Can I mount a Samsung AC unit thru wall rather then window?

\015 Can you mount a 6200 btu samsung 9,7er thru a 2X4 wall without a danger of it freezing up? A couple of the side vents will be covered up by the wall.\015

Answers :

As long as the vents are completlyeyt covered. and cove rit in winter

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Can I mount a Samsung AC unit thru wall rather then window?


As long as the vents are completlyeyt covered. and cove rit in winter ... Frigidaire FAC107P1A Wall/Window Air Conditioner

Just had a Fujitisu 15 rls installed.It makes so much noise when starting up that it wakes me up & I'm hard of hearing. The outside unit is mounted under a window. When the whining noises start you can open the window and listen to the outsde unit and it is quiet. Seems the noise is come thru the wall. Could the noise be coming from the lines? After the whining stops then there is a growl type noise that continues.


Sounds like the noise is in the pipework,whether it is kinked or very hard against building? ... Fujitsu 24C1 Air Conditioner

I have a thru-wall unit that is draining out of the back and cooling just fine. My problem is the hole in which the ac goes thru. There seems to be some condensation on the bottom of the unit that drips down onto the board below(would be the window sill if I had taken it thru the window). I have thought about taking the unit out and placing a piece of insulating foam in the bottom of the unit or closing the 1/2 inch gap between the bottom of the unit and the board with insulation or expand-a-


You are correct the gap needs to be closed, i would suggest the double taped insulation they use on pick up truck when you put a topper on, as if you ever need to remove unit it would be easier then the expansion foam. Hope this helps Tim ... LG Electronic Window Air Conditioner

I want to wire digital wall mount thermostat to my window AC unit


I think you are wright and also may lead to short cycle and burn the start relay on compressor(it may be too hot to be without air just now)try bigger relay when it is a bit cooler and 24,000btu must220-240 volts be very careful ... Air Conditioners

I want to mount a window ac unit in a wall sleeve. Possible???


... Frigidaire FAC124 wall/Window Air Conditioner

The air conditioner is emitting cool air instead of cold air. I have the setting on cold and the temperature setting at 60 degrees. On these days that have been near and over 100 degrees, that cool air offers no relief. When we first got the unit, it emitted cold air. We've changed nothing. The unit is not installed in a window but rather in a hole made for it in the wall.


... LG LWHD1009R Air Conditioner

American standard thru-wall heater air conditioner (PTEC1501GAA) will not heat. When wall mounted thermostat is turned up for heat, the fan turns on but no heat comes out. I opened it up and checked the fuse which was okay. I suspect the unit is of mid-1960s vintage. I tried to locate a manual on the American Standard website but it was no help and mostly focuses on plumbing products. Ron


Sounds as if the heater coil itself is burnt out. These coils may be repaired if you can get an universial coil repair kit and rewire the heater coil yourself. Since the age of the unit is in question I don't know if it is possible to get a kit fo ... Carrier 52PQ307 Wall/Window Air Conditioner

Can this a/c unit be mounted sideways? - Haier HWS18VCA Thru-Wall/Window Air Conditioner


No. A/Cs must remain upright in their design position for the compressor to remain lubricated and for the condensate water to drain properly. ... Haier HWS18VCA Thru-Wall/Window Air Conditioner

Crosley window ac unit frezzes up - Crosley CA18WYR Thru-Wall/Window Air Conditioner


... Crosley CA18WYR Thru-Wall/Window Air Conditioner

Water leaking in floor from window unit - GE AJES12DCC Thru-Wall/Window Air Conditioner


It needs to be slightly angled down towards outside for condensate to run off out side. ... GE AJES12DCC Thru-Wall/Window Air Conditioner

Window or wall mount


The differance between a window and wall mounted A/C is the mounting system.\015\012Window units are usually smaller BTU systems they set in the window, so you do not have to cut a hole in the wall to install it.\015\012For a bedroom say ... Frigidaire FAC124 wall/Window Air Conditioner

I have a Daikin 4mxs32 with 4 indoor 9K wall mount units. About 3 months old. All of a sudden it stopped heating or cooling in all rooms. It works in the closest room to outdoor unit. Not at all in furthest room but does work somewhat on unit directly on other side of the wall and also somewhat on unit directly on other side of wall behind closest unit. Then I also noticed that when I turn the furthest unit that somewhat works off the close unit that somewhat works goes up in discharge temp in A


... Cfm Daikin R410a Split System Air Conditioner

Hampton Bay HBD250 model. Is it a wall unit or a window unit? Mine is installed in a cinder block wall and will not be warrantied if it is a window unit.


... Hampton Bay HBLG5004 Air Conditioner

Cs-ye12mke. Panasonic Inverter A/C system How do i access the drainage tubes behind or within the wall unit. The unit appears to be sealed with little access to the internal parts. It leaks down the wall after a short period of usage. I can access the outside unit and have tried to vacuum the drainage house from downstairs, but believe it might be plugged by the upstairs unit, or a leak in the tube itself. How is this unit mounted to the wall?


