Having problems with your Air Conditioners ?

What is the cooling btu on my BDP company division of carrier

\015 What is the cooling btu on my BDP company\302\240\015\012division of carrier corp model # 585CJ030050? \015\012It pulls 14.8 amps at 220volts. The HP is 1/2.\015\012Also what is RLA 13.9 & LRA 72 and would you\015\012know what\302\240the seer rating is?\015\012\015\012Any info is appreciated.\015

Answers :

Is this unit real old ? it does not come up in my book . the btu is 30000 that is the same as 2.5 ton it may be 6,7 or 8 seer i dont think its a 10 seer because the 10 seer units are listed and yours is not . if this sounds wrong please look up the mod # again and post the ser # too ......... Please if this answer helped , please rate this 3 or 4 stars . and keep me in the paid answer department . A 1 or 2 may knock me down into the unpaid ranks. Thanks Cactus Bob .

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

What is the cooling btu on my BDP company division of carrier


Is this unit real old ? it does not come up in my book . the btu is 30000 that is the same as 2.5 ton it may be 6,7 or 8 seer i dont think its a 10 seer because the 10 seer units are listed and yours is not . if this sounds wrong please look up th ... Amana Comfort Zone 12M32PBEH Air Conditioner

WHAT IS THE COOLING btu of BDP CO. DIVISION OF CARRIER model #38ED060300, S.N. #T407051


... Amana Comfort Zone 12M32PBEH Air Conditioner

What is the seer rating on my bdp company division of carrier air conditioner model #397haw036080 serial # 2884c96839?


... Amana Comfort Zone 12M32PBEH Air Conditioner

Leaking aircon I have a carrier air con which is leaking into the room. It is 13+ years old. It has a 10 amp line but adequately cools a 31 square metre room. I am happy to replace it but do not know what btu it is. How can I find out.


THERE IS A TUBE OR CHANEL FROM THE FRONT EVAPORATOR DRAIN PAN THAT RUNS TO THE BACK OF THE UNIT INTO THE CONDENSER PAN. IT IS ALWAYS ADVISABLE TO THOUROUGH LY CLEAN ALL COILS, AND DRAIN PANS AND DRAIN LINES ANUALLY. IF THAT TUBE OR CHANEL WAY GETS PL ... Air Conditioners

Friedrich KS15L10 (14,500 BTU's) not efficient as 9,900 Carrier!


... Friedrich QuietMaster KS15L10 Thru-Wall/Window Air Conditioner

John. [email protected] I have 2 carrier units both installed in 2006 and still under warranty, they are a 38brc030 and 38brc042 the evaporator coil in both units have to be replaced and the compressor coil in 38brc030. The repair company says the evaporator coils have had alot of problems and Carrier has modified the size of them. The repair company says the parts will be covered by Carrier but the $2690 flat rate cost of labor to replace them is not. One is seems like a high cost for the labor a


Hi,\012The best thing to do is to call Carriers customer service line or their tech. support number... often times the customer talking to the co. directly will get better results then the dealer talking to them...\012The dealer does need ... Carrier 38BRC036 Air Conditioner

Have 9 yr old Carrier model 3BTRA-048 12 Seer AC. IT has stopped cooling / Called Co that installed it/ TEch came out and checked outside compressor, it was ok/checked inside coil it was freezing 1/2


I wouldn't be so fast to say that it isn't low on R22. What are the indoor and outdoor temps? If there was a restriction I would expect the high pressure to be higher. I would definitely get a second opinion. Some companies will give free second opin ... Carrier Air Conditioners

Heating and cooling window units with 18,000 BTU cooling and 15,000 BTU Heating


... Whirlpool Air Conditioners

8,000 btu commercial cool red light - Haier 8,000-BTU Commercial Cool Portable Air Conditioner CPB08XCL-LW


... Haier 8,000-BTU Commercial Cool Portable Air Conditioner CPB08XCL-LW

Carrier 38YXA036320 My Carrier Model 38YXA036320 Heat Pump will not run. Fan and compressor will not start in heat or cool modes. When I select cool, I can stand next to the unit and I hear things being energized but nothing happens except a humming sound.


... Air Conditioners

Carrier Comfort 13 Puron model 24ACA3 / FV4NB006 installed 3/18/08 no longer cooling. Carrier AC1-100 Thermostat checked per manual - all default settings intact. Test override did not turn unit on though. All systems turned "on" - circuit breaker "on". Noticed last night that room temperature was rising so we turned target temperature down. Usually room temperature and target temperature are within a 1 or 2 degree swing. System did come on & cool once last night. Today though system is not comi


Verify 24 volts at the low voltage transformer inside the air handler.\015\012If it is OK, jump out the red/green and yellow thermostat wires. If everything comes on, replace the thermostat. ... Carrier 38CKC036 Air Conditioner

Carrier thermostat Hello, My Carrier electronic thermostat is connected to a heat pump.  It was set to the COOL position during a summer thunderstorm when the AC suddenly began running no matter what the SET temperature was.  It works normally when I change it to the AUTO position.  The HEAT and EHEAT positions work normally. I tried cutting power to the unit for 2 days, after which it worked normally even on COOL, but after a short power failure it resumed the problem of running the AC continuo


I hate to say it but Ive had trouble with Carrier's Tstats doing similar improper things. Unfortunatly the only repair is going to be replacement of the whole tstat. I recommend Honeywell's FocusPRO or VisionPRO tstat. Ive yet to have one fail and th ... Air Conditioners

THe a/c has very weak flow of air blowing even with the fan on high. My last carrier had a high volume of air coming out of the vents which was adjusted by the installer as I desire room by room. This installer said the latest carrier units are designed differently and dont allow for adjustments. It takes hours for the house to cool down a few degrees and runs continuously. It only will cool below 74 degrees when the temperature outside is under 77. I have had several installers to look at


