Whirlpool portable AC, compressor works, but no exhaust fan

\015 Portable air conditioner, the compressor cools, but there is no exhaust air out the back of the unit, so the compressor ultimately shuts down.\015\012Is it something I can fix myself?\015

Answers :

This is a single speed permanent split capacitor motor for the condenser. One of the capacitor wires shows infinite resistance to hot and netral. The motor needs to be replaced.
There are 3 possiblities 
\015\012\015\012
    \015\012
  1. something obstructing the lower fan motor (or exhaust motor)
  2. \015\012
  3. bad fan capacitor
  4. \015\012
  5. or bad motor
to check any of these you will need to disassemble the unit to get to the blower. there are several screws located at various points on the plastic housing covering the unit. Once removed you should be able to check for motor obstructions visually. for checking the motor and capacitor you will need a volt/ohm meter and ideally a capacitor checker. you could try to spin start the motor while it is powered up this could be a possible sign of a bad capacitor if it will start when you do this or if the motor will spin freely while powered down and will not spin start when powered up. I know that is kind of confusing but its how they work. GO FIGURE. \015\012thanks Peyton\015\012

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Whirlpool portable AC, compressor works, but no exhaust fan


This is a single speed permanent split capacitor motor for the condenser. One of the capacitor wires shows infinite resistance to hot and netral. The motor needs to be replaced. ... Whirlpool ACP102PS Portable Air Conditioner

Hi, two days ago I bought a Danby Premiere DPAC13009 portable AC unit. It worked on the first day reducing the temperature from 32C in the room to 26C in a few hours. Although now there is no cold air coming out of the AC and only the fan is working. I verified the two hoses and the exhaust is working good, lot of air is blowing out. Although, no air seem to be sucked in from the intake hose. I checked and I don't see any obstruction. Could the compressor be dead already??? thank you


Comperssors have a thermal overload. If there is a starting problem or low on freon the conpressor will shut down until cooled off. Try restarting and listen to compressor. ... Danby Air Conditioners

Had a PF code, unplugged the 4 pin probe connector and plugged it back in and fixes that problem until next PF code.....often. Ran perfect for a couple hours and turned it off for the night, when I restarted it the next morning the top blower works but the compressor nor the exhaust fan come on. I have emptied the tank, cleaned the filters, started and restarted, let sit for 10 minutes several times and tried again...compressor doesn't start nor the exhaust fan. The top blower works when on AC,


Hi,Here is a tips that I wrote\012that will help to explain why you get the PF Error CodePF\012Error Code for Appliances\012hea ... DeLonghi Pinguino PACL90 Portable Air Conditioner

I have a whirlpool model ACM102xLO that seems to be dying. I cleaned the coils, and the unit seems to operate normally for a few minutes. Fan motor works, compressor motor seems to work. When I checked the amp pull on the fan motor, it falls in the normal range of 1.2A. When the compressor kicks on, the amp pull jumps to around 10 and climbs to a high of 15 or so, then the compressor shuts off and the amps jump to about 25 or 26, before cutting off completely. The amps then drop to the fan motor


... Whirlpool Air Conditioners

Hi i recently purchased a used convair portable supacool 9 air conditioner the first time i switched it on it appeared to work ok but the next time i turned it on it is working on normal fan mode but when i turn it to air conditioner mode it is doing exactly the same as on normal fan mode the compressor does not appear to be working and is not making the extra noise that it was the first time i have tryed all the switchs including the thermostat but there is only a very simple to use set up any


... Convair Portable Air Conditioner

My Whirlpool AC Model acm184xa1 stopped working yesterday. The compressor appears to still work since the evaporator gets cold but no fan. Can anyone help me trouble shoot this unit? Thank you


REmove the fan and check it separately, if it runs out of the unit you have a relay switch gone bad. ... Air Conditioners

I have a Sharp CV10NH Portable Air Conditioner with the same problem as posted by gtkermit on Jun 08, 2010: works fine for a few minutes then compressor turns off and fan continues for a few minutes then compressor kicks in again and cools for a few minutes (cycles about every 5 minutes perhaps.) I have followed all suggestions on page 30 of the manual (as well as the different options for venting, etc.) ms-shop suggested that the thermostat needs to be replaced. How do i do this? Thank you!


