Not working probly two flashs then pause

\015 Mitsubishi electric split air conditioner msh 26 sv\015

Answers :

The two flashes are telling you what's wrong with the unit. Take the cover off of the unit inside(evaporator) and there should be a guide on the panel with the wiring diagram. On this diagram there should also be a solution to what each blink means. One blink means this, two blinks mean that, etc... Hope this is helpful.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Not working probly two flashs then pause


The two flashes are telling you what's wrong with the unit. Take the cover off of the unit inside(evaporator) and there should be a guide on the panel with the wiring diagram. On this diagram there should also be a solution to what each blink means. ... Mitsubishi Air Conditioners

Fujitsu inverter ASTA24LCC aircon wont work on heat mode. Two flashes of red and green lights, followed by five flashes of red light and sequence continues with a pause between. Other modes, fan, cool etc work.


Check that the gas is not leaking, that would be the most likely cause. ... Fujitsu Air Conditioners

THE RED (OPERATION) LIGHT AND GREEN (TIMER) LIGHT ON MY FUJITSU DUCTLESS AIR CONDITIONER ARE FLASHING. PRESSING THE START/STOP BUTTON ON THE REMOTE CONTROL DOES NOT MAKE IT WORK. SWITCHING THE BREAKER OFF AND ON SOMETIMES MAKES IT START BUT NOT ALWAYS. AFTER IT STARTS IT CAN STOP SUDDENLY, AND THE RED AND GREEN LIGHTS START FLASHING AGAIN. THE RED LIGHT FLASHES 6 TIMES, THEN PAUSES, BEFORE FLASHING 6 TIMES, WHILE THE GREEN LIGHT FLASHES CONTINUOUSLY. INDOOR UNITS MODEL #ASU12D1. OUTDOOR


... Fujitsu Air Conditioners

The light for the overfill drawer is flashing but there is nothing in it. Usually if this happens, I open it and close i and it goes off but it won't work this time. I've unplugged it and tried many times but the red light is flashing. The main container is only 1/4 full. It is only about 5 years old and usually only gets used for two weeks in the summer. It is a Danby Noreen


There is a sensor/switch and it is stuck or gone bad. hope this helps tim ... Danby Air Conditioners

I have a samsung AQV12 fan airconditioning unit. The problem is it will not work, the indoor unit has two green lights flashing and one red light flashing.


Hi! Please try this. Remove the battery from the remote then insert it again. Press the up and down temp button at the same time and it will give you code. Please try to click on the link for it will guide you. Hope this helps and have a good one! ... Air Conditioners

After I switch on it works for a few seconds then beeps a few times and switches off by itself leaving two green lights flashing


... Mastercool 67471 Evaporative Cooler Air Conditioner

I have a celestial kfr 70 model the pause and timer lights are flashing and its not running properly I can't work it out


... Air Conditioners

I have just bought a second hand Rinnai convector gas heater,model RCE 516H.It appears to be working really well but I have no instruction manual & when I switch it on it starts with a green light on the power 'on' switch then turns to red after a couple of seconds,is this normal? Also,on the temp. control volume I get two green lights,one moves up & down with the low to high control & the other just flashes on & off,but doesn't move. Thank You.


... Rinnai RHFE-556WTA Direct Vent Heater NG Air Conditioner

I have a Carrier infinity model 38tdb037-3. The outside unit will not come on. the control board on the outside unit shows an amber led on status 2.it is a steady constant flash.the error is an apparent stand by/on demand.munualy depressing the contactor forces the unit to run and seem to work fine. communication is good. the inside unit shows two green leds and one amber constant flash. any ideals. maybe bad control board?


... Carrier Air Conditioners

Green light continually flashes on the front of both units. We have a 2 storey house with 2 condenser units, but 4 A/C units inside the house. 1 downstairs and 3 upstairs. Only 1 downstairs and 1 upstairs are working (off the one condenser), whilst the other two fail to start. Thanks


I think it's multi type air conditioners. May be other compressor not working. check the loose contacts/compressor. ... LG Air Conditioners

My Ruud silhouette II some times will not operate. I the room temperature is below the thermostat setpoint and the status indicator on it says ''System On.'' I The unit and the green ''OK'' LED is flashing 4 times, then pausing repeatedly. After some time, the unit will function properly (I have not checked the LEDs while it is operating properly). It will work fine for weeks and then the problem reappears. Any ideas?


4 Blinks is an error code of a sticking pressure switch. A pressure switch is a safety, which in this case is being used to verify that your furnace is drafting properly. Yours in particular is sticking in the closed position even after the call for ... Ruud UAKA037 Air Conditioner

AC stopped working last night. Now a red light is flashing and the display reads "stop". AC is two years old. Is it fixable?


... Royal Sovereign ARP-5010X Portable Air Conditioner

My Intertherm, electric ignition furnace will hum and hum but not click on. There are two yello flashing lights until we reset it by turning off the gas and turning down the thermostat. The unit resets itself and I get a steady red light when its working. Is this a pressure switch issue?


That blinking yellow light is an error code. If you look behind the main cover there will be a wiring diagram and error code chart. This will give you an idea what the problem is. ... Air Conditioners

Model, 42HQE009/012, Hi, When I start the unit in heat mode the OPERATION and PRE DEF lights come on as useual but only for 5 seconds instede of a couple of mins. then the pre def light goe's out, nothing happens for about 5 mins. and then the same two lights start to flash together with no response from the remote, the power has to be cut to get them off , the cool mode works fine. Thanks, David.


... Carrier 36KCARMS Air Conditioner

AMCOR 24,000 BTU split system. Worked fine two years, then today it had no power. Checked circuit breaker, it had popped. Reset CB and went to inside unit - would not turn on or off with remote or hard button. Checked wiring with an electrical tester, and wires to outside unit hot, as well as inside unit. No flashing codes, nothing. Unit won't turn on,even with power. Is there a fuse somewhere in the inner unit or outer unit?


I had this same problem. I disconnected the thermostat wire out side at the condenser and reconnected it and it started working. A couple days later it blew the breaker again this time I found the bus where the L1, L2. GR wire connect at the condense ... AmcorAire UCHW-H24AF2 Split System Air Conditioner

We have a seeley Breezair aircon with a diagnotic button flashing in the control box. Told we need a new control box which we have done and still not working. Came on for a few minutes and then went off again. Could this diagnostic button mean something else. Had new motor put in under warranty two years ago. System only 5 years old. Many thanks David


Yes it could mean many things there should be a code for faults eg fast beep slow beep ect ect you need to establish what code it is and go from there ... Air Conditioners

Two out of four elermants not working Dimplex XLSN? Dimplex XLSN storage Heater Hi Can anyone help please? The storage heater has four elements, I noticed only two were working, they where the two starting from the control panel end. I removed one of the elements that wasn?t working and replaced it with a new one the new element didn?t heat up when the power was switched on, anyone know what the problem may be. Thanks Tony


Hi,If you know that the element is not working and the element is new then you need to use an electrical meter to trace down the power and see where it is stopping at...My feeling is that you have a bad relay and that is your problem. ... Air Conditioners

I have a ducted sanyo split system. The model number is SPW-C361GH5TU. The unit in the ceiling stopped working about 4 weeks ago. The outside compressor would start up but stop after a short period of time. I managed to get a technician to work on the unit. He said it was the PC board. It took two weeks to get the part but when it was fitted, the unit still didn't work and the technician told me the problem was with the fan motor. Another two weeks have elapsed, and he now tells me it will take


You can order the part from link below.:--\015\012they provide quick deliveries:--\015\012http://www.jpcparts.com/103-546-8441.html\015\012\015\012you can p ... Sanyo Split System Air Conditioner

My carrier air conditioner is not working. We have two exterior units. One for upstairs (smaller) and one for the downstairs(larger unit). That being said we have two seperate thermostats inside our home. The upstairs unit is working fine. The downstairs thermostat shows on Auto that the unit should be kicking on based on the temp. However, the outdoor unit for downstairs is not working. So far I have checked the downstairs vents and they are blowing air although not very cool. I also tu


Hi,The problem is in the outdoor unit...The compressor could be locked up, the condenser fan could be bad... or from what you are saying the contactor for the outdoor unit is either not pulling in or is bad...that also can be a result of ... Air Conditioners

I don't know what model my fan is, but it's only 3 years old and suddenly two days ago the light and fan quit working. We replaced the light switch on the wall-nothing. Took apart whatwe could of the fan to look at the wiring-all intact. We then replaced the battery in the remote and it instantly worked fine again. After putting it all back together it stayed lit with the fan working for about two hours at which time I turned it off using the wall switch. I immediately tried turning it back on a


That may be, because you were using the Remote Control to operate it, but then turned off the wall switch instead of turning it off using the Remote Control.Turn the wall switch back On and try to get the Remote Control to take back over ... Hampton Bay Air Conditioners

Have a whole house fan which has a 2 speed motor. Stopped working. I know there is power to the fan. checked with a voltmeter. Have taken off the 2 speed switch and connected the two black wires together, did not work. connected the two black wires and a red wire together, did not work. Is there a way to test the motor?


Test Motor: Gain access into the motor area then smell the motor. If you detect a strong odor (the shellac that coats the copper coil windings when the motor is burning or burnt out) then the motor is bad and needs to be replaced.\015\012Second ... Air Conditioners

Hi, two days ago I bought a Danby Premiere DPAC13009 portable AC unit. It worked on the first day reducing the temperature from 32C in the room to 26C in a few hours. Although now there is no cold air coming out of the AC and only the fan is working. I verified the two hoses and the exhaust is working good, lot of air is blowing out. Although, no air seem to be sucked in from the intake hose. I checked and I don't see any obstruction. Could the compressor be dead already??? thank you


Comperssors have a thermal overload. If there is a starting problem or low on freon the conpressor will shut down until cooled off. Try restarting and listen to compressor. ... Danby Air Conditioners

Hi, the lights on my circiut board are flashing the one on the left is on all the time and the one to the right of it flashes two times and then waits and then flashes two times again


Error CodesA green LED indicates system faultsSteady On: System OKSteady OFF: Board control fault or no power applied1 Flash: Ignition failure (control in one-hour lockout)2 Flashes: Pressure switch fault, f ... Ruud Central System Air Conditioner

I have an electrolux kelvinator split system and all of a sudden its not working. you turn it on (the heat setting) and it says its on defrost and nothing happens for at least 5minutes and then all 4 lights flash...there seems to be no sequence in the flashing they all flash together. mind you the air con isnt working either.


... Air Conditioners

Hi guys i hav a ampac pulsar series micro spa controller model 2082spx 15amp it just stop and the touch pads just flash plug pump and air blower to other power sorce thay work fine but put them through the controller works for about a hour then stops and touch pads flash its a signture spa im asuming its the controller is the fault


... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0670 seconds