... Panasonic Air Conditioners

E6 error I have a new Friedrich split A/C unit (ten days old). Just ran it for the first time and after a couple of minutes, E6 shows up on the display panel on the wall mounted unit. After some detecting, I discovered that the unit outside never comes on. The wall unit does blow but it seems to just be blowing air (yes, I have the remote set to "snowflake"...but the "snowflake" light on the display panel also turns off after the initial couple of minutes. I HOPE the problem is not in the wall (


... Air Conditioners

I have a Mitsubishi MS-09D wall mounted air conditioner. The cooling function does not seem to be cooling. The fan is running but the it seems to be recirculating the air only. The defrost light is red on the wall unit. I don't recall this light ever being on before. Could a button or combination of buttons on the remote unit have been bumped somehow? Could you please tell me how to reset the remote control or wall unit to have the cooling operation to come on again? The air ducts are clean,


... Mitsubishi Air Conditioners

Can I mount a window unit with no outside access


You could/can, but don't forget that (a) there is a good chance of heavy condesation, so size pan appropriately, or drain...and (b) The enclosed space where the drip pan is, is going to get quite warm. Hope this helps ... Frigidaire FAC124 wall/Window Air Conditioner

I have just purchased and installed a Samsung AQ12FEN. A qualified Airconditioner company installed the unit. The slpit unit installation is a back to back configuration It replaced a 8 year old split airconditioner that was removed.I purchased Samsung as it seems they use good technology and the unit is quiet according to the technical brochure. When it was installed and put on, the compressor noise was heard through the wall and was louder than the fan noise from the inside unit. It makes an


This could be caused by an installation problem. The system could be severly overcharged, causing the compressor to load up and can cause a failure. i would start there. Is your intaller qualified to install these systems? (does he know what he is do ... Samsung Air Conditioners

I HAVE DAIKIN VRV III R 410A, FROM 1 0F THE 5 INDOOR UNITS( THE ONLY ONE THAT IS IN THE UPPER FLOOR OF A MAISONET HOUSE) COLD AIR 24 T EVERY 5-8 MIN YOU CAN HEAR A SOUND FOR JUST 20 SEC LIKE THE SOUND THAT IS MAKING A TRAIN WHEN IS STOPPING ....SOUOU . THE ONLY TECNICAL DIFFERENCE BETWEEN THIS UNIT COMPERATIV WITH THE OTHERS UNITS IS THAT IN THIS UNIT THEREA ARE ONLY THE IMPORT WINDOW (BRINGING THE AIR ) THE OTHER WINDOW /OPENING IS OUTSIDE THE WALL FOR THE ECONOMY OF SPACE BEST REGARDS D


... Air Conditioners

Thru the wall AC units(small)


If it's the terminology you're unsure of, then the answer is yes the unit can be mounted through a wall or through a window. But you would have to have a suitable opening through the wall to mount it in. I'm not sure why it won't work in your windo ... Haier hwr10xc6 Air Conditioner

Hi there, I have two Fujitsu DC Inverter split units to heat my flat (england). The temperatures have dropped significantly -2 and below. This causes the outlet pipes to freeze up and when the units are on defrost the excess water gushes out of all other joints in the units. This causes two problems - the units are wall mounted one on top of the other, so the top unit freezes the bottom unit. The second problem is the bottom unit 'dumps' in on the floor of the area which when defrosted s


Normal cool temp 23 to 25 and heat mode 29 to 31. And regrading defrosting your pipelines no need any tray. You can insulate with Armaflex tube which is mostly used for best insulation. Hope there won't be further water leak. ... Air Conditioners

I need to remove the cover from a WMC18-1A unit. The unit is wall mounted and plumbed through a cement block wall. How do I get the cover off to clean it?


... Goodman Air Conditioners

Window unit will not turn on/work. Restart button keeps popping out when plugged back into wall. No lights will function.. the usually thermostate lights etc. when plugging into wall sounds like it wants to start but just for like one second then nothing. What could this be? (Whirlpool ac unit ACQ189XS0) ANY HELP APPRECIATED! THANKS AHEAD OF TIME.


Something is shorted or earthed, must call techncian ... Air Conditioners

My mother has an old 'no longer working' reverse cycle unit mounted in her lounge room wall. How does she get it removed, the wall repaired and finally, replace with a 'new' unit....probably split system....... She is a pensioner and does not have the money/ability to organise lots of different tradesmen to achieve this.....so is there anyone who does the 'complete package???????HELP


HelloA general contractor would be able to do this.He would be responsible for wall repair and getting a hvac person to install a new split system.Get a couple quotes estimates. ... Air Conditioners

I have a Haier Commercial Cool air conditioner, model CPRD12XC7, 12,000 BTU that has 2 hoses off the back and is made to be vented thru a window. I want to install it in a closet with no windows. Can I vent both hoses thru the wall and are both hoses exhaust or is one intake and one exhaust?? Please advise. Thanks Mark Bushman


Mark, the two hoses serve different functions (Fresh Air Intake & Hot Air Exhaust). Therefore, they would have to remain separate. Also, Haier does not recommend extending the length of the hoses, to accommodate a specific change in installation. And ... Haier Air Conditioners