Hello,The problem could be the thermostat, and any of the following compressor cycling for every few minutes\015\012could be over load for the compressor, dirty condenser coils need \015\012cleaning, To check \015\012the compressor\015\01 ... Sharp CV10NH Air Conditioner

Sometimes, when the inside blower shuts down, the outside compressor and fan motor continue to run for some time. Other times, when the inside fan motor is running, the outside fan and compressor motors are not ... if I press the outside reset button, it starts up When both inside fan motor and outside fan and compressor motors are running, it works fine ... warm air blows out of registers. Other than that problem, both units work great!


Sounds like you have a dirty condenser. You are going to need to disconnect the power at the outside unit on the wall by pulling the fuse block out. Take a good look at the louvered covers that are attached to the outside of the unit. Remove the scr ... Ruud UAKA060 Air Conditioner

My condenser fan is not turning on my Maytag portable. Everything else is working find but it is not exhausting anything. Is there a reset?


Need to check the motor for power if power to the fan than either something blocking [clear ]===the motor bearings are seized [try to oil the bearings to free it up ] sometimes catch in time and will run===or the windings are open[burnt up motor nee ... Maytag Portable Air Conditioner M6P09S2A

Whirlpool 240V ADF18040 18000 btu A/C started shutting itself off. Only way to turn back on is to cycle circuit breaker off-on. Did this 5 or 6 times over the course of 2 or 3 days...now won't work at all. It's not short-cycling the compressor, since it did this even with the thermostat off (warmest position). ???Maybe fan motor capacitor???


Hi,Be sure and check the big yellow or main \015\012power wire over to and connected to the compressor. If it is corroded or\015\012 burned and has arched and the brass spade connector is disconnected or \015\012melted you wil ... Air Conditioners

I have a Sharp CVP12LX Portable Air Conditioner and i runs for 10 mins then compressor shuts down fans still blows but now blows warm air if i reset the plug it will work for 10 mins then does it all over again the unit will cool but it takes almost 10 mins to kick in if it feels like it any help would be welcomed


... Sharp Air Conditioners

I have the MR36TQY3f outdoor unit with 2 MW09Y3FM units and 1 MW12Y3FM indoor units! The MW12.. works great and one of the MW9... works great! When I run the 2nd MW9 only (other MW9 & MW12 off)..... the outdoor unit compressor or fan does not come on! If I run all units then ... compressor kicks on runs great, fan runs... lines get cold on the 2 good units ... nothing on 3rd unit... then I turn 2 good units off....and it sounds like the compressor kicks off and the fan will continue to run reall


After looking at the manual for the units, I believe that the system is having trouble with the number of units that you have linked. Here is a portion of the manual about multi system operation>Also link to manual:http://www.fri ... Friedrich MR36TQY3F Split System Air Conditioner

I have BEKO ac , on cool it's working properly but on warm, the condenser fan didn't work and the compressor don't work and each several trials of start up, the compressor work but the condenser fan don't work and soon , the condenser goes to freeze and the unit stop again. can you suggest my problem. Remark: the 3 sensors (2 in and one out) are giving all 6.1 K ohm


... Air Conditioners

Compressor does not run. On turning the AC on, the compressor does not run. The blower fan does though. Checking the relay panel, the relay for the compressor does not engerize. a temporary solution is to put a switch across the contacts the compressor on and then the thermostate is set so that the AC should work, the fan comes on and the unit works as usual. The only exception is that the temperature must be controlled manually.


Hi, if you are energizing the contacts on the contactor, and the compressor runs, the thermostat is faulty. This is what energizes the contactor coil that you have. You need to check to see if you have voltage to the coil on the contactor. You need t ... Coleman Mach 15 Air Conditioner

I have a Haier HWR05XC7 that will NOT work. The compressor turns on, but the fan won't work. The fan moves freely because I tried moving it with a screwdriver, but when I turn the unit on, the compressor kicks on, but no fan. I have been fighting with this thing for weeks and am about to chuck it out of the window. Also, the red error light stays on and there is nothing in the manual on how to troubleshoot it (other than making sure it is turned on and plugged in!). No support from Haier or Circ


HEY< If you start out having problems , what do you think the future of that unit will be! ... Haier Air Conditioners

The fan on the condensing unit isnt working it works for awhile and then shuts off,then the compressor starts to work by itself really hard and the whole condenser heats up really fast so I turn off the breaker and start it again but the fan makes and electric humm and I have to push start the blades to get it to spin and then it will work for awhile and then the fan will stop again after about an hour and then same thing happens


Does the fan turn freely or is it hard to turn by hand? If it is hard to turn the fan motor may need to be replaced. If it isn't hard to turn then check the fan capacitor. You can test it with a multimeter or take it to a heating and air supply and g ... Goodman CLT36AER36 Air Conditioner

Everstar mpk10cr grinding compressor I think.... Fan works fine, will kick into cool mode (elevated fan level) for a few seconds then it sounds like the compressor has a loose mount or something... sometimes it rattles for a few minutes (and cools) but sometimes it shuts the rattling off as fast as it starts and doesnt really ''cool'' or dehumidify.... Some days its works fine all day, others it just never really gets its ''**** together'' so to speak... Can users recharge the coolant themselve


Hi, I hear you , you have to keep her happy and cool!! First of all, no you can't buy R-22 unless you are a contractor and you have a certification card showing you are qualified to use freon. This is not your problem from what you are saying. If thi ... Air Conditioners

I HAVE A GOODMAN CK-36-1A AC AND THE FAN IS NOT WORKING. WAS TOLD TO REPLACE THE CONDENSER CAPACITOR AND IF THAT DID NOT WORK REPLACE THE THE CODENSER FAN MOTOR. THE COMPRESSOR COMES ON BUT SHUT DOWN WHEN IS GET HOT, WAS TOLD THAT THEY WORK LIKE THAT. MY QESTION IS WHAT FAN DID GOODMAN PUT IN THIS AC UNIT SERIAL NO. 97F9895.


Goodman unit you can use a 1/4 hp or 1/3 hp cond. fan motor but it does sound like a cap. Replace cap first. Its very easy to do just open up panel and replace the silver bullet with terminals out the top. It will say on the side what size it is like ... Air Conditioners

GE Zoneline HP PTAC A3B688DAALW1 WIRING DIAGRAM? Found a 6" L white wire with 1/4"F stake-ons loose from center terminal of Compressor capacitor 20/5uf going into the back wiring compartment. Not sure where it came loose from. There is a black multi stake-on terminal block up inside behind the capacitors. Attached it there to a unused spade but now fan does not run the indoor fan when in heat mode (compressor or elect. heat). Before the fan and electric heat worked but compressor just buzzed try


... GE Zoneline AZ55H07D Air Conditioner

My unit's compressor will intermittantly stop working. The thermostat seems to keep the intake unit working but since it can't get the temperature down it never shuts off. We have been removing the batteries and letting the thermostat reset for 20 minutes. (thermostat Honeywell RTH23110B). After the reset the compressor will work again but will fault within a day. I am pretty sure that the compressor and fan are functional as if I press the contactor down it begans functioning. I also, to he


If the air handler coil is clogh , the air won't go through and the compresor will shut off on overload because of high head pressure, also this will happend if the condenser coil (outside) is blocked or if the fan dosn't work .Also if the outdoor un ... Air Conditioners

Compressor works but compressor fan does not


It is possible the capacitor has gone bad, cause, possibly a power surge. Suggest replacing capacitor first and see if problem happens again then I would change fan motor and capacitor. Good luck on your repairs\015\012\015\012Dave ... Air Conditioners

Dometic Rooftop RV a/c unit fan will not run in auto but compressor works. a/c works and fan runs in on position


... Dometic Rooftop RV Air Conditioner

Compressor intermittent Compressor doesn't always come on. Sometimes I have to turn system on and off several times, Uses Duo-Therm 4 button thermostat. When it is working with fan on high, if I reduce speed of fan, compressor will stop.


Sounds like a bad thermostat. Make sure you turn off all related breakers and disconnect switches before attempting to replace it. Good Luck! ... Dometic Rooftop RV Air Conditioner

I have the Nano Max cfi 14000e. Worked good for 5 years 3 months. When turned on seems as if compressor comes in, fan goes high and compressor kicking out and fan back to low. No signs of any fluid leaks, is this a staarter relay type problem, bad compressor.


... Amcor 14000 Portable Air Conditioner

I have a Duo-Therm, mod# 600315.321 on a motorhome. Fan motor overheats, but only after the compressor kicks on. New motor, swapped out caps w/identical working unit. Ground is good. Unit will run all day OK w/just fan, but when put on "cool", it will run and produce cold air for 15 min, the fan then quits. Compressor will run for 5 - 10 minutes more by itself, then the circuit breaker kicks.


... Dometic 57915531 Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1073 seconds