditioners

Raypak 406A pool heater pilot will not light. Readout goes to SPK and freezes at that point. No error codes are stored.


Hi,\015\012This is fairly simple.... if you have no spark, then check for power to the ignition control module...if you have power then the module is bad... no power... then figure out why it is not getting power.\015\012\015\012My ... Air Conditioners

I have a Raypak RP 2100 R405 pool heater. When I turn the rocker switch on the front panel to ?on? I get nothing or no lights on the front control panel and nothing happens to the heater. I checked and there is power going from the transformer via the blue wire to the PC board but no power being distributed to anywhere else. Is it the PC board and if so how can I check to verify this is problem? The board is expensive and no one will accept a return of this item it if this isn't the problem. C


\012When you turn the power ON of the unit.It will show "Water pump" in the display".\012If its not showing "water pump"\012Then  3 things has to be checked>\0121)Check ON/OFF switch right side of heater.\0122)Check 120/240 volts for tr ... Air Conditioners

Raypak versa II pilot light on heater does not go on. Choice of heating range for pool and one for spa. Last year the pool dial stopped working. This year none is working.


... Air Conditioners

I have a Rheem Raypak Pool heater, model P-m266A-EN- C that won't heat. When I turned it on it seemed to be working then about an hour later it had a "service" blinking and a ROL code on the display. When I turn it off a CFH comes on and then the ROL. Any Help?


... Air Conditioners

I have a Raypak pool heater with a invensys gas valve, the burner is not kicking in, pilot light is lit and stays lit, I jumper the complete switch circuit and still does not kick in. this is a millivolt system, do I have power? is the gas valve repairable? thanks Mike


Usually not the gas valve unless line voltage was applied to it. Millivolt systems are very touchy about connections. First check the output of the millivolt generator (thermopile) the wires for this usually go straight to the gas valve they shoul ... Air Conditioners

Raypak pool/ spa heater Low NOx Model 407A: Will take long time to fire, stays in spark mode, and then when iit does fire, it shuts off and takes long time to fire again. If you can get it going it stays on until desired temperature is reached. Repair company gave up on fixing it after multiple trips and stated that the burners were dirty and needed to be cleaned. Have pulled out burner tray and cleaned everything off with wire brush. Put back together and have same problem. Interesting note it


The pilot is not proving to the control.Check that there is a GROUND/EARTH stake to the pool heater in the dirt.The pilot assembly needs a ground wire too the control. ... Air Conditioners

We have a Gulf Breeze pool heater powered by Scroll compressor. When our pool guy opened the pool, the heater didn't come on. It says it's in Standby mode. Our pool guy won't touch it and we're having trouble getting anyone to come out and fix this. Help!


... Air Conditioners

I have a Sta Rite Max E Therm pool heater and when I start the unit, the fan kicks on but the heater never does. After 45 seconds or so, I get a " Service Heater" light. The circuit board had leds for limit switch, pressure switch, air sensors, etc, but none are lit. The ignition contol module has a blinking red led which the manual says is a "ignition lockout" issue. What is an ignition lockout? Do I need to replace the HSI Ignitor? Or could it be something other than ignitor? Thanks


Hi,How many times that light is blinking?Is it 3 times sequence?Let me know,so that we could proceed.Thanks!! ... Air Conditioners

Osaka Gas Blower Heater Model: 43-553 The heater takes a very long ignition and then gives error 11 or 12 .. Another heater is functioning ok on the same line so there is no problem of gas pressure .


It sounds like a gas line or gas jet is clogged. Clean off the gas tip that is near the electronic igniter. Also find a small diameter wire to clear any obstruction in that jet. Also, carefully clean off the igniter tips. ... Air Conditioners

Rattling sound on my pool heater. When the filter runs without the heater, there is no sound. But when the heater is on, a loud rattle starts, like a rock in a washing machine.


... Air Conditioners

Have Jandy Laars LT Low NOx Model LX250-L Natural Gas pool and spa heater #LT400N-L - it won't start - the power going to the heater is fine - but the heater is dead and has no power


... Air Conditioners

New hayward pool pump, wired black wire to L1 and white wire to L2, pump does not pump. If I run a garden hose into the pump, it then send water to the pool heater. When reconnected to the pool,it still does not pump.


Check your wiring for correct rotacion of your pump motor ... Air Conditioners

Hi I have a Rinnai 100f Space Heater. Found it with a blinking red light.. Whe I shut it off to restart it. It restart by hearing the combumsion fan start up then go off with error code 53. Manual says this is a sparker error. What parts are involved in replacing to fix this error? Thanks Lou


... Air Conditioners

I just purchased a pelonis digital fan forced heater model number hf-0063 and took it out of the box. i plugged it in and it immediately began loudly beeping and had an error message "E2" blink on the display. i cannot turn the machine on as the error message blinks non-stop. there is nothing in the owners manual regarding the error messgae E2. how can i fix this issue?


... Air Conditioners

The heater comes on and works fine for awhile-come back later and I have an error code of Eo1 and service heater lights is on and the heater is off!!


Check indoor room temp sensor & replace it. ... Air Conditioners

I have a triton minimax plus 400 pool and spa heater that is not working. there is no clicking sound when I turn on the heater. The valves all adjust, the power light comes on and a sevice light is on but no click or heater coming on. Any ideas?


... Air Conditioners

Sta-rite sr200na pool and spa heater. Ignition lock-out code on Fenwal. Replaced ignitor; same result. Replaced Fenwal & upper circuit board; same result. Heater starts to run it's cycle. Valve clicks "open" after about 7-10 seconds of blower clearing heater. Can smell slight gas smell then goes into lock-out.


... Air Conditioners

My comfort heater ES-1500 is showing an error message "01" and will not run. there is nothing in the manual regarding this error message. Can you help?


... New Comfort ES1500 Energy Efficient Infrared Heater

We have a Teledyne Laars Series 2 pool heater. Wh...


I know all too well what the issue is. Sometimes it self corrects and sometimes not - then you take apart the top side of your heater and pull the manifold/tubes. There are rubber gaskets that probably dried out over the winter. You can try to jus ... Air Conditioners

Hayward Pool Heater


... Air Conditioners

How many btu is raypak gemini model 331 have, is it 331,000. the label is gone off the heater and i can barely read the label and it need replacement. want to get same size heater thanks


... Air Conditioners

I have an older Teledyne Laars EPS Gold Series One pool heater. About a year ago, I had a new Jandy igniter installed. Now, the pilot light goes on and simply burns -- it does not ignite the full burners and I smell gas (not a good sign). Pool does not heat. I have 10PSI of water pressure from my filter going into the heating pipes so I think I am good from that standpoint. Any help would be appreciated.


You need to see what what pressure is required to turn the heater on. If you don't have enough flow or pressue, the heater will not ignite. Was it working before? ... Air Conditioners

I have a hayward modelh100idi above ground pool heater we can't get it to stay running it fires up but go the flame goes right back out (propane heater)


You need a flame sensor,its located where you see the flame touches,lightly sand with fine sand paper,if it still doesn work you have you replace it.if this helps please give me a fix ya vote ... Air Conditioners