Hi,\012It sounds like you got shafted and the guy installed a smaller air handler unit with a smaller motor to try to make more of a profit...\012The problem is getting an unbiased opinion from someone who knows their stuff...sad to say b ... Carrier Air Conditioners

I don't know which Carrier A/C model I have at this rental home and there is no manual on this unit. But the box attached on the wall upstairs has the ProgramOn Heat set at 62 and Cool set at 85. What is this ProgramOn mode and how from this ProgramOn mode that I can set to cool 75 and not 85. I can lower it to 75 but once I leave that mode it would return to cool 85 again. But i always have it on just Cool mode at 75 but i don't know why the house most often get hotter at night. Do you know w


Hello NTRINHVU You have to hit the HOLD button to keep 75 permantaly,otherwise it will go back to 85 every 3 hrs automatically. ... Carrier 38CKC036 Air Conditioner

I have a question about matching up BTUs for the inside and outside units as I have had conflicting info from 2 different repair men. We have a 36 BTU condenser outside (Mitsubishi Mr. Slim) and a 24 BTU unit in the main living area with two 9 BTU units in each of the 2 BR for a total of 42 BTU on the inside. The installer of course says this is perfectly fine, another repair company said this was the reason why we were having so many problems with the unit. When it works, it's great. However i


Hello,In a traditional air conditioner setup where the compressor runs at one speed, the condenser and evaporator need to have matching BTU ratings. If the condenser (compressor) is too small, it will not be able to cool effectibely, and ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

Hi,I am really hoping to find someone to help me if possible. I have a one year old carrier infinity 4ton 17seer condenser and a 5ton variable speed air handler. I has worked fine but now i am getting a SYSTEM MALFUNCTION on the thermistat. When this message appears the air handler continues to blow and only the fan on the condenser continues to run but NOT the compressor so it is not cooling. At times it begins cooling again but then later stops cooling and shows the same malfunstion message. I


Hi,\015\012If this si what I am thinking it is, it will be very hard to find and prove.... \015\012The compressor windings have aflat spot and if the motor stops at the right place it will not atart. The voltage goes way up and kicks out ... Air Conditioners

My Carrier AC does not cool down. We just turned it on today. We turned the hermostat to "cool", the fan worked, the outside split-system was running. But there is no cool air came out. Please help! Thank you!


Usually that is an indication that the freon has leaked out. If fairly warm air is not coming out of the outside unit..it time to refill and check for leaks. ... Air Conditioners

Hi My Danby 6000 BTU window air condition is not cooling. I set thermostat to maximum cooler level as 8 but still not cooling room. I clean all the dust with wire brush. Fan is working fine and I can feel lots of air comming through the air condition but no cool air.


... Danby DAC6003D Air Conditioner

I have a Comfort Aire PE121A that will not cool or heat. It is about 3 yrs old, and it just barely cooled when I got it. It is a 12000 btu unit, but I have a window mounted 6000btu unit that will run cooling circles around teh PE121A. What is wrong with the unit, and is there a repair service in or near Eugene Or that can look at it. It acts like there is no coolant in it; poddibly has a leak???? What can you tell me? My e-mail is [email protected] Thanks in advance for your assistance.


... Comfort-Aire PAC-121 Air Conditioner

We had a new Carrier Weathermaker Infinity Gas Furnace installed in our home on 9-21-99.The Carrier people said the furnace was in good condition this past October.But prior to that as of April 2010 the furnace started sending up really cool air. Was told by the Carrier serviceman that the Controlboard was running on high and low at the same time also found the Board fired.Then NO HEAT. Got a new Controlboard installed,that didn't work Still NO HEAT.Was told furnace needs a model Plug that was


... Air Conditioners

Amana PTC123E35A 11,500 BTU Cooling 1 Ton, 12,000 BTU Heating 1 Ton will not cut off in heating mode


... Amana PTC123E35A 11,500 BTU Cooling 1 Ton, 12,000 BTU Heating 1 Ton

Whirlpool window air conditioner 20000 btu's not cooling properly


It is possible the cover needs removed and the condenser coils are in need of a good cleaning. (the one in the back that is outside).This assuming the compressor is running and it has not developed a leak and lost the coolant charge. Eric ... Whirlpool ACQ158XP Wall/Window Air Conditioner

Hi everybody i want some help , iam a technision in air conditions ,i was fix a central ac carrier and i found that everything works good the compressor and the high pressure fan and indoor fan ,but the problem was there is no cooling and the low pressure pipes werent cool and no drop of water on it , what i do ??????????


If the compressor is running - the suction pressure should be 65-75 psi - if it is very low - not enough freon - if it is very high - the compressor valves could be damaged - both will cause this ... Air Conditioners

My nordyne AC unit thats 2 years old suddenly froze up and after thawing, the compresor runns but the thing only blows warm air. COndensor fan is spinning but the air is cool, not hot like it used to be. Filters are clean and are ALWAYS changed. The inside of the unit is spotless, it looks like its never been used. Its always cooled my home down in 3 minutes as its a 55500 BTU unit.


You have developed a freon leak or the compressor valves have gone and it is not pumping. ... Air Conditioners

My carrier air conditioning unit does not cool below 72 degrees. I was continually running to the point the outside unit connection to the house was frosted. I turned the unit off and let sit for a few hours. Turned it back on and the Thermostat seems to be working; however the unit can not cool the house below 72 when it had in the past. Am I looking at a leak or re-charge???


The unit has lost part of it's charge, and will need recharged. For that reason a leak must be found and repaired or it all will reoccur again. ... Carrier 38CKC030 